Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL (2) -. F SCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBc Staff BCIS Site Map Links Search e �,Product Approval USER:Public User Product Approval Menu>Product or Application Search>Application Us t>Application Detail FL# FL10674-R13 Application Type Revision Code Version 2017 Application Status Approved Comments Archived I Product Manufacturer Owens Coming Address/Phone/Email One Owens Corning Parkway Toledo,OH 43659 (740)404-7829 greg.keeler@owenscoming.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Coming PKWY Toledo,OH 43659 (419)376-8360 mei.sancrent@owenscomig.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert J.M.Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 05/16/2020 Validated By John W. Knezevich,PE Validation Checklist-Hardcopy Received Certificate of Independence FL10674 R13 COI 2017 01 COI Nieminen pdf Referenced Standard and Year(of Standard) Standard Year ASTM D3161 2016 ASTM D3462 2010 ASTM D7158 2011 Equivalence of Product Standards Certified By Sections from the Code https://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgtBNbEYSVp/o2boQTp/o2b6w7ahReglCQ8ucR6!xEBFhs7tvJgzew%3d%3d 1/2 f Florida Building Code Online Product Approval_Method Method 1 Option D Y✓ Date Submitted 10/10/2017 Date Validated 10/11/2017 Date Pending FBC Approval 10/15/2017 Date Approved 12/12/2017 Summa of Products i FL# Model,Number or Mame Description 10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab,5-tab,laminated,starter and hip&ridge shingles Shingles and Starters Limits of Use Installation Instructions Approved for use in HVHZ:No F"0674 R13 II 2017 10 FINAL ER OC ASPHALT Approved for use outside HVHZ:Yes SHINGLES FL10674-R13.pdf Impact Resistant: N/A Verified By: Robert J. M.Nieminen PE-59166 Design Pressure:N/A Created by Independent Third Party:Yes Other: Refer to ER,Section S. Evaluation Reports FL10674 R13 AE 2017 10 FINAL ER OC ASPHALT SHINGLES FI10674-R13.pdf Created by Independent Third Party:Yes EE I Contact Us::2601 Blair Stone Road,Tallahassee Fl.323W Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Cooyrioht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,FS.,please click Lm_-. Product Approval Accepts, iru• —;.1 ® igm Ctctt Credit Card Safe i httosJ/www.loridabuildinq.ora/Dr/or aoD dtl.asDxtoaram=wGEVXQwtDotBNbEY5V%2boQT%2b6w7ahRealCORur.RFiYFRFhr7fv.1n7=weigrtoi'At+ ��� t ' f TRNTY ERD 5.4 Wind Classification: 5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H, indicating the shingles are acceptable for use in all wind zones up to Vasd = 150 mph (Vult = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F, indicating the shingles are acceptable for use in all wind zones up to V.d=150 mph(V„It= 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D71S8 applies to exposure category B or C, as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.,4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 6111320-3,per FBC 1507.2.3,1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: Berkshire®shingles require minimum five(5)nails per shingle. WeatherGuard®HP shingles require minimum six(6)nails per shingle. ➢ Devonshire'"'shingles require minimum six(6)nails per shingle. Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. See figures below for details. 6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus: -.i, Deck Sel&adhered Feltumderlayment r(S_ Dec}: I&andedayment WeatherlackpP) "?• Sell-adhered undadayment WeatherLock' undcrlayment (; ! - �� � �•'�� Oripedge DDrip edge Drip- edge / edge locatedNadsloeated Nails located m eave 23'from eave Install first Self-sealing adhesive Sall+.aefing adhesive Starter Strip positinnedalongeave MswOfrstStarter.Sniptahrs posRianedalong eave shingle with wilts s'removed 6"removed Starter Strip ling le eye rhangseaves and rakes'i' V starlerSrlipFlus overhangs eaves and rakasl/4=3/•s" Exterior Research and Design,LLC. Evaluation Report 037940.02.12-118 Certificate ofAuthorization#9503 6t't EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1113 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 3 of 8 6.2.6 Minimum Nailing—Classic®fit.Supreme: Normal Mansard or Area para P ao... Mansard or Area para Wind Areas High Wind desvenes y High Wind desvanes y Area para vientos normales Areas vientos foerres tos normales Areas vientos fuertas fAl 9r72 {B) r2° !5°Exposure reExpoaieion eidn 6.2.7 Minimum Nailing—Berkshire®: Sealant strip Sealant strip La t8a de sAdm La Lira de sellador Q---0 o.