HomeMy WebLinkAboutNOA 1
NEMO|etc.
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203) 262-9245
ENGINEER EVALUATE TEST CONSULT CERTIFY
EVALUATION REPORT
CertainTeed Corporation
20 Moores Road
Malvern, PA 19355
(610) 651-5847
Evaluation Report 3520.03.04-R21
FL2533-R20
Date of Issuance: 09/19/2005
Revision 21: 06/20/2018
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 6th Edition (2017) Florida Building Code sections noted herein.
DESCRIPTION: Flintlastic® Modified Bitumen Roof Systems
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to
the product(s), the Quality Assurance or the production facility location(s). NEMO|etc. requires a complete review of
this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words “NEMO|etc. Evaluated” may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6, plus a 57-page Appendix.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized by Robert
Nieminen, P.E. on 06/20/2018. This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing produ cts for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO|etc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL2533-R20
CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Revision 21: 06/20/2018
Page 2 of 6
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Modified Bitumen Roof Systems
Compliance Statement: Flintlastic® Modified Bitumen Roof Systems, as produced by CertainTeed Corporation,
have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code through
testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and
Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1504.3.1 Wind FM 4474 2011
1504.7 Impact FM 4470 2012
1507.11.2 Physical Properties ASTM D6162 2008
1507.11.2 Physical Properties ASTM D6163 2008
1507.11.2 Physical Properties ASTM D6164 2011
1507.11.2 Physical Properties ASTM D6222 2011
1507.11.2 Physical Properties ASTM D6509 2009
3. REFERENCES:
Entity Examination Reference Date
ERD (TST6049) FM 4470 3504.06.01-1 06/05/2001
ERD (TST6049) FM 4470 3513.08.02 08/15/2002
ERD (TST6049) FM 4470 03515.07.03 07/22/2003
ERD (TST6049) FM 4470 3519.12.03 12/22/2003
ERD (TST6049) FM 4470/4474 3522.07.04 07/28/2004
ERD (TST6049) FM 4470/4474 02843.02.05-11 02/10/2005
ERD (TST6049) FM 4470/4474 3533.01.06 01/06/2006
ERD (TST6049) FM 4470/4474 4674.11.01-1 03/21/2006
ERD (TST6049) Physical Properties 3535.10.06 10/31/2006
ERD (TST6049) FM 4470/4474 3521.07.04-R1 10/26/2007
ERD (TST6049) FM 4470/4474 02764.09.05-R1 12/10/2007
ERD (TST6049) FM 4470/4474 02762.03.05-R1 12/10/2007
ERD (TST6049) Physical Properties C7290.01.08 01/16/2008
ERD (TST6049) Physical Properties C10080.09.08 09/04/2008
ERD (TST6049) FM 4470/4474 C8370.08.08-R1 10/05/2009
ERD (TST6049) FM 4470/4474 P6860.06.07-R1 09/10/2009
ERD (TST6049) FM 4470/4474 C30310.12.09 12/17/2009
ERD (TST6049) FM 4470/4474 C30560.03.10 03/18/2010
ERD (TST6049) FM 4470/4474 C31420.08.10 09/21/2010
ERD (TST6049) FM 4470/4474 C33980.12.10 12/22/2010
ERD (TST6049) FM 4470/4474 C33830.02.11 02/08/2011
ERD (TST6049) TAS 117(B), Rupture C35500.02.11 02/09/2011
ERD (TST6049) FM 4470/4474 C37820.07.12 07/24/2012
ERD (TST6049) FM 4470/4474 C37830.07.12 07/26/2012
ERD (TST6049) Physical Properties C42110.08.12 08/13/2012
ERD (TST6049) FM 4470/4474 C39670.08.12 08/20/2012
ERD (TST6049) FM 4470/4474 C42280.08.12 08/20/2012
ERD (TST6049) TAS 117(A) A35880.04.12-R1 10/26/2012
ERD (TST6049) FM 4470/4474 C44580.07.13 07/25/2013
ERD (TST6049) FM 4470/4474 C46090.11.13-A 11/20/2013
ERD (TST6049) FM 4470/4474 C45620.03.14 03/27/2014
ERD (TST6049) FM 4470/4474 C46760.06.14 06/19/2014
ERD (TST6049) FM 4470/4474 C47320.03.14-R1 04/01/2015
ERD (TST6049) FM 4470/4474 CTR-SC8995.10.15 10/14/2015
ERD (TST6049) FM 4470/4474 CTR-SC9935.01.16 01/14/2016
ERD (TST6049) FM 4470 CTR-SC9920.01.16-R1 01/20/2016
ERD (TST6049) FM 4470/4474 CTR-SC10420.01.16 01/25/2016
ERD (TST6049) FM 4470/4474 CTR-SC9175.09.16-1 09/06/2016
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL2533-R20
CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Revision 21: 06/20/2018
Page 3 of 6
Entity Examination Reference Date
ERD (TST6049) FM 4470/4474 CTR-SC9175.09.16-1 09/06/2016
ERD (TST6049) FM 4470/4474 CTR-SC11590.08.16-R1 09/06/2016
ERD (TST6049) FM 4470/4474 CTR-SC12255.12.16 12/27/2016
ERD (TST6049) FM 4474 CRT-SC15775.17 09/13/2017
FM Approvals (TST1867) FM 4470 0E3A2.AM 03/30/1982
FM Approvals (TST1867) FM 4470 3W0A4.AM 03/16/1993
FM Approvals (TST1867) FM 4470 3W0A2.AM 03/17/1993
FM Approvals (TST1867) FM 4470 3W0A3.AM 03/17/1993
FM Approvals (TST1867) FM 4470 1Z4A6.AM 09/11/1996
FM Approvals (TST1867) FM 4470 3Y8A1.AM 09/30/1996
FM Approvals (TST1867) FM 4470 2D5A9.AM 06/22/1999
FM Approvals (TST1867) FM 4470 3009502 12/12/2000
FM Approvals (TST1867) FM 4470 3008869 03/19/2001
FM Approvals (TST1867) FM 4470 3009610 10/15/2001
FM Approvals (TST1867) FM 4470 3006025 12/28/2001
FM Approvals (TST1867) FM 4470 3012321 07/29/2002
FM Approvals (TST1867) FM 4470 3009814 09/06/2002
FM Approvals (TST1867) FM 4470 3014502 04/04/2003
FM Approvals (TST1867) FM 4470 3015444 07/11/2003
FM Approvals (TST1867) FM 4470 3014692 08/05/2003
FM Approvals (TST1867) FM 4470 3014751 08/27/2003
FM Approvals (TST1867) FM 4470 3018579 10/09/2003
FM Approvals (TST1867) FM 4470/4474 3020703 07/30/2004
FM Approvals (TST1867) FM 4470/4474 3021759 06/03/2005
FM Approvals (TST1867) FM 4470/4474 3022038 04/05/2006
FM Approvals (TST1867) FM 4470/4474 3023458 07/18/2006
FM Approvals (TST1867) FM 4470/4474 3026128 08/04/2006
FM Approvals (TST1867) FM 4470/4474 3024311 11/01/2006
FM Approvals (TST1867) FM 4470/4474 3025766 11/13/2006
FM Approvals (TST1867) FM 4470/4474 3028410 02/19/2007
FM Approvals (TST1867) FM 4470/4474 3026964 07/25/2007
FM Approvals (TST1867) FM 4470/4474 3031262 11/30/2007
FM Approvals (TST1867) FM 4470/4474 3031199 12/23/2008
FM Approvals (TST1867) FM 4470/4474 3032172 06/12/2009
FM Approvals (TST1867) FM 4470/4474 3037127 01/11/2010
FM Approvals (TST1867) FM 4470/4474 3039848 12/02/2011
FM Approvals (TST1867) FM 4470/4474 3046104 08/13/2013
FM Approvals (TST1867) FM 4470/4474 3048520 09/19/2013
FM Approvals (TST1867) FM 4470/4474 3055491 12/05/2016
MTI (TST2508) Physical properties DX08C4A 03/22/2004
MTI (TST2508) Physical properties DX20E3A 03/22/2004
MTI (TST2508) Physical properties DX20E3A-001 01/04/2006
MTI (TST2508) Physical properties AX31G8A 08/21/2008
MTI (TST2508) Physical properties AX31G8D 09/05/2008
MTI (TST2508) Physical properties AX31G8F 06/05/2009
MTI (TST2508) Physical properties AX21G8C 01/28/2011
PRI (TST5878) Physical Properties CTC-032-02-01 01/16/2008
PRI (TST5878) Physical Properties CTC-034-02-01 11/24/2008
PRI (TST5878) Physical Properties CTC-066-02-01 08/08/2011
PRI (TST5878) Physical Properties CTC-067-02-01 08/08/2011
PRI (TST5878) Physical Properties CTC-068-02-01 08/08/2011
PRI (TST5878) Physical Properties CTC-070-02-01 08/08/2011
PRI (TST5878) Physical Properties CTC-071-02-01 08/08/2011
PRI (TST5878) Physical Properties CTC-093-02-01 08/08/2011
PRI (TST5878) Physical Properties CTC-116-02-01 04/03/2012
PRI (TST5878) Physical Properties CTC-183-02-01 10/04/2013
PRI (TST5878) Physical Properties CTC-259-02-01 12/11/2015
UL, LLC. (QUA9625) Quality Assurance Service Confirmation, R11656 03/09/2017
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL2533-R20
CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Revision 21: 06/20/2018
Page 4 of 6
4. PRODUCT DESCRIPTION:
This Evaluation Report covers Flintlastic® Modified Bitumen Roof Systems installed in accordance with CertainTeed
Corporation published installation instructions and the Limitations / Conditions of Use herein. The following
CertainTeed products make up the subject systems.
TABLE 1: ROLL-GOODS FOR FLINTLASTIC® MODIFIED BITUMEN ROOF SYSTEMS
TYPE PRODUCT SPECIFICATION
REFERENCE GRADE TYPE
Base Sheets
Flintlastic® SA NailBase ASTM D4601 N/A II
Glasbase™ Base Sheet ASTM D4601 N/A II
All Weather/Empire™ Base ASTM D4601 N/A II
Flexiglas™ Base ASTM D4601 N/A II
Flintlastic™ Base 20 ASTM D4601 N/A II
Flintlastic Poly SMS Base Sheet ASTM D4601 N/A II
Yosemite® Venting Base ASTM D4897 N/A II
Ply Sheets Flintglas® Ply 4 ASTM D2178 N/A IV
Flintglas® Premium Ply 6 ASTM D2178 N/A VI
Base/Ply Membranes (APP)
Flintlastic® APP Base T ASTM D6509 N/A N/A
Flintlastic® STA ASTM D6222 S I
Flintlastic® STA Plus ASTM D6222 S I
Cap Membranes (APP)
Flintlastic® STA ASTM D6222 S I
Flintlastic® STA Plus ASTM D6222 S I
Flintlastic® GTA ASTM D6222 G I
Flintlastic® GTA CoolStar™ ASTM D6222 G I
Flintlastic® GTA-FR ASTM D6222 G I
Flintlastic® GTA-FR CoolStar™ ASTM D6222 G I
Base/Ply Membranes (SBS)
Flintlastic® SA PlyBase ASTM D1970 N/A N/A
Black Diamond® Base Sheet ASTM D1970 N/A N/A
Flintlastic® SA Mid Ply ASTM D6163 S I
Flintlastic® Ultra Glass SA ASTM D6163 S I
Flintlastic® Base 20 ASTM D6163 S I
Flintlastic® Base 20 T ASTM D6163 S I
Flintlastic® Ultra Poly SMS Base Sheet ASTM D6164 S I
Cap Membranes (SBS)
Flintlastic® FR Dual Cap ASTM D6162 G I
Flintlastic® SA Cap FR ASTM D6163 G I
Flintlastic® SA Cap FR CoolStar™ ASTM D6163 G I
Flintlastic® Cap 30 ASTM D6163 G I
Flintlastic® Cap 30 CoolStar™ ASTM D6163 G I
Flintlastic® FR Cap 30 ASTM D6163 G I
Flintlastic® FR Cap 30 CoolStar™ ASTM D6163 G I
Flintlastic® FR Cap 30 T ASTM D6163 G I
Flintlastic® FR Cap 30 T CoolStar™ ASTM D6163 G I
Flintlastic® SA Cap ASTM D6164 G I
Flintlastic® SA Cap CoolStar™ ASTM D6164 G I
Flintlastic® FR-P ASTM D6164 G I
Flintlastic® FR-P CoolStar™ ASTM D6164 G I
Flintlastic® GMS ASTM D6164 G I
Flintlastic® GMS CoolStar™ ASTM D6164 G I
Flintlastic® GTS ASTM D6164 G II
Flintlastic® GTS CoolStar™ ASTM D6164 G II
Flintlastic® GTS-FR ASTM D6164 G II
Flintlastic® GTS-FR CoolStar™ ASTM D6164 G II
Flintlastic® Premium FR-P ASTM D6164 G II
Flintlastic® Premium FR-P CoolStar™ ASTM D6164 G II
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL2533-R20
CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Revision 21: 06/20/2018
Page 5 of 6
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither NEMO|etc. nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in HVHZ jurisdictions.
5.3 Refer to a current UL Roofing Materials Directory for fire ratings of this product.
5.4 For steel deck installations, foam plastic insulation shall be separated from the building interior in accordance with
FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply.
5.5 The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members
shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load
resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation.
5.6 For recover installations, the existing roof shall be examined in accordance with FBC 1511.
5.7 For mechanically attached insulation or membrane or strip-bonded insulation, the maximum design pressure for the
selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16.
Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated
pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing
Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk*
carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone
2/3 enhancements.
5.8 For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly
shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is
permitted for these systems.
5.9 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the existing
deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the
minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing
Application Standard TAS 105.
5.10 For bonded insulation or membrane over existing substrates in a re-roof (tear off) or recover installation, the
existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any
surface conditions exist that bring system performance into question, field uplift testing in accordance with
ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124 shall be
conducted on mock-ups of the proposed new roof assembly.
5.11 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall
be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having
Jurisdiction, as documented through field uplift testing in accordance with ASTM E907, FM Loss Prevention Data
Sheet 1-52 or Testing Application Standard TAS 124.
5.12 Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance with FBC
Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or Roofing Application Standard RAS 111,
except the basic wind speed shall be determined from FBC Figure 1609.3(1), 1609.3(2) or 1609.3(3).
5.13 All products in the roof assembly shall have quality assurance in accordance with FAC Rule 61G20-3.
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL2533-R20
CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Revision 21: 06/20/2018
Page 6 of 6
6. INSTALLATION:
6.1 Flintlastic® Modified Bitumen Roof Systems shall be installed in accordance with CertainTeed Corporation
published installation instructions, subject to the Limitations / Conditions of Use herein.
6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. ”MDP” = Maximum Design
Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate
passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC
1609 for determination of design wind loads.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements.
9. QUALITY ASSURANCE ENTITY:
UL, LLC. – QUA9625; (414) 248-6409, karen.buchmann@us.ul.com
- THE 57-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT -
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 1 of 57
APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE
TABLE DECK APPLICATION TYPE DESCRIPTION PAGE
1A Wood New or Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 5-6
1B Wood New, Reroof (Tear-Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 7
1C Wood New, Reroof (Tear-Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 8-9
1D Wood New, Reroof (Tear-Off) or Recover D Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 10-12
1E-1 Wood New, Reroof (Tear-Off) E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 13-15
1E-2 Wood New, Reroof (Tear-Off) or Recover E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 16-17
1F Wood New or Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 17
2A Steel or Structural Concrete New, Reroof (Tear-Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 18-20
2B Steel or Structural Concrete New, Reroof (Tear-Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 21-25
2C Steel or Structural Concrete New, Reroof (Tear-Off) or Recover D Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 26-28
3A Concrete New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 29-36
3B Concrete New or Reroof (Tear-Off) A-3 Bonded Temp Roof/Vapor Barrier, Bonded Insulation, Bonded Roof Cover 36
3C Concrete New or Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 37
4A LWIC New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 38-39
4B LWIC New or Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 40
4C LWIC New, Reroof (Tear-Off) E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 41-44
5A CWF New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 45
5B CWF New or Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 46
5C CWF New, Reroof (Tear-Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 46
5D CWF New, Reroof (Tear-Off) E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 47
6A Gypsum Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 48-49
6B Gypsum Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 50
6C Gypsum Reroof (Tear-Off) C Mech. Attached Insulation, Bonded Roof Cover 51
6D Gypsum Reroof (Tear-Off) E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 51
7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 52-57
7B Various Recover F Non-Insulated, Bonded Roof Cover 57
The following notes apply to the systems outlined herein:
1. The roof system evaluation herein pertains to above-deck roof components. Roof decks shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the
roof deck shall be documented through proper codified and/or FBC Approval documentation.
2. Unless otherwise noted, fasteners and stress plates for insulation attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements:
➢ Wood Deck: OMG #14 Roofgrip with Flat Bottom Plate (Accutrac), OMG HD with OMG 3 in. Galvalume Steel Plate, Dekfast #14 with Hex Plate or 3” Round Insulation Plate, Trufast HD with Trufast 3”
Metal Insulation Plates or FlintFast #14 Fastener with FlintFast 3” Insulation Plates. Minimum 0.75-inch plywood penetration or minimum 1-inch wood plank embedment.
➢ Steel Deck: OMG #12 or #14 Roofgrip with Recessed or Flat Bottom Plate (Accutrac), OMG #12 Standard or HD with OMG 3 in. Galvalume Steel Plate, Dekfast #12 or #14 with Hex Plate or 3” Round
Insulation Plate, Trufast DP or HD with Trufast 3” Metal Insulation Plates or FlintFast #12 or #14 Fastener with FlintFast 3” Insulation Plates. Minimum 0.75-inch steel penetration and
engage the top flute of the steel deck.
➢ Structural Concrete: OMG #14 Roofgrip with Recessed or Flat Bottom Plate (Accutrac), OMG HD or CD-10 with OMG 3 in. Galvalume Steel Plate, Dekfast #14 or DekSpike with Hex Plate or 3” Round
Insulation Plate, Trufast HD or CF with Trufast 3” Metal Insulation Plates or FlintFast #14 Fastener with FlintFast 3” Insulation Plates. Minimum 1-inch embedment. Fasteners installed
with a pilot hole in accordance with the fastener manufacturer’s published installation instructions.
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 2 of 57
3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, GlasRoc Roof Board or gypsum-based roof board that meets the QA requirements
of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover.
4. Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete may be substituted for, or installed beneath rigid insulation board for System Type D (mechanically attached base sheet, bonded roof cover),
whereby the base sheet screws and plates are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck
listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper
codified and/or FBC Approval documentation.
5. Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (January 2016).
6. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer’s published instructions.
➢ Hot asphalt (HA): Full coverage at 25-30 lbs/square
➢ Ashland Pliodeck (A-PD): Continuous 0.75 inch wide ribbons, 12-inch o.c. Ribbons of subsequent layers shall be perpendicular to those in the layer below.
➢ Dow INSTA-STIK Quik Set Insulation Adhesive (D-IS): Continuous 0.75 to 1 inch wide ribbons, 12-inch o.c.
➢ Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c.
➢ Millennium PG-1 Pump Grade Adhesive (M-PG1): Continuous 0.5 to 0.75-inch wide ribbons, 12-inch o.c.
➢ OMG OlyBond 500 or OlyBond Green (OB500): Continuous 0.75-inch wide ribbons, 12-inch o.c. (PaceCart or SpotShot)
➢ ICP Adhesives CR-20: Continuous 2.5 to 3-inch wide ribbons, 12-inch o.c.
➢ Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon-applied adhesive, boards shall be staggered from layer-to-layer.
➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one -half the specified ribbons spacing.
7. Unless otherwise noted, all insulations are flat-stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum
Design Pressure (MDP) limitations. In no case shall these values be used to ‘increase’ the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then
the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table:
➢ Ashland Pliodeck (A-PD) @ 12-inch o.c. MDP -105.0 psf (Min. 1.0-inch)
➢ Ashland Pliodeck (A-PD) @ 6-inch o.c. MDP -277.5 psf (Min. 1.0-inch)
➢ Dow INSTA-STIK Quik Set Insulation Adhesive (D-IS): MDP -120.0 psf (Min. 1.0-inch)
➢ Millennium One Step Foamable Adhesive (M-OSFA): MDP -157.5 psf (Min. 1.0-inch)
➢ Millennium PG-1 Pump Grade Adhesive (M-PG1): MDP -157.5 psf (Min. 1.0-inch)
➢ OMG OlyBond 500 (OB500): MDP -45.0 psf (Min. 0.5-inch Multi-Max FA3)
➢ OMG OlyBond 500 (OB500): MDP -187.5 psf (Min. 0.5-inch ISO 95+ GL)
➢ OMG OlyBond 500 (OB500): MDP -315.0 psf (Min. 0.5-inch ENRGY 3)
➢ OMG OlyBond 500 (OB500): MDP -487.5 psf (Min. 0.5-inch ACFoam II)
➢ ICP Adhesives CR-20: MDP -117.5 psf (Min. 1.0-inch)
8. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft.
9. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC
Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss
Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for
Zone 2/3 enhancements.
10. For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no
rational analysis is permitted.
11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resis tance. A qualified design professional shall review the data for comparison to the
minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105.
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 3 of 57
12. For existing substrates in a bonded recover or re-roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing
roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with
ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124.
13. For Concrete Deck or Recover Applications using System Type D, the insulation is optional.
14. Lightweight Insulating Concrete (LWC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced, refer to current LWC
Product Approval for specific deck construction and limitations. For systems where specific LWC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top-coat thickness is 2-inches.
For LWC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1
15. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications.
CERTAINTEED FLINTLASTIC® MODIFIED BITUMEN COMPONENTS & APPLICATION METHODS
REFERENCE LAYER MATERIAL APPLICATION
BP-AA
(Base and Ply sheets, Asphalt-Applied)
Base Glasbase; All Weather/Empire Base; Flexiglas Base; Flintlastic Base 20 Hot asphalt at 20-40 lbs/square Ply One or more Flintglas Ply 4; Flintglas Premium Ply 6
BP-AA2
(Base, Spot-Asphalt-Applied)
Base Yosemite Venting Base Hot asphalt in 24-inch diameter spots in 30-
inch grid pattern
BP-AA3
(Base, Spot-Asphalt-Applied)
Base Yosemite Venting Base Hot asphalt in 9-inch diameter spots in grid
pattern noted herein.
BP-AA4
(Base, Strip-Asphalt-Applied)
Base Yosemite Venting Base Hot asphalt in 9-inch wide ribbons spaced
as noted herein.
BP-CA2 Base/Ply Glasbase; All Weather/Empire Base; Flexiglas Base; Flintlastic Base 20 Henry #903 Adhesive at 1.5 gal/square
BP-CA3 Base/Ply Glasbase; All Weather/Empire Base; Flexiglas Base; Flintlastic Base 20 Millennium Hurricane Force Membrane
Adhesive, beads spaced 6-inch o.c.
SBS-AA
(SBS, Asphalt-Applied)
Base Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base
Hot asphalt at 20-40 lbs/square
Ply One or more Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base
Cap Flintlastic Cap 30; Flintlastic Cap 30 CoolStar; Flintlastic FR Cap 30; Flintlastic FR Cap 30 CoolStar; Flintlastic FR Dual
Cap; Flintlastic FR-P; Flintlastic FR-P CoolStar; Flintlastic Premium FR-P; Flintlastic Premium FR-P CoolStar;
Flintlastic GMS; Flintlastic GMS CoolStar
SBS-CA1
(SBS, Cold-Applied)
Base Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base
FlintBond Brush or Karnak No. 81 Cold
Process Modified Bitumen Adhesive Brush
Grade at 1 gal/square
Note: Base ply cures overnight prior to application of the ply or cap ply.
Ply Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base
Cap Flintlastic FR Cap 30; Flintlastic FR Cap 30 CoolStar; Flintlastic FR Dual Cap; Flintlastic FR-P; Flintlastic FR-P CoolStar;
Flintlastic Premium FR-P; Flintlastic Premium FR-P CoolStar; Flintlastic GMS; Flintlastic GMS CoolStar
SBS-CA2
(SBS, Cold-Applied)
Base Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base
Henry #903 Adhesive at 1.5 gal/square.
