PERMIT APPLICATION FOR:,Sw#w --imypao✓4 W , ndows
PROPOSED]M PROVEMENT LOCATION:
Address: 11091 S INDIAN RIVER DRIVE,FORT PIERCE,FL 34982
Legal Description:
PropertyTak ID#:3532-503-0020-010-6 Lot No.
Site Plan Name: Block No.
Project Name:DERRICK BEANS
Setbacks ,Front Back: RlghtSide: Left Side:
DETAILED DESCRIPTION OF WORK:
Replacement Windows(4)
CONSTRUCTION INFORMATION:
Additional wor to De nertormedunder this permit—check all appy,
HVAC Gas Tank ❑Gas Piping _Shutters �Uindows/Doors
ElElectric O Plumbing ❑Sprinklers Generator ID Roof
Total Sq.Ft of Construction: S .Ft.of First Floor:
Cost of Construction:$ 8,300 Utllities:11Sewer[:]Septic Building Height:
r
OWNER/LESSEE; CONTRACTOR:
Name DERRICK BEANS Name:Sam Ochstein
Address: 11091 S INDIAN RIVER DRIVE Company:Newsouth Window Solutions
City: FORT PIERCE State: FL Address:2526 Okeechobee Blvd.
Zip Code: 34982 Fax: City:West Palm Beach State:FL
Phone No. Zip Code: 33409 Fax:561-478-4100
E-Mail: Phone No. 561-712-9000
Fill In fee simple Title Holder on next page(If different E-Mail:.lenniferaviles(a,newsouthwindow.com
from the Owner listed above) State or County License:CRC1330822
If value of construction Is$2900 or more,a RECORDED Notice of Commencement Is required.
I
I
i
�SUPPLEMENTALCONSTRUCTION L,IEN�LAW INFORMATION` ` h
,.
DESIGNER/ENGINEER: _Not Applic MORTGAGE COMPANY: _Not Appli e�
Name:
Name:
l Address: Address:
City: State: City: State:
Zip: Phone: Zip: Phone:
FEE SIMPLE TITLE HOLDER: _Not Ap BONDING COMPANY: Not A
Name: Name:
Address: Address:
City: City:
Zip: Phone: Zip: Phone:
I certify that no work or installation has commenced priorto the issuance of a permit.
St.Lucie Counri makes no representation that is granting a�ermit will authorize the permit holder to build the subject structure
which 15 in on lict with any applicable Home Owners Assoc pa rules,bylaws or and covenants that may restrict or prohibit such
structure.Please consult with your Home Owners Association and review your deed for any restrictions which may apply.
In consideration of the granting of this requested permit,I do hereby agree that I will,in all respects,perform the work
In accordance with the approved plans,the Florida Building Codes and St.Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review:room additions,
accessory structures,swimming pools,fences,walls,signs,screen rooms and accessory uses to another non-residential use
WARNING TO OWNER:Your failure to Record a Notice of Commencement may result in your paying twice for
improvements to your property.A Notice of Commencement must be recorded and posted on the jobsite
before the first inspection. If you intend to obtain financing,consult with lender or an attorney before
commencing work or rdin our Notice of Commencement.
Sign ofwnler/A/ge essee Signature of Contlra or/License Holder
STATE OF F
STATE OF
OUNTY OFA F'g 1/►�N �1P01 _� COUNTY OF O l"G
rv� (?peach
The fo oing instrument was acknowledged before me The forgoing instrument was acknowledged before me
this day of Hct r Ch . 20 I—by this c 'diy of Ma r h 20 q by
Oe rr 1`n If, gea^_T_ fV. n qhs ,n
(Name of person acknowledging) (Name of person acknowledging}
(Signature of Notary Public-State of Flor a) (Signature df Notary Public-State of Florida}
Personally Known OR Produced Identification V Personally Known OR Produced