HomeMy WebLinkAboutHorzontal SliderCGI Windows & Doors, Inc.
10100 NW 25 Street
Miami, Fl. 33172
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER-
Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority
Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product
Control Section (Tn Miami -Dade County) and/ or the AHJ (in areas other than Miami -Dade County) reserve
the right to have this product or material tested for quality assurance purposes. If this product or material
fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ
may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction.
RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control
Section that this product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code, including the High Velocity Hurricane Zone.
DESCRIPTION: Series "Sentinel 120" Aluminum Horizontal Sliding Window - L.M.I.
APPROVAL DOCUMENT: Drawing No. W10-18, titled "Series Sentinel 120 Alum. Horiz. Sliding
Wdw. (L.M.I./ S.M.I.)", sheets 1, 1. 1, 2, 2.1, 3, 3.1, 4 through I I of 11, dated 03/29/10 with revision "H"
dated 09/05/17, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P. E., bearing the
Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration
date by the Miami -Dade County Product Control Section.
FISSILE IMPACT RATING: Large and Small Missile Impact Resistant
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state,
series, and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted
herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been
no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change
in the materials, use, and/ or manufacture of the product or process. Misuse of this NOA as an endorsement
of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure
to comply with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed, then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No. 15--0929.13 and consists of this page 1 and evidence pages E-1, E-2, E-3 and
E-1, as well as approval document mentioned above.
The submitted documentation was reviewed by Jorge M. Plasencia, P. E.
NOA No. 17-0918.09
MIAMI-DADE COUNTY Expiration Date: September 22, 2020
t�Ys Approval Date: November 02, 2017
Page 1
CGI Windows & Doors, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's
A. DRAWINGS
1. Manufacturer's dic drawings and sections.
(Submitted under NOA's No.'s 10-0510.12 and 15-0512.05)
2. Drawing No. W10-18, titled "Series Sentinel 120 Alum Horiz. Sliding Wdw. (L.M.I./
S.M.I.)", sheets 1, 1. 1, 2, 2.1, 3, 3.1, 4 through 11 of 11, dated 03/29/10 with revision
"G" dated 05102/16, prepared by Al-Farooq Corporation, signed and sealed by Javad
Ahmad, P.E.
B. TESTS
1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 201-94
2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94
4) Large Missile Impact Test, per FSC, TAS 201-94
5) Cyclic Wind Pressure Loading, per FBC, TAS 203-94
6) Forced Entry Test, FBC 2411 3.2.1, TAS 202-94
along with marked -up drawings and installation diagram of a series Sentinel 120
aluminum horizontal sliding window, prepared by Certified Test Laboratories, Test
Report No. CTLA-3062W, dated 07/07115, signed and sealed by Ramesh C. Patel,
P.E.
2. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
2) Large Missile Impact Test, per FBC, TAS 201-94
3) Cyclic Wind Pressure Loading, per FBC, TAS 203-94
along with marked -up drawings and installation diagram of a series fixed window, to
qualify DuPont "Butacite" PVB interlayer, Duraseal® and Super Spacer® insulating
glass spacer, prepared by Certified Test Laboratories, Test Report No. CTLA-3056
WA, dated 03103115, signed and sealed by Ramesh C. Patel, P.E.
(Submitted under previous NOA No. 15-051.2.05)
3. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
2) Large Missile Impact Test, per FBC, TAS 201-94
3) Cyclic Wind Pressure Loading, per FBC, TAS 203-94
along with marked -up drawings and installation diagram of a series project out
window, to qualify DuPont `Butacite" PVB interlayer, Duraseal(7 and Super Spacer®
insulating glass spacer, prepared by Certified Test Laboratories, Test Report No.
CTLA-3056 WB, dated 03/03115, signed and sealed by Ramesh C. Patel, P.E.
(Submitted under previous NOA No. 15-05.12.05)
Jorge M, Plasencia, P. E.
Prod et Control Unit Supervisor
NOA No. 17-0918.09
Expiration Date: September 22, 2020
Approval Date: November 02, 201.7
E-1
CGI Windows & Doors, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
B. TESTS (CONTINUED)
4. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
2) Large Missile Impact Test, per FBC, TAS 201-94
3) Cyclic Wind Pressure Loading, per FBC, TAS 203-94
along with marked -up drawings and installation diagram of a series aluminum fixed
window, to qualify DuPont "Butacite" PVB interlayer, Duraseal(t and Super Spacer®
insulating glass spacer, prepared by Certified Test Laboratories, Test Report No.
CTLAW-3056 WC, dated 04116/15, signed and sealed by Ramesh C. Patel, P.E.
(Submitted under previous NDA No. 15-0512.05)
5. Test reports on: 1) Air Infiltration Test, per FBC, TAS 201-94
2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94
4) Small Missile Impact Test, per FBC, TAS 201-94
5) Cyclic Wind Pressure Loading, per FBC, TAS 203-94
6) Forced Entry Test, FBC 2411 3.2.1, TAS 202-94
along with marked -up drawings and installation diagram of a series "Sentinel"
aluminum horizontal sliding window, prepared by Hurricane Test Laboratory, LLC,
Test Report No. HTL-0080-0102-10, dated 06/04/10, signed and sealed by Vinu J.
Abraham, P. E.
(Submitted under NOA No. 10-0510.12)
C. CALCULATIONS
1. Anchor verification calculations and structural analysis, complying with FBC 5`
Edition (2014), prepared by Al-Farooq Corporation, dated 09/17/15 revised on
05/11/16, signed and sealed by Javad Ahmad, P. E.
2. Glazing complies with ASTM E1300--09
D. QUALITY ASSURANCE
1. Miami -Dade Department of Regulatory and Economic Resources (RER).
E. MATERIAL CERTIFICATIONS
1. Notice of Acceptance No. 14-0916.10 issued to Kuraray America, Inc. for their
"Butacite® PVB Glass Interlayer" dated 04/25/15, expiring on 12/11/16.
2. Notice of Acceptance No. 14-0916.11 issued to Kuraray America, Inc. for their
"SentryGlas® (Clear and White) Glass Interlayers" dated 06125/15, expiring on
07/04/18.
ge M. Plasencia, P. E.
Product Control Unit Supervisor
NOA No. 17-0918.09
Expiration Date: September 22, 2020
Approval Date: November 02, 2017
E-2
CGI Windows & Doors, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
E. MATERIAL CERTIFICATIONS (CONTINUED)
3. Notice of Acceptance No. 14-0423.15 issued to Eastman Chemical Company (MA)
for their "Saflex CP - Saflex and Saflex HP Composite Glass Interlayers with PET
Core" dated 06/19/14, expiring on 12111/18.
4. Notice of Acceptance No. 14^0423.17 issued to Eastman Chemical Company (MA)
for their "Saflex Clear and Color Glass Interlayers" dated 0619114, expiring on
05/21/16.