Ply Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base
Cap Flintlastic Cap 30; Flintlastic Cap 30 CoolStar; Flintlastic FR Cap 30; Flintlastic FR Cap 30 CoolStar; Flintlastic FR Dual
Cap; Flintlastic FR-P; Flintlastic FR-P CoolStar; Flintlastic Premium FR-P; Flintlastic Premium FR-P CoolStar;
Flintlastic GMS; Flintlastic GMS CoolStar
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 4 of 57
CERTAINTEED FLINTLASTIC® MODIFIED BITUMEN COMPONENTS & APPLICATION METHODS (CONTINUED)
REFERENCE LAYER MATERIAL APPLICATION
SBS-CA3
(SBS, Cold-Applied)
Base Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base
Millennium Hurricane Force Membrane
Adhesive, beads spaced 6-inch o.c.
Ply Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base
Cap Flintlastic Cap 30; Flintlastic Cap 30 CoolStar; Flintlastic FR Cap 30; Flintlastic FR Cap 30 CoolStar; Flintlastic FR Dual
Cap; Flintlastic FR-P; Flintlastic FR-P CoolStar; Flintlastic Premium FR-P; Flintlastic Premium FR-P CoolStar;
Flintlastic GMS; Flintlastic GMS CoolStar
SBS-TA
(SBS, Torch-Applied)
Base Flintlastic Ultra Poly SMS Base; Flintlastic Base 20 T
Torch-Applied Ply One or more Flintlastic Ultra Poly SMS Base; Flintlastic Base 20 T
Cap Flintlastic FR Cap 30 T; Flintlastic FR Cap 30 T CoolStar; Flintlastic GTS; Flintlastic GTS CoolStar; Flintlastic GTS-FR;
Flintlastic GTS-FR CoolStar; FlintClad
APP-TA
(APP, Torch-Applied)
Base One or more Flintlastic APP Base T; Flintlastic STA; Flintlastic STA Plus
Torch-Applied Cap Flintlastic STA; Flintlastic STA Plus; Flintlastic GTA; Flintlastic GTA CoolStar; Flintlastic GTA-FR; Flintlastic GTA-FR
CoolStar
SBS-SA-H
(SBS, Self-Adhering, Hybrid Systems)
Base/Ply Black Diamond Base Sheet; Flintlastic Ultra Glass SA Self-Adhering
SBS-SA
(SBS, Self-Adhering)
Base Flintlastic SA PlyBase; Flintlastic SA Mid Ply
Self-Adhering Ply Flintlastic SA PlyBase; Flintlastic SA Mid Ply
Cap Flintlastic SA Cap; Flintlastic SA Cap CoolStar; Flintlastic SA Cap FR; Flintlastic SA Cap FR CoolStar
16. Vapor barrier options for use over structural concrete deck followed by adhered insulation carry the following MDP limitations. The lesser of the MDP listings below vs. those in Table 3A applies:
VAPOR BARRIER OPTIONS; STRUCTURAL CONCRETE DECK; ADHERED INSULATION PER TABLE 3A; (The lesser of the MDP listings below vs. those in Table 3A applies)
OPTION
# PRIMER VAPOR BARRIER INSULATION ADHESIVE MDP (PSF) TYPE ATTACH
VB-1. FlintPrime Flintlastic SA PlyBase Self-adhering OB500, 12-inch o.c. -82.5
VB-2. FlintPrime Flintlastic GTA Torch-applied M-OSFA or M-PG1, 12-inch o.c. -420.0
VB-3. FlintPrime Flintlastic Base 20 T, Flintlastic FR Cap 30 T or Flintlastic GTS Torch-applied M-OSFA or M-PG1, 12-inch o.c. -495.0
17. ”MDP” = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads.
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 5 of 57
TABLE 1A: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
Sys.
No.
Deck
(Note 1)
Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 14) MDP
(psf) Type Fasteners Attach Type Attach Type Attach Base Ply Cap
SELF-ADHERING SYSTEMS:
W-1
Min. 19/32-
inch
plywood at
max. 24-
inch spans
Glasbase, All
Weather Empire,
Flexiglas Base,
Flintlastic Base 20;
Poly SMS; Ultra Poly
SMS; Yosemite
32 ga., 1-5/8-
inch dia. tin
caps with 11 ga.
annular ring
shank nails
9-inch o.c. in 4-inch
lap and 12-inch o.c.
in two (2), equally
spaced, staggered
center rows
Min. 1.5-inch
ACFoam II,
FlintBoard ISO,
ENRGY-3, H-Shield
or Multi-Max FA3
HA
Min. 0.25-inch
Dens Deck
primed with
FlintPrime or
FlintPrime SA
HA SBS-SA (Optional)
SBS-SA SBS-SA -45.0*
W-2
Min. 19/32-
inch
plywood at
max. 24-
inch spans
Glasbase, All
Weather Empire,
Flexiglas Base, Poly
SMS or Ultra Poly
SMS
32 ga., 1-5/8-
inch dia. tin
caps with 11 ga.
annular ring
shank nails
8-inch o.c. in 3-inch
lap and 8-inch o.c.
in three (3), equally
spaced, staggered
center rows
Min. 1.5-inch
ACFoam II,
FlintBoard ISO,
ENRGY-3, H-Shield
or Multi-Max FA3
HA full
coverage or
OB500, M-
OSFA, A-PD,
D-IS or CR-20,
4-inch o.c.
Min. 0.25-inch
Dens Deck
primed with
FlintPrime or
FlintPrime SA
HA full
coverage or
OB500, M-
OSFA, A-PD, D-
IS or CR-20, 6-
inch o.c.
SBS-SA (Optional)
SBS-SA SBS-SA -52.5
W-3
Min. 19/32-
inch
plywood at
max. 24-
inch spans
Yosemite Venting
Base Sheet
32 ga., 1-5/8-
inch dia. tin
caps with 11 ga.
annular ring
shank nails
8-inch o.c. in 3-inch
lap and 8-inch o.c.
in three (3), equally
spaced, staggered
center rows
Min. 1.5-inch
ACFoam II,
FlintBoard ISO,
ENRGY-3, H-Shield
or Multi-Max FA3
HA
Min. 0.25-inch
Dens Deck
primed with
FlintPrime or
FlintPrime SA
HA SBS-SA (Optional)
SBS-SA SBS-SA -52.5
W-4
Min. 19/32-
inch
plywood at
max. 24-
inch spans
Glasbase, All
Weather Empire,
Flexiglas Base, Poly
SMS or Ultra Poly
SMS
32 ga., 1-5/8-
inch dia. tin
caps with 11 ga.
annular ring
shank nails
8-inch o.c. in 3-inch
lap and 8-inch o.c.
in three (3), equally
spaced, staggered
center rows
(Optional) Min.
1.5-inch ACFoam
II, FlintBoard ISO,
ENRGY-3, H-Shield
or Multi-Max FA3
HA full
coverage or
OB500, M-
OSFA, A-PD,
D-IS or CR-20,
4-inch o.c.
Min. 0.25-inch
SECUROCK
Gypsum-Fiber
Roof Board
primed with
FlintPrime or
FlintPrime SA
HA full
coverage or
OB500, M-
OSFA, A-PD, D-
IS or CR-20, 6-
inch o.c.
SBS-SA (Optional)
SBS-SA SBS-SA -60.0
W-5
Min. 19/32-
inch
plywood at
max. 24-
inch spans
Yosemite Venting
Base Sheet
32 ga., 1-5/8-
inch dia. tin
caps with 11 ga.
annular ring
shank nails
8-inch o.c. in 3-inch
lap and 8-inch o.c.
in three (3), equally
spaced, staggered
center rows
(Optional) Min.
1.5-inch ACFoam
II, FlintBoard ISO,
ENRGY-3, H-Shield
or Multi-Max FA3
HA
Min. 0.25-inch
SECUROCK
Gypsum-Fiber
Roof Board
primed with
FlintPrime or
FlintPrime SA
HA SBS-SA (Optional)
SBS-SA SBS-SA -60.0
HYBRID SYSTEMS:
W-6
Min. 19/32-
inch
plywood at
max. 24-
inch spans
Glasbase, All
Weather Empire,
Flexiglas Base,
Flintlastic Base 20;
Poly SMS; Ultra Poly
SMS; Yosemite
32 ga., 1-5/8-
inch dia. tin
caps with 11 ga.
annular ring
shank nails
9-inch o.c. in 4-inch
lap and 12-inch o.c.
in two (2), equally
spaced, staggered
center rows
Min. 1.5-inch
ACFoam II,
FlintBoard ISO,
ENRGY-3, H-Shield
or Multi-Max FA3
HA None N/A SBS-SA-H
(Optional)
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-45.0*
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 6 of 57
TABLE 1A: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
Sys.
No.
Deck
(Note 1)
Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 14) MDP
(psf) Type Fasteners Attach Type Attach Type Attach Base Ply Cap
W-7
Min. 19/32-
inch
plywood at
max. 24-
inch
Glasbase; Flintglas
Premium Ply 6;
Yosemite
32 ga., 1-5/8-
inch dia. tin
caps with 11 ga.
annular ring
shank nails
8-inch o.c. in 3-inch
lap and 8-inch o.c.
in three (3), equally
spaced, staggered
center rows
Min. 1.5-inch
ACFoam II,
FlintBoard ISO,
ENRGY-3, H-Shield
or Multi-Max FA3
HA None N/A SBS-SA-H
(Optional)
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-60.0
CONVENTIONAL SYSTEMS:
W-8
Min. 19/32-
inch
plywood at
max. 24-
inch spans
Glasbase, All
Weather Empire,
Flexiglas Base,
Flintlastic Base 20;
Poly SMS; Ultra Poly
SMS; Yosemite
32 ga., 1-5/8-
inch dia. tin
caps with 11 ga.
annular ring
shank nails
9-inch o.c. in 4-inch
lap and 12-inch o.c.
in two (2), equally
spaced, staggered
center rows
Min. 1.5-inch
ACFoam II,
FlintBoard ISO,
ENRGY-3, H-Shield
or Multi-Max FA3
HA
Min. 0.25-inch
Dens Deck
primed with
FlintPrime (ASTM
D41) primer
HA
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
(Optional)
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-45.0*
W-9
Min. 19/32-
inch
plywood at
max. 24-
inch spans
Glasbase, All
Weather Empire,
Flexiglas Base, Poly
SMS or Ultra Poly
SMS
32 ga., 1-5/8-
inch dia. tin
caps with 11 ga.
annular ring
shank nails
8-inch o.c. in 3-inch
lap and 8-inch o.c.
in three (3), equally
spaced, staggered
center rows
Min. 1.5-inch
ACFoam II,
FlintBoard ISO,
ENRGY-3, H-Shield
or Multi-Max FA3
HA full
coverage or
OB500, M-
OSFA, A-PD,
D-IS or CR-20,
4-inch o.c.
Min. 0.25-inch
Dens Deck
primed with
FlintPrime (ASTM
D41) primer
HA full
coverage or
OB500, M-
OSFA, A-PD, D-
IS or CR-20, 6-
inch o.c.
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
(Optional)
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-52.5
W-10
Min. 19/32-
inch
plywood at
max. 24-
inch spans
Yosemite Venting
Base Sheet
32 ga., 1-5/8-
inch dia. tin
caps with 11 ga.
annular ring
shank nails
8-inch o.c. in 3-inch
lap and 8-inch o.c.
in three (3), equally
spaced, staggered
center rows
Min. 1.5-inch
ACFoam II,
FlintBoard ISO,
ENRGY-3, H-Shield
or Multi-Max FA3
HA
Min. 0.25-inch
Dens Deck
primed with
FlintPrime (ASTM
D41) primer
HA
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
(Optional)
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-52.5
W-11
Min. 19/32-
inch
plywood at
max. 24-
inch spans
Glasbase, All
Weather Empire,
Flexiglas Base, Poly
SMS or Ultra Poly
SMS
32 ga., 1-5/8-
inch dia. tin
caps with 11 ga.
annular ring
shank nails
8-inch o.c. in 3-inch
lap and 8-inch o.c.
in three (3), equally
spaced, staggered
center rows
(Optional) Min.
1.5-inch ACFoam
II, FlintBoard ISO,
ENRGY-3, H-Shield
or Multi-Max FA3
HA full
coverage or
OB500, M-
OSFA, A-PD,
D-IS or CR-20,
4-inch o.c.
Min. 0.25-inch
SECUROCK
Gypsum-Fiber
Roof Board
HA full
coverage or
OB500, M-
OSFA, A-PD, D-
IS or CR-20, 6-
inch o.c.
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
(Optional)
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-60.0
W-12
Min. 19/32-
inch
plywood at
max. 24-
inch spans
Yosemite Venting
Base Sheet
32 ga., 1-5/8-
inch dia. tin
caps with 11 ga.
annular ring
shank nails
8-inch o.c. in 3-inch
lap and 8-inch o.c.
in three (3), equally
spaced, staggered
center rows
(Optional) Min.
1.5-inch ACFoam
II, FlintBoard ISO,
ENRGY-3, H-Shield
or Multi-Max FA3
HA
Min. 0.25-inch
SECUROCK
Gypsum-Fiber
Roof Board
HA
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
(Optional)
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-60.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 7 of 57
TABLE 1B: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP (psf) Type Fasteners Attach Type Attach Base Ply Cap
HYBRID SYSTEMS:
W-13
Min. 15/32-inch
exterior grade
plywood at max. 24-
inch spans
Min. 1.5-inch ACFoam
II, FlintBoard ISO, H-
Shield or FlintBoard
ISOH.
FlintFast #12 or
#14 with
FlintFast 3”
Insulation Plates
1 per 1.33
ft2
Min. 1.5-inch ACFoam II,
FlintBoard ISO, H-Shield or
FlintBoard ISOH.
HA, D-IS, M-
OSFA, M-PG1
or OB500
SBS-SA-H (Optional) APP-TA APP-TA -67.5
CONVENTIONAL SYSTEMS:
W-14
Min. 23/32-inch
exterior grade
plywood at max. 24-
inch spans
Min. 1.5-inch ACFoam
II, FlintBoard ISO,
ENRGY 3, H-Shield
Note 2 1 per 2 ft2
Min. 0.5-inch Structodek
High Density Fiberboard
Roof Insulation, min. 0.75-
inch FescoBoard
(homogeneous)
HA BP-AA or
SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -45.0*
W-15
Min. 23/32-inch
exterior grade
plywood at max. 24-
inch spans
Min. 1.5-inch ACFoam
II, FlintBoard ISO,
ENRGY 3, H-Shield
Note 2 1 per 2 ft2
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board,
Dens Deck or Dens Deck
Prime
HA
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -45.0*
W-16
Min. 15/32-inch
exterior grade
plywood at max. 24-
inch spans
Min. 1.5-inch ACFoam
II, FlintBoard ISO, H-
Shield or FlintBoard
ISOH.
FlintFast #12 or
#14 with
FlintFast 3”
Insulation Plates
1 per 1.33
ft2
Optional additional layer(s)
of base insulation followed
by Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof board
HA, D-IS, M-
OSFA, M-PG1
or OB500
APP-TA (Optional) APP-TA APP-TA -90.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 8 of 57
TABLE 1C: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP
(psf) Type Fasteners Attach Base Ply Cap
SELF-ADHERING SYSTEMS:
W-17
Min. 15/32-inch
plywood at max. 24-
inch spans
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
Flintfast 3 in. Insulation
Plates with FlintFast #12
or #14
1 per 3.2 ft2 SBS-SA (Optional) SBS-
SA SBS-SA -30.0*
W-18
Min. 19/32-inch
exterior grade plywood
at max. 24-inch spans
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch Dens Deck Note 2 1 per 1.33 ft2
Apply FlintPrime or
FlintPrime SA to
board & plates,
followed by SBS-SA
(Optional) SBS-
SA SBS-SA -45.0
W-19
Min. 19/32-inch
exterior grade plywood
at max. 24-inch spans
(Optional) One or more
layers, any combination,
loose laid
Min. 3/8-inch SECUROCK
Gypsum-Fiber Roof Board
Flintfast 3 in. Insulation
Plates with FlintFast #12
or #14
1 per 2.7 ft2 SBS-SA (Optional) SBS-
SA SBS-SA -45.0*
W-20
Min. 19/32-inch
plywood at max. 24-
inch spans
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch ACFoam II,
ENRGY 3, H-Shield, Multi-Max
FA3 or FlintBoard ISO
Flintfast 3 in. Insulation
Plates with FlintFast #12
or #14
1 per 2 ft2
Apply FlintPrime or
FlintPrime SA to
board & plates,
followed by SBS-SA
(Optional) SBS-
SA SBS-SA -45.0*
W-21
Min. 15/32-inch
plywood at max. 24-
inch spans
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch FlintBoard ISO
FlintFast #14 HD with
FlintFast 3” Insulation
Plates or Trufast HD
with Trufast 3” Metal
Insulation Plates
1 per 1.6 ft2
Apply FlintPrime to
board & plates,
followed by SBS-SA
(Optional) SBS-
SA SBS-SA -52.5
W-22
Min. 19/32-inch
plywood at max. 24-
inch spans
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch ACFoam II,
ENRGY 3, H-Shield, Multi-Max
FA3 or FlintBoard ISO
Note 2 1 per 1.45 ft2
Apply FlintPrime or
FlintPrime SA to
board & plates,
followed by SBS-SA
(Optional) SBS-
SA SBS-SA -60.0
HYBRID SYSTEMS:
W-23
Min. 15/32-inch
plywood at max. 24-
inch spans
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch Dens Deck;
Dens Deck Prime
Flintfast 3 in. Insulation
Plates with FlintFast #12
or #14
1 per 2 ft2 SBS-SA-H
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA, SBS-TA
or APP-TA -30.0*
W-24
Min. 15/32-inch
plywood at max. 24-
inch spans
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch FlintBoard ISO
FlintFast #14 HD with
FlintFast 3” Insulation
Plates or Trufast HD
with Trufast 3” Metal
Insulation Plates
1 per 1.6 ft2 SBS-SA-H (Optional) SBS-
TA or APP-TA
SBS-TA or APP-
TA -52.5
W-25
Min. 15/32-inch
plywood at max. 24-
inch spans
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch ACFoam II,
FlintBoard ISO, ENRGY 3 or
Multi-Max FA3
Note 2 1 per 1.33 ft2 SBS-SA-H (Optional) BP-AA
or SBS-AA SBS-AA -52.5
W-26
Min. 19/32-inch
plywood at max. 24-
inch spans
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch ACFoam II,
FlintBoard ISO, H-Shield,
FlintBoard ISOH
Note 2 1 per 1.45 ft2 SBS-SA-H
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA, SBS-TA
or APP-TA -60.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 9 of 57
TABLE 1C: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP
(psf) Type Fasteners Attach Base Ply Cap
W-27
Min. 15/32-inch
plywood at max. 24-
inch spans
(Optional) Min. 1.5-inch, One
or more layers, any
combination, loose laid
Min. 1.5-inch ACFoam II,
FlintBoard ISO, H-Shield,
FlintBoard ISOH
Flintfast 3 in. Insulation
Plates with FlintFast #12
or #14
1 per 1.33 ft2 SBS-SA-H
(Optional) SBS-
AA, SBS-TA or
APP-TA
SBS-AA, SBS-TA
or APP-TA -75.0
W-28
Min. 19/32-inch
exterior grade plywood
at max. 24-inch spans
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch ACFoam II,
FlintBoard ISO, ENRGY 3 or
Multi-Max FA3
Note 2 1 per 1.33 ft2 SBS-SA-H (Optional) SBS-
TA or APP-TA
SBS-TA or APP-
TA -82.5
CONVENTIONAL SYSTEMS:
W-29
Min. 23/32-inch
exterior grade plywood
at max. 24-inch spans
(Optional) One or more
layers, any combination,
loose laid
Min. 0.5-inch Structodek High
Density Fiberboard Roof
Insulation, min. 0.75-inch
FescoBoard (homogeneous)
Note 2 1 per 2 ft2 BP-AA or SBS-AA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA, SBS-TA
or APP-TA -45.0*
W-30
Min. 15/32-inch
plywood at max. 24-
inch spans
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board,
Dens Deck or Dens Deck
Prime
FlintFast #12 or #14 HD
with FlintFast 3”
Insulation Plates
1 per 2 ft2
BP-AA, SBS-AA,
SBS-TA or APP-
TA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA, SBS-TA
or APP-TA -45.0*
W-31
Min. 15/32-inch
plywood at max. 24-
inch spans
(Optional for Recover) Min.
1.5-inch, One or more layers,
any combination, loose laid
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
FlintFast #12 or #14 HD
with FlintFast 3”
Insulation Plates
1 per 1.45 ft2 APP-TA (Optional) APP-
TA APP-TA -60.0
W-32
Min. 19/32-inch
exterior grade plywood
at max. 24-inch spans
(Optional for Concrete or
Recover) Min. 2-inch ACFoam
II, FlintBoard, H-Shield or
ENRGY 3, loose laid.
Min. 0.5-inch SECUROCK
Gypsum-Fiber Roof Board
FlintFast #12 or #14 HD
with FlintFast 3”
Insulation Plates
1 per 1.78 ft2
BP-AA, SBS-AA,
SBS-TA or APP-
TA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA, SBS-TA
or APP-TA -60.0
W-33
Min. 15/32-inch
plywood at max. 24-
inch spans
(Optional for Recover) Min.
1.5-inch, One or more layers,
any combination, loose laid
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
FlintFast #12 or #14 HD
with FlintFast 3”
Insulation Plates
1 per 1.33 ft2 APP-TA (Optional) APP-
TA APP-TA -67.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 10 of 57
TABLE 1D: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE D: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Insulation Layer(s) Base or Anchor Sheet Roof Cover (Note 14) MDP
(psf) Type Attach Base Fasteners Attach Ply Cap
SELF-ADHERING SYSTEMS:
W-34
Min. 19/32-inch
plywood at max 24-
inch spans
Min. 1.5-inch, One
or more layers,
any combination
Prelim.
Attach Flintlastic SA NailBase Note 2
8-inch o.c. at min. 3-inch lap and 8-
inch o.c. in two (2), equally spaced,
staggered center rows; Stress plates
shall be primed with FlintPrime
(ASTM D41) primer or FlintPrime SA
(Optional)
SBS-SA SBS-SA -82.5*
W-35
Min. 15/32-inch
plywood at max 24-
inch spans
Min. 1.5-inch, One
or more layers,
any combination
Prelim.
Attach Flintlastic SA NailBase
Flintfast 3 in. Insulation Plates
with FlintFast #12 or #14;
Trufast 3” Metal Insulation
Plates with DP or HD; OMG 3
in. Round Metal Plates with
OMG #14 HD
6-inch o.c. at min. 2-inch lap and 6-
inch o.c. in three (3), equally spaced,
staggered center rows; Stress plates
shall be primed with FlintPrime
(ASTM D41) primer or FlintPrime SA.
(Optional)
SBS-SA SBS-SA -97.5*
W-36
Min. 15/32-inch
plywood at max 24-
inch spans
Min. 1.5-inch, One
or more layers,
any combination
Prelim.
Attach Flintlastic SA NailBase
Flintfast 3 in. Insulation Plates
with FlintFast #12 or #14;
Trufast 3” Metal Insulation
Plates with DP or HD; OMG 3
in. Round Metal Plates with
OMG #14 HD
6-inch o.c. at min. 2-inch lap and 6-
inch o.c. in four (4), equally spaced,
staggered center rows; Stress plates
shall be primed with FlintPrime
(ASTM D41) primer or FlintPrime SA.
(Optional)
SBS-SA SBS-SA -127.5*
HYBRID SYSTEMS:
W-37
Min. 15/32-inch
plywood at max 24-
inch spans
Min. 1.5-inch, One
or more layers,
any combination
Prelim.
Attach
Glasbase; Flexiglas;
Flintlastic Base 20; Poly SMS
Base; Ultra Poly SMS Base
Flintfast 3 in. Insulation Plates
with FlintFast #12 or #14;
Trufast 3” Metal Insulation
Plates with DP or HD; OMG 3
in. Round Metal Plates with
OMG #14 HD
6-inch o.c. at 4-inch lap and 6-inch
o.c. in three (3), equally spaced,
staggered center rows; Stress plates
shall be primed with FlintPrime
(ASTM D41) primer or FlintPrime SA.
