Loading...
HomeMy WebLinkAboutProduct Approval 398 East Dania Beach Blvd. BUILDING DROPS Suite 338 µE Dania Beach, 33004 A Perfect Solution in Every Drop! 954.399..88 478 PH Certificate of Authorization:29578 954.744.4738 FX contact@buildingdrops.com Product Evaluation Report RECEIVED Of MAR 0 8 2099 JELD-WEN, inc. ST, Susie County, Permitting: Design Pro/Smooth Pro Fiberglass Non-Impact Glazed Doors For use in the High Velocity Hurricane Zone (HVHZ) for Florida Product Approval Report No. 4430.1 Current Florida Building Code Method: 1—D (Engineering Evaluation) Category: Exterior Doors Sub—Category: Swinging Exterior Door Assemblies Product: Design Pro/Smooth Pro Fiberglass Non-Impact Glazed Doors For use in the High Velocity Hurricane Zone Material: Fiberglass Product Dimensions: 3'-0"X 6-r(Nominal) 3'-0"X 8'-0"(Nominal) Prepared for: JELD-WEN, inc. 3737 Lakeport Blvd. ���� �g F. 0���i,� Klamath Falls, OR. 97601 .`� Q- .•••... . .�`,p'e: Prepared by: 0 ' 7 Hermes F. Norero, P.E. Florida Professional Engineer#73778 = -o - T T / ► Date:11/15/2017 �O '•• (p4/ Date: Contents: �� �`S,•••••.....••. Evaluation Report Pages 1-4 ��i `S�ONAXL Digitally signed by Hermes F.Norero,P.E. Hermes�lf 1i IQ, P.E. Reason:I am approving this document Florida No.73778 Date:2017.11.1710:11:09-05'00' 1 BUILDING DROPS A Perfect.Solution in Every Drop! Date: 11/15/2017 Certificate of Authorization:29578 Report No: 4430.1 Manufacturer: JELD-WEN,Inc. Product Category: Exterior Doors Product Sub-Category: Swinging Door Assemblies c Compliance Method: State Product Approval(1)(d) Product Name: Design Pro/Smooth Pro Fiberglass Non-Impact Glazed Doors For use in the High Velocity Hurricane Zone(HVHZ) 3'-0"X 6'-8"(Nominal) 3'-0"X 8'-0"(Nominal) Scope: This is a Product Evaluation Report issued by Hermes F. Norero,P.E.(FL#73778)for JELD-WEN inc. based on Method id of the Florida Department of Business and Professional Regulation -Florida Building Commission. Hermes F.Norero,P.E.does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the current Florida Building Code. See Installation Instructions A010862,signed and sealed by Hermes F. Norero,P.E.(FL#73778)for specific use parameters. Limits of Use: 1. This product has been evaluated and is in compliance with the current Florida Building Code, includins the"High Velocity Hurricane Zone"(HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Chapter 16 of the current Florida Building Code and does require an impact resistant covering. 4. Site conditions that deviate from the details of drawing A010862 require further engineering analysis by a licensed engineer or registered architect. 5. See Installation Instructions A010862 for size and design pressure limitations. Hermes F. Norero, P.E. Florida No.73778 Page 2 of 4 BUILDING DROPS h A Perfect Solution in Every Drop! Date: 11/15/2017 Certificate of Authorization:29578 Report No: 4430.1 Quality Assurance Entity: The manufacturer has demonstrated compliance of products in accordance with the Florida Building Code for manufacturing under a Certification Agency through National Accreditation&Management Institute(FBC Organization#QUA1789) Performance Standards: The product described herein has been tested per: • TAS 202-94 Referenced Data: 1. Product Testing performed by National Certified Testing Laboratories (FBC Organization#TST1589) Report# Report Date: NCTL-210-3916-02 10/10/13 NCTL-210-3918-03 10/12/13 NCTL-210-3918-02 10/12/13 NCTL-210-3924-01 12/18/13 NCTL-210-3925-03 02/07/14 NCTL-210-3916-02 10/10/13 NCTL-210-3916-02 w/addendum. 06/10/14 NCTL-210-3930-01 02/24/14 NCTL-210-3930-02 03/10/14 All reports signed and sealed by Gerard J.Ferrara,FL P.E. No 11985 Report# Report Date: SJW2013-246 12/17/13 SJW2013-251 12/23/13 SJW2013-252 12/23/13 SJW2013-253 12/23/13 SJW2014-032 04/22/14 SJW2014-073 06/26/14 SJW2014-077 06/27/14 SJW2014-072 06/27/14 SJW2014-080 07/03/14 All reports signed and sealed by Robert H.Zeiders,P.E. Report# Report Date: SJW2013-194 w/addendum 06/10/14 All reports signed and sealed by Kevin P.Tyra, P.E. Report# Report Date: SJW2016-006 02/22/16 All reports signed and sealed by Harold E.Rupp,FL P.E. No 15935 Hermes F.Norero, P.E. Florida No.73778 Page 3 of 4 BUILDING DROPS 3 Date: 11/15/2017 A Perfect Solution in Every Drop! Certificate of Authorization:29578 Report No: 4430..11 2. Quality Assurance Entity National Accreditation&Management Institute (FBC Organization#QUA1789) 3. Component Material Testing of Dylite Expandable Polystyrene by Intertek Testing Services NA,Inc. ASTM E84 Report#:3113726SAT-001 R1 Report Date:03/13/09 4. Component Material Testing of Fiberglass SMC Skin Element Materials Technology ASTM D635,ASTM D638,ASTM D1929,ASTM D2843,ASTM G155 Report#: ESP010982P Report Date:02/26/13 Installation: 1. Approved anchor types and substrates areas follows: Through Frame Installation: A. For two by(2X)wood buck substrate(Min.S.G.=0.55),use#10 Wood Screw type installation anchors of sufficient length to achieve a minimum embedment of 1.50"into the wood substrate. B. For concrete(Min.f c=3000 psi)or masonry(Conforms to ASTM C90)substrate where one by(1X),non-structural,wood bucking is employed,use 3/16"diameter ITW Tapcon --- or%I'Elco Ultracon type concrete screw anchors of sufficient length to achieve minimum embedment of 1.25"into concrete or masonry. C. For concrete(Min.fc=3000 psi)or masonry(Conforms to ASTM C90)substrate where wood bucking is NOT employed,use 3/16"diameter ITW Tapcon or Y,"Elco Ultracon type concrete screw anchors of sufficient length to achieve minimum embedment of 1.25"into concrete or masonry. Refer to Installation Instructions(A010862)for anchor spacing and more details of the installation requirements. Design Pressure: Refer to Installation Instructions(A010862)for design pressures based on size&configuration of door units. Hermes F.Norero, P.E. Florida No.73778 Page 4 of 4