F. STATEMENTS
1. Statement letter of conformance, of complying with FBC 5t' Edition (2014) and of no
financial interest, dated 08/17115, issued by Al-Farooq Corporation, signed and sealed
by Javad Ahmad, P. E.
2. Laboratory compliance letters for Test Report No. CTLA-3062W, dated 07107/15,
issued by Certified Test Laboratories, signed and sealed by Ramesh C. Patel, P. E.
3. Testing Proposal issued by the Product Control Section, dated 04108115, signed by
Jaime Gascon, P. E., Section Supervisor.
4. Laboratory compliance letters for Test Reports No.'s CTLA-3056 WA, dated
03/03115, CTLA--3056 WB, dated 03/03/15 and CTLA-3056 WC, dated 04/16115, all
issued by Certified Test Laboratories, all signed and sealed by Ramesh C. Patel, P. E.
(Submitted under previous NOA No. 15-0512.05)
5. Testing Proposal issued by the Product Control Section, dated 12/16/14, signed by
Jaime Gascon, P. E., Section Supervisor.
(Submitted under previous NOA No. 15-0512.05)
6. Laboratory compliance letters for Test Report No. HTL-0080--0102-10, issued by
Hurricane Test Laboratory, LLC, dated 06104/10, signed and sealed by Vinu J.
Abraham, P. E.
(Submitted under NOA No. 10-0510.12)
G. OTHERS
1. Notice of Acceptance No. 15-0512.05, issued to CGI Windows & Doors for their
Series "Sentinel 120" Aluminum Horizontal Sliding Window L.M.I., approved on
08/20/15 and expiring on 09/22/20.
2. NEW EVIDENCE SUBMITTED
A. DRAWINGS
1. Drawing No. W10 -I8, titled "Series Sentinel 120 Alum Horiz. Sliding Wdw. (L.M.I./
S.M.1.)", sheets 1, 1. 1, 2, 2.1, 3, 3.1, 4 through 11 of 11, dated 03/29/10 with revision
"H" dated 09/05117, prepared by Al-Farooq Corporation, signed and sealed by Javad
Ahmad, P.E.
urge M. Plasencia, P. E.
Product Control Unit Supervisor
NOA No. 17-0918.09
Expiration Date: September 22, 2020
Approval Date: November 02, 2017
E--3
CGI Windows & Doors, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
B. TESTS
1. None.
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. Miami -Dade Department of Regulatory and Economic Resources (RER).
E. MATERIAL CERTIFICATIONS
1. Notice of Acceptance No. 16-1117.01 issued to Kuraray America, Inc. for their
"Trosifol(k Ultraclear, Clear and Color PVB Glass Interlayers" dated 01119117,
expiring on 07108/19.
2. Notice of Acceptance No. 14-0916.1.1 issued to Kuraray America, Inc. for their
"SentryGlas® (Clear and White) Interlayer" dated 06/25/15, expiring on 07104118.
3. Notice of Acceptance No. 17-0712.03 issued to Eastman Chemical Company (MA)
for their "Saflex CP - Saflex and Saflex IIP Composite Glass Interlayers with PET
Core" dated 09/07/17, expiring on 12111118.
4. Notice of Acceptance No. 17-0712.05 issued to Eastman Chemical Company (MA)
for their "Saflex Clear and Color Glass Interlayers" dated 09107117, expiring on
05121121.
F. STATEMENTS
1. Statement letter of conformance to FBC 5th Edition (2014) and FBC 611 Edition
(201.7), dated 08/30117, issued by Al-Farooq Corporation, signed and sealed by Javad
Ahmad, P. E.
G. OTHERS
1. This NOA revises NOA 415-0929.13, expiring on 09/22120.
orge M. Plasencia, P. E.
Prqduct Control unit Supervisor
NOA No. 17-0918.99
Expiration Date: September 22, 2920
Approval Date: November 02, 2017
E-4
T
FLANGE & FLANGE ADAPTOR FRAME
A'
BUCK WIDTH
5 1/2" 13 5/16=
MAX. 5" MAX MA%. in
HEAD/SILL
HEAD/SILL ��� ---
m��J--'ILE
E2 kl�l
e
M o
J
via
�I
i�
FALSE MUNTINS32 J
(SURFACE APPLIED) 32 7/8" 7/B=
OPTIONAL D.L. OPG. Q.L. OPG.
38 3/8 -
VENT WIDTH FIN FRAME
EBUAL LEG FRAME
SERIES SENTINEL 120
ALUMINUM HORIZONTAL SLIDING WINDOW
DESIGN LOAD RATINGS FOR THESE WINDOWS TO BE AS PER
CHARTS SHOWN ON SHEETS 2 & 3.
APPROVAL APPLIES TO SINGLE UNITS OR SIDE BY SIDE COMBINATIONS
OF H.R./H.R. OR HORIZONTAL ROLLING WITH OTHER MIAMI-OADE COUNTY
APPROVED WINDOWS USING MIAMI -DARE COUNTY APPROVED MULLIONS
IN BETWEEN,
LOWER DESIGN PRESSURE FROM WINDOWS OR MULLION APPROVAL
WILL APPLY TO ENTIRE SYSTEM.
THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE
REQUIREMENTS OF THE 2014 (5TH EDITION)/2017 (6TH EDITION) FLORIDA
BUILDING CODE INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ).
JOY OR 26Y WOOD BUCKS & BUCK FASTENERS BY OTHERS, MUST BE
DESIGNED AND INSTALLED ADEQUATELY TO TRANSFER APPLIED PRODUCT LOADS
TO THE BUILDING STRUCTURE
ANCHORS SHALL BE CORROSION RESISTANT, SPACED AS SHOWN ON DI
AND INSTALLED PER MANUPS INSTRUCTIONS, SPECIFIED EMBEDMENT TO BASE
MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO,
A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY
ALL SHIMS TO BE HIGH IMPACT, NON-METALUC AND NON-COMPRESSIBLE.
MATERIALS INCLUDING BUT NOT UNITED TO STEEL/METAL SCREWS, THAT
COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE
REQUIREMENTS OF THE 2014/2077 FLORIDA BLDG. CODE & ADOPTED STANDARDS.
THIS PRODUCT APPROVAL IS GENERIC AND DOES NOT PROVIDE INFORMATION
FOR A SITE SPECIFIC PRQIECT, i.e. LIFE SAFETY OF THIS PRODUCT. ADEQUACY
OF STRUCTURE RECEMNG THIS PRODUCT AND BEAUNO AROUND OPENING FOR
WATER INFILTRATION RESISTANCE EFC.
CONDITIONS NOT SHOWN IN THIS DRAWING ARE TO BE ANALYZED SEPARATELY.
AND TO BE REVIEWED BY BUILDING OFFICIAL.
Z
O� m
iia
Ogo�
In
OGa'�
0-0
O°I2rc
LLZNgg o
Q wPe t
� U
G I
0 W n
G
� n N
ryMT
fr o n n
C)_5
PRODUCT REVISED
in
plyyg with the FI-id.