SBS-SA-H SBS-AA, SBS-
TA or APP-TA -97.5
W-38
Min. 19/32-inch
plywood at max 24-
inch spans
Min. 1.5-inch, One
or more layers,
any combination
Prelim.
Attach
Glasbase; Flexiglas;
Flintlastic Base 20; Poly SMS
Base; Ultra Poly SMS Base
Note 2
7-inch o.c. at 3-inch lap and 7-inch
o.c. in three (3), equally spaced,
staggered center rows
SBS-SA-H SBS-AA, SBS-
TA or APP-TA -105.0
W-39
Min. 15/32-inch
plywood at max 24-
inch spans
Min. 1.5-inch, One
or more layers,
any combination
Prelim.
Attach
Glasbase; Flexiglas;
Flintlastic Base 20; Poly SMS
Base; Ultra Poly SMS Base
Flintfast 3 in. Insulation Plates
with FlintFast #12 or #14;
Trufast 3” Metal Insulation
Plates with DP or HD; OMG 3
in. Round Metal Plates with
OMG #14 HD
6-inch o.c. at 4-inch lap and 6-inch
o.c. in four (4), equally spaced,
staggered center rows; Stress plates
shall be primed with FlintPrime
(ASTM D41) primer or FlintPrime SA.
SBS-SA-H SBS-AA, SBS-
TA or APP-TA -127.5
CONVENTIONAL SYSTEMS:
W-40
Min. 23/32-inch
exterior grade
plywood at max. 24-
inch spans
Min. 1.5-inch, One
or more layers,
any combination
Prelim.
Attach
Glasbase; All
Weather/Empire Base;
Flexiglas Base; Flintlastic
Base 20; Yosemite
Note 2
12-inch o.c. at 4-inch lap and 36-inch
o.c. in two (2), equally spaced,
staggered center rows
BP-AA, SBS-
AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -30.0*
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 11 of 57
TABLE 1D: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE D: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Insulation Layer(s) Base or Anchor Sheet Roof Cover (Note 14) MDP
(psf) Type Attach Base Fasteners Attach Ply Cap
W-41
Min. 23/32-inch
exterior grade
plywood at max. 24-
inch spans
Min. 1.5-inch, One
or more layers,
any combination
Prelim.
Attach
Glasbase; All
Weather/Empire Base;
Flexiglas Base; Flintlastic
Base 20; Yosemite
Note 2
12-inch o.c. at 4-inch lap and 24-inch
o.c. in two (2), equally spaced,
staggered center rows
BP-AA, SBS-
AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -45.0*
W-42
Min. 23/32-inch
exterior grade
plywood at max. 24-
inch spans
Min. 1.5-inch, One
or more layers,
any combination
Prelim.
Attach
Poly SMS Base; Ultra Poly
SMS Base Note 2
12-inch o.c. at 4-inch lap and 36-inch
o.c. in two (2), equally spaced,
staggered center rows
BP-AA, SBS-
AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -45.0*
W-43
Min. 15/32-inch
plywood at max 24-
inch spans
Min. 1.5-inch, One
or more layers,
any combination
Prelim.
Attach
Glasbase; Flexiglas;
Flintlastic Base 20; All
Weather / Empire Base;
Poly SMS Base; Ultra Poly
SMS Base; Yosemite
Flintfast 3 in. Insulation Plates
with FlintFast #12 or #14;
Trufast 3” Metal Insulation
Plates with DP or HD; OMG 3
in. Round Metal Plates with
OMG #14 HD
6-inch o.c. at 4-inch lap and 6-inch
o.c. in three (3), equally spaced,
staggered center rows.
(Optional) BP-
AA, SBS-AA,
SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -97.5
W-44
Min. 15/32-inch
plywood at max 24-
inch spans
Min. 1.5-inch, One
or more layers,
any combination
Prelim.
Attach Flintlastic APP Base T OMG 3 in. Round Metal Plates
with OMG #14 HD
6-inch o.c. at 4-inch lap and 6-inch
o.c. in three (3), equally spaced,
staggered center rows.
APP-TA APP-TA -97.5
W-45
Min. 15/32-inch
plywood at max 24-
inch spans
One or more
layers, any
thickness or
combination
Prelim.
Attach
Glasbase; Flexiglas;
Flintlastic Base 20; All
Weather / Empire Base;
Poly SMS Base; Ultra Poly
SMS Base; Yosemite
Flintfast 3 in. Insulation Plates
with FlintFast #14; Trufast 3"
Metal Insulation Plates with
Trufast HD
8-inch o.c. at 4-inch lap and 8-inch
o.c. at three (3) equally spaced,
staggered center rows
(Optional) BP-
AA, SBS-AA,
SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP_TA -97.5
W-46
Min. 19/32-inch
plywood at max 24-
inch spans
Min. 1.5-inch, One
or more layers,
any combination
Prelim.
Attach
Glasbase; Flexiglas;
Flintlastic Base 20; Poly SMS
Base; Ultra Poly SMS Base;
Yosemite
Note 2
7-inch o.c. at 3-inch lap and 7-inch
o.c. in three (3), equally spaced,
staggered center rows
BP-AA, SBS-
AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -105.0
W-47
Min. 19/32-inch
plywood at max 24-
inch spans
Min. 1.5-inch, One
or more layers,
any combination
Prelim.
Attach Flintlastic APP Base T
OMG 3 in. Round Metal Plates
with OMG #14 HD or Dekfast
Hex Plate with Dekfast #14
7-inch o.c. at 3-inch lap and 7-inch
o.c. in three (3), equally spaced,
staggered center rows
APP-TA APP-TA -105.0
W-48
Min. 15/32-inch
plywood at max 24-
inch spans
Min. 1.5-inch, One
or more layers,
any combination
Prelim.
Attach
Glasbase; Flexiglas;
Flintlastic Base 20; Poly SMS
Base; Ultra Poly SMS Base;
Yosemite
Flintfast 3 in. Insulation Plates
with FlintFast #12 or #14;
Trufast 3” Metal Insulation
Plates with DP or HD; OMG 3
in. Round Metal Plates with
OMG #14 HD
6-inch o.c. at 4-inch lap and 6-inch
o.c. in four (4), equally spaced,
staggered center rows.
(Optional) BP-
AA, SBS-AA,
SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -127.5
W-49
Min. 15/32-inch
plywood at max 24-
inch spans
Min. 1.5-inch, One
or more layers,
any combination
Prelim.
Attach Flintlastic APP Base T OMG 3 in. Round Metal Plates
with OMG #14 HD
6-inch o.c. at 4-inch lap and 6-inch
o.c. in four (4), equally spaced,
staggered center rows.
APP-TA APP-TA -127.5
COLD-APPLIED SYSTEMS:
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 12 of 57
TABLE 1D: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE D: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Insulation Layer(s) Base or Anchor Sheet Roof Cover (Note 14) MDP
(psf) Type Attach Base Fasteners Attach Ply Cap
W-50
Min. 15/32-inch
plywood at max 24-
inch spans
Min. 1-inch, One
or more layers,
any combination
Loose-
laid
Glasbase; Flexiglas Base;
Flintlastic Base 20; All
Weather / Empire Base;
Yosemite Venting Base;
Flintlastic Poly SMS Base;
Flintlastic Ultra Poly SMS
Base
Flintfast 3 in. Insulation Plates
with FlintFast #12 or #14;
Trufast 3” Metal Insulation
Plates with DP or HD
8-inch o.c. at 4-inch lap and 8-inch
o.c. in three (3), equally spaced,
staggered center rows
(Optional)
SBS-CA1 SBS-CA1 -52.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 13 of 57
TABLE 1E-1: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Sheet Roof Cover (Note 14) MDP
(psf) Base Fasteners Attach Ply Cap
SELF-ADHERING SYSTEMS:
W-51 Min. 15/32-inch plywood at
max 24-inch spans Flintlastic SA NailBase Simplex MAXX Cap
9-inch o.c. at min. 3-inch lap and 12-inch o.c. in
two (2), equally spaced, staggered center rows;
Stress plates shall be primed with FlintPrime
(ASTM D41) primer.
(Optional) SBS-
SA SBS-SA -45.0*
W-52 Min. 15/32-inch plywood at
max 24-inch spans Flintlastic SA NailBase Min. 1-inch long, 12 ga. Simplex
Metal Cap Nails
6-inch o.c. at min. 2-inch lap and 6-inch o.c. in
four (4), equally spaced, staggered center rows
(Optional) SBS-
SA SBS-SA -52.5
W-53 Min. 19/32-inch plywood at
max. 24-inch spans Flintlastic SA NailBase
32 ga., 1-5/8-inch dia. tin caps
with 11 ga. annular ring shank
nails
8-inch o.c. at min. 2-inch lap and 8-inch o.c. in
three (3), equally spaced, staggered center
rows
(Optional) SBS-
SA SBS-SA -52.5
W-54 Min. 19/32-inch plywood at
max. 24-inch spans Flintlastic SA NailBase
32 ga., 1-5/8-inch dia. tin caps
with 11 ga. annular ring shank
nails
8-inch o.c. at min. 2-inch lap and 8-inch o.c. in
three (3), equally spaced, staggered center
rows
(Optional) SBS-
SA SBS-SA -60.0
W-55 Min. 15/32-inch plywood at
max 24-inch spans Flintlastic SA NailBase Simplex MAXX Cap
8-inch o.c. at min. 3-inch lap and 8-inch o.c. in
three (3), equally spaced, staggered center
rows; Stress plates shall be primed with
FlintPrime (ASTM D41) primer.
(Optional) SBS-
SA SBS-SA -67.5
W-56 Min. 19/32-inch plywood at
max 24-inch spans Flintlastic SA NailBase
32 ga., 1-5/8-inch dia. tin caps
with 11 ga. annular ring shank
nails
6-inch o.c. at min. 2-inch lap and 6-inch o.c. in
four (4), equally spaced, staggered center rows
(Optional) SBS-
SA SBS-SA -75.0
W-57 Min. 15/32-inch plywood at
max 24-inch spans Flintlastic SA NailBase
Cap nails: 1-inch diameter,
0.032-inch thick metal cap with
0.120" shank diameter, annular
ring shank nails
7-inch o.c. at min. 4-inch laps and 7-inch o.c. in
five (5), equally spaced, staggered center rows
(Optional) SBS-
SA SBS-SA -75.0
W-58 Min. 19/32-inch plywood at
max 24-inch spans Flintlastic SA NailBase
32 ga., 1-5/8-inch dia. tin caps
with 11 ga. annular ring shank
nails
4-inch o.c. at min. 2-inch lap and 4-inch o.c. in
four (4), equally spaced, staggered center rows
(Optional) SBS-
SA SBS-SA -105.0
HYBRID SYSTEMS:
W-59 Min. 19/32-inch exterior grade
plywood at max. 24-inch spans
Glasbase; Flexiglas; Flintlastic
Base 20; All Weather / Empire
Base; Poly SMS Base; Ultra Poly
SMS Base
32 ga., 1-5/8-inch dia. tin caps
with 11 ga. annular ring shank
nails
9-inch o.c. at 4-inch lap and 12-inch o.c. in two
(2), equally spaced, staggered center rows SBS-SA-H SBS-AA, SBS-TA
or APP-TA -45.0*
W-60 Min. 15/32-inch plywood at
max 24-inch spans
Glasbase; Flexiglas; Flintlastic
Base 20; All Weather / Empire
Base; Poly SMS Base; Ultra Poly
SMS Base
Min. 1-inch long, 12 ga. Simplex
Metal Cap Nails
6-inch o.c. at 3-inch lap and 6-inch o.c. in four
(4), equally spaced, staggered center rows SBS-SA-H SBS-AA, SBS-TA
or APP-TA -52.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 14 of 57
TABLE 1E-1: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Sheet Roof Cover (Note 14) MDP
(psf) Base Fasteners Attach Ply Cap
W-61 Min. 19/32-inch plywood at
max 24-inch spans
Glasbase; Flexiglas; Flintlastic
Base 20; Poly SMS Base; Ultra
Poly SMS Base
32 ga., 1-5/8-inch dia. tin caps
with 11 ga. annular ring shank
nails
8-inch o.c. at 4-inch lap and 8-inch o.c. in three
(3), equally spaced, staggered center rows SBS-SA-H SBS-AA, SBS-TA
or APP-TA -52.5
W-62 Min. 19/32-inch plywood at
max 24-inch spans
Glasbase; Flexiglas; Flintlastic
Base 20; Poly SMS Base; Ultra
Poly SMS Base
32 ga., 1-5/8-inch dia. tin caps
with 11 ga. annular ring shank
nails
8-inch o.c. at 4-inch lap and 8-inch o.c. in three
(3), equally spaced, staggered center rows SBS-SA-H SBS-AA, SBS-TA
or APP-TA -60.0
W-63 Min. 19/32-inch plywood at
max 24-inch spans
Glasbase; Flexiglas; Flintlastic
Base 20; Poly SMS Base; Ultra
Poly SMS Base
32 ga., 1-5/8-inch dia. tin caps
with 11 ga. annular ring shank
nails
6-inch o.c. at 4-inch lap and 6-inch o.c. in four
(4), equally spaced, staggered center rows SBS-SA-H SBS-AA, SBS-TA
or APP-TA -82.5
W-64 Min. 19/32-inch plywood at
max 24-inch spans
Glasbase; Flexiglas; Flintlastic
Base 20; Poly SMS Base; Ultra
Poly SMS Base
32 ga., 1-5/8-inch dia. tin caps
with 11 ga. annular ring shank
nails
4-inch o.c. at 3-inch lap and 4-inch o.c. in four
(4), equally spaced, staggered center rows SBS-SA-H SBS-AA, SBS-TA
or APP-TA -105.0
CONVENTIONAL SYSTEMS:
W-65 Min. 19/32-inch exterior grade
plywood at max. 24-inch spans
Glasbase; Flexiglas; Flintlastic
Base 20; All Weather / Empire
Base; Poly SMS Base; Ultra Poly
SMS Base; Yosemite
32 ga., 1-5/8-inch dia. tin caps
with 11 ga. annular ring shank
nails
9-inch o.c. at 4-inch lap and 12-inch o.c. in two
(2), equally spaced, staggered center rows
BP-AA, SBS-AA,
SBS-TA or APP-
TA
SBS-AA, SBS-TA
or APP-TA -45.0*
W-66 Min. 15/32-inch exterior grade
plywood at max. 24-inch spans
Glasbase; Flexiglas; Flintlastic
Base 20; All Weather / Empire
Base; Poly SMS Base; Yosemite
Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 18-inch o.c. in two
(2), equally spaced, staggered center rows
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA, SBS-TA
or APP-TA -45.0*
W-67 Min. 15/32-inch exterior grade
plywood at max. 24-inch spans Flintlastic APP Base T Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 18-inch o.c. in two
(2), equally spaced, staggered center rows
(Optional) APP-
TA APP-TA -45.0*
W-68 Min. 15/32-inch plywood at
max 24-inch spans
Glasbase; Flexiglas; Flintlastic
Base 20; All Weather / Empire
Base; Poly SMS Base; Ultra Poly
SMS Base; Yosemite
Min. 1-inch long, 12 ga. Simplex
Metal Cap Nails
6-inch o.c. at 3-inch lap and 6-inch o.c. in four
(4), equally spaced, staggered center rows
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA, SBS-TA
or APP-TA -52.5
W-69 Min. 19/32-inch plywood at
max 24-inch spans
Glasbase; Flexiglas; Flintlastic
Base 20; Poly SMS Base; Ultra
Poly SMS Base; Yosemite
32 ga., 1-5/8-inch dia. tin caps
with 11 ga. annular ring shank
nails
8-inch o.c. at 4-inch lap and 8-inch o.c. in three
(3), equally spaced, staggered center rows
BP-AA, SBS-AA,
SBS-TA or APP-
TA
SBS-AA, SBS-TA
or APP-TA -52.5
W-70 Min. 15/32-inch exterior grade
plywood at max. 24-inch spans
Glasbase; Flexiglas; Flintlastic
Base 20; All Weather / Empire
Base; Poly SMS Base; Yosemite
Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 12-inch o.c. in two
(2), equally spaced, staggered center rows
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA, SBS-TA
or APP-TA -52.5
W-71 Min. 15/32-inch exterior grade
plywood at max. 24-inch spans Flintlastic APP Base T Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 12-inch o.c. in two
(2), equally spaced, staggered center rows
(Optional) APP-
TA APP-TA -52.5
W-72 Min. 19/32-inch plywood at
max 24-inch spans
Glasbase; Flexiglas; Flintlastic
Base 20; Poly SMS Base; Ultra
Poly SMS Base; Yosemite
32 ga., 1-5/8-inch dia. tin caps
with 11 ga. annular ring shank
nails
8-inch o.c. at 4-inch lap and 8-inch o.c. in three
(3), equally spaced, staggered center rows
BP-AA, SBS-AA,
SBS-TA or APP-
TA
SBS-AA, SBS-TA
or APP-TA -60.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 15 of 57
TABLE 1E-1: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Sheet Roof Cover (Note 14) MDP
(psf) Base Fasteners Attach Ply Cap
W-73 Min. 15/32-inch plywood at
max 24-inch spans
Glasbase; Flexiglas; Flintlastic
Base 20; All Weather / Empire
Base; Poly SMS Base; Ultra Poly
SMS Base; Yosemite
Cap nails: 1-inch diameter,
0.032-inch thick metal cap with
0.120-inch shank diameter,
annular ring shank nails.
6-inch o.c. at 4-inch lap and 6-inch o.c. at five
(5) equally spaced, staggered center rows
(Optional) BP-
AA, SBS-AA or
SBS-TA
SBS-AA or SBS-
TA -67.5
W-74 Min. 19/32-inch plywood at
max 24-inch spans
Glasbase; Flexiglas; Flintlastic
Base 20; Poly SMS Base; Ultra
Poly SMS Base; Yosemite
32 ga., 1-5/8-inch dia. tin caps
with 11 ga. annular ring shank
nails
6-inch o.c. at 4-inch lap and 6-inch o.c. in four
(4), equally spaced, staggered center rows
BP-AA, SBS-AA,
SBS-TA or APP-
TA
SBS-AA, SBS-TA
or APP-TA -82.5
W-75 Min. 15/32-inch exterior grade
plywood at max. 24-inch spans
Glasbase; Flexiglas; Flintlastic
Base 20; All Weather / Empire
Base; Poly SMS Base; Yosemite
Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in two
(2), equally spaced, staggered center rows
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA, SBS-TA
or APP-TA -90.0
W-76 Min. 15/32-inch exterior grade
plywood at max. 24-inch spans Flintlastic APP Base T Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in two
(2), equally spaced, staggered center rows
(Optional) APP-
TA APP-TA -90.0
W-77 Min. 19/32-inch plywood at
max 24-inch spans
Glasbase; Flexiglas; Flintlastic
Base 20; Poly SMS Base; Ultra
Poly SMS Base; Yosemite
32 ga., 1-5/8-inch dia. tin caps
with 11 ga. annular ring shank
nails
4-inch o.c. at 3-inch lap and 4-inch o.c. in four
(4), equally spaced, staggered center rows
BP-AA, SBS-AA,
SBS-TA or APP-
TA
SBS-AA, SBS-TA
or APP-TA -105.0
W-78 Min. 15/32-inch exterior grade
plywood at max. 24-inch spans
Glasbase; Flexiglas; Flintlastic
Base 20; All Weather / Empire
Base; Poly SMS Base; Yosemite
Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in three
(3), equally spaced, staggered center rows
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA, SBS-TA
or APP-TA -105.0
W-79 Min. 15/32-inch exterior grade
plywood at max. 24-inch spans Flintlastic APP Base T Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in three
(3), equally spaced, staggered center rows
(Optional) APP-
TA APP-TA -105.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 16 of 57
TABLE 1E-2: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Sheet Roof Cover (Note 14) MDP
(psf) Base Fasteners Attach Ply Cap
SELF-ADHERING SYSTEMS:
W-80 Min. 19/32-inch plywood
at max 24-inch spans Flintlastic SA NailBase Note 2
8-inch o.c. at min. 3-inch lap and 8-inch o.c. in
two (2), equally spaced, staggered center rows.
Stress plates shall be primed with FlintPrime
(ASTM D41) primer or FlintPrime SA
(Optional)
SBS-SA SBS-SA -82.5*
W-81 Min. 15/32-inch plywood
at max 24-inch spans Flintlastic SA NailBase
Flintfast 3 in. Insulation Plates with
FlintFast #12 or #14; Trufast 3” Metal
Insulation Plates with DP or HD; OMG 3
in. Round Metal Plates with OMG #14 HD
6-inch o.c. at min. 2-inch lap and 6-inch o.c. in
three (3), equally spaced, staggered center rows.
Stress plates shall be primed with FlintPrime
(ASTM D41) primer or FlintPrime SA.
(Optional)
SBS-SA SBS-SA -97.5*
W-82 Min. 15/32-inch plywood
at max 24-inch spans Flintlastic SA NailBase
Flintfast 3 in. Insulation Plates with
FlintFast #12 or #14; Trufast 3” Metal
Insulation Plates with DP or HD; OMG 3
in. Round Metal Plates with OMG #14 HD
6-inch o.c. at min. 2-inch lap and 6-inch o.c. in
four (4), equally spaced, staggered center rows.
Stress plates shall be primed with FlintPrime
(ASTM D41) primer or FlintPrime SA.
(Optional)
SBS-SA SBS-SA -127.5*
HYBRID SYSTEMS:
W-83 Min. 15/32-inch plywood
at max 24-inch spans
Glasbase; Flexiglas; Flintlastic
Base 20; Poly SMS Base; Ultra
Poly SMS Base
Flintfast 3 in. Insulation Plates with
FlintFast #12 or #14; Trufast 3” Metal
Insulation Plates with DP or HD; OMG 3
in. Round Metal Plates with OMG #14 HD
6-inch o.c. at 4-inch lap and 6-inch o.c. in three
(3), equally spaced, staggered center rows.
Stress plates shall be primed with FlintPrime
(ASTM D41) primer or FlintPrime SA.
SBS-SA-H SBS-AA, SBS-
TA or APP-TA -97.5
W-84 Min. 19/32-inch plywood
at max 24-inch spans
Glasbase; Flexiglas; Flintlastic
Base 20; Poly SMS Base; Ultra
Poly SMS Base
Note 2 7-inch o.c. at 3-inch lap and 7-inch o.c. in three
(3), equally spaced, staggered center rows SBS-SA-H SBS-AA, SBS-
TA or APP-TA -105.0
W-85 Min. 15/32-inch plywood
at max 24-inch spans
Glasbase; Flexiglas; Flintlastic
Base 20; Poly SMS Base; Ultra
Poly SMS Base
Flintfast 3 in. Insulation Plates with
FlintFast #12 or #14; Trufast 3” Metal
Insulation Plates with DP or HD; OMG 3
in. Round Metal Plates with OMG #14 HD
6-inch o.c. at 4-inch lap and 6-inch o.c. in four
(4), equally spaced, staggered center rows.
Stress plates shall be primed with FlintPrime
(ASTM D41) primer or FlintPrime SA.
SBS-SA-H SBS-AA, SBS-
TA or APP-TA -127.5
CONVENTIONAL SYSTEMS:
W-86
Min. 23/32-inch exterior
grade plywood at max.
24-inch spans
Glasbase; All Weather/Empire
Base; Flexiglas Base; Flintlastic
Base 20; Yosemite
Note 2 12-inch o.c. at 4-inch lap and 36-inch o.c. in two
(2), equally spaced, staggered center rows
BP-AA, SBS-
AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -30.0*
W-87
Min. 23/32-inch exterior
grade plywood at max.
24-inch spans
Glasbase; All Weather/Empire
Base; Flexiglas Base; Flintlastic
Base 20; Yosemite
Note 2 12-inch o.c. at 4-inch lap and 24-inch o.c. in two
(2), equally spaced, staggered center rows
BP-AA, SBS-
AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -45.0*
W-88
Min. 23/32-inch exterior
grade plywood at max.