----+ 911f 9.w 8 Y/" f 8 Wa W 8 11Y. 8w, j to 1"J 7 VJ 0 Standard Fastening Pattern 6-Nail Fastening Pattern Sealantstrip La Bra de sellader oE---------no 4-----a a 04-------->© 0 7 1" 8 e ze Asphalt roofing cement Cementode Who do Watto Mansard or Steep Slope Fastening Pattern Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R8 Certificate of Authorization#9503 67H EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1113 Owren Coming Asphalt Roof Shingles Revision 8:10/09/2017 Page 4 of 8 4 TRNW ERD 6.2.8 Minimum Nailing—Devonshire"": 81, 7" (jot Nails H/8"exposureSealant location !Exposici6n.do 5.5/8 puli; Ubicacf6n del Sell3dDr %------ Ton 1"Spots of Asphalt Roof Cement Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern 6.2.9 Minimum Nailing — Duration®, TruDefinition® Duration, DurationO Premium Cool & TruDefinition Duration Designer Color Collection: 4-Nall Fastening Pattern Mail Fastening Pattern sureNallo fastening area width SweNallo fastening area wWm Nall.Typical Nag.Typical 1;r ir 1z' cam Fl- E� I F Standard Fastening Pattern 6-Nail Fastening Pattern Fastening for Slopes Greater Than 21.12 SumllalK)fastening'—d"th r Nall.Typical 12' ir -71-) I —T, Pour v'spots afAsphalt Roeting cement Mansard or Steep Slope Fastening Pattern Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R8 Certificate of Authorization#9503 6TN EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1113 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 5 of 8 T'RINBIY I ER® 6.2.1 Minimum Nailing—TruDefinition®Oakridge°,Oakridge®: 4 Nail Pattern 6 Nail Pattern Esquenia con 4 clavus Esquema can 6 clalros 1" 1z" i 55/$"Exposure Nags SSffExposute Nails Erposicldn&66/8pul4 Claves ExposIdinde65/8pdg. 5518"Exposure Clavus 5518"Exposu2 &PbOddn de 6610 puig. Evos'Wn de 56/9puig. I Standard Fastening Pattern 6-Nail Fastening Pattern Fastening for Slopes Greater Than 21:12 rr SureNag.A fastening area width �Nell,Typical 1" 12" .■.v.n[vve WJ.J •... NuvJ •O..MCv •. � Y f &1111" -f2 Four 1"Spot"OtAephag RoOpng cement Mansard or Steep Slope Fastening Pattern 6.2.1 Minimum Nailing—WeatherGuard®HP: I �■ i1n019 Ode View fes- !•��r. `ter .� WIN&lid Antum W-0Cfw�whrY�trr tiNd l�din Exterior Research and Design,U.C. Evaluation Report 037940.02.12-118 Certificate of Authorization#9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R33 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 6 of 8 `ERIN ERD 6.3 Hip&Ridae Shingles: 6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, WeatherGuard® HP Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the Owens Corning current published instructions, using four (4) nails per shingle. Installation of DuraRidgel Hip & Ridge Shingles shall comply with the Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand-sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2°6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge: Fig.1 4 Fig.2 �- P`eraipngV4lnd Direction ,v 1 1Top View SitleV'iety \ A Nails—`—�y Nals Nails 4 \ - 7 I Top Laminated A I 1 4" Piece I I n '• A .. � � i I I I `1 Exposure I I I• I \\ 14- 12 6.3.4 Minimum Nailing—WeatherGuard®HP Hip and Ridge: Fig.,4 9 Fig.C Hip&Ridge Shingle Fastening 44 PmvatlNg Wind /\ Top Vlevi &—Dtrectbn Nails 4 4 \� A \ A\ I I Nails Nails A I T 2" 2" I Exposure >, Exposure \ � 12" Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-Rg Certificate ofAuthorizorion#9503 6T"EDITION(2017)FSC NON-HVHZ EVALUATION F1.10674-1113 Owens Coming Asphalt Roof Shingles Revision R:10/09/2017 Page 7 of 8 , TRINITY ERD 6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles: Prevai0ing Standard 19" Wind Direction Fastening Soalnnt Strip Pattern �-® 6°Exposure ~,I 1-1 t4' f Sealant Fasten 711,° Th" 6"Exposure Cover Exposed Fasteners with Roof Cement i 6.3.6 Minimum Nailing—DuraRidge'm Hip&Ridge Shingles: Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. prom Ing Wind Ditococn V'1(.o aVic.. °---'Diroaion d=imritow ccncph Dir•�I' �tscr:up.`nar 1'Lrr rocdendalAcnto prod-.rnimnco r:d —"c 2 tie' rac- tt.u6 �- �y- e� `�Y__' � Oarone Coniltgl S+uellail' i rlou: ;a �' > 3 R .Im t 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. S. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625;(631)546-2458;Kanchi.Agrawala-Dokania@ul.com END OF EVALUATION REPORT- Ettterior Research and Design,U.C. Evaluation Report 037940.02.12-R8 Certificate ofAuthoriration#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017 Page 8 of 8