Building Cotle w^
NOA-No. 17-0918.09
Expiration Da 0912212020
N 8 0
By
LAMINATED
eProtlua[Con1ro1 c� z Ola
LAMINATED GLASS
INSULATING LAM. GLASS o n
LARGE MISSILE IMPACT - w "_.
SMALL MISSILE IMPACT
`T11uulTepii
�P.®.Aligq
®•. EOR . �a draw'", a na.
•.. Rror:�8��j W10 18
TYPICAL ELEVATION111" 110
FFLAN
LANGE WIDTH GE WIDTH o'
5 1/2"
MAX. 5, M MAX. 5" MAX. a "
H 1 SILL m� HEAD/SILL TYP. C
/ A, AITG. STILE z W
5 5�� XPi f• S i u
�,i / Ili Ili
�I IT
II II II Q�jymu
II I II Ei I F ' II F h
�' II IIIIII II .I ILII � m
5 5 it II 1 n II
U
C. C
FALSE MUNTIN9
--AO L. ANCHOR REDD. -F HUMINS AD L, ANCHOR REGO.
(SURFACE APPl1ED) AT CENTER OF ALL PANELS (SURFACE APPLIED) 24 1/2" 49 5/6" AT CENTER OF ALL PANELS O
OPTIONAL p.L. OPG. D.L OPC. FIXED OR OPERABLE OPTIONAL D.L. pp0, D.L OPG. FIXED OR OPERABLE p �j n
ABOVE M. PANEL WIDTHS 29° gATHEgOI51LL EL WIDTHS {O w
26• AT HEAD/SILL VENT WIDTH G
VENT WIDTH O SN a
FLANGE & FLANGE ADAPTOR FRAME EQUAL LEG FRAME
o
110"
61. WIDTH
5 „2• 13 5/16" s d
MAX. 5' MAX.
MAX
HEPO/SILL 7.TGT
MAHEADIT
A2' . STILE
rc
E2 i
6
PRODUCT REVISED 7®5ffiL
mplYlo9 with the FloHtla j•
FALSE MUNTINS NOA -Nc,Cotle 17.0918.09
(SURFACE APPLIm) 24 1/2" J 49 5/8" e 8 0
OPT10NAL D.L. DPG. D.L. OPG. EaplraHoa nate 9/22/2020 DF drawing. no.
fl
VENT WIDTH Mlam -Da rotluct Contml '���®�}11•��®��`` W10—,$
FIN FRAME ara IM" sheet i,tof ��
IT
II N
I I F 41 11 F
I. II
II-----
A's
6
1 I
DESIGN LOAD CAPACITY - FSF
(XO OR OX SIZES)
STD.. MTG. RA H.D. M. RAIL ILD, MTG, RACL
Cw TYP95 GL188 M. -Emo
DUCK DIMS. 'A'k'61', '9'&'9t' IF, k'Bi' 'C'
WIDTH
STD. MTG. RAIL H.D. MTG. RAIL
WIDTH
HEIGHT EXT(,) INT.(-) EXT.(+) INT.(-) E -(+) INT(-)
GLASS TYpffi TIMIS TTE83
FLANGE DIMS.
BUCK DIMS.
'd'k'A1', '8'k'Hl' 'B' & 'el'
WIDTH
HEIGHT
WIOIH
HEIGHT
EXT.(+) INT(-) EXT.(+)
28-1/2"
37-3/8" 65.0 1 '05.0 8- 90.0 65.0 65.0
25-1/Z'
55-3/a"
8-15/16
83-1/2`
650 6510 90.0 90.0
37"
85.0 65.0 60.0 90.0 65.0 65.0
36"
65.0 65.0
65.0 65.0 80.0 90.0
53-1 jB"
Z6"
52
25°
65.0 65.0 80.0 90.0
]4'
73"
65.0 85.0 80.0 90.0
28-1/2"
25-1/2'
65.0 65.0 80.0 90.0
37"
38_3/8•
36'
37-3/8"
65.0 65.0 90.0 90.0
65.0 65.0 80.0 90.0
53-1/8"
52-1/8'
74'
73"
65.0 65.0 80.0 90.0
26-1/2"
25-1/2'
BSO 65.0 80.0 90.0
37'
50_5/9-
36'
49-5/8"
65.0 65.0 80.0 90.0
65.0 65.0 B0D '90.0
Ea
52-1/8"
74"
73'
drawing
w�
65.0 b5.0 80,0 90.0
26-1/2"
DECLARATORY STATEMENT DCA05-DEC-219
25-1/2
A� yy�g, �A`J�
A�ll,vtH llttt
5.0 8GD 90.0
65.0fl.�.2
37"
36"
fi5.0 80.0 90.0
53-1/8"
63.
52-1/8'
82,.
65.0 80.0 90.0
74'
73"
60.2 80.0 90.0
(1/2W)
j � G
OPERATING VENTS TO BE 1/2 OF THE WINDOW WIDTH
'XD OR OX'
DESIGN LOAD CAPACITY - FEE
(XO OR OK SIZES)
DIMS.
STD.. MTG. RA H.D. M. RAIL ILD, MTG, RACL
Cw TYP95 GL188 M. -Emo
DUCK DIMS. 'A'k'61', '9'&'9t' IF, k'Bi' 'C'
WIDTH
NEIGHS
WIDTH
HEIGHT EXT(,) INT.(-) EXT.(+) INT.(-) E -(+) INT(-)
55-3/4'
8-15/16
83-1/2"
26°
54-3/4`
77-15/1625"
82-1/2°
65.0 65.0 80.0 90.0 65.0 65.0
65.0 z, 80.0 90,0 65.0 65.0
85.0 65D 80.0 90.0 85.0 65.0
55-3/4'
8-15/16'
83-1/2"
38-3/8"
54-3/4
7-15/18
82-1/2"
65.0 65.0 80.0. 90.0 65.0 65.0
37-3/8" 65.0 1 '05.0 8- 90.0 65.0 65.0
65.0 85.0 60.D 90.0 65.0 65.0
55-3/a"
8-15/16
83-1/2`
50-5/8'
54-3/4'
-15/16
82-1/2"
85.0 65.0 60.0 90.0 65.0 65.0
- - - -
49-5/8"65.0 65:0
65.0 65.0
56-3/4
8-15/16
63'
54-3/4'
7-15/16
65.0 65.0 80.6 90.D 65.0 85.0
62"65.0
65.0 65.0
(1/3W) (2/3W)
� G
OPERATING VENTS TO BE 1/3 OF THE WINDOW WIDTH
'XO OR OX'
PRODUCT REVISED
plyoBu
CC g 'th the Floritla lialn9 G
NOw-No. 17-09.18.09 zgym^ m
Bpi-... oat. 09/2212020 0 w 2
F zBy
Mlam -Da uct Control o � N ^, �
��N e
o dOQo
O
Q m�Ia6
14' NP.
BUCK DIMS
14 11'P.