24-inch spans
Poly SMS Base; Ultra Poly SMS
Base Note 2 12-inch o.c. at 4-inch lap and 36-inch o.c. in two
(2), equally spaced, staggered center rows
BP-AA, SBS-
AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -45.0*
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 17 of 57
TABLE 1E-2: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Sheet Roof Cover (Note 14) MDP
(psf) Base Fasteners Attach Ply Cap
W-89 Min. 15/32-inch plywood
at max 24-inch spans
Glasbase; Flexiglas; Flintlastic
Base 20; Poly SMS Base; Ultra
Poly SMS Base; Yosemite
Flintfast 3 in. Insulation Plates with
FlintFast #12 or #14; Trufast 3” Metal
Insulation Plates with DP or HD; OMG 3
in. Round Metal Plates with OMG #14 HD
6-inch o.c. at 4-inch lap and 6-inch o.c. in three
(3), equally spaced, staggered center rows
(Optional) BP-
AA, SBS-AA,
SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -97.5
W-90 Min. 15/32-inch plywood
at max 24-inch spans Flintlastic APP Base T OMG 3 in. Round Metal Plates with OMG
#14 HD
6-inch o.c. at 4-inch lap and 6-inch o.c. in three
(3), equally spaced, staggered center rows. APP-TA APP-TA -97.5
W-91 Min. 15/32-inch plywood
at max 24-inch spans
Glasbase; Flexiglas; Flintlastic
Base 20; All Weather / Empire
Base; Poly SMS Base; Ultra Poly
SMS Base; Yosemite
Flintfast 3 in. Insulation Plates with
FlintFast #14; Trufast 3" Metal Insulation
Plates with Trufast HD
8-inch o.c. at 4-inch lap and 8-inch o.c. at three
(3) equally spaced, staggered center rows
(Optional) BP-
AA, SBS-AA or
SBS-TA
SBS-AA or
SBS-TA -97.5
W-92 Min. 19/32-inch plywood
at max 24-inch spans
Glasbase; Flexiglas; Flintlastic
Base 20; Poly SMS Base; Ultra
Poly SMS Base; Yosemite
Note 2 7-inch o.c. at 3-inch lap and 7-inch o.c. in three
(3), equally spaced, staggered center rows
BP-AA, SBS-
AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -105.0
W-93 Min. 19/32-inch plywood
at max 24-inch spans Flintlastic APP Base T
OMG 3 in. Round Metal Plates with OMG
#14 HD or Dekfast Hex Plate with Dekfast
#14
7-inch o.c. at 3-inch lap and 7-inch o.c. in three
(3), equally spaced, staggered center rows APP-TA APP-TA -105.0
W-94 Min. 15/32-inch plywood
at max 24-inch spans
Glasbase; Flexiglas; Flintlastic
Base 20; Poly SMS Base; Ultra
Poly SMS Base; Yosemite
Flintfast 3 in. Insulation Plates with
FlintFast #12 or #14; Trufast 3” Metal
Insulation Plates with DP or HD; OMG 3
in. Round Metal Plates with OMG #14 HD
6-inch o.c. at 4-inch lap and 6-inch o.c. in four
(4), equally spaced, staggered center rows
(Optional) BP-
AA, SBS-AA,
SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -127.5
W-95 Min. 15/32-inch plywood
at max 24-inch spans Flintlastic APP Base T OMG 3 in. Round Metal Plates with OMG
#14 HD
6-inch o.c. at 4-inch lap and 6-inch o.c. in four
(4), equally spaced, staggered center rows. APP-TA APP-TA -127.5
COLD-APPLIED SYSTEMS:
W-96 Min. 15/32-inch plywood
at max 24-inch spans
Glasbase; Flexiglas Base;
Flintlastic Base 20; All Weather /
Empire Base; Yosemite Venting
Base; Flintlastic Poly SMS Base;
Flintlastic Ultra Poly SMS Base
Flintfast 3 in. Insulation Plates with
FlintFast #12 or #14; Trufast 3” Metal
Insulation Plates with DP or HD
8-inch o.c. at 4-inch lap and 8-inch o.c. in three
(3), equally spaced, staggered center rows
(Optional)
SBS-CA1 SBS-CA1 -52.5
TABLE 1F: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER
System
No.
Deck
(Note 1) Primer Roof Cover (Note 14) MDP (psf) Base Ply Cap
W-97 Min. 15/32-inch plywood at max 24-inch spans FlintPrime or FlintPrime SA SBS-SA-H (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -112.5
W-98 Min. 15/32-inch plywood at max 24-inch spans FlintPrime or FlintPrime SA SBS-SA (Optional) SBS-SA SBS-SA -127.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 18 of 57
TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP
(psf) Type Fasteners Attach Type Attach Base Ply Cap
SELF-ADHERING SYSTEMS:
S-1
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 2-inch ACFoam II,
FlintBoard, ENRGY 3 or
H-Shield
Note 2 1 per 4
ft2
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
HA, D-IS, M-
OSFA, OB500
or CR-20
SBS-SA (Optional) SBS-SA SBS-SA -37.5*
S-2
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch ACFoam
II, FlintBoard, ENRGY 3
or H-Shield
Note 2 1 per 2
ft2
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
HA, D-IS, M-
OSFA, OB500
or CR-20
SBS-SA (Optional) SBS-SA SBS-SA -45.0*
HYBRID SYSTEMS:
S-3
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch ACFoam
II, FlintBoard, ENRGY 3
or H-Shield
Note 2 1 per
1.45 ft2
Additional layer(s) base
insulation
HA, D-IS, M-
OSFA, OB500
or CR-20
Flintlastic
Ultra
Glass SA
(Optional) SBS-AA,
SBS-TA, APP-TA
SBS-AA,
SBS-TA,
APP-TA
-37.5
S-4
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch ACFoam
II, FlintBoard, ENRGY 3
or H-Shield
Note 2 1 per
1.45 ft2
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
HA, D-IS, M-
OSFA, OB500
or CR-20
Flintlastic
Ultra
Glass SA
(Optional) SBS-AA,
SBS-TA, APP-TA
SBS-AA,
SBS-TA,
APP-TA
-52.5
S-5
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch ACFoam
II, FlintBoard ISO, H-
Shield or FlintBoard
ISOH.
FlintFast #12 or #14 with
FlintFast 3” Insulation Plates
1 per
1.45 ft2
Min. 1.5-inch ACFoam II,
FlintBoard ISO, H-Shield or
FlintBoard ISOH.
HA, D-IS, M-
OSFA, M-
PG1 or
OB500
SBS-SA-H (Optional) APP-TA APP-TA -67.5
S-6
Min. 22 ga., type B, Grade
40 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch ACFoam
II, FlintBoard ISO, H-
Shield or FlintBoard
ISOH
FlintFast #12 (steel only) or #14
HD with FlintFast 3” Insulation
Plates or Trufast #12 (steel only)
or HD with Trufast 3” Metal
Insulation Plates
1 per 1.6
ft2
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
D-IS, M-
OSFA, M-
PG1 or
OB500
SBS-SA-H (Optional) SBS-TA
or APP-TA
SBS-TA or
APP-TA -75.0
S-7
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch ENRGY 3
FlintFast #12 (steel only) or #14
HD with FlintFast 3” Insulation
Plates or Trufast #12 (steel only)
or HD with Trufast 3” Metal
Insulation Plates
1 per 1
ft2
Min. 0.5-inch SECUROCK
Gypsum-Fiber Roof Board
OB500, 4-
inch o.c. SBS-SA-H (Optional) SBS-TA
or APP-TA
SBS-TA or
APP-TA -90.0*
CONVENTIONAL SYSTEMS:
S-8
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 2-inch ACFoam II,
FlintBoard, ENRGY 3 or
H-Shield
Note 2 1 per 4
ft2
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
HA, D-IS, M-
OSFA, OB500
or CR-20
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-37.5*
S-9
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch ACFoam
II, FlintBoard, ENRGY 3
or H-Shield
Note 2 1 per 2
ft2
Min. 0.5-inch Structodek
High Density Fiberboard
Roof Insulation, min. 0.75-
inch FescoBoard
(homogeneous).
HA BP-AA or
SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 19 of 57
TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP
(psf) Type Fasteners Attach Type Attach Base Ply Cap
S-10
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch ACFoam
II, FlintBoard, ENRGY 3
or H-Shield
Note 2 1 per 2
ft2
Min. 0.25-inch Dens Deck
or Dens Deck Prime HA
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
S-11
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch ACFoam
II, FlintBoard, ENRGY 3
or H-Shield
Note 2 1 per 2
ft2
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
HA, D-IS, M-
OSFA, OB500
or CR-20
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
S-12
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 2-inch ACFoam II,
FlintBoard, ENRGY 3 or
H-Shield
Note 2 1 per 3.2
ft2
Min. 0.5-inch Structodek
High Density Fiberboard
Roof Insulation, min. 0.75-
inch FescoBoard
(homogeneous).
HA BP-AA or
SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
S-13
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 2-inch ACFoam II,
FlintBoard, ENRGY 3 or
H-Shield
Note 2 1 per 3.2
ft2
Min. 0.25-inch Dens Deck
or Dens Deck Prime HA
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
S-14
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch ACFoam
II, FlintBoard, ENRGY 3
or Mult-Max FA3
Note 2 1 per
1.33 ft2
Min. 0.75-inch FescoBoard
(homogeneous) HA BP-AA or
SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-52.5
S-15
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 2-inch ACFoam II,
FlintBoard, ENRGY 3 or
H-Shield
Note 2 1 per 1.6
ft2
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
HA, D-IS, M-
OSFA, OB500
or CR-20
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-60.0
S-16
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch ACFoam
II, FlintBoard, ENRGY 3
or Mult-Max FA3
Note 2 1 per
1.33 ft2
Min. 0.5-inch Structodek
High Density Fiberboard HA BP-AA or
SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-67.5
S-17
Min. 22 ga., type B, Grade
40 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch ACFoam
II, FlintBoard ISO, H-
Shield or FlintBoard
ISOH
FlintFast #12 (steel only) or #14
HD with FlintFast 3” Insulation
Plates or Trufast #12 (steel only)
or HD with Trufast 3” Metal
Insulation Plates
1 per 1.6
ft2
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
D-IS, M-
OSFA, M-
PG1 or
OB500
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-75.0
S-18
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch ENRGY 3
FlintFast #12 (steel only) or #14
HD with FlintFast 3” Insulation
Plates or Trufast #12 (steel only)
or HD with Trufast 3” Metal
Insulation Plates
1 per 1
ft2
Min. 0.5-inch SECUROCK
Gypsum-Fiber Roof Board
OB500, 4-
inch o.c.
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-90.0*
COLD-APPLIED SYSTEMS:
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 20 of 57
TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP
(psf) Type Fasteners Attach Type Attach Base Ply Cap
S-19
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 2-inch ACFoam II,
FlintBoard ISO, H-
Shield or FlintBoard
ISOH
FlintFast #12 (steel only) or #14
HD with FlintFast 3” Insulation
Plates or Trufast #12 (steel only)
or HD with Trufast 3” Metal
Insulation Plates
1 per 2
ft2
Min. 1.5-inch ACFoam III,
FlintBoard Iso Cold, H-
Shield CG or FlintBoard Iso
ColdH
OB500 or
CR-20 SBS-CA1 None SBS-CA1 -45.0*
S-20
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 2-inch ACFoam II,
FlintBoard ISO, H-
Shield or FlintBoard
ISOH
FlintFast #12 (steel only) or #14
HD with FlintFast 3” Insulation
Plates or Trufast #12 (steel only)
or HD with Trufast 3” Metal
Insulation Plates
1 per 2
ft2
Optional min. 1.5-inch
additional layer(s) base
insulation, followed by
min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
D-IS, M-
OSFA, M-
PG1, OB500
or CR-20
SBS-CA1 None SBS-CA1 -45.0*
S-21
Min. 22 ga., type B, Grade
40 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch ACFoam
II, FlintBoard ISO, H-
Shield or FlintBoard
ISOH
FlintFast #12 (steel only) or #14
HD with FlintFast 3” Insulation
Plates or Trufast #12 (steel only)
or HD with Trufast 3” Metal
Insulation Plates
1 per 1.6
ft2
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
D-IS, M-
OSFA, M-
PG1 or
OB500
SBS-CA1 None SBS-CA1 -75.0
S-22
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch ENRGY 3
FlintFast #12 (steel only) or #14
HD with FlintFast 3” Insulation
Plates or Trufast #12 (steel only)
or HD with Trufast 3” Metal
Insulation Plates
1 per 1
ft2
Min. 0.5-inch SECUROCK
Gypsum-Fiber Roof Board
OB500, 4-
inch o.c. SBS-CA1 None SBS-CA1 -90.0*
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 21 of 57
TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1) Base Insulation Layer(s) Top Insulation Layer Roof Cover (Note 14) MDP
(psf) Type Fasteners Attach Base Ply Cap
SELF-ADHERING SYSTEMS:
S-23
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch
SECUROCK Gypsum-
Fiber Roof Board
Note 2 1 per 3.2 ft2 SBS-SA (Optional) SBS-SA SBS-SA -30.0*
S-24
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch
SECUROCK Gypsum-
Fiber Roof Board
FlintFast #12 (steel only) or
#14 HD with FlintFast 3”
Insulation Plates or Trufast #12
(steel only) or HD with Trufast
3” Metal Insulation Plates
1 per 2.7 ft2 SBS-SA (Optional) SBS-SA SBS-SA -37.5*
S-25
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 3/8-inch
SECUROCK Gypsum-
Fiber Roof Board
Note 2 1 per 2.7 ft2 SBS-SA (Optional) SBS-SA SBS-SA -45.0*
S-26
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch Dens
Deck Note 2 1 per 1.33 ft2
Apply FlintPrime or
FlintPrime SA to
board & plates,
followed by SBS-SA
(Optional) SBS-SA SBS-SA -45.0
S-27
Min. 22 ga., type B, Grade
40 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch
FlintBoard ISO
FlintFast #14 HD with FlintFast
3” Insulation Plates or Trufast
HD with Trufast 3” Metal
Insulation Plates
1 per 1.78 ft2
Apply FlintPrime to
board & plates,
followed by SBS-SA
(Optional) SBS-SA SBS-SA -67.5
S-28
Min. 22 ga., type B, Grade
40 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 0.5-inch
SECUROCK Gypsum-
Fiber Roof Board
FlintFast #14 HD with FlintFast
3” Insulation Plates or Trufast
HD with Trufast 3” Metal
Insulation Plates
1 per 1.6 ft2
Apply FlintPrime to
board & plates,
followed by SBS-SA
(Optional) SBS-SA SBS-SA -82.5
HYBRID SYSTEMS:
S-29
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch Dens
Deck; Dens Deck
Prime
Note 2 1 per 2 ft2 SBS-SA-H
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-30.0*
S-30
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch
SECUROCK Gypsum-
Fiber Roof Board
FlintFast #12 (steel only) or
#14 HD with FlintFast 3”
Insulation Plates or Trufast #12
(steel only) or HD with Trufast
3” Metal Insulation Plates
1 per 2.7 ft2 SBS-SA-H
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-37.5*
S-31
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 3/8-inch
SECUROCK Gypsum-
Fiber Roof Board
FlintFast #12 (steel only) or
#14 HD with FlintFast 3”
Insulation Plates or Trufast #12
(steel only) or HD with Trufast
3” Metal Insulation Plates
1 per 2.7 ft2 SBS-SA-H
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 22 of 57
TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1) Base Insulation Layer(s) Top Insulation Layer Roof Cover (Note 14) MDP
(psf) Type Fasteners Attach Base Ply Cap
S-32
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch ACFoam
II, FlintBoard ISO,
ENRGY 3 or Multi-Max
FA3
Note 2 1 per 1.33 ft2 SBS-SA-H (Optional) BP-AA
or SBS-AA SBS-AA -52.5
S-33
Min. 22 ga., type B, Grade
40 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch
FlintBoard ISO
FlintFast #14 HD with FlintFast
3” Insulation Plates or Trufast
HD with Trufast 3” Metal
Insulation Plates
1 per 1.78 ft2 SBS-SA-H (Optional) SBS-TA
or APP-TA
SBS-TA or
APP-TA -67.5
S-34
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch ACFoam
II, FlintBoard ISO, H-
Shield or FlintBoard
ISOH.
FlintFast #12 (steel only) or
#14 HD with FlintFast 3”
Insulation Plates
1 per 1.45 ft2 SBS-SA-H (Optional) SBS-AA,
SBS-TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-75.0
S-35
Min. 22 ga., type B, Grade
40 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 0.5-inch
SECUROCK Gypsum-
Fiber Roof Board
FlintFast #14 HD with FlintFast
3” Insulation Plates or Trufast
HD with Trufast 3” Metal
Insulation Plates
1 per 1.6 ft2 SBS-SA-H (Optional) SBS-TA
or APP-TA
SBS-TA or
APP-TA -82.5
S-36
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 0.5-inch
SECUROCK Gypsum-
Fiber Roof Board
FlintFast #12 (steel only) or
#14 HD with FlintFast 3”
Insulation Plates or Trufast #12
(steel only) or HD with Trufast
3” Metal Insulation Plates
1 per 1.45 ft2 SBS-SA-H (Optional) SBS-TA
or APP-TA
SBS-TA or
APP-TA -82.5
S-37
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch ACFoam
II, FlintBoard ISO,
ENRGY 3 or Multi-Max
FA3
Note 2 1 per 1.33 ft2 SBS-SA-H (Optional) SBS-TA
or APP-TA
SBS-TA or
APP-TA -82.5
S-38
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 0.5-inch
SECUROCK Gypsum-
Fiber Roof Board
FlintFast #12 (steel only) or
#14 HD with FlintFast 3”
Insulation Plates or Trufast #12
(steel only) or HD with Trufast
3” Metal Insulation Plates
1 per 1 ft2 SBS-SA-H (Optional) SBS-TA
or APP-TA
SBS-TA or
APP-TA -135.0
CONVENTIONAL SYSTEMS:
S-39
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 0.75-inch
FescoBoard
(homogeneous)
Note 2 1 per 2.67 ft2 BP-AA, SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-30.0*
S-40
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 0.5-inch
Structodek High
Density Fiberboard
Roof Insulation
Note 2 1 per 4 ft2 BP-AA, SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-37.5*
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 23 of 57
TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1) Base Insulation Layer(s) Top Insulation Layer Roof Cover (Note 14) MDP
(psf) Type Fasteners Attach Base Ply Cap
S-41
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch
SECUROCK Gypsum-
Fiber Roof Board
Note 2 1 per 4 ft2 BP-AA, SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-37.5*
S-42
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 2-inch ACFoam II,
FlintBoard or ENRGY 3 Note 2 1 per 1.6 ft2 BP-AA2
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-37.5*
S-43
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch
SECUROCK Gypsum-
Fiber Roof Board
Note 2 1 per 4 ft2 BP-AA, SBS-AA,
SBS-TA or APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
S-44
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 0.5-inch
Structodek High
Density Fiberboard
Roof Insulation, min.
0.75-inch FescoBoard
(homogeneous)
Note 2 1 per 2 ft2 BP-AA or SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
S-45
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch Dens
Deck or Dens Deck
Prime
Note 2 1 per 2 ft2 BP-AA, SBS-AA,
SBS-TA or APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
S-46
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 1-inch
FescoBoard
(homogeneous) or
min. 1.5-inch
FescoBoard
(laminated)
Note 2 1 per 1.6 ft2 BP-AA2
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
S-47
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 0.5-inch
Structodek,
Structodek HD, GP HD
Roof Fiberboard or
Temple HD1 or HD6
Note 2 1 per 2 ft2 BP-AA2
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
S-48
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch ACFoam
II, FlintBoard Note 2 1 per 1.45 ft2 BP-AA3, 24-inch
grid
(Optional) BP-AA
or SBS-AA SBS-AA -52.5
S-49
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch ACFoam
II, FlintBoard Note 2 1 per 1.45 ft2 BP-AA3, 24-inch
grid BP-AA or SBS-AA SBS-TA -52.5
S-50
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional for Concrete or
Recover) Min. 1.5-inch,
One or more layers, any
combination, loose laid
Min. 0.25-inch
SECUROCK Gypsum-
Fiber Roof Board
FlintFast #12 (steel only) or
#14 HD with FlintFast 3”
Insulation Plates
1 per 1.45 ft2 APP-TA (Optional) APP-TA APP-TA -60.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 24 of 57
TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1) Base Insulation Layer(s) Top Insulation Layer Roof Cover (Note 14) MDP
(psf) Type Fasteners Attach Base Ply Cap
S-51
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional for Concrete or
Recover) Min. 2-inch
ACFoam II, FlintBoard, H-
Shield or ENRGY 3, loose
laid.
Min. 0.5-inch
SECUROCK Gypsum-
Fiber Roof Board
Note 2 1 per 1.78 ft2 BP-AA, SBS-AA,
SBS-TA or APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-60.0
S-52
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 0.5-inch
SECUROCK Gypsum-
Fiber Roof Board
FlintFast #12 (steel only) or
#14 HD with FlintFast 3”
Insulation Plates or Trufast #12
(steel only) or HD with Trufast
3” Metal Insulation Plates
1 per 1.45 ft2 BP-AA, SBS-AA,
SBS-TA or APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-82.5
S-53
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional for Concrete or
Recover) Min. 1.5-inch
ACFoam II, FlintBoard, H-
Shield
Min. 0.5-inch Dens
Deck Prime
Trufast HD with Trufast 3”
Metal Insulation Plates or
FlintFast #14 with FlintFast 3”
Insulation Plates
1 per 1.33 ft2 BP-AA, SBS-AA (Optional) BP-AA,
SBS-AA SBS-AA -112.5
S-54
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 0.5-inch
SECUROCK Gypsum-
Fiber Roof Board
FlintFast #12 (steel only) or
#14 HD with FlintFast 3”
Insulation Plates or Trufast #12
(steel only) or HD with Trufast
3” Metal Insulation Plates
1 per 1 ft2 BP-AA, SBS-AA,
SBS-TA or APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-135.0
S-55
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional for Concrete or
Recover) Min. 1.5-inch
ACFoam II, FlintBoard, H-
Shield
Min. 0.5-inch
SECUROCK Gypsum-
Fiber Roof Board
Trufast HD with Trufast 3”
Metal Insulation Plates or
FlintFast #14 with FlintFast 3”
Insulation Plates
1 per 1.33 ft2 BP-AA, SBS-AA (Optional) BP-AA,
SBS-AA SBS-AA -157.5
S-56
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional for Concrete or
Recover) Min. 1.5-inch
ACFoam II, FlintBoard, H-
Shield
Min. 0.5-inch Dens
Deck Prime
Trufast HD with Trufast 3”
Metal Insulation Plates or
FlintFast #14 with FlintFast 3”
Insulation Plates
1 per 1 ft2 BP-AA, SBS-AA (Optional) BP-AA,
SBS-AA SBS-AA -157.5
S-57
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional for Concrete or
Recover) Min. 1.5-inch
ACFoam II, FlintBoard, H-
Shield
Min. 0.5-inch
SECUROCK Gypsum-
Fiber Roof Board
Trufast HD with Trufast 3”
Metal Insulation Plates or
FlintFast #14 with FlintFast 3”
Insulation Plates
1 per 1 ft2 BP-AA, SBS-AA (Optional) BP-AA,
SBS-AA SBS-AA -172.5
COLD-APPLIED SYSTEMS:
S-58
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch
SECUROCK Gypsum-
Fiber Roof Board
FlintFast #12 (steel only) or
#14 HD with FlintFast 3”
Insulation Plates or Trufast #12
(steel only) or HD with Trufast
3” Metal Insulation Plates
1 per 2.7 ft2 SBS-CA1 None SBS-CA1 -37.5*
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 25 of 57
TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1) Base Insulation Layer(s) Top Insulation Layer Roof Cover (Note 14) MDP
(psf) Type Fasteners Attach Base Ply Cap
S-59
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch ACFoam
III, FlintBoard Iso Cold,
H-Shield CG or
FlintBoard Iso ColdH
FlintFast #12 (steel only) or
#14 HD with FlintFast 3”
Insulation Plates or Trufast #12
(steel only) or HD with Trufast
3” Metal Insulation Plates
1 per 2 ft2 SBS-CA1 None SBS-CA1 -45.0*
S-60
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 3/8-inch
SECUROCK Gypsum-
Fiber Roof Board
FlintFast #12 (steel only) or
#14 HD with FlintFast 3”
Insulation Plates or Trufast #12
(steel only) or HD with Trufast
3” Metal Insulation Plates
1 per 2.7 ft2 SBS-CA1 None SBS-CA1 -45.0*
S-61
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 0.5-inch
SECUROCK Gypsum-
Fiber Roof Board
FlintFast #12 (steel only) or
#14 HD with FlintFast 3”
Insulation Plates or Trufast #12
(steel only) or HD with Trufast
3” Metal Insulation Plates
1 per 1.45 ft2 SBS-CA1 None SBS-CA1 -82.5*
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 26 of 57
TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE D: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
NOTE: INSULATION OPTIONAL FOR RECOVER OR CONCRETE DECK APPLICATIONS (NOTE 14)
System
No.