BUCK DIMS
BUCK DIMS
Gow4o�
tiEzH
RANGE FRAME
FIANGE DIM9
EQUAL LEG FRAMEFIELANGE
r
AUNPTOR E -RAM
FIANGE DIMS
°
n
ry
FLANGE & FLANGE ADAPTOR FRAME
EQUAL LEG FRAME
°
LK
oNOTE:
Ea
E4
GLASS CAPACITIES ON THIS SHEET ARE
EASED ON ASTM El 300-09 (3 SEC. GUSTS)
AND FLORIDA BUILDING COMMISSION
, �
,fir
e� ROE •.K,^
'.'�, • . o�aD$.•����0
drawing
w�
TD. MTG RAIL,'
H.D. MTG. RAIL
DECLARATORY STATEMENT DCA05-DEC-219
A� yy�g, �A`J�
A�ll,vtH llttt
(sheet 2 of 1'
DESIGN LOAD CAPACITY" - PSF
(XOX SIZES)
BUCK DIMS
FLANGE FRAME
75 T,P. BUCK DIMS
EQUAL LEG FRAME FLANGE
SND. MTG. AA¢ B.D. MTG. RAII,
GGS9 TYPBS GL9B9 TYPBS
FL
FLANGE DIMS.
BUCK DIMS.
'd'4'dt', 'B' u'Bl'
WIDTH
HEIGHT
HEIGHT
EXT.(,) IM.(-) tM.{+) INT.(-)
74"
73"
ES
55.0 5,ix 60.0 90.0106-1/4•
26"
4"
25'
65.0 65,0 80.0 90.0111"
NOTE:
to.0 90.074"
E4
D MTG. RAIL:
GLASS CAPACITIES ON THIS SHEET ARE
BASED ON ASTM E1300-09 (3 SEC. GUSTS)
AND FLORIDA BUILDING COMMISSION
DECLARATORY STATEMENT DCA05-DEC-219
��®. •., OF
y, fie• D�°'��+�
65.0 65,0 80.0 90.0108-1/4"
MTG. RAIL H
38-3/6"
4"
37-3/8"
65.0 65.0 60.0 90.0111"
E-D-
66.0 65.0 60.0 90.D74"
650 65.0 80.0 90.0
8-1/4'
S0-5/8"
4"
49-5/6
85.0 65.080.0 80.0
65.0 65.0 80.0 90.0
9o.0
65A 6`.0
63"
4"
83"
180.0]�
Bt.6 6t.6 90.0
60.0 60.0 90.0
OPERATING VENTS TO BE 1/3 OF THE WINDOW WIDTH
'XOX'
(1/4i')
w o-
OPERATING VENTS TO BE 1/4 OF THE WINDOW WIDTH
'XOX'
PRODUCT REVISED
g Lyn' with the Florida
8ulltlin
NOA-No. 17-0918.09
E p rat6on Datt. 09/22/2020
Miami -Dal roduet Control
BUCK DIMS
FLANGE FRAME
75 T,P. BUCK DIMS
EQUAL LEG FRAME FLANGE
BUCK DIMS
ADAPTOR FRAME
FLANGE DIMS
FLANGE DIMS
FLANGE & FLANGE ADAPTOR FRAME
EQUAL LEG FRAME
ES
`
NOTE:
__eek
E4
E4
D MTG. RAIL:
GLASS CAPACITIES ON THIS SHEET ARE
BASED ON ASTM E1300-09 (3 SEC. GUSTS)
AND FLORIDA BUILDING COMMISSION
DECLARATORY STATEMENT DCA05-DEC-219
��®. •., OF
y, fie• D�°'��+�
STD.
MTG. RAIL H
(1/4i')
w o-
OPERATING VENTS TO BE 1/4 OF THE WINDOW WIDTH
'XOX'
PRODUCT REVISED
g Lyn' with the Florida
8ulltlin
NOA-No. 17-0918.09
E p rat6on Datt. 09/22/2020
Miami -Dal roduet Control
ma
hawing no.
W10-18
BUCK DIMS
FLANGE FRAME
75 T,P. BUCK DIMS
EQUAL LEG FRAME FLANGE
BUCK DIMS
ADAPTOR FRAME
FLANGE DIMS
FLANGE DIMS
FLANGE & FLANGE ADAPTOR FRAME
EQUAL LEG FRAME
ES
`
NOTE:
N .70618
I -Yr �•
E4
E4
D MTG. RAIL:
GLASS CAPACITIES ON THIS SHEET ARE
BASED ON ASTM E1300-09 (3 SEC. GUSTS)
AND FLORIDA BUILDING COMMISSION
DECLARATORY STATEMENT DCA05-DEC-219
��®. •., OF
y, fie• D�°'��+�
STD.
MTG. RAIL H
ma
hawing no.
W10-18
PRODUCT REVISED `I�~ n
plying with the Florida (o o
Builtling C°tle
NOn-N°. 17.0918.09
Z �$expiration Date 09/2?J2020 0k zQ
p4 �I
By g a
miam�0aa roaM°t convol � 's � � o
5.qk
Cct
�ypm N
Q dip
0���
a W o
LLz0
O
V
/3W)
2/3W
i G OPERATING VENTS TO BE 1/3 OF THE WINDOW WIDTH c
i. OSn o
N N n
'XO OR OX'
3
OPERATING VENTS TO 9E 1/2 OF THE WINDOW WIDTH C z 4
I 'SO
'XO OR OX' r
O
BUCK DIMS h�
N04�
�€4F�
FIN FRAME
FIN FRAME ° s
\\\u t n a n urrr
Na 7�2
NOTE:
GLASS CAPACITIES ON THIS SHEET ARE
6a 6a BASED ON ASTM E1300-09 (3 SEC, GUSTS) ' O'.e OF &��� draw g
AND FLORIDA BUILDING COMMISSION
W10 18
1D. MTG.RAL, H.D. MTG. RAIL: DECLARATORY STATEMENT DCA05-DEC-219
DESIGN LOAD CAPACITY - PSF
(XO Oft DX SIZES)
STD. MTC. RAIL, A.P. MTG. RAIL
cress 1TP96 ctnss TTeea
avcx nDss. 'e'&'A1', re'aree 'a' a'st
WIDTH HEIGHT IXT.(+) IM(-) IXT.(+) IM.(-)
25-1/2° 65.0 65.0 80.0 80.0
J6" 25' 65.I.M.
fi5.0 80.0 80A
52-1/8' 65.0 fi5.0 BOA 80A
]3' fi5.0 65.0 80.0 80.0
25-1/2" fi5.0 65.0 80.0 811.0
3fi' 3]_3/8. 65.0 65.0 800 80.0
52-1/8" fi5.0 65.0 80.0 800
]3' 6S0 s5.p 60.o sa.p
zs-t/2"
E6�1
.0ep.pep.o3'
:pep:peo.o
80080.p25
-t/2".0
80.