Deck
(Note 1)
Insulation Layer(s) Base or Anchor Sheet Roof Cover (Note 14) MDP
(psf) Type Attach Base Fasteners Attach Ply Cap
SELF-ADHERING SYSTEMS:
S-62
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch, One
or more layers, any
combination
Prelim.
Attached Flintlastic SA NailBase Note 2
9-inch o.c. at min. 2-inch lap and
18-inch o.c. in two (2), equally
spaced, staggered center rows
(Optional) SBS-
SA SBS-SA -45.0*
S-63
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch, One
or more layers, any
combination
Prelim.
Attached Flintlastic SA NailBase Note 2
12-inch o.c. at min. 2-inch lap and
12-inch o.c. in two (2), equally
spaced, staggered center rows
(Optional) SBS-
SA SBS-SA -52.5*
S-64
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch, One
or more layers, any
combination
Prelim.
Attached Flintlastic SA NailBase Note 2
12-inch o.c. at min. 4-inch lap and
12-inch o.c. in two (2), equally
spaced, staggered center rows
(Optional) SBS-
SA SBS-SA -60.0*
S-65
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch, One
or more layers, any
combination
Prelim.
Attached
Flintlastic SA NailBase
(laid parallel to deck
flutes)
Note 2
8-inch o.c. at min. 4-inch lap and 8-
inch o.c. in two (2), equally spaced,
staggered center rows
(Optional) SBS-
SA SBS-SA -82.5*
CONVENTIONAL SYSTEMS:
S-66
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch, One
or more layers, any
combination
Prelim.
Attached
Glasbase; All
Weather/Empire Base;
Flexiglas Base; Flintlastic
Base 20; Yosemite
Note 2
12-inch o.c. at 4-inch lap and 36-
inch o.c. in two (2), equally spaced,
staggered center rows
BP-AA, SBS-AA,
SBS-TA or APP-
TA
SBS-AA, SBS-
TA or APP-TA -30.0*
S-67
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch, One
or more layers, any
combination
Prelim.
Attached
Glasbase; All
Weather/Empire Base;
Flexiglas Base; Flintlastic
Base 20; Yosemite
Note 2
12-inch o.c. at 4-inch lap and 24-
inch o.c. in two (2), equally spaced,
staggered center rows
BP-AA, SBS-AA,
SBS-TA or APP-
TA
SBS-AA, SBS-
TA or APP-TA -45.0*
S-68
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch, One
or more layers, any
combination
Prelim.
Attached
Poly SMS Base; Ultra Poly
SMS Base Note 2
12-inch o.c. at 4-inch lap and 36-
inch o.c. in two (2), equally spaced,
staggered center rows
BP-AA, SBS-AA,
SBS-TA or APP-
TA
SBS-AA, SBS-
TA or APP-TA -45.0*
S-69
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch, One
or more layers, any
combination
Prelim.
Attached
Poly SMS Base; Ultra Poly
SMS Base Note 2
18-inch o.c. at 4-inch lap and 18-
inch o.c. in one (1) staggered
center row
BP-AA, SBS-AA,
SBS-TA or APP-
TA
SBS-AA, SBS-
TA or APP-TA -45.0*
S-70
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch, One
or more layers, any
combination
Prelim.
Attached
Poly SMS Base; Ultra Poly
SMS Base
Dekfast IF-2-SB plates with
#14 Dekfast
12-inch o.c. within the min. 4-inch
wide, heat-welded side lap
SBS-AA, SBS-TA
or APP-TA
SBS-AA, SBS-
TA or APP-TA -45.0*
S-71
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch, One
or more layers, any
combination
Prelim.
Attached
Glasbase; Flexiglas Base;
Flintlastic Base 20; All
Weather / Empire Base;
Poly SMS Base; Yosemite
Note 2
12-inch o.c. at 3-inch lap and 12-
inch o.c. in two (2), equally spaced,
staggered center rows
BP-AA, SBS-AA,
SBS-TA or APP-
TA
SBS-AA, SBS-
TA or APP-TA -52.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 27 of 57
TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE D: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
NOTE: INSULATION OPTIONAL FOR RECOVER OR CONCRETE DECK APPLICATIONS (NOTE 14)
System
No.
Deck
(Note 1)
Insulation Layer(s) Base or Anchor Sheet Roof Cover (Note 14) MDP
(psf) Type Attach Base Fasteners Attach Ply Cap
S-72
Min. 22 ga., type B, 40 ksi
steel or min. 2,500 psi
structrual concrete
Min. 2-inch, One or
more layers, any
combination
Prelim.
Attached Ultra Poly SMS Base
Trufast 2” Barbed Metal
Seam Plates with Trufast
#15 EHD (steel only) or
Trufast #14 HD (concrete
only)
12-inch o.c. within the min. 4-inch
wide, heat-welded side lap
(Optional) SBS-
TA or APP-TA
SBS-TA or
APP-TA -52.5
S-73
Min. 22 ga., type B, Grade
80 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch, One
or more layers, any
combination
Prelim.
Attached Ultra Poly SMS Base
Trufast 2.4” Barbed Metal
Seam Plates with Trufast
#15 EHD (steel only) or
Trufast #14 HD (concrete
only)
12-inch o.c. within the min. 4-inch
wide, heat-welded side lap
(Optional) SBS-
TA or APP-TA
SBS-TA or
APP-TA -60.0
S-74
Min. 22 ga., type B, 40 ksi
steel or min. 2,500 psi
structrual concrete
Min. 2-inch, One or
more layers, any
combination
Prelim.
Attached Ultra Poly SMS Base
Trufast 2.4” Scoop Seam
Plates with Trufast #15
EHD (steel only) or Trufast
#14 HD (concrete only)
12-inch o.c. within the min. 4-inch
wide, heat-welded side lap
(Optional) SBS-
TA or APP-TA
SBS-TA or
APP-TA -67.5
S-75
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch, One
or more layers, any
combination
Prelim.
Attached Glasbase; Yosemite
OMG Flat Bottom Plates
with OMG #14 HD
(Accutrac)
6-inch o.c. at 4-inch lap and 6-inch
o.c. in two (2), equally spaced,
staggered center rows
BP-AA, SBS-AA,
SBS-TA or APP-
TA
SBS-AA, SBS-
TA or APP-TA -67.5
S-76
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch, One
or more layers, any
combination
Prelim.
Attached
Flexiglas Base; Flintlastic
Base 20; Yosemite Note 2
6-inch o.c. at 4-inch lap and 6-inch
o.c. in two (2), equally spaced,
staggered center rows
BP-AA, SBS-AA,
SBS-TA or APP-
TA
SBS-AA, SBS-
TA or APP-TA -67.5
S-77
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch, One
or more layers, any
combination
Prelim.
Attach
Glasbase; Flexiglas;
Flintlastic Base 20; All
Weather / Empire Base;
Poly SMS Base; Ultra Poly
SMS Base; Yosemite
Flintfast 3 in. Insulation
Plates with FlintFast #14;
Trufast 3" Metal Insulation
Plates with Trufast HD
6-inch o.c. at 4-inch lap and 6-inch
o.c. at three (3) equally spaced,
staggered center rows
(Optional) BP-
AA, SBS-AA or
SBS-TA
SBS-AA or
SBS-TA -97.5
S-78
Min. 22 ga., type B, 40 ksi
steel or min. 2,500 psi
structrual concrete
Min. 2-inch, One or
more layers, any
combination
Prelim.
Attached Ultra Poly SMS Base
Trufast 2.4” Scoop Seam
Plates with Trufast #15
EHD (steel only) or Trufast
#14 HD (concrete only)
6-inch o.c. within the min. 4-inch
wide, heat-welded side lap
(Optional) SBS-
TA or APP-TA
SBS-TA or
APP-TA -112.5
S-79
Min. 22 ga., type B, Grade
80 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch, One
or more layers, any
combination
Prelim.
Attached
Poly SMS Base; Ultra Poly
SMS Base Note 2
12-inch o.c. at 4-inch lap and 12-
inch o.c. in two (2), equally spaced,
staggered center rows
SBS-TA or APP-
TA
SBS-TA or
APP-TA -112.5
S-80
Min. 22 ga., type B, Grade
80 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch, One
or more layers, any
combination
Prelim.
Attached
Poly SMS Base; Ultra Poly
SMS Base Note 2
12-inch o.c. at 4-inch lap and 12-
inch o.c. in two (2), equally spaced,
staggered center rows
SBS-AA SBS-AA or
SBS-TA -120.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 28 of 57
TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE D: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
NOTE: INSULATION OPTIONAL FOR RECOVER OR CONCRETE DECK APPLICATIONS (NOTE 14)
System
No.
Deck
(Note 1)
Insulation Layer(s) Base or Anchor Sheet Roof Cover (Note 14) MDP
(psf) Type Attach Base Fasteners Attach Ply Cap
S-81
Min. 22 ga., type B, 40 ksi
steel or min. 2,500 psi
structrual concrete
Min. 2-inch, One or
more layers, any
combination
Prelim.
Attached Ultra Poly SMS Base
Trufast 2.4” Scoop Seam
Plates with Trufast #15
EHD (steel only) or Trufast
#14 HD (concrete only)
6-inch o.c. within the min. 4-inch
wide, heat-welded side laps and 6-
inch o.c. in one (1) center row,
stripped-in with 6-inch side strips
of torch-applied Poly SMS Base or
Ultra Poly SMS Base.
(Optional) SBS-
TA or APP-TA
SBS-TA or
APP-TA -165.0
COLD-APPLIED SYSTEMS:
S-82
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch, One
or more layers, any
combination
Prelim.
Attached
Glasbase; All
Weather/Empire Base;
Flexiglas Base; Flintlastic
Base 20
Note 2
6-inch o.c. at 4-inch lap and 12-
inch o.c. in two (2), equally spaced,
staggered center rows
SBS-CA1 SBS-CA1 -45.0*
S-83
Min. 22 ga., type B, Grade
40 steel or min. 2,500 psi
structrual concrete
Min. 1-inch, One or
more layers, any
combination
Loose-laid
Glasbase; Flexiglas Base;
Flintlastic Base 20; All
Weather / Empire Base;
Yosemite Venting Base;
Flintlastic Poly SMS Base;
Flintlastic Ultra Poly SMS
Base
FlintFast #14 HD with
FlintFast 3” Insulation
Plates or Trufast HD with
Trufast 3” Metal Insulation
Plates
6-inch o.c. at 4-inch lap and 12-
inch o.c. in three (3), equally
spaced, staggered center rows
(Optional) SBS-
CA1 SBS-CA1 -75.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 29 of 57
TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
Sys.
No.
Deck
(Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP
(psf) Type Attach Type Attach Base Ply Cap
SELF-ADHERING SYSTEMS:
C-1. Structural
concrete
FlintPrime
(ASTM D41)
Min. 1.5-inch ACFoam II, FlintBoard,
ENRGY 3 or H-Shield HA Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board HA SBS-SA (Optional) SBS-SA SBS-SA -172.5
C-2. Structural
concrete
FlintPrime
(ASTM D41)
Min. 1.5-inch ACFoam II, FlintBoard,
ENRGY 3 or Multi-Max FA3 HA Min. 0.25-inch Dens Deck primed
with FlintPrime or FlintPrime SA HA SBS-SA (Optional) SBS-SA SBS-SA -192.5
C-3. Structural
concrete None Min. 1.5-inch ACFoam II, FlintBoard,
ENRGY 3 or Multi-Max FA3 A-PD Min. 0.25-inch Dens Deck primed
with FlintPrime or FlintPrime SA A-PD SBS-SA (Optional) SBS-SA SBS-SA -105.0
C-4. Structural
concrete None Min. 1.5-inch ACFoam II, FlintBoard,
ENRGY 3 or H-Shield A-PD Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board A-PD SBS-SA (Optional) SBS-SA SBS-SA -172.5
C-5. Structural
concrete None Min. 1.5-inch ACFoam II, FlintBoard,
ENRGY 3 or Multi-Max FA3
A-PD
6-inch o.c.
Min. 0.25-inch Dens Deck primed
with FlintPrime or FlintPrime SA
A-PD
6-inch o.c. SBS-SA (Optional) SBS-SA SBS-SA -192.5
C-6. Structural
concrete
(Optional)
FlintPrime
(ASTM D41)
Min. 1.5-inch Multi-Max FA D-IS Min. 0.25-inch Dens Deck primed
with FlintPrime or FlintPrime SA D-IS SBS-SA (Optional) SBS-SA SBS-SA -67.5
C-7. Structural
concrete
(Optional)
FlintPrime
(ASTM D41)
Min. 1.5-inch ENRGY 3 D-IS Min. 0.25-inch Dens Deck primed
with FlintPrime or FlintPrime SA D-IS SBS-SA (Optional) SBS-SA SBS-SA -112.5
C-8. Structural
concrete
(Optional)
FlintPrime
(ASTM D41)
Min. 1.5-inch ACFoam II or FlintBoard D-IS Min. 0.25-inch Dens Deck primed
with FlintPrime or FlintPrime SA D-IS SBS-SA (Optional) SBS-SA SBS-SA -120.0
C-9. Structural
concrete None Min. 1.5-inch ACFoam II, FlintBoard,
ENRGY 3 or H-Shield D-IS Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board D-IS SBS-SA (Optional) SBS-SA SBS-SA -172.5
C-10. Structural
concrete None Min. 1.5-inch ACFoam II, FlintBoard,
ENRGY 3 or H-Shield
M-OSFA or
M-PG1
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board
M-OSFA or
M-PG1 SBS-SA (Optional) SBS-SA SBS-SA -172.5
C-11. Structural
concrete None Min. 1.5-inch ACFoam II, FlintBoard,
ENRGY 3 or Multi-Max FA
M-OSFA or
M-PG1
Min. 0.25-inch Dens Deck primed
with FlintPrime or FlintPrime SA
M-OSFA or
M-PG1 SBS-SA (Optional) SBS-SA SBS-SA -192.5
C-12. Structural
concrete
FlintPrime
(ASTM D41)
Min. 1.5-inch ACFoam II, FlintBoard ISO
or ENRGY 3 OB500 Min. 0.25-inch Dens Deck primed
with FlintPrime or FlintPrime SA OB500 SBS-SA (Optional) SBS-SA SBS-SA -120.0
C-13. Structural
concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO
or ENRGY 3 OB500 Min. 0.25-inch Dens Deck primed
with FlintPrime or FlintPrime SA OB500 SBS-SA (Optional) SBS-SA SBS-SA -150.0
C-14. Structural
concrete None Min. 1.5-inch ACFoam II, FlintBoard,
ENRGY 3 or H-Shield OB500 Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board OB500 SBS-SA (Optional) SBS-SA SBS-SA -172.5
C-15. Structural
concrete None
Min. 1.0-inch ISO 95+ GL, H-Shield, H-
Shield CG, ENRGY 3 or min. 1.3-inch
ACFoam III, Min. 1.5-inch Multi-Max
FA3 or Ultra-Max
CR-20 Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board CR-20 SBS-SA (Optional) SBS-SA SBS-SA -172.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 30 of 57
TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
Sys.
No.
Deck
(Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP
(psf) Type Attach Type Attach Base Ply Cap
C-16. Structural
concrete None
Min. 1.0-inch ISO 95+ GL, H-Shield, H-
Shield CG, ENRGY 3 or min. 1.3-inch
ACFoam III, Min. 1.5-inch Multi-Max
FA3 or Ultra-Max
CR-20 Min. 0.25-inch Dens Deck primed
with FlintPrime or FlintPrime SA CR-20 SBS-SA (Optional) SBS-SA SBS-SA -192.5
HYBRID SYSTEMS:
C-17. Structural
concrete
FlintPrime
(ASTM D41)
Min. 1.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOH HA (Optional) Additional layer(s) base
insulation HA
Flintlastic
Ultra Glass
SA
(Optional) SBS-AA,
SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA -322.5
C-18. Structural
concrete
FlintPrime
(ASTM D41)
Min. 1.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOH HA (Optional) Additional layer(s) base
insulation HA
Black
Diamond
Base Sheet
(Optional) SBS-AA,
SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA -375.0
C-19. Structural
concrete None Min. 1.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOH A-PD (Optional) Additional layer(s) base
insulation A-PD SBS-SA-H (Optional) SBS-AA,
SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA -180.0
C-20. Structural
concrete None Min. 1.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOH A-PD Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board A-PD SBS-SA-H (Optional) SBS-AA,
SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA -117.5
C-21. Structural
concrete None Min. 1.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOH
A-PD, 6-inch
o.c.
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board
A-PD, 6-inch
o.c. SBS-SA-H (Optional) SBS-AA,
SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA -217.5
C-22. Structural
concrete None Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board
A-PD, 6-inch
o.c. None N/A SBS-SA-H (Optional) SBS-AA,
SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA -195.0
C-23. Structural
concrete None Min. 1.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOH D-IS (Optional) Additional layer(s) base
insulation D-IS SBS-SA-H (Optional) SBS-AA,
SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA -135.0
C-24. Structural
concrete None Min. 1.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOH D-IS Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board D-IS SBS-SA-H (Optional) SBS-AA,
SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA -217.5
C-25. Structural
concrete None Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board D-IS None N/A SBS-SA-H (Optional) SBS-AA,
SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA -195.0
C-26. Structural
concrete None Min. 1.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOH M-OSFA (Optional) Additional layer(s) base
insulation M-OSFA SBS-SA-H (Optional) SBS-AA,
SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA -232.5
C-27. Structural
concrete None Min. 1.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOH M-OSFA Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board M-OSFA SBS-SA-H (Optional) SBS-AA,
SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA -217.5
C-28. Structural
concrete None Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board M-OSFA None N/A SBS-SA-H (Optional) SBS-AA,
SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA -195.0
C-29. Structural
concrete None Min. 1.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOH M-PG1 (Optional) Additional layer(s) base
insulation M-PG1 SBS-SA-H (Optional) SBS-AA,
SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA -270.0
C-30. Structural
concrete None Min. 1.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOH M-PG1 Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board M-PG1 SBS-SA-H (Optional) SBS-AA,
SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA -217.5
C-31. Structural
concrete None Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board M-PG1 None N/A SBS-SA-H (Optional) SBS-AA,
SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA -195.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 31 of 57
TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
Sys.
No.
Deck
(Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP
(psf) Type Attach Type Attach Base Ply Cap
C-32. Structural
concrete None Min. 1.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOH OB500 (Optional) Additional layer(s) base
insulation OB500 SBS-SA-H (Optional) SBS-AA,
SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA -135.0
C-33. Structural
concrete None Min. 1.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOH OB500 Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board OB500 SBS-SA-H (Optional) SBS-AA,
SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA -217.5
C-34. Structural
concrete None Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board OB500 None N/A SBS-SA-H (Optional) SBS-AA,
SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA -195.0
C-35. Structural
concrete None Min. 1.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOH CR-20 (Optional) Additional layer(s) base
insulation CR-20 SBS-SA-H (Optional) SBS-AA,
SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA -270.0
C-36. Structural
concrete None Min. 1.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOH CR-20 Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board CR-20 SBS-SA-H (Optional) SBS-AA,
SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA -217.5
C-37. Structural
concrete None Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board CR-20 None N/A SBS-SA-H (Optional) SBS-AA,
SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA -195.0
CONVENTIONAL SYSTEMS:
C-38. Structural
concrete
FlintPrime
(ASTM D41)
Min. 1.5-inch ACFoam II, ENRGY 3, H-
Shield, FlintBoard ISO HA (Optional) Additional layer(s) of
base insulation HA BP-AA3, 24-
inch grid
(Optional) BP-AA,
SBS-AA SBS-AA -37.5
C-39. Structural
concrete
FlintPrime
(ASTM D41)
Min. 1.5-inch ACFoam II or FlintBoard
ISO. HA Min. 0.25-inch Dens Deck, Dens
Deck Prime HA SBS-TA (Optional) SBS-TA SBS-TA -180.0
C-40. Structural
concrete
FlintPrime
(ASTM D41)
(Optional) Min. 1.5-inch ACFoam II or
FlintBoard ISO. HA Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board HA
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -180.0
C-41. Structural
concrete
FlintPrime
(ASTM D41)
(Optional) Min. 2-inch ACFoam II,
FlintBoard ISO, ENRGY 3 or H-Shield HA Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board HA BP-AA or
SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -225.0
C-42. Structural
concrete
FlintPrime
(ASTM D41)
(Optional) Min. 1.5-inch ACFoam II,
FlintBoard ISO, H-Shield, FlintBoard
ISOH
HA Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board HA APP-TA (Optional) APP-TA APP-TA -252.5
C-43. Structural
concrete
FlintPrime
(ASTM D41)
Min. 1.5-inch ACFoam II, FlintBoard
ISO, ENRGY 3 or H-Shield HA Min. 0.5-inch Structodek High
Density Fiberboard HA BP-AA or
SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -227.0
C-44. Structural
concrete
FlintPrime
(ASTM D41)
(Optional) Min. 2-inch ACFoam II,
FlintBoard ISO, ENRGY 3 or H-Shield HA Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board HA SBS-TA or
APP-TA
(Optional) SBS-TA
or APP-TA
SBS-TA or
APP-TA -232.5
C-45. Structural
concrete
FlintPrime
(ASTM D41)
Min. 1.5-inch ACFoam II, FlintBoard
ISO, ENRGY 3 or H-Shield HA Min. 0.25-inch Dens Deck HA BP-AA or
SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -240.0
C-46. Structural
concrete
FlintPrime
(ASTM D41)
Min. 1.5-inch ACFoam II or FlintBoard
ISO HA Min. 0.75-inch FescoBoard
(homogeneous) HA BP-AA or
SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -412.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 32 of 57
TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
Sys.
No.
Deck
(Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP
(psf) Type Attach Type Attach Base Ply Cap
C-47. Structural
concrete
FlintPrime
(ASTM D41)
Min. 1.5-inch ACFoam II or FlintBoard
ISO HA Min. 0.5-inch DuraBoard
(homogeneous) HA BP-AA or
SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -430.0
C-48. Structural
concrete
FlintPrime
(ASTM D41)
0.5-inch Structodek High Density
Fiberboard or min. 0.75-inch Fesco
Board (homogeneous)
HA None N/A BP-AA (Optional) BP-AA or
SBS-AA SBS-AA -437.5
C-49. Structural
concrete
FlintPrime
(ASTM D41)
0.25-inch Dens Deck, Dens Deck Prime
or SECUROCK Gypsum-Fiber Roof Board HA None N/A SBS-TA (Optional) SBS-AA
or SBS-TA
SBS-AA or
SBS-TA -302.5
C-50. Structural
concrete
FlintPrime
(ASTM D41)
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board HA None N/A
Flintlastic
Ultra Poly
SMS Base,
torched
(Optional) Flintlastic
Ultra Poly SMS
Base, torched
SBS-TA -487.5
C-51. Structural
concrete
FlintPrime
(ASTM D41)
0.25-inch Dens Deck, Dens Deck Prime
or SECUROCK Gypsum-Fiber Roof Board HA None N/A BP-AA (Optional) BP-AA or
SBS-AA SBS-AA -537.5
C-52. Structural
concrete None Min. 1.5-inch ACFoam II, FlintBoard
ISO, ENRGY 3 or H-Shield A-PD
Min. 0.5-inch Structodek High
Density Fiberboard or Min. 0.25-
inch Dens Deck
A-PD BP-AA or
SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -105.0
C-53. Structural
concrete None Min. 1.5-inch ACFoam II, FlintBoard
ISO, ENRGY 3 or H-Shield
A-PD
6-inch o.c.
Min. 0.5-inch Structodek High
Density Fiberboard or Min. 0.25-
inch Dens Deck
A-PD
6-inch o.c.
BP-AA or
SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -217.5
C-54. Structural
concrete None Min. 1.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOH A-PD Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board A-PD
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -117.5
C-55. Structural
concrete None Min. 1.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOH
A-PD, 6-inch
o.c.
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board
A-PD, 6-inch
o.c.
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -217.5
C-56. Structural
concrete None 0.5-inch Structodek High Density
Fiberboard
A-PD, 6-inch
o.c. None N/A BP-AA, SBS-
AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -195.0
C-57. Structural
concrete None
Min. 0.25-inch Dens Deck, Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof
Board
A-PD, 6-inch
o.c. None N/A
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -195.0
C-58. Structural
concrete None Min. 1.5-inch ACFoam II or FlintBoard
ISO. D-IS Min. 0.25-inch Dens Deck D-IS SBS-TA (Optional) SBS-TA SBS-TA -112.5
C-59. Structural
concrete None Min. 1.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOH D-IS Min. 0.25-inch Dens Deck Prime D-IS BP-AA, SBS-
AA
(Optional) BP-AA,
SBS-AA or SBS-TA
SBS-AA or
SBS-TA -297.5
C-60. Structural
concrete None Min. 1.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOH D-IS Min. 0.25-inch Dens Deck Prime D-IS SBS-TA (Optional) SBS-TA SBS-TA -302.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 33 of 57
TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
Sys.
No.
Deck
(Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP
(psf) Type Attach Type Attach Base Ply Cap
C-61. Structural
concrete None Min. 2-inch ACFoam II, FlintBoard ISO,
ENRGY 3 or H-Shield D-IS Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board D-IS BP-AA or
SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -225.0
C-62. Structural
concrete None Min. 2-inch ACFoam II, FlintBoard ISO,
ENRGY 3 or H-Shield D-IS Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board D-IS SBS-TA or
APP-TA
(Optional) SBS-TA
or APP-TA
SBS-TA or
APP-TA -232.5
C-63. Structural
concrete None Min. 1.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOH D-IS Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board D-IS APP-TA (Optional) APP-TA APP-TA -252.5
C-64. Structural
concrete None Min. 1.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOH D-IS Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board D-IS
BP-AA, SBS-
AA or SBS-
TA
(Optional) BP-AA,
SBS-AA or SBS-TA
SBS-AA or
SBS-TA -297.5
C-65. Structural
concrete None 0.5-inch Structodek High Density
Fiberboard D-IS None N/A BP-AA, SBS-
AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -195.0
C-66. Structural
concrete None Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board D-IS None N/A
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -195.0
C-67. Structural
concrete None Min. 1.5-inch ACFoam II, FlintBoard
ISO, ENRGY 3 or H-Shield M-OSFA Min. 0.5-inch Structodek High
Density Fiberboard M-OSFA BP-AA or
SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -127.5
C-68. Structural
concrete None Min. 1.5-inch ACFoam II, FlintBoard
ISO, ENRGY 3 or H-Shield M-PG1 Min. 0.5-inch Structodek High
Density Fiberboard M-PG1 BP-AA or
SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -180.0
C-69. Structural
concrete None Min. 1.5-inch ACFoam II, FlintBoard
ISO, ENRGY 3 or H-Shield M-OSFA Min. 0.25-inch Dens Deck M-OSFA BP-AA or
SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -232.5
C-70. Structural
concrete None Min. 1.5-inch ACFoam II, FlintBoard
ISO, ENRGY 3 or H-Shield M-PG1 Min. 0.25-inch Dens Deck M-PG1 BP-AA or
SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -240.0
C-71. Structural
concrete None Min. 1.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOH M-PG1 Min. 0.25-inch Dens Deck Prime M-PG1 BP-AA, SBS-
AA
(Optional) BP-AA,
SBS-AA or SBS-TA
SBS-AA or
SBS-TA -297.5
C-72. Structural
concrete None Min. 1.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOH M-PG1 Min. 0.25-inch Dens Deck Prime M-PG1 SBS-TA (Optional) SBS-TA SBS-TA -302.5
C-73. Structural
concrete None Min. 2-inch ACFoam II, FlintBoard ISO,
ENRGY 3 or H-Shield
M-OSFA or
M-PG1
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board
M-OSFA or
M-PG1
BP-AA or
SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -225.0
C-74. Structural
concrete None Min. 2-inch ACFoam II, FlintBoard ISO,
ENRGY 3 or H-Shield
M-OSFA or
M-PG1
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board
M-OSFA or
M-PG1
SBS-TA or
APP-TA
(Optional) SBS-TA
or APP-TA
SBS-TA or
APP-TA -232.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 34 of 57
TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
Sys.
No.
Deck
(Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP
(psf) Type Attach Type Attach Base Ply Cap
C-75. Structural
concrete None Min. 1.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOH
M-OSFA or
M-PG1
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board
M-OSFA or
M-PG1 APP-TA (Optional) APP-TA APP-TA -252.5
C-76. Structural
concrete None Min. 1.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOH
M-OSFA or
M-PG1
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board
M-OSFA or
M-PG1
BP-AA, SBS-
AA or SBS-
TA
(Optional) BP-AA,
SBS-AA or SBS-TA
SBS-AA or
SBS-TA -297.5
C-77. Structural
concrete None 0.5-inch Structodek High Density
Fiberboard M-PG1 None N/A BP-AA, SBS-
AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -195.0
C-78. Structural
concrete None Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board M-PG1 None N/A
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -195.0
C-79. Structural
concrete None Min. 1.5-inch ACFoam II, FlintBoard
ISO, ENRGY 3 or H-Shield OB500 Min. 0.5-inch Structodek High
Density Fiberboard OB500 BP-AA or
SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -120.0
C-80. Structural
concrete None Min. 1.5-inch ACFoam II or FlintBoard
ISO. OB500 Min. 0.25-inch Dens Deck or Dens
Deck Prime OB500
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -150.0
C-81. Structural
concrete None Min. 1.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOH OB500 Min. 0.25-inch Dens Deck Prime OB500
BP-AA, SBS-
AA or SBS-
TA
(Optional) BP-AA,
SBS-AA or SBS-TA
SBS-AA or
SBS-TA -297.5
C-82. Structural
concrete None Min. 2-inch ACFoam II, FlintBoard ISO,
ENRGY 3 or H-Shield OB500 Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board OB500 BP-AA or
SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -225.0
C-83. Structural
concrete None Min. 2-inch ACFoam II, FlintBoard ISO,
ENRGY 3 or H-Shield OB500 Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board OB500 SBS-TA or
APP-TA
(Optional) SBS-TA
or APP-TA
SBS-TA or
APP-TA -232.5
C-84. Structural
concrete None Min. 1.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOH OB500 Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board OB500 APP-TA (Optional) APP-TA APP-TA -252.5
C-85. Structural
concrete None Min. 1.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOH OB500 Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board OB500
BP-AA, SBS-
AA or SBS-
TA
(Optional) BP-AA,
SBS-AA or SBS-TA
SBS-AA or
SBS-TA -297.5
C-86. Structural
concrete None 0.5-inch Structodek High Density
Fiberboard OB500 None N/A BP-AA, SBS-
AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -195.0
C-87. Structural
concrete None Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board OB500 None N/A
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -195.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 35 of 57
TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
Sys.
No.
Deck
(Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP
(psf) Type Attach Type Attach Base Ply Cap
C-88. Structural
concrete None
Min. 1.0-inch ISO 95+ GL, H-Shield, H-
Shield CG, ENRGY 3 or min. 1.3-inch
ACFoam III, Min. 1.5-inch Multi-Max
FA3 or Ultra-Max
CR-20
Min. 0.5-inch Structodek High
Density Fiberboard or DuraBoard
(homogeneous) or min. 1.5-inch
FescoBoard (laminated)
CR-20 BP-AA or
SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -180.0
C-89. Structural
concrete None
Min. 1.0-inch ISO 95+ GL, H-Shield, H-
Shield CG, ENRGY 3 or min. 1.3-inch
ACFoam III, Min. 1.5-inch Multi-Max
FA3 or Ultra-
CR-20 Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board CR-20 BP-AA or
SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -225.0
C-90. Structural
concrete None
Min. 1.0-inch ISO 95+ GL, H-Shield, H-
Shield CG, ENRGY 3 or min. 1.3-inch
ACFoam III, Min. 1.5-inch Multi-Max
FA3 or Ultra-Max
CR-20 Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board CR-20 SBS-TA or
APP-TA
(Optional) SBS-TA
or APP-TA
SBS-TA or
APP-TA -232.5
C-91. Structural
concrete None
Min. 1.0-inch ISO 95+ GL, H-Shield, H-
Shield CG, ENRGY 3 or min. 1.3-inch
ACFoam III, Min. 1.5-inch Multi-Max
FA3 or Ultra-Max
CR-20 Min. 0.25-inch Dens Deck CR-20 BP-AA or
SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -240.0
C-92. Structural
concrete None 0.5-inch Structodek High Density
Fiberboard CR-20 None N/A BP-AA, SBS-
AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -195.0
C-93. Structural
concrete None Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board CR-20 None N/A
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -195.0
COLD-APPLIED SYSTEMS:
C-94. Structural
concrete None
(Optional) Min. 0.5-inch ACFoam II,
FlintBoard ISO, H-Shield, FlintBoard
ISOH
OB500 or
CR-20
Min. 1.5-inch ACFoam III,
FlintBoard Iso Cold, H-Shield CG or
FlintBoard Iso ColdH
OB500 or
CR-20 SBS-CA1 None SBS-CA1 -82.5
C-95. Structural
concrete None Min. 0.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOH
A-PD, D-IS,
M-OSFA, M-
PG1, OB500
or CR-20
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board
A-PD, D-IS,
M-OSFA, M-
PG1, OB500
or CR-20
SBS-CA1 None SBS-CA1 -105.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 36 of 57
TABLE 3B: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-3: BONDED TEMP ROOF, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1) Primer / Temp Roof Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP (psf) Type Attach Type Attach Base Ply Cap
COLD-APPLIED SYSTEMS:
C-96. Structural
concrete
FlintPrime
(ASTM
D41)
Flintlastic SA
PlyBase, self-
adhered
(Optional) Min. 0.5-inch
ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard
ISOH
OB500
Min. 1.5-inch ACFoam III,
FlintBoard Iso Cold, H-Shield
CG or FlintBoard Iso ColdH
OB500 SBS-CA1 None SBS-CA1 -82.5
C-97. Structural
concrete
FlintPrime
(ASTM
D41)
Flintlastic SA
PlyBase, self-
adhered
Min. 0.5-inch ACFoam II,
FlintBoard ISO, H-Shield,
FlintBoard ISOH
OB500 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -82.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 37 of 57
TABLE 3C: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER
System
No.
Deck
(Note 1) Primer Roof Cover (Note 14) MDP (psf) Base Ply Cap
SELF-ADHERING SYSTEMS:
C-98. Structural concrete FlintPrime SA SBS-SA (Optional) SBS-SA SBS-SA -555.0
C-99. Structural concrete FlintPrime (ASTM D41) SBS-SA (Optional) SBS-SA SBS-SA -630.0
HYBRID SYSTEMS:
C-100. Structural concrete FlintPrime SA Flintlastic Ultra Glass SA (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -52.5
C-101. Structural concrete FlintPrime (ASTM D41) Flintlastic Ultra Glass SA (Optional) SBS-AA SBS-AA -135.0
C-102. Structural concrete FlintPrime (ASTM D41) Black Diamond Base Sheet (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -150.0
C-103. Structural concrete FlintPrime (ASTM D41) Flintlastic Ultra Glass SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -322.5
C-104. Structural concrete FlintPrime (ASTM D41) Black Diamond Base Sheet (Optional) BP-AA, SBS-AA SBS-AA -240.0
C-105. Structural concrete FlintPrime (ASTM D41) BP-AA, SBS-AA SBS-SA-H SBS-AA, SBS-TA, APP-TA -635.0
CONVENTIONAL SYSTEMS:
C-106. Structural concrete FlintPrime (ASTM D41) APP-TA (Optional) APP-TA APP-TA -420.0
C-107. Structural concrete FlintPrime (ASTM D41) SBS-TA (Optional) SBS-TA SBS-TA -542.5
C-108. Structural concrete FlintPrime (ASTM D41) BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -635.0
COLD-APPLIED SYSTEMS:
C-109. Structural concrete FlintPrime (ASTM D41) SBS-CA1 (Optional) SBS-CA1 SBS-CA1 -262.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 38 of 57
TABLE 4A: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Lightweight Concrete
(Note 13)
Base Insulation Layer Coverboard Roof Cover (Note 14) MDP
(psf) Type Attach Type Attach Base Ply Cap
SELF-ADHERING SYSTEMS:
LWC-1 Concrete Min. 200 psi, min. 2-inch
Elastizell
Min. 1.5-inch ACFoam II,
FlintBoard, ENRGY 3 or H-Shield
A-PD, 6-
inch o.c.
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
A-PD, 6-
inch o.c. SBS-SA (Optional) SBS-SA SBS-SA -172.5
LWC-2 Concrete Min. 200 psi, min. 2-inch
Elastizell
Min. 1.5-inch ACFoam II,
FlintBoard, ENRGY 3 or Multi-Max
FA3
A-PD, 6-
inch o.c.
Min. 0.25-inch Dens Deck
primed with FlintPrime or
FlintPrime SA
A-PD, 6-
inch o.c. SBS-SA (Optional) SBS-SA SBS-SA -187.5
LWC-3 Concrete Min. 200 psi, min. 2-inch
Elastizell
Min. 1.5-inch ACFoam II,
FlintBoard ISO or ENRGY 3 OB500
Min. 0.25-inch Dens Deck
primed with FlintPrime or
FlintPrime SA
OB500 SBS-SA (Optional) SBS-SA SBS-SA -150.0
LWC-4 Concrete Min. 200 psi, min. 2-inch
Elastizell
Min. 1.5-inch ACFoam II,
FlintBoard, ENRGY 3 or H-Shield OB500 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-SA SBS-SA -172.5
LWC-5 Concrete Min. 200 psi, min. 2-inch
Celcore, Elastizell or Celcore
Min. 1.0-inch ISO 95+ GL, H-Shield,
H-Shield CG, ENRGY 3 or min. 1.3-
inch ACFoam III, Min. 1.5-inch
Multi-Max FA3 or Ultra-Max
CR-20 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board CR-20 SBS-SA (Optional) SBS-SA SBS-SA -172.5
LWC-6 Concrete Min. 200 psi, min. 2-inch
Celcore, Elastizell or Celcore
Min. 1.0-inch ISO 95+ GL, H-Shield,
H-Shield CG, ENRGY 3 or min. 1.3-
inch ACFoam III, Min. 1.5-inch
Multi-Max FA3 or Ultra-Max
CR-20
Min. 0.25-inch Dens Deck
primed with FlintPrime or
FlintPrime SA
CR-20 SBS-SA (Optional) SBS-SA SBS-SA -180.0
CONVENTIONAL SYSTEMS:
LWC-7 Concrete Min. 200 psi, min. 2-inch
Elastizell
Min. 1.5-inch ACFoam II,
FlintBoard ISO, ENRGY 3 or H-
Shield
A-PD
6-inch
o.c.
Min. 0.5-inch Structodek
High Density Fiberboard or
Min. 0.25-inch Dens Deck
A-PD
6-inch
o.c.
BP-AA or SBS-
AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -187.5
LWC-8 Concrete Min. 200 psi, min. 2-inch
Elastizell
Min. 1.5-inch ACFoam II,
FlintBoard ISO, ENRGY 3 or H-
Shield
A-PD, 6-
inch o.c.
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
A-PD, 6-
inch o.c.
BP-AA or SBS-
AA, SBS-TA or
APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -217.5
LWC-9 Concrete Min. 200 psi, min. 2-inch
Elastizell
Min. 1.5-inch ACFoam II or
FlintBoard ISO. OB500 Min. 0.25-inch Dens Deck
or Dens Deck Prime OB500
BP-AA, SBS-
AA, SBS-TA or
APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -150.0
LWC-10 Concrete Min. 200 psi, min. 2-inch
Elastizell
Min. 1.5-inch ACFoam II or
FlintBoard ISO. OB500 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 SBS-TA (Optional) SBS-TA SBS-TA -180.0
LWC-11 Concrete Min. 200 psi, min. 2-inch
Elastizell
Min. 2-inch ACFoam II, FlintBoard
ISO, ENRGY 3 or H-Shield OB500 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500
BP-AA, SBS-
AA, SBS-TA or
APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -225.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 39 of 57
TABLE 4A: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Lightweight Concrete
(Note 13)
Base Insulation Layer Coverboard Roof Cover (Note 14) MDP
(psf) Type Attach Type Attach Base Ply Cap
LWC-12 Concrete Min. 200 psi, min. 2-inch
Celcore, Elastizell or Celcore
Min. 1.0-inch ISO 95+ GL, H-Shield,
H-Shield CG, ENRGY 3 or min. 1.3-
inch ACFoam III, Min. 1.5-inch
Multi-Max FA3 or Ultra-Max
CR-20
Min. 0.5-inch Structodek
High Density Fiberboard or
DuraBoard (homogeneous)
or min. 1.5-inch
FescoBoard (laminated)
CR-20 BP-AA or SBS-
AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -180.0
LWC-13 Concrete Min. 200 psi, min. 2-inch
Celcore, Elastizell or Celcore
Min. 1.0-inch ISO 95+ GL, H-Shield,
H-Shield CG, ENRGY 3 or min. 1.3-
inch ACFoam III, Min. 1.5-inch
Multi-Max FA3 or Ultra-Max
CR-20
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
or Dens Deck or Dens Deck
Prime
CR-20
BP-AA, SBS-
AA, SBS-TA or
APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -180.0
COLD APPLIED SYSTEMS:
LWC-14
Min. 22 ga.
steel at max
5 ft spans or
structural
concrete
Min. 350 psi, min 2-inch
Range II Elastizell Lightweight
Insulating Concrete with Zell
Fibers.
Min. 1.5-inch H-Shield CG
OB500,
6-inch
o.c.
(Optional) Additional
layers of base insulation
OB500,
6-inch
o.c.
BP-CA3 or
SBS-CA3
(Optional) BP-CA3
or SBS-CA3 SBS-CA3 -60.0
LWC-15
Min. 22 ga.
steel at max
5 ft spans or
structural
concrete
Min. 350 psi, min 2-inch
Range II Elastizell Lightweight
Insulating Concrete with Zell
Fibers. When walkable,
attach LWC with Flintfast #14
and Flintfast 3” Round Plates
at 1 per 8 ft2 through to the
structural deck.
Min. 1.5-inch H-Shield CG
OB500,
6-inch
o.c.
(Optional) Additional
layers of base insulation
OB500,
6-inch
o.c.
BP-CA3 or
SBS-CA3
(Optional) BP-CA3
or SBS-CA3 SBS-CA3 -67.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 40 of 57
TABLE 4B: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION or REROOF (Tear-Off)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
LWC
(Note 13)
Anchor Sheet Insulation Roof Cover (Note 14) MDP (psf) Type Fasteners Attach Base Top Attach Base Ply Cap
LWC-16
Min. 22 ga.
steel or
structural
concrete deck.
Minimum 350 psi,
minimum 2-inch
Elastizell cellular LWIC
Yosemite
Venting
Base
ES FM-90
Base Ply
Fasteners
7-inch o.c. at the 4-inch
side lap and 7-inch o.c.
at two, equally spaced,
staggered rows in the
center of the sheet
Min. 1.5-
inch
ACFoam II
(Optional)
Additional
layers base
insulation
Hot
asphalt
BP-AA3, 18-
inch grid
(Optional)
BP-AA,
SBS-AA
SBS-AA -37.5*
LWC-17
Min. 22 ga.
steel or
structural
concrete deck.
Minimum 350 psi,
minimum 2-inch
Approved or existing
cellular LWIC Note: To
qualify the LWIC under
this assembly, the
subject fastener shall
achieve an average
withdrawal of 88 lbf
when tested per TAS
105 or ANSI/SPRI FX-1.
Yosemite
Venting
Base
ES Twin-Loc
Nails
9-inch o.c. at the 4-inch
side lap and 9-inch o.c.
at two, equally spaced,
staggered rows in the
center of the sheet
Min. 1.5-
inch
ACFoam II
(Optional)
Additional
layers base
insulation
Hot
asphalt
BP-AA4, 18-
inch o.c.
(Optional)
BP-AA,
SBS-AA
SBS-AA -60.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 41 of 57
TABLE 4C: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1) Lightweight Concrete (Note 13) Base Sheet Roof Cover (Note 14) MDP (psf) Type Fasteners Attach Ply Cap
SELF-ADHERING SYSTEMS:
LWC-18
Min. 22 ga.
steel at max
5 ft spans or
structural
concrete
Min. 300 psi, min. 2-inch Approved cellular
lightweight insulating concrete. Note: To qualify
the LWIC under this assembly, a 1.8-inch Trufast
Twin Loc-Nail Assembled Fastener shall achieve an
average withdrawal of 73 lbf when tested per TAS
105 or ANSI/SPRI FX-1
Flintlastic SA NailBase
Trufast Twin Loc-Nail
Assembled Fastener
(min. 1.8”)
7-inch o.c. at the min. 2-inch lap and 7-inch
o.c. in two (2), equally spaced, staggered
center rows; Stress plates shall be primed
with FlintPrime (ASTM D41) primer or
FlintPrime SA
SBS-SA SBS-SA -60.0
LWC-19
Min. 22 ga.
steel at max
5 ft spans or
structural
concrete
Min. 300 psi, min. 2-inch Approved cellular
lightweight insulating concrete. Note: To qualify
the LWIC under this assembly, a 1.8-inch Trufast
Twin Loc-Nail Assembled Fastener shall achieve an
average withdrawal of 93 lbf when tested per TAS
105 or ANSI/SPRI FX-1
Flintlastic SA NailBase
Trufast Twin Loc-Nail
Assembled Fastener
(min. 1.8”)
9-inch o.c. at the min. 2-inch lap and 9-inch
o.c. in two (2), equally spaced, staggered
center rows; Stress plates shall be primed
with FlintPrime (ASTM D41) primer or
FlintPrime SA
SBS-SA SBS-SA -60.0
HYBRID SYSTEMS:
LWC-20
Min. 26 ga.
steel at max
5 ft spans or
structural
concrete
Min. 200 psi, min 2-inch Range II Elastizell
Lightweight Insulating Concrete.
Glasbase; Flexiglas
Base; Flintlastic Base
20; All Weather /
Empire Base or Poly
SMS Base
Trufast FM-90 Base
Sheet Fasteners or
Trufast Twin Loc-Nail
Assembled Fasteners
(1.8 inch)
7½-inch o.c. at the 4-inch lap and 7½-inch
o.c. in two (2), equally spaced, staggered
center rows
SBS-SA-H
SBS-AA,
SBS-TA or
APP-TA
-30.0
LWC-21
Min. 22 ga.
steel at max
5 ft spans or
structural
concrete
Min. 200 psi, min 2-inch Range II Elastizell
Lightweight Insulating Concrete.