80:060
eppep.o0
80.0]]'
2 80.0
80.0
DESIGN LOAD CAPACITY - PSF
PRODUCT REVISED'
EVISED
plying with the Florida(XOX SIZES) J j
building Cade o
tlDa-xo. 17-0918.09 Z i
Explratloa Date 09/22/2020By
ppz
--
OR
Z n
illiami a� roduct Control � Q D � e
O?Nl�•
ap�m
Oaoa�
Q z 2 k
d �
- c I
0
K
D 2
OPERATING VENTS TO BE 1/3 OF THE WINDOW WIDTH OPERATING VENTS TO BE 1/4 OF THE WINDOW WIDTH
C Z
'XOX' ( 'XOX' 3 0
om
6 U <
O
SUCH DIMS
- w 3
FIN FRAME
FIN FRAME t. ss
`,t11111111/ll A' O
�gq/
FS 1
NOTE: -�( ��= e 3
�fLS'I�2I GLASS CAPACITIES ON THIS SHEET ARE �� 9 ,
Ea ea uASED ON ASTM E1300-09 (3 SEC. GUSTS) t eg�e drawing na.
AND FLORIDA BUILDING COMMISSION �� . , !� W10-1$
STD MTG RAIL, H.D.H.D MTG. RAIL: DECLARATORY STATEMENT DCA05-DEC-219 0�
°jlllollltltl sheet 3,1at 11
ANN. GLASS
.075" Intcdayer
Saflex CP With PET Core
By 'Eaetmvn Chemical Cc.'
OR
.Oso" mtedayer
SafieX Clear And Calor Glasa
By 'Eaetmon Chemicol Ca.'
OR
.am" Interlayer
SentryGlaa
By Kuraruy America, Inc:
OR
090" Interlayer
Trvsifvl
By 'Kuramy Americo, Inc.'
r1/8" ANN. GLASS
m sIUCGNE
OE 1200
m /DOW CORNING 899
DOW CORNING 995
0
� A7 1/4 POINTS ON LRES
W M7 WIDER THAN 36"
GLASS TYPE 'A'
5/16' NOMINAL LAM. GLASS
1/0" ANN. GLASS
0]5" Int rlaycr
By'E Cp Mtn PLT core
O'Eastman Chemical Ca.'
R
090" Intedayer
Bollen Clear AndI"t Glass
emical
By '[astmon ChCO.'
OR
1/4" AIR SPACE 09O" Intedoyer 1f4" AIR
B
Byy s
'Kor,Kumray America, Inc.'
1/e" ANN. GLASS -r OR
090" Infcrlayer 1/8" HEAT S7?EN'0 t
Trasifol PV9
By Karoray Americo, Inc.'
r-1/8" ANN. GLASS
/8" HEAT STREN'D GLASS
.075" Interlayer
so. CP With PET Care
By 'Eaatmon Chemical Co.'
OR
090" Intedayer
Svflev Clear And color Glace
'Eastman Chemical Cv.'
GR
.090" Interlayer
SentryGlas
By --y Americo, Inc.'
OR
.090' Interlayer
Tm,ifaI WB
By 'Karvray Arnce—, Inc.'
1/5' NEAT STREN'U GLASS
SIU. -E
GE i200
/IOOW CORNING 899
DOW CORNING 995
FN
O
"N 0
AT 1/4 POINiS ON Lf1E5
MJ WIDER THAN 36°
GLASS TYPE
5/i6' NOMINAL LAM. GLASS
1/e' HEAT STREN'D GLASS
.075' Intedayer
S,Fc. CP With PET Core
By 'Eosiman Chemical Co.'
OR
090' Intedayer
S.11e Clear Anti Calor Goss
By 'Eastman Chemical a."
OR
PACE 090" Intedayer
SentryGlos
By Kuramy Amarirn, Inc,'
OR
SS .090" Interlayer
Ei
B,l
BY K ,
BY 'umray Amarka, Inc'
HEAT STREN'D GLASS
i/8" HEAT STREN'O GIiSS
.075' Intedayer
1/4" AIR SPACE Soflen CP With PET Core
R'Eastman ChemicCl Cv.'
090" Interlayer
1/8" HEAT fiPEN'D GLASS -1 Sentry0lva
By °Kuraruy Amelc, Inc.'
HEAT STREN'0 GLASS
SILICONE F I SNCONE
GE 1200 - GE 1200
s m DOW CORNING 899 DOW CORNING 899
DOW CORNING 995 Mi DOW CORNING 995
\ O J 1 1 \ D
XL EDGE SPACER XL EDGE SPACER
ST. STEEL SY 'CARDINAL' �I ST. STEEL BY 'CARDINAL'
OR OR
o- DURASEAL BY 'QUANEX' 0 DRRASEAL BY QUANE('
OR
E9 7 SUPER SPACER BY 'QUANEX' W E9 SUPER SPACER BY 'QUA—'
F F
X
W M7 AT 1/4 POINTS ALL SIZES W MJ AT t/+ POINTS ALL SIZES
',LASS TYPE 'Al' GLASS TYPE 'El'
0,70° OVERALL INSUL. JAM. GLASS 0.70` 0WR ll INSUL LAM. GLASS
(S.M.I.
IN ORDER TO QUALIFY FOR SMALL MISSILE IMPACT RATING
EXTERIOR PLY OF GLASS TYPE 'At', 'Bi' & 'Cl' MUST BE TEMPERED.
F m ` SILCONE
GE
DOiZOO
W CORNING 899
Mt -
DOW CORNING 995
�v I.
I� XL EDGE SPACER
11 ST. STEEL BY 'CARDINAL'
OR
N DURASEAL BY 'QUANEX'
a OR
N E9 SUPER SPACER BY 'QUANE%'
E
/
AT 1
X IM7 4 POINTS ALL SIZES
W b
GLAss TYPE 'Cl'
0.70' DVERALL INSUL UM. GLASS
PRODUCT REVISED
HEAT STREN'D GLASS
g CodeWlfh the Florida
1/e"
075 Irdedcyer
Buildin
N0—. 17-0918.09
Sufic, CP With PET Core
Expiration Dat®09/22/2020
By'Evstmvn Chemkal Co.'
OR
.090" IntasdaYsr
Sant G
Miami- roduet Control
By 'Kuraruy America, Inc.'
,a��`.�
1/8" HEAT BTREN'D GIA55
m
SIU ONE
pice
GE 1200
`DOW CORNING 899
n
f
Mt
DOW CORNING 995
C
O
®Xao
0.
%
AT ON LfTES
W
R AN 36
WIDER THAN 36'
GLASS TYPE 'C'
5/16"
NOMINAL LAM. GLASS
i/8" HEAT STREN'O GIiSS
.075' Intedayer
1/4" AIR SPACE Soflen CP With PET Core
R'Eastman ChemicCl Cv.'
090" Interlayer
1/8" HEAT fiPEN'D GLASS -1 Sentry0lva
By °Kuraruy Amelc, Inc.'