Glasbase; Flexiglas
Base; Flintlastic Base
20; All Weather /
Empire Base or Poly
SMS Base
Trufast FM-90 Base
Sheet Fasteners or
Trufast Twin Loc-Nail
Assembled Fasteners
(1.8 inch)
7-inch o.c. at the 4-inch lap and 7-inch o.c. in
two (2), equally spaced, staggered center
rows
SBS-SA-H
SBS-AA,
SBS-TA or
APP-TA
-45.0
LWC-22
Min. 22 ga.
steel at max
5 ft spans or
structural
concrete
Min. 300 psi, min. 2-inch Approved cellular
lightweight insulating concrete. Note: To qualify
the LWIC under this assembly, a 1.8-inch Trufast
Twin Loc-Nail Assembled Fastener shall achieve an
average withdrawal of 88 lbf when tested per TAS
105 or ANSI/SPRI FX-1
Glasbase; Flexiglas
Base; Flintlastic Base
20; All Weather /
Empire Base
Trufast Twin Loc-Nail
Assembled Fastener
(min. 1.8”)
9-inch o.c. at the 4-inch lap and 9-inch o.c. in
two (2), equally spaced, staggered center
rows
SBS-SA-H
SBS-AA,
SBS-TA or
APP-TA
-60.0
LWC-23
Min. 22 ga.
steel at max
5 ft spans or
structural
concrete
Min. 350 psi, min. 3-inch Approved cellular
lightweight insulating concrete. Note: To qualify
the LWIC under this assembly, a 1.8-inch Trufast
Twin Loc-Nail Assembled Fastener shall achieve an
average withdrawal of 97 lbf when tested per TAS
105 or ANSI/SPRI FX-1
Flexiglas Base;
Flintlastic Base 20 or
Poly SMS Base
Trufast FM-90 Base
Sheet Fasteners
7-inch o.c. at the 4-inch lap and 10-inch o.c.
in two (2), equally spaced, staggered center
rows
SBS-SA-H
SBS-AA,
SBS-TA or
APP-TA
-67.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 42 of 57
TABLE 4C: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1) Lightweight Concrete (Note 13) Base Sheet Roof Cover (Note 14) MDP (psf) Type Fasteners Attach Ply Cap
LWC-24
Min. 22 ga.
steel at max
5 ft spans or
structural
concrete
Min. 300 psi, min. 2-inch Approved cellular
lightweight insulating concrete. Note: To qualify
the LWIC under this assembly, a 1.8-inch Trufast
Twin Loc-Nail Assembled Fastener shall achieve an
average withdrawal of 110 lbf when tested per TAS
105 or ANSI/SPRI FX-1
Poly SMS Base; Ultra
Poly SMS Base
Trufast Twin Loc-Nail
Assembled Fastener
(min. 1.8”)
9-inch o.c. at the 4-inch lap and 9-inch o.c. in
two (2), equally spaced, staggered center
rows
SBS-SA-H
SBS-AA,
SBS-TA or
APP-TA
-75.0
CONVENTIONAL SYSTEMS:
LWC-25
Min. 26 ga.
steel at max
5 ft spans or
structural
concrete
Min. 200 psi, min 2-inch Range II Elastizell
Lightweight Insulating Concrete.
Glasbase; Flexiglas
Base; Flintlastic Base
20; All Weather /
Empire Base; Poly
SMS Base; Yosemite
Trufast FM-90 Base
Sheet Fasteners or
Trufast Twin Loc-Nail
Assembled Fasteners
(1.8 inch)
7½-inch o.c. at the 4-inch lap and 7½-inch
o.c. in two (2), equally spaced, staggered
center rows
(Optional)
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-30.0
LWC-26
Min. 26 ga.
steel at max
5 ft spans or
structural
concrete
Min. 200 psi, min 2-inch Range II Elastizell
Lightweight Insulating Concrete. Flintlastic APP Base T Trufast FM-90 Base
Sheet Fasteners
7½-inch o.c. at the 4-inch lap and 7½-inch
o.c. in two (2), equally spaced, staggered
center rows
(Optional)
APP-TA APP-TA -30.0
LWC-27
Min. 22 ga.
steel at max
5 ft spans or
structural
concrete
Min. 200 psi, min 2-inch Range II Elastizell
Lightweight Insulating Concrete.
Glasbase; Flexiglas
Base; Flintlastic Base
20; All Weather /
Empire Base; Poly
SMS Base; Yosemite
Trufast FM-90 Base
Sheet Fasteners or
Trufast Twin Loc-Nail
Assembled Fasteners
(1.8 inch)
7-inch o.c. at the 4-inch lap and 7-inch o.c. in
two (2), equally spaced, staggered center
rows
(Optional)
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0
LWC-28
Min. 22 ga.
steel at max
5 ft spans or
structural
concrete
Min. 200 psi, min 2-inch Range II Elastizell
Lightweight Insulating Concrete. Flintlastic APP Base T Trufast FM-90 Base
Sheet Fasteners
7-inch o.c. at the 4-inch lap and 7-inch o.c. in
two (2), equally spaced, staggered center
rows
(Optional)
APP-TA APP-TA -45.0
LWC-29
Min. 22 ga.
steel at max
5 ft spans or
structural
concrete
Min. 250 psi, min 2-inch Mearlcrete.
Glasbase; Flexiglas
Base; Flintlastic Base
20; All Weather /
Empire Base; Poly
SMS Base; Yosemite
OMG CR Base Ply
Fasteners (1.7)
7-inch o.c. at the 4-inch lap and 7-inch o.c. in
two (2), equally spaced, staggered center
rows
(Optional)
BP-AA or
SBS-AA
SBS-AA,
SBS-TA or
APP-TA
-45.0
LWC-30
Min. 22 ga.
steel at max
5 ft spans or
structural
concrete
Min. 250 psi, min 2-inch Mearlcrete. Poly SMS Base OMG CR Base Ply
Fasteners (1.7)
7-inch o.c. at the 4-inch lap and 7-inch o.c. in
two (2), equally spaced, staggered center
rows
(Optional)
BP-AA or
SBS-AA
SBS-AA,
SBS-TA or
APP-TA
-52.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 43 of 57
TABLE 4C: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1) Lightweight Concrete (Note 13) Base Sheet Roof Cover (Note 14) MDP (psf) Type Fasteners Attach Ply Cap
LWC-31
Min. 22 ga.
steel at max
5 ft spans or
structural
concrete
Min. 300 psi, min 2-inch Mearlcrete.
Glasbase; Flexiglas
Base; Flintlastic Base
20; All Weather /
Empire Base; Poly
SMS Base; Yosemite
OMG CR Base Ply
Fasteners (1.7)
7-inch o.c. at the 4-inch lap and 7-inch o.c. in
two (2), equally spaced, staggered center
rows
(Optional)
BP-AA or
SBS-AA
SBS-AA,
SBS-TA or
APP-TA
-52.5
LWC-32
Min. 22 ga.
steel at max
5 ft spans or
structural
concrete
Concrecel Bonding Agent on deck; Min. 300 psi, min
2¼-inch Concrecel Concrete.
Glasbase; Flexiglas
Base; Flintlastic Base
20; All Weather /
Empire Base; Poly
SMS Base; Yosemite
OMG CR Base Ply
Fasteners (1.7)
7-inch o.c. at the 3-inch lap and 7-inch o.c. in
two (2), equally spaced, staggered center
rows
(Optional)
BP-AA or
SBS-AA
SBS-AA,
SBS-TA or
APP-TA
-52.5
LWC-33
Min. 22 ga.
steel at max
5 ft spans or
structural
concrete
Min. 300 psi, min. 2-inch Approved cellular
lightweight insulating concrete. Note: To qualify
the LWIC under this assembly, a 1.8-inch Trufast
Twin Loc-Nail Assembled Fastener shall achieve an
average withdrawal of 88 lbf when tested per TAS
105 or ANSI/SPRI FX-1
Glasbase; Flexiglas
Base; Flintlastic Base
20; All Weather /
Empire Base;
Yosemite
Trufast Twin Loc-Nail
Assembled Fastener
(min. 1.8”)
9-inch o.c. at the 4-inch lap and 9-inch o.c. in
two (2), equally spaced, staggered center
rows
(Optional)
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-60.0
LWC-34
Min. 22 ga.,
type B steel
at max. 5 ft
spans
structural
concrete
Min. 300 psi, min 2-inch Celcore MF Cellular
Concrete with Celcore HS Rheology Modifying
Admixture. After setting to support foot traffic,
Celcore PVA Curing Compound is applied.
All Weather / Empire
Base; Flintlastic Base
20; Poly SMS Base
Trufast FM-90 Base
Sheet Fasteners
9-inch o.c. at 4-inch laps and 12-inch o.c. in
two (2), equally spaced, staggered center
rows
(Optional)
BP-AA,
SBS-AA or
SBS-TA-F
SBS-AA or
SBS-TA-F -60.0
LWC-35
Min. 22 ga.
steel at max
5 ft spans or
structural
concrete
Min. 300 psi, min. 2-inch Approved cellular
lightweight insulating concrete. Note: To qualify
the LWIC under this assembly, a 1.8-inch Trufast
Twin Loc-Nail Assembled Fastener shall achieve an
average withdrawal of 77 lbf when tested per TAS
105 or ANSI/SPRI FX-1
Glasbase; Flexiglas
Base; Flintlastic Base
20; All Weather /
Empire Base;
Yosemite
Trufast Twin Loc-Nail
Assembled Fastener
(min. 1.8”)
7-inch o.c. at the 4-inch lap and 7-inch o.c. in
two (2), equally spaced, staggered center
rows
BP-AA or
SBS-AA
SBS-AA,
SBS-TA or
APP-TA
-67.5
LWC-36
Min. 22 ga.
steel at max
5 ft spans or
structural
concrete
Min. 350 psi, min. 3-inch Approved cellular
lightweight insulating concrete. Note: To qualify
the LWIC under this assembly, a 1.8-inch Trufast
Twin Loc-Nail Assembled Fastener shall achieve an
average withdrawal of 97 lbf when tested per TAS
105 or ANSI/SPRI FX-1
Flexiglas Base;
Flintlastic Base 20;
Poly SMS Base;
Yosemite
Trufast FM-90 Base
Sheet Fasteners
7-inch o.c. at the 4-inch lap and 10-inch o.c.
in two (2), equally spaced, staggered center
rows
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-67.5
LWC-37
Min. 22 ga.
steel at max
5 ft spans or
structural
concrete
Min. 300 psi, min. 2-inch Approved cellular
lightweight insulating concrete. Note: To qualify
the LWIC under this assembly, a 1.8-inch Trufast
Twin Loc-Nail Assembled Fastener shall achieve an
average withdrawal of 110 lbf when tested per TAS
105 or ANSI/SPRI FX-1
Poly SMS Base; Ultra
Poly SMS Base
Trufast Twin Loc-Nail
Assembled Fastener
(min. 1.8”)
9-inch o.c. at the 4-inch lap and 9-inch o.c. in
two (2), equally spaced, staggered center
rows
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-75.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 44 of 57
TABLE 4C: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1) Lightweight Concrete (Note 13) Base Sheet Roof Cover (Note 14) MDP (psf) Type Fasteners Attach Ply Cap
LWC-38
Min. 22 ga.
steel at max
5 ft spans or
structural
concrete
Min. 300 psi, min 2-inch Celcore Cellular Concrete.
After setting to support foot traffic, Celcore PVA
Curing Compound is applied.
Glasbase; Flexiglas
Base; Flintlastic Base
20; All Weather /
Empire Base; Poly
SMS Base; Yosemite
Trufast FM-90 Base
Sheet Fasteners
7-inch o.c. at the 3-inch lap and 7-inch o.c. in
two (2), equally spaced, staggered center
rows
BP-AA or
SBS-AA
SBS-AA,
SBS-TA or
APP-TA
-75.0
COLD APPLIED SYSTEMS:
LWC-39
Min. 22 ga.
steel at max
5 ft spans or
structural
concrete
Min. 350 psi, min 2-inch Range II Elastizell
Lightweight Insulating Concrete with Zell Fibers.
Flintlastic Base 20;
Poly SMS Base
Trufast FM-90 Base
Sheet Fasteners
7-inch o.c. at the 4-inch lap and 7-inch o.c. in
two (2), equally spaced, staggered center
rows
(Optional)
BP-CA2 or
SBS-CA2
SBS-CA2 -45.0
LWC-40
Min. 22 ga.
steel at max
5 ft spans
Min. 350 psi, min 2-inch Range II Elastizell
Lightweight Insulating Concrete with Zell Fibers.
Glasbase; Flexiglas
Base; Poly SMS Base
Trufast FM-90 Base
Sheet Fasteners
7-inch o.c. at the 4-inch lap and 7-inch o.c. in
two (2), equally spaced, staggered center
rows
(Optional)
BP-CA3 or
SBS-CA3
SBS-CA3 -52.5
LWC-41 Structural
concrete
Min. 350 psi, min 2-inch Range II Elastizell
Lightweight Insulating Concrete with Zell Fibers.
Glasbase; Flexiglas
Base; Poly SMS Base
Trufast FM-90 Base
Sheet Fasteners
7-inch o.c. at the 4-inch lap and 7-inch o.c. in
two (2), equally spaced, staggered center
rows
(Optional)
BP-CA3 or
SBS-CA3
SBS-CA3 -60.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 45 of 57
TABLE 5A: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP (psf) Type Attach Type Attach Base Ply Cap
SELF-ADHERING SYSTEMS:
CWF-1. Tectum Min. 1.5-inch FlintBoard ISO, ACFoam II, ENRGY 3 or Multi-
Max FA3 OB500
Min. 0.25-inch Dens Deck primed with
FlintPrime or FlintPrime SA; or SECUROCK
Gypsum-Fiber Roof Board
OB500 SBS-SA (Optional) SBS-SA SBS-SA -45.0*
CWF-2. Tectum
Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG, ENRGY 3
or min. 1.3-inch ACFoam III, Min. 1.5-inch Multi-Max FA3
or Ultra-Max
CR-20
Min. 0.25-inch Dens Deck primed with
FlintPrime or FlintPrime SA; or SECUROCK
Gypsum-Fiber Roof Board
CR-20 SBS-SA (Optional) SBS-SA SBS-SA -52.5
CONVENTIONAL SYSTEMS:
CWF-3. Tectum Min. 1.5-inch FlintBoard ISO, ACFoam II, ENRGY 3 or Multi-
Max FA3 OB500 Min. 0.5-inch Structodek High Density
Fiberboard OB500 BP-AA or
SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
CWF-4. Tectum Min. 1.5-inch FlintBoard ISO, ACFoam II, ENRGY 3 or Multi-
Max FA3 OB500
Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board or Dens Deck or Dens Deck
Prime
OB500
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
CWF-5. Tectum
Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG, ENRGY 3
or min. 1.3-inch ACFoam III, Min. 1.5-inch Multi-Max FA3
or Ultra-
CR-20
Min. 0.5-inch Structodek High Density
Fiberboard or DuraBoard (homogeneous)
or min. 1.5-inch FescoBoard (laminated)
CR-20 BP-AA or
SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-52.5
CWF-6. Tectum
Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG, ENRGY 3
or min. 1.3-inch ACFoam III, Min. 1.5-inch Multi-Max FA3
or Ultra-Max
CR-20
Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board or Dens Deck or Dens Deck
Prime
CR-20
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-52.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 46 of 57
TABLE 5B: CEMENTITIOUS WOOF FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 14) MDP (psf) Type Fasteners Attach Type Attach Type Attach Base Ply Cap
HYBRID SYSTEMS:
CWF-7. Tectum
Glasbase; Flexiglas
Base; Flintlastic Base
20; All Weather /
Empire Base; Yosemite
Trufast Twin
Loc-Nail
Assembled
Fastener
(min. 1.8”)
7-inch o.c. at the 4-
inch lap and 7-inch
o.c. in two (2),
equally spaced,
staggered center
rows
Min. 1.5-inch
ACFoam II,
FlintBoard ISO,
ENRGY 3 or Multi-
Max FA3
HA
(Optional) Min. 0.25-
inch SECUROCK
Gypsum-Fiber Roof
Board
HA SBS-SA-
H
(Optional)
SBS-AA,
SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-60.0
CONVENTIONAL SYSTEMS:
CWF-8. Tectum
Glasbase; Flexiglas
Base; Flintlastic Base
20; All Weather /
Empire Base; Yosemite
Trufast Twin
Loc-Nail
Assembled
Fastener
(min. 1.8”)
7-inch o.c. at the 4-
inch lap and 7-inch
o.c. in two (2),
equally spaced,
staggered center
rows
Min. 1.5-inch
ACFoam II,
FlintBoard ISO,
ENRGY 3 or Multi-
Max FA3
HA
Min. 0.75-inch
FescoBoard
(homogeneous) or min.
0.5-inch Structodek
High Density Fiberboard
HA
BP-AA
or SBS-
AA
(Optional)
BP-AA or
SBS-AA
SBS-AA,
SBS-TA or
APP-TA
-60.0
TABLE 5C: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1) Base Insulation Layer(s) Top Insulation Layer Roof Cover (Note 14) MDP (psf) Type Fasteners Attach Base Ply Cap
CWF-9. Tectum
(Optional) One or more
layers, any combination,
loose laid
Min. 0.5-inch Structodek High
Density Fiberboard Roof
Insulation
OMG Polymer GypTec with 3”
GypTec Plate 1 per 2 ft2 BP-AA or SBS-
AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
CWF-10. Tectum
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch Dens Deck or
Dens Deck Prime
OMG Polymer GypTec with 3”
GypTec Plate 1 per 1.78 ft2
BP-AA, SBS-
AA, SBS-TA or
APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
CWF-11. Tectum
(Optional) One or more
layers, any combination,
loose laid
Min. 0.5-inch Structodek High
Density Fiberboard Roof
Insulation
Trufast Twin Loc-Nail
Assembled Fasteners
(minimum 1-inch embedment
into deck)
1 per 2 ft2 BP-AA or SBS-
AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
CWF-12. Tectum
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch Dens Deck or
Dens Deck Prime or
SECUROCK Gypsum-Fiber
Roof Board
Trufast Twin Loc-Nail
Assembled Fasteners
(minimum 1-inch embedment
into deck)
1 per 2 ft2
BP-AA, SBS-
AA, SBS-TA or
APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 47 of 57
TABLE 5D: CEMENTITOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Sheet Roof Cover (Note 14) MDP (psf) Base Fasteners Attach Ply Cap
SELF-ADHERING SYSTEMS:
CWF-13. Tectum Flintlastic SA NailBase
Trufast Twin Loc-Nail
Assembled Fastener (min.
1.8”)
7-inch o.c. at the 4-inch lap and 7-inch o.c. in two
(2), equally spaced, staggered center rows SBS-SA SBS-SA -60.0
CONVENTIONAL SYSTEMS:
CWF-14. Tectum All Weather / Empire Base; Yosemite Trufast Insuldeck Loc-Nail Base
Sheet Fastener
9-inch o.c. at the 4-inch lap and 12-inch o.c. in two
(2), equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA -30.0*
CWF-15. Tectum All Weather / Empire Base; Yosemite Trufast Insuldeck Loc-Nail Base
Sheet Fastener
7½-inch o.c. at the 4-inch lap and 7½-inch o.c. in
two (2), equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA -45.0*
CWF-16. Tectum Glasbase; Flexiglas Base; All Weather /
Empire Base; Yosemite Simplex Turbo Tube-Lok 9-inch o.c. at the 4-inch lap and 12-inch o.c. in two
(2), equally spaced, staggered center rows
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
CWF-17. Tectum Glasbase; Flexiglas Base; Flintlastic Base
20 or All Weather / Empire Base; Yosemite
Trufast Twin Loc-Nail
Assembled Fastener (min.
1.8”)
7-inch o.c. at the 4-inch lap and 7-inch o.c. in two
(2), equally spaced, staggered center rows BP-AA or SBS-AA
SBS-AA,
SBS-TA or
APP-TA
-67.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 48 of 57
TABLE 6A: GYPSUM DECKS – REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No. Deck Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP (psf) Type Attach Type Attach Base Ply Cap
SELF-ADHERING SYSTEMS:
G-1.
Existing sound
gypsum or
gypsum plank
Min. 1.5-inch ACFoam II, FlintBoard, ENRGY 3 or H-
Shield M-OSFA Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board M-OSFA SBS-SA (Optional) SBS-SA SBS-SA -172.5
G-2.
Existing sound
gypsum or
gypsum plank
Min. 1.5-inch ACFoam II, FlintBoard, ENRGY 3 or
Multi-Max FA M-OSFA Min. 0.25-inch Dens Deck primed
with FlintPrime or FlintPrime SA M-OSFA SBS-SA (Optional) SBS-SA SBS-SA -192.5
G-3.
Existing sound
gypsum or
gypsum plank
Min. 1.5-inch ACFoam II, FlintBoard ISO or ENRGY 3 OB500
Min. 0.25-inch Dens Deck primed
with FlintPrime or FlintPrime SA
or SECUROCK Gypsum-Fiber Roof
Board
OB500 SBS-SA (Optional) SBS-SA SBS-SA -135.0
G-4.
Existing sound
gypsum or
gypsum plank
Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG,
ENRGY 3 or min. 1.3-inch ACFoam III, Min. 1.5-inch
Multi-Max FA3 or Ultra-Max
CR-20 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board CR-20 SBS-SA (Optional) SBS-SA SBS-SA -172.5
G-5.
Existing sound
gypsum or
gypsum plank
Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG,
ENRGY 3 or min. 1.3-inch ACFoam III, Min. 1.5-inch
Multi-Max FA3 or Ultra-Max
CR-20 Min. 0.25-inch Dens Deck primed
with FlintPrime or FlintPrime SA CR-20 SBS-SA (Optional) SBS-SA SBS-SA -192.5
CONVENTIONAL SYSTEMS:
G-6.
Existing sound
gypsum or
gypsum plank
Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or
H-Shield M-OSFA Min. 0.5-inch Structodek High
Density Fiberboard M-OSFA BP-AA or SBS-
AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-127.5
G-7.
Existing sound
gypsum or
gypsum plank
Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or
H-Shield M-OSFA Min. 0.25-inch Dens Deck M-OSFA BP-AA or SBS-
AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-232.5
G-8.
Existing sound
gypsum or
gypsum plank
Min. 2-inch ACFoam II, FlintBoard ISO, ENRGY 3 or
H-Shield M-OSFA Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board M-OSFA
BP-AA or SBS-
AA, SBS-TA or
APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-202.5
G-9.
Existing sound
gypsum or
gypsum plank
Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or
H-Shield OB500 Min. 0.5-inch Structodek High
Density Fiberboard OB500 BP-AA or SBS-
AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-120.0
G-10.
Existing sound
gypsum or
gypsum plank
Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or
H-Shield OB500
Min. 0.25-inch Dens Deck, Dens
Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
OB500
BP-AA, SBS-
AA, SBS-TA or
APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-135.0
G-11.
Existing sound
gypsum or
gypsum plank
Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG,
ENRGY 3 or min. 1.3-inch ACFoam III, Min. 1.5-inch
Multi-Max FA3 or Ultra-Max
CR-20 Min. 0.25-inch Dens Deck or Dens
Deck Prime CR-20 SBS-TA (Optional) SBS-TA SBS-TA -180.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 49 of 57
TABLE 6A: GYPSUM DECKS – REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No. Deck Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP (psf) Type Attach Type Attach Base Ply Cap
G-12.
Existing sound
gypsum or
gypsum plank
Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG,
ENRGY 3 or min. 1.3-inch ACFoam III, Min. 1.5-inch
Multi-Max FA3 or Ultra-Max
CR-20
Min. 0.5-inch Structodek High
Density Fiberboard or DuraBoard
(homogeneous) or min. 1.5-inch
FescoBoard (laminated)
CR-20 BP-AA or SBS-
AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-180.0
G-13.
Existing sound
gypsum or
gypsum plank
Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG,
ENRGY 3 or min. 1.3-inch ACFoam III, Min. 1.5-inch
Multi-Max FA3 or Ultra-Max
CR-20 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board CR-20 BP-AA or SBS-
AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-225.0
G-14.
Existing sound
gypsum or
gypsum plank
Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG,
ENRGY 3 or min. 1.3-inch ACFoam III, Min. 1.5-inch
Multi-Max FA3 or Ultra-Max
CR-20 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board CR-20 SBS-TA or
APP-TA
(Optional) SBS-TA
or APP-TA
SBS-TA or
APP-TA -232.5
G-15.
Existing sound
gypsum or
gypsum plank
Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG,
ENRGY 3 or min. 1.3-inch ACFoam III, Min. 1.5-inch
Multi-Max FA3 or Ultra-Max
CR-20 Min. 0.25-inch Dens Deck CR-20 BP-AA or SBS-
AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-240.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 50 of 57
TABLE 6B: GYPSUM DECKS – REROOF (TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 14) MDP
(psf) Type Fasteners Attach Type Attach Type Attach Base Ply Cap
HYBRID SYSTEMS:
G-16.
Existing sound
gypsum or
gypsum plank
Glasbase; Flexiglas
Base; Flintlastic
Base 20; All
Weather / Empire
Base; Yosemite
Trufast Twin
Loc-Nail
Assembled
Fastener
(min. 1.8”)
7-inch o.c. at the 4-
inch lap and 7-inch
o.c. in two (2),
equally spaced,
staggered center
rows
Min. 1.5-inch
ACFoam II,
FlintBoard ISO,
ENRGY 3 or Multi-
Max FA3
HA None N/A SBS-SA-
H
(Optional)
SBS-AA,
SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-60.0
CONVENTIONAL SYSTEMS:
G-17.
Existing sound
gypsum or
gypsum plank
All Weather /
Empire Base;
Yosemite
Trufast FM-75
or FM-90
Base Sheet
Fastener
9-inch o.c. at the 4-
inch lap and 18-inch
o.c. in two (2),
equally spaced,
staggered center
rows
(Optional) Min. 1.5-
inch ACFoam II,
FlintBoard ISO,
ENRGY 3 or Multi-
Max FA3
HA
Min. 0.75-inch
FescoBoard
(homogeneous) or min.
0.5-inch Structodek
High Density Fiberboard
HA BP-AA or
SBS-AA
(Optional)
BP-AA or
SBS-AA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
G-18.
Existing sound
gypsum or
gypsum plank
Glasbase; Flexiglas
Base; Flintlastic
Base 20; All
Weather / Empire
Base; Yosemite
Trufast Twin
Loc-Nail
Assembled
Fastener
(min. 1.8”)
7-inch o.c. at the 4-
inch lap and 7-inch
o.c. in two (2),
equally spaced,
staggered center
rows
Min. 1.5-inch
ACFoam II,
FlintBoard ISO,
ENRGY 3 or Multi-
Max FA3
HA
Min. 0.75-inch
FescoBoard
(homogeneous) or min.
0.5-inch Structodek
High Density Fiberboard
HA BP-AA or
SBS-AA
(Optional)
BP-AA or
SBS-AA
SBS-AA,
SBS-TA or
APP-TA
-60.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 51 of 57
TABLE 6C: GYPSUM DECKS – REROOF (TEAR-OFF)
SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1) Base Insulation Layer(s) Top Insulation Layer Roof Cover (Note 14) MDP (psf) Type Fasteners Attach Base Ply Cap
G-19.
Existing sound
gypsum or
gypsum plank
(Optional) One or more
layers, any combination,
loose laid
Min. 0.5-inch Structodek
High Density Fiberboard
Roof Insulation
OMG Polymer GypTec with 3”
GypTec Plate 1 per 2 ft2 BP-AA or SBS-
AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
G-20.
Existing sound
gypsum or
gypsum plank
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch Dens Deck or
Dens Deck Prime
OMG Polymer GypTec with 3”
GypTec Plate 1 per 1.78 ft2
BP-AA, SBS-
AA, SBS-TA or
APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
G-21.
Existing sound
gypsum or
gypsum plank
(Optional) One or more
layers, any combination,
loose laid
Min. 0.5-inch Structodek
High Density Fiberboard
Roof Insulation
Trufast Twin Loc-Nail Assembled
Fasteners (minimum 1-inch
embedment into deck)
1 per 2 ft2 BP-AA or SBS-
AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
G-22.
Existing sound
gypsum or
gypsum plank
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch Dens Deck or
Dens Deck Prime or
SECUROCK Gypsum-Fiber
Roof Board
Trufast Twin Loc-Nail Assembled
Fasteners (minimum 1-inch
embedment into deck)
1 per 2 ft2
BP-AA, SBS-
AA, SBS-TA or
APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
TABLE 6D: GYPSUM DECKS – REROOF (TEAR-OFF)
SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Sheet Roof Cover (Note 14) MDP
(psf) Base Fasteners Attach Ply Cap
SELF-ADHERING SYSTEMS:
G-23. Existing sound gypsum
or gypsum plank Flintlastic SA NailBase
Trufast Twin Loc-Nail
Assembled Fastener
(min. 1.8”)
9-inch o.c. at the 4-inch lap and 9-inch o.c. in two (2),
equally spaced, staggered center rows SBS-SA SBS-SA -60.0
CONVENTIONAL SYSTEMS:
G-24. Existing sound gypsum
or gypsum plank
All Weather / Empire Base;
Yosemite
Trufast FM-75 or FM-90
Base Sheet Fastener
9-inch o.c. at the 4-inch lap and 18-inch o.c. in two (2),
equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA -45.0*
G-25. Existing sound gypsum
or gypsum plank
Glasbase; Flexiglas Base; All
Weather / Empire Base; Yosemite Simplex Turbo Tube-Lok 9-inch o.c. at the 4-inch lap and 12-inch o.c. in two (2),
equally spaced, staggered center rows
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -45.0*
G-26. Existing sound gypsum
or gypsum plank
Glasbase; Flexiglas Base; Flintlastic
Base 20; All Weather / Empire
Base; Yosemite
Trufast Twin Loc-Nail
Assembled Fastener
(min. 1.8”)
9-inch o.c. at the 4-inch lap and 9-inch o.c. in two (2),
equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA, SBS-
TA or APP-TA -67.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 52 of 57
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No. Substrate (Notes 1 & 11) Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP
(psf) Type Attach Type Attach Base Ply Cap
SELF-ADHERING SYSTEMS:
R-1 Existing fully bonded BUR or
modified bitumen roof cover
Min. 0.25-inch Dens Deck primed
with FlintPrime or FlintPrime SA; or
SECUROCK Gypsum-Fiber Roof
Board.
HA None N/A SBS-SA (Optional) SBS-SA SBS-SA -105.0
R-2 Existing fully bonded BUR or
modified bitumen roof cover
Min. 1.5-inch ACFoam II, FlintBoard
ISO, ENRGY 3, H-Shield or Multi-Max
FA3
HA
Min. 0.25-inch Dens Deck primed
with FlintPrime or FlintPrime SA; or
SECUROCK Gypsum-Fiber Roof
Board.
HA SBS-SA (Optional) SBS-SA SBS-SA -105.0
R-3 Existing fully bonded, smooth
surface BUR or modified bitumen
Min. 0.25-inch Dens Deck primed
with FlintPrime or FlintPrime SA or
SECUROCK Gypsum-Fiber Roof
Board
A-PD, 6-
inch o.c. None N/A SBS-SA (Optional) SBS-SA SBS-SA -105.0
R-4 Existing fully bonded, mineral
surface modified bitumen
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board
A-PD, 6-
inch o.c. None N/A SBS-SA (Optional) SBS-SA SBS-SA -172.5
R-5 Existing fully bonded, mineral
surface modified bitumen
Min. 0.25-inch Dens Deck primed
with FlintPrime or FlintPrime SA
A-PD, 6-
inch o.c. None N/A SBS-SA (Optional) SBS-SA SBS-SA -180.0
R-6 Existing fully bonded, smooth
surface BUR or modified bitumen
Min. 1.5-inch ACFoam II, FlintBoard,
ENRGY 3 or Multi-Max FA3
A-PD, 6-
inch o.c.
Min. 0.25-inch Dens Deck primed
with FlintPrime or FlintPrime SA or
SECUROCK Gypsum-Fiber Roof
Board
A-PD, 6-
inch o.c. SBS-SA (Optional) SBS-SA SBS-SA -52.5
R-7 Existing fully bonded, mineral
surface BUR or modified bitumen
Min. 1.5-inch ACFoam II, FlintBoard,
ENRGY 3 or Multi-Max FA3
A-PD, 6-
inch o.c.
Min. 0.25-inch Dens Deck primed
with FlintPrime or FlintPrime SA or
SECUROCK Gypsum-Fiber Roof
Board
A-PD, 6-
inch o.c. SBS-SA (Optional) SBS-SA SBS-SA -172.5
R-8 Existing fully bonded BUR or
modified bitumen roof cover
Min. 1.5-inch ACFoam II, FlintBoard,
ENRGY 3 or H-Shield M-OSFA
Min. 0.25-inch Dens Deck primed
with FlintPrime or FlintPrime SA or
SECUROCK Gypsum-Fiber Roof
Board
M-OSFA SBS-SA (Optional) SBS-SA SBS-SA -157.5
R-9
Existing fully bonded, smooth- or
granule-surface BUR or modified
bitumen
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board M-PG1 None N/A SBS-SA (Optional) SBS-SA SBS-SA -172.5
R-10
Existing fully bonded, smooth- or
granule-surface BUR or modified
bitumen
Min. 0.25-inch Dens Deck primed
with FlintPrime or FlintPrime SA M-PG1 None N/A SBS-SA (Optional) SBS-SA SBS-SA -180.0
R-11 Existing fully bonded BUR or
modified bitumen roof cover
Min. 1.5-inch ACFoam II, FlintBoard,
ENRGY 3 or H-Shield M-PG1 Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board M-PG1 SBS-SA (Optional) SBS-SA SBS-SA -172.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 53 of 57
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No. Substrate (Notes 1 & 11) Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP
(psf) Type Attach Type Attach Base Ply Cap
R-12 Existing fully bonded BUR or
modified bitumen roof cover
Min. 1.5-inch ACFoam II, FlintBoard,
ENRGY 3 or Multi-Max FA M-PG1 Min. 0.25-inch Dens Deck primed
with FlintPrime or FlintPrime SA M-PG1 SBS-SA (Optional) SBS-SA SBS-SA -180.0
R-13
Existing fully bonded, smooth- or
granule-surface BUR or modified
bitumen
Min. 0.25-inch Dens Deck primed
with FlintPrime or FlintPrime SA or
SECUROCK Gypsum-Fiber Roof
Board
OB500 None N/A SBS-SA (Optional) SBS-SA SBS-SA -120.0
R-14 Existing fully bonded BUR or
modified bitumen roof cover
Min. 1.5-inch ACFoam II, FlintBoard
ISO or ENRGY 3 OB500
Min. 0.25-inch Dens Deck primed
with FlintPrime or FlintPrime SA or
SECUROCK Gypsum-Fiber Roof
Board
OB500 SBS-SA (Optional) SBS-SA SBS-SA -120.0
R-15
Existing fully bonded, smooth- or
granule-surface BUR or modified
bitumen
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board CR-20 None N/A SBS-SA (Optional) SBS-SA SBS-SA -172.5
R-16
Existing fully bonded, smooth- or
granule-surface BUR or modified
bitumen
Min. 0.25-inch Dens Deck primed
with FlintPrime or FlintPrime SA CR-20 None N/A SBS-SA (Optional) SBS-SA SBS-SA -192.5
R-17 Existing fully bonded BUR or
modified bitumen roof cover
Min. 1.0-inch ISO 95+ GL, H-Shield,
H-Shield CG, ENRGY 3 or min. 1.3-
inch ACFoam III, Min. 1.5-inch Multi-
Max FA3 or Ultra-Max
CR-20 Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board CR-20 SBS-SA (Optional) SBS-SA SBS-SA -172.5
R-18 Existing fully bonded BUR or
modified bitumen roof cover
Min. 1.0-inch ISO 95+ GL, H-Shield,
H-Shield CG, ENRGY 3 or min. 1.3-
inch ACFoam III, Min. 1.5-inch Multi-
Max FA3 or Ultra-Max
CR-20 Min. 0.25-inch Dens Deck primed
with FlintPrime or FlintPrime SA CR-20 SBS-SA (Optional) SBS-SA SBS-SA -192.5
HYBRID SYSTEMS:
R-19 Existing fully bonded BUR or
modified bitumen roof cover
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board HA None N/A SBS-SA-H (Optional) SBS-AA,
SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA -105.0
R-20 Existing fully bonded, smooth
surface BUR or modified bitumen
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board
A-PD, 6-
inch o.c. None N/A SBS-SA-H (Optional) SBS-AA,
SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA -105.0
R-21 Existing fully bonded, mineral
surface modified bitumen
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board
A-PD, 6-
inch o.c. None N/A SBS-SA-H (Optional) SBS-AA,
SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA -180.0
R-22
Existing fully bonded, smooth- or
granule-surface BUR or modified
bitumen
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board M-PG1 None N/A SBS-SA-H (Optional) SBS-AA,
SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA -180.0
R-23
Existing fully bonded, smooth- or
granule-surface BUR or modified
bitumen
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board OB500 None N/A SBS-SA-H (Optional) SBS-AA,
SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA -120.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 54 of 57
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No. Substrate (Notes 1 & 11) Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP
(psf) Type Attach Type Attach Base Ply Cap
R-24
Existing fully bonded, smooth- or
granule-surface BUR or modified
bitumen
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board CR-20 None N/A SBS-SA-H (Optional) SBS-AA,
SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA -195.0
CONVENTIONAL SYSTEMS:
R-25 Existing fully bonded BUR or
modified bitumen roof cover
0.5-inch Structodek High Density
Fiberboard or min. 0.75-inch Fesco
Board (homogeneous)
HA None N/A BP-AA, SBS-
AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -105.0
R-26 Existing fully bonded BUR or
modified bitumen roof cover
0.25-inch Dens Deck, Dens Deck
Prime or SECUROCK Gypsum-Fiber
Roof Board
HA None N/A
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -105.0
R-27 Existing fully bonded BUR or
modified bitumen roof cover
Min. 1.5-inch ACFoam II, FlintBoard
ISO, ENRGY 3, H-Shield or Multi-Max
FA3
HA
Min. 0.5-inch Structodek High
Density Fiberboard, Min. 0.75-inch
FescoBoard (homogeneous) or Min.
0.5-inch DuraBoard (homogeneous)
HA BP-AA or
SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -105.0
R-28 Existing fully bonded BUR or
modified bitumen roof cover
Min. 1.5-inch ACFoam II, FlintBoard
ISO, ENRGY 3, H-Shield or Multi-Max
FA3
HA
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board, Dens Deck, Dens
Deck Prime
HA
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -105.0
R-29 Existing fully bonded, smooth
surface BUR or modified bitumen
Min. 0.5-inch Structodek High
Density Fiberboard
A-PD, 6-
inch o.c. None N/A BP-AA, SBS-
AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -105.0
R-30 Existing fully bonded, mineral
surface modified bitumen
Min. 0.5-inch Structodek High
Density Fiberboard
A-PD, 6-
inch o.c. None N/A BP-AA, SBS-
AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -180.0
R-31 Existing fully bonded, smooth
surface BUR or modified bitumen
Min. 0.25-inch Dens Deck, Dens
Deck Prime or SECUROCK Gypsum-
Fiber Roof Board
A-PD, 6-
inch o.c. None N/A
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -105.0
R-32 Existing fully bonded, mineral
surface modified bitumen
Min. 0.25-inch Dens Deck, Dens
Deck Prime or SECUROCK Gypsum-
Fiber Roof Board
A-PD, 6-
inch o.c. None N/A
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -180.0
R-33 Existing fully bonded, smooth
surface BUR or modified bitumen
Min. 1.5-inch ACFoam II, FlintBoard
ISO, ENRGY 3 or H-Shield
A-PD, 6-
inch o.c.
Min. 0.5-inch Structodek High
Density Fiberboard
A-PD, 6-
inch o.c.
BP-AA or
SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -52.5
R-34 Existing fully bonded, smooth
surface BUR or modified bitumen
Min. 2-inch ACFoam II, FlintBoard
ISO, ENRGY 3 or H-Shield
A-PD, 6-
inch o.c.
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board or Dens Deck
A-PD, 6-
inch o.c.
BP-AA or
SBS-AA,
SBS-TA or
APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -52.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 55 of 57
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No. Substrate (Notes 1 & 11) Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP
(psf) Type Attach Type Attach Base Ply Cap
R-35 Existing fully bonded, mineral
surface BUR or modified bitumen
Min. 1.5-inch ACFoam II, FlintBoard
ISO, ENRGY 3 or H-Shield
A-PD, 6-
inch o.c.
Min. 0.5-inch Structodek High
Density Fiberboard
A-PD, 6-
inch o.c.
BP-AA or
SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -172.5
R-36 Existing fully bonded, mineral
surface BUR or modified bitumen
Min. 2-inch ACFoam II, FlintBoard
ISO, ENRGY 3 or H-Shield
A-PD, 6-
inch o.c.
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board or Dens Deck
A-PD, 6-
inch o.c.
BP-AA or
SBS-AA,
SBS-TA or
APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -172.5
R-37 Existing fully bonded BUR or
modified bitumen roof cover
Min. 1.5-inch ACFoam II, FlintBoard
ISO, ENRGY 3 or H-Shield M-OSFA Min. 0.5-inch Structodek High
Density Fiberboard M-OSFA BP-AA or
SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -127.5
R-38 Existing fully bonded BUR or
modified bitumen roof cover
Min. 1.5-inch ACFoam II, FlintBoard
ISO, ENRGY 3 or H-Shield M-OSFA Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board or Dens Deck M-OSFA
BP-AA or
SBS-AA,
SBS-TA or
APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -157.5
R-39
Existing fully bonded, smooth- or
granule-surface BUR or modified
bitumen
Min. 0.5-inch Structodek High
Density Fiberboard M-PG1 None N/A BP-AA, SBS-
AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -180.0
R-40
Existing fully bonded, smooth- or
granule-surface BUR or modified
bitumen
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof
Board
M-PG1 None N/A
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -180.0
R-41 Existing fully bonded BUR or
modified bitumen roof cover
Min. 1.5-inch ACFoam II, FlintBoard
ISO, ENRGY 3 or H-Shield M-PG1 Min. 0.5-inch Structodek High
Density Fiberboard M-PG1 BP-AA or
SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -180.0
R-42 Existing fully bonded BUR or
modified bitumen roof cover
Min. 1.5-inch ACFoam II, FlintBoard
ISO, ENRGY 3 or H-Shield M-PG1 Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board or Dens Deck M-PG1
BP-AA or
SBS-AA,
SBS-TA or
APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -180.0
R-43
Existing fully bonded, smooth- or
granule-surface BUR or modified
bitumen
Min. 0.5-inch Structodek High
Density Fiberboard OB500 None N/A BP-AA, SBS-
AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -120.0
R-44
Existing fully bonded, smooth- or
granule-surface BUR or modified
bitumen
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board OB500 None N/A
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -120.0
R-45 Existing fully bonded BUR or
modified bitumen roof cover
Min. 1.5-inch ACFoam II, FlintBoard
ISO, ENRGY 3 or H-Shield OB500 Min. 0.5-inch Structodek High
Density Fiberboard OB500 BP-AA or
SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -120.0
R-46 Existing fully bonded BUR or
modified bitumen roof cover
Min. 1.5-inch ACFoam II, FlintBoard
ISO, ENRGY 3 or H-Shield OB500
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board, Dens Deck or Dens
Deck Prime
OB500
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -120.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 56 of 57
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No. Substrate (Notes 1 & 11) Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP
(psf) Type Attach Type Attach Base Ply Cap
R-47
Existing fully bonded, smooth- or
granule-surface BUR or modified
bitumen
Min. 0.5-inch Structodek High
Density Fiberboard CR-20 None N/A BP-AA, SBS-
AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -195.0
R-48
Existing fully bonded, smooth- or
granule-surface BUR or modified
bitumen
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board CR-20 None N/A
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -195.0
R-49 Existing fully bonded BUR or
modified bitumen roof cover
Min. 1.0-inch ISO 95+ GL, H-Shield,
H-Shield CG, ENRGY 3 or min. 1.3-
inch ACFoam III, Min. 1.5-inch Multi-
Max FA3 or Ultra-Max
CR-20 Min. 0.25-inch Dens Deck or Dens
Deck Prime CR-20 SBS-TA (Optional) SBS-TA SBS-TA -180.0
R-50 Existing fully bonded BUR or
modified bitumen roof cover
Min. 1.0-inch ISO 95+ GL, H-Shield,
H-Shield CG, ENRGY 3 or min. 1.3-
inch ACFoam III, Min. 1.5-inch Multi-
Max FA3 or Ultra-Max
CR-20
Min. 0.5-inch Structodek High
Density Fiberboard or DuraBoard
(homogeneous) or min. 1.5-inch
FescoBoard (laminated)
CR-20 BP-AA or
SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -180.0
R-51 Existing fully bonded BUR or
modified bitumen roof cover
Min. 1.0-inch ISO 95+ GL, H-Shield,
H-Shield CG, ENRGY 3 or min. 1.3-
inch ACFoam III, Min. 1.5-inch Multi-
Max FA3 or Ultra-Max
CR-20 Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board CR-20 BP-AA or
SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -225.0
R-52 Existing fully bonded BUR or
modified bitumen roof cover
Min. 1.0-inch ISO 95+ GL, H-Shield,
H-Shield CG, ENRGY 3 or min. 1.3-
inch ACFoam III, Min. 1.5-inch Multi-
Max FA3 or Ultra-Max
CR-20 Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board CR-20 SBS-TA or
APP-TA
(Optional) SBS-TA
or APP-TA
SBS-TA or
APP-TA -232.5
R-53 Existing fully bonded BUR or
modified bitumen roof cover
Min. 1.0-inch ISO 95+ GL, H-Shield,
H-Shield CG, ENRGY 3 or min. 1.3-
inch ACFoam III, Min. 1.5-inch Multi-
Max FA3 or Ultra-Max
CR-20 Min. 0.25-inch Dens Deck CR-20 BP-AA or
SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -240.0
COLD-APPLIED SYSTEMS:
R-54 Existing fully bonded BUR or
modified bitumen roof cover
(Optional) Min. 0.5-inch ACFoam II,
FlintBoard ISO, H-Shield, FlintBoard
ISOH
OB500
Min. 1.5-inch ACFoam III, FlintBoard
Iso Cold, H-Shield CG or FlintBoard
Iso ColdH
OB500 SBS-CA1 None SBS-CA1 -82.5
R-55 Existing fully bonded BUR or
modified bitumen roof cover
(Optional) Min. 0.5-inch ACFoam II,
FlintBoard ISO, H-Shield, FlintBoard
ISOH
CR-20
Min. 1.5-inch ACFoam III, FlintBoard
Iso Cold, H-Shield CG or FlintBoard
Iso ColdH
CR-20 SBS-CA1 None SBS-CA1 -82.5
R-56
Existing fully bonded, smooth- or
granule-surface BUR or modified
bitumen
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board
A-PD, 6-
inch o.c. None N/A SBS-CA1 None SBS-CA1 -105.0
R-57 Existing fully bonded, smooth
surface BUR or modified bitumen
Min. 0.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOH
A-PD, 6-
inch o.c.
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board
A-PD, 6-
inch o.c. SBS-CA1 None SBS-CA1 -52.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R21 for FL2533-R20
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 06/20/2018
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 57 of 57
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No. Substrate (Notes 1 & 11) Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP
(psf) Type Attach Type Attach Base Ply Cap
R-58 Existing fully bonded, mineral
surface BUR or modified bitumen
Min. 0.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOH
A-PD, 6-
inch o.c.
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board
A-PD, 6-
inch o.c. SBS-CA1 None SBS-CA1 -105.0
R-59
Existing fully bonded, smooth- or
granule-surface BUR or modified
bitumen
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board M-PG1 None N/A SBS-CA1 None SBS-CA1 -105.0
R-60 Existing fully bonded, mineral
surface BUR or modified bitumen
Min. 0.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOH
M-OSFA,
M-PG1
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board
M-OSFA,
M-PG1 SBS-CA1 None SBS-CA1 -105.0
R-61
Existing fully bonded, smooth- or
granule-surface BUR or modified
bitumen
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board OB500 None N/A SBS-CA1 None SBS-CA1 -105.0
R-62 Existing fully bonded, mineral
surface BUR or modified bitumen
Min. 0.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOH OB500 Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -105.0
R-63
Existing fully bonded, smooth- or
granule-surface BUR or modified
bitumen
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board CR-20 None N/A SBS-CA1 None SBS-CA1 -105.0
R-64 Existing fully bonded, mineral
surface BUR or modified bitumen
Min. 0.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOH CR-20 Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board CR-20 SBS-CA1 None SBS-CA1 -105.0
TABLE 7B: RECOVER APPLICATIONS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER
System
No.
Substrate
(Notes 1 & 11) Primer Roof Cover (Note 14) MDP (psf) Base Ply Cap
R-65 Existing fully bonded BUR over structural concrete deck (Optional) FlintPrime (ASTM D41) SBS-CA1 None SBS-CA1 -187.5