HEAT STREN'0 GLASS
SILICONE F I SNCONE
GE 1200 - GE 1200
s m DOW CORNING 899 DOW CORNING 899
DOW CORNING 995 Mi DOW CORNING 995
\ O J 1 1 \ D
XL EDGE SPACER XL EDGE SPACER
ST. STEEL SY 'CARDINAL' �I ST. STEEL BY 'CARDINAL'
OR OR
o- DURASEAL BY 'QUANEX' 0 DRRASEAL BY QUANE('
OR
E9 7 SUPER SPACER BY 'QUANEX' W E9 SUPER SPACER BY 'QUA—'
F F
X
W M7 AT 1/4 POINTS ALL SIZES W MJ AT t/+ POINTS ALL SIZES
',LASS TYPE 'Al' GLASS TYPE 'El'
0,70° OVERALL INSUL. JAM. GLASS 0.70` 0WR ll INSUL LAM. GLASS
(S.M.I.
IN ORDER TO QUALIFY FOR SMALL MISSILE IMPACT RATING
EXTERIOR PLY OF GLASS TYPE 'At', 'Bi' & 'Cl' MUST BE TEMPERED.
F m ` SILCONE
GE
DOiZOO
W CORNING 899
Mt -
DOW CORNING 995
�v I.
I� XL EDGE SPACER
11 ST. STEEL BY 'CARDINAL'
OR
N DURASEAL BY 'QUANEX'
a OR
N E9 SUPER SPACER BY 'QUANE%'
E
/
AT 1
X IM7 4 POINTS ALL SIZES
W b
GLAss TYPE 'Cl'
0.70' DVERALL INSUL UM. GLASS
PRODUCT REVISED
g CodeWlfh the Florida
c
Buildin
N0—. 17-0918.09
Expiration Dat®09/22/2020
C F n z
� m
u
1K ao u
Miami- roduet Control
,a��`.�
pice
N
�D�m
®Xao
OE m
dog
QIM d
I
eR AhstR
V7a5aa
K
'' A tom Wi 0-18
WOOD BUCK
b " EDGE DIST:
a
O 2
mpe
EDGE I. a !"
ttPIC. ANCHORS^
v' IBY SEE DUN.
WOOD BUCK FOR SPACING
FLANGE & FLANGE ADAPTOR FRAME
..MI -CARE couN APPRGVED
MUWOI! & MUWON ANCHORS
SEE SEPARATE N.
tJ
�z 3z /B' mNulN.y
WOOD BUCKS AND METAL STRUCTURE NOT BY CGI WDW.
I
MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM
AND TRANSFER. THEM TO THE BUILDING STRUCTURE.
TYPICAL ANCHORS: SEE ELEV. FOR SPACING
>F2-3/8' MIN.
1/4" DIA TRA ON BY ' 0' (Fwt]] KSI. Fys155 NS)
�
\
WTO .1 WOOD BUCKS OR WOOD STRUCTURES
1-1/2" MIN. PENETRATION INTO WOOD (HEAD/SILL/JAMBS)
THRU 113Y BUCKS INTO CONC. OR BLOCKS
MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS)
1-1/4"
-i/4" MIN. EMBED INTO BLOCKS (JAMBS)
WHEN USED THE MIN. WOOD BUCK
CEPTH SHAH SE 2'k-• THE USE OF
DIRECTLY INTO CONCRETE OR BLOCKS
DEEPER OR SINEI£D W0009uCKS IS
1-1/4" MIN. EMBED IMO CONCRETE (HEAD/SILL/JAMBS)
PERMITTED.
1-i/4" MIN. EMBED IMO BLOCKS (JAMBS)
414 SMS OR SELF DRII LING SCREWS(GRADE 2 CRS)
INTO MIAMI-DADE COUNT' APPROVED MULLIONS
OR
INTO METAL STRUCTURES (HEAD/SILL/JAMBS)
(3) THREADS MIN. PENETRATION BEYOND SUBSTRATE
ALL1/8" THK. MIN. (6063-T5 MIN.)
PRODUCT REVISED
STEEL: 1/8" THK. MIN. (Fy - 36 KSI MIN.)
omPlyie9 with the Florida
(STEEL IN CONTACT WITH ALUMINUM TO BE PRATED OR PANTED)
Beil4in9 Code
NOA-No. 77.0918.09
TYPICAL EDGE DISTANCE
Expiration Date 09/22/2020
INTO CONCRETE AND MASONRY = 2-1/2' MIN.
B
INTO WOOD STRUCTURE = 1" MIN.
mYami-D a Pmaact control
INTO METAL STRUCTURE = 3/4" MIN.
WOOD AT HEAD, SILL OR JAMBS SG = OSS MIN.
CONCRETE AT HEAD, SILL OR JAMBS fc = 3000 PSI MIN.
C-90 HOLLDW/FlLLED BLOCK AT JAMBS f'm = 2000 PSI MIN.
WEEPHOLES:
Wl = 1/4" X 1-1/2" WEEP SLOT AT 4-1/8' FROM EACH `A1i111111111yy
END WITH PLASTIC
COVER
W2 = 1/8" X 1/2" WEEP
SLOT AT 3-1/8" FROM EACH END
W3 = 1/8" X 1/2" WEEP
SLOT AT 3-1/8" FROM EACH END
1/4" MAX.
SHIMS
TPi— ANCHORS
SEE ELEV. -
FOR SPACING
a v
w �
Q _
O�1_7 01 1 0
-SCREENS OPTIONAL---
IL��JI I
BUCKS
XOX�I. Z'}T7YOUT EXTERIOR
i/4- MAX.
SHIM
BOCK MOTH
1/4" MAX.
SHIMS
VENT W10T1
j -CAI ANCHORS
TYPICAL ANCHOR,
P.
µ0O0 STRUCTUR
SEE ELEV.
FOR SPACING
SEE ELEV.
FOR $PACING
METAL
SIRVCNRE u
'9`�---
SCREENS OPTIONAL--
- 1
E6
XD—LAYOUT
OALTERNATE -
SWEEP LACK
1 OPTIONAL TO
SPRWG LOCK
Se
E4
z FLANGE ADAPTOR FRAMEy.V -
3
FLANGE ADAPTOR FRAME 0 Z g W a
QQ $ I
t/z rm. O dodo
WNW`
Es
7
m Q
6G
0. gig
Dm
LL z ^ f n
n�
ES C
00�
� � W
g C
R 0Nn
s m
Fl
o POR SPACING INTALLATION DETAILS SHOWN ON PAGES 5
AND 6 APPLY TO BOTH FLANGE FRAME AND g
FLANGE ADAPTOR FRAMES.
-- PRODUCT REVISED 70
i an — Hand.
P Ying wi �.,
EXTERIOR WOOD BUCKS NDA No. 17-0918.09 Oe
1 Expiraeion Dale 09/22i2020 ' t DP draw' gw no
aL. OPG. DY nDP'•'tg4�® W10-18
miem�Daa/�odnae control �'''e®in�S.\��� Isneei 6 of 17J
FLANGE
1/4" MAX.
SHIMS
1 t/2 xa
2 WOOD B K
TYPICAL ANCHOR,
P.
µ0O0 STRUCTUR
SEE ELEV.
FOR SPACING
OALTERNATE -
SWEEP LACK
1 OPTIONAL TO
SPRWG LOCK
Se
E4
z FLANGE ADAPTOR FRAMEy.V -
3
FLANGE ADAPTOR FRAME 0 Z g W a
QQ $ I
t/z rm. O dodo
WNW`
Es
7
m Q
6G
0. gig
Dm
LL z ^ f n
n�
ES C
00�
� � W
g C
R 0Nn
s m
Fl
o POR SPACING INTALLATION DETAILS SHOWN ON PAGES 5
AND 6 APPLY TO BOTH FLANGE FRAME AND g
FLANGE ADAPTOR FRAMES.
-- PRODUCT REVISED 70
i an — Hand.
P Ying wi �.,
EXTERIOR WOOD BUCKS NDA No. 17-0918.09 Oe
1 Expiraeion Dale 09/22i2020 ' t DP draw' gw no
aL. OPG. DY nDP'•'tg4�® W10-18
miem�Daa/�odnae control �'''e®in�S.\��� Isneei 6 of 17J
TWICAt ANCHORS METAL EQUAL LEG FRAME J
SEE EEV. STRUCTURE
iBY FOR SPACING J a
moo BUCK ttPICAL ANCHORS ----_ ---
SEE, ELE'. PR
EDGC DIST..... °..' FOR SPACING & �r - i MULLION . MULLION ANCHORS ,� ®_ /
r pGE II SEE SEPARATE NOA EpGE
N
_ \ y
Lroc DIST.. m o- DIST. I a<� E
zoo 0.
OZ c
E5 1 \ w TYPICAL ANCHORS 0 a a
EI TYPICAL ANCHORS
SEE ELEV. 0rN5 z R
FOR SEE SPACING EYFOR SPACMG li S Z a' ,
aw
-
EQUAL LEG FRAME CAN 6E INSALLED DIRECTLY
INTO W000, CONCRETE OR METAL STRUCTURES Q w m f i
ji TYPICAL ANCHORS WITHOUT THE NEED OF A WOOD BUCK.
�t SEE ELEV. r,
FOR SPACING 2 3JE' MIN.
1/4" MAX. BUCK WIDTH
li SHIMS + PRODUCT REVISED
—1d ng GoWrth the Florida
e
NCA No. 17-09'I8.09 0iE a
1 ° + " 2-3/8° MIH. Ezpiratwn Cate 09/22/2020 n
Mlama- duct Control
O
WHEN USED THE MIN WOOD BUCK r' C 2 4 N
CEPTH SHAH BE 2J6. THE USE OF MIAMI -DAPS ION'
DEEPER OR BEY6ED WCODBUCK$ 5 APPROVED MULLION
Gi I. v J E6 PERMDTED' BUCK WIDTH SEE SEPARATENOA WIDTH .
oK
TYPICAL IIANCHORS G G I SEE ELEV. FOR SPACING
- 1
1 s 2 i
n --M9 z
I I
Wi M3 _
i !
I �`��•°TGE I°
0582 v
e O
TYPICAL PNCHORS
EDGE UISl.. :v \ ° d�e.a_, � SEE ELEV. �.-.�. '•. Op 4,/a drawing n0.
TYPICAL ANCHORS FOR SPPCING e� �•,•• Fd0'„� ®� �� rN p
>v \� SEF EDGE DIST. llll AL sheet U7 of iU1l
WOOD SUCK FOR SPACING -
ILLUSTRATNE OILS. ONLY
TYPICAL ANCHORS
SEE E1EV.
FIN FRAME
EXT. OR INT. FINISHES
FOR SPACING
NOT BY CGI
'Z
o1
El
1 1/2'
PRODCT P
Y with the REVISED
o f 2 ry
d
HOU E
PICS FE CHARS: SFOR SPACING
8
Building Code
NOA-No. 17-0918.09
a 4 C.'�
ELEV.
NOT CGi
8 S (Fu = 74 KSI MIN.)
Expiration Date 09/22/2020
1d
,42 z
t
INTO 2BY WOOD BUCKS OR WOOD STRUCTURES
eacxneD
1-1/2" MW. PENETRATION INTO WOOD
miemi- a roduc2 wnerul
v O N
Ea
CTULINNO9.9
p a
®a
Q 112
Ii.
j
O w
M
j! r
9 Cl
�
-
WOOD STRUCTURE 1/4" MAx. DUCK WIDTH
NOT BY CGI
GAP
GAP
1/2* MIN.
t/2" MIN.
O 2 N o
°1
O
tiii
z
O M I
Hili
EZ
o- n
t
BAULKED
�
j
I
u
C>ULKING
F
I
1
-KCREENSOPT.
i
W2
M9
fi
HOUSE WRAP)
NOT B CGI
..
Wt
t
EXTERIOR
W3
w
BZ E2 CAULK
CAUIxINGING
`ttNule lett7q,
HOUSE WRAP
NOT BY CCI
1 1/2"
dg o
OF
TYPICALEL
sheet 8 of 11
FOR SPACINGA��r
IyII��1\tib`
--'ITEM
PART �
RUANTCPY
DESCRIPTION
bfATERW.
MANF./SDPPLIEEfRCMIRE.S
PRODUCT REVISED
mplypng —1, the Floritla
Building tC AA
NOA-No. 17-0918.09
Expiration Date 09722/2020
By
Miami-Datle tlpct Dpntrpl
Atptil 11 UTr)] J
XAH
_%� •fie
S EOF Qgy>l:
�)��eelo�i�t`��`\
ti
��
Z m m
f "
c4i o
w N
F
d t'w n LL
»
oaoQ8
yyC N O n
a �>LL M
LL io_°
8 -
a
O.
v
E1 CGI -top - FRAME JAMB ®FIXE➢ CLASS 6053-T6 CGI EXTRUDER
E2 CGI -113 FRAME SILL 6063-T6 CGI EXTRUDER
E3 CGI -102 FRAME HEAD 6C63-Tfi CGI EXTRUDER
E4 CGI -103 - MEETING RAIL BC63-i6 CGI EXTRUDER
ES CGI -104 LOCK RAIL 6063-T6 CGI EXTRUDER
E6 CGI -105 - F14NDLE RAIL 6063-Tfi CGI EXTRUDER
E] CGI -106 - SASH RAL 6063-Tfi CGI EXTRUDER
EB CGI -10) 5/16" LAZING BEAD 6063 -TS CGI EXRRUOER
EB CGI -108 - 0.700" GLAZING BFAD 8063-T5 CGI EXIRUpER
E10 CGI -109 FRONT FIANCE ADAPTOR 6063-T6 CGI EXIRUOER
Ell CGI -110 ML FIN ADAPTOR 6063-T6 CGI EXTRUDER
Ei2 CGI -135 IF FRAME JAMB ®FlXEp GAS 6063-T6 CGI EXTRUDER
E13 CGI -136 IF FRAME HEAD 8053-Tfi CCI EXTRUDER
E14 CGI -138 IF FRAME JAMB 6063-i6 CGI EXTRI1DER
£15 CGI -140 1" MUNiIN 6063-T5 CG! EXTRUDER
EIC CGI -147 2.5" MUWON 6063-T6 CGI EXTRUDER
Et] CGI -805 BCREEN FRAME 6083-T5 CCI EXTRUDER
E18 CGI -114 SILL SNAP IN 6063-T6 CGI EXTRUDER
s
o
O
C
W
00
Q
O t h o
3N�
O M n
a 3 O
CZ4 N,
CO 4 '
Og
E19 CGI -115 - SILL FILLER 5063�T6 CGI EXTRUDER
E20 CGI -116 - FRAME JAMB 6083-T6 C6I EXTRUDER
E21 CGI -11J HQ LOCK RAIL 6063-T0 C61 E%TRUOER
E92 GGI-138 IF FRAME SILL 6063-T6 CGI EXTRUDER
E23 CGI -109 FRONT FLANGE ADAPTOR 8D63 -T6 CGI EXTRUDER
M1 Cul -382V - GfAZING BULB `ANTE (QUROMETER 75-80 SHORE A) PVC -
M2 CGI -1't SCREW COVER (OPTIONAL) PVC
M3 CGI -112 3" ® ANCHORS EQUAL LEG COVER/SHIM PVC
M4 - 0.700" X C.040" BEAD GEi200 SILICONE SILICONE GE
M5 0.700" % 0.040" BEAD DOW 995 SILICONE DOW
M8 - O.J00" X O.04D' BEAD DOW 699 SILICONE DOW
M7 - 2/ LITE SETTING BLOCK EPDM DUROMETER 8016 SHORE A
MB - - PROTECTO WRAP WATERPROOFING OR EQUN. - -
M9 684 ROLLER TR.1DK PVC
M10 CGI -128 2 P£ft SASH ROLLER HOUSING NYLON
Gzz
dg
U
5
M11 W23201 NG PILE WITH CENTER FIN L ULTRAFAB OR EWN.
�AALU..
M12 CGI -129 1 PER SASH EGRESS LOCK 6ULIJVAN
M13 CGI -131 2PER 6p<H HANDLE RAIL END LAP N M&M
M14 391-N 1 PER SASH ANiILIFi BLOCK N M&M
M15 OPTIONAL RETICULATED FOAM 30 PPI
M16 CCI -134 JMIB SPACER PVC PROTOTYPE OR
EEWIV.1 PER WD. CAM LOCK 21NC TRUTH OR EQ
M18 CGI -132 2PER W0. 2" SASH STOP PVC PROTOttPE
M19 CGI -t11 ® FR. HE>D SCREW COVER PVC PROTOTYPE
M20 CGI -115 2PER SASH SASH CAM (B/T BALANCE) NYLON MkM
M22 VARIFS H -PLO WEEP CO4EA8 PVC AM6BURY oft EpUIV
S2 2 OR 3 PER CORNER / t0 X 1 t/4" LG. PHL PH. SMS. ST/5T. ASGEMBLY SCREW
53 - 1 if4" EMBEC. � 8 X 1 1/2" LG. PHL PR. SMS. FIN ANCHOR SCREW -
Fb
dr i 9
W110-18
sheet 9 Gftt
4-- � 8 X t/Z" PH. SMS. ST/ST BALANCE BRACKET SCREW -
54 -
55 2PER W0. � 8 % i" LG. FH. SMS Si/ST. SPIRAL B. ASSEMBLY - -
Sfi $ 6 X tf2° LG. fli. SMS, ®CGI -733 &CAM LOCK
� - 4 ®M. RP)L $ 10 X 4" LG. PHIL, PH. SMS. ST/5T. ASSEMBLY MEETING RAIL - -
59 2PER ANIILIFT � 10 X 5/B" W.
PHL, PH. SMS. ST/ST. ANTIJFT SCREW
-
'
2101
2.846
E13 FLANGE
�2.4ao--{I
I
0G5 1.301
ttP.
�
1.155-i
I
1.015 F-
FRAME HEAD
III- 2;440
1.601
2:346 NP.
1,155
tots I V-
[a FLUSH FRAME HEAD
2.11-�
-3
tats {j
1.220 1.007
085
TP.
1.368 .745
Ea MEETING RAIL
po .12-11
-y�.M •a -'
.7os�f 050 IYP. .705 .Oso TYP.
550 1.�0 -d .864 .BfiA
.050 E9 5/16" GLAZING BEAD O .700" GLAZING BEA)
1.395
Ett NAIL FIN ADAPTER t3s5
1 ase �I 180 293
.050 .060 1.413--I
2.264 1255 M3 FLUSH FRAME COVER Mz SCREW COVER
.060
�
Et9 SILL FILLER
O FLANGE ADAPTOR
Z J
o yZj �j
Q 2 i n Qi
� � No � °
`�
WW
C i
(� o
®a a a Wg
N Q a
Q w w
4.430
En
3.685
1.Ct5
065
TYP.
2'885
FRAME SILL
3.930
3'786
O FLUSH
1.015
1.141
.065
�2.885
FRAME SILL
1.786-b
F
I 7.015 1.220
L_
1.C43
O LOCK RAIL
e
�
a
y
o
3 n
z N
a V
U
1.788
tot sI T0.6�5
.4
1.043
E21 ALT. LOCK RAIL
O
2.310
1220
FLANGE
r-2.737
.065
TYP.
,
[ -2.737
066
TTP.
�
1.892
085
+I1,('-'' I�`'TJ�}ra.
1.015
U 5
1043
ES HANDLE RAIL
2.505
2.813
2.505 2613
.500 .991 �1
2.737
�0
FLUSH FRAME JAMB (MOVING)
PRODUCT REVISED
building lC°d with the Florida
NOA-N°, 17-0918.09
Explration Oats° /2212020
ey
Miami-0atl r duct Control
`AAI\Ill I111t/�'/'
\` �•.�•.�,�® iii
1
_ - ,• �- T6� df4�
ftp°'
7�'®III WO
I N
w y+'SS1
y b II
Y $
Ido $.o
',. draw n9 0.
W10-18
1.000 .991
E74 FLANGE FRAME JAMB (MOVING)
811
2.505 .065 TIP.
t.01�
1.000
1.745
12 FLANGE FRAME JAMB (FIXED)
611 1^-
1.01
.500
1.245
Et FLUSH FRAME JAMB (FIXED)
"� 1.025
1.395Ll
.745
1.015 F-
O SASH RAIL
sheet 10 of 11.
M�.DUCT REVISED
� � �\
/���\ �|�\
. - .
j .C' M
77 �|
a M
FRAME IOE CORNER
{\ ƒ
� ■ /
VENT TOP/80710M :g { � [
\/\{
£ 7 «
�\ 70592
_ MTG. m _e %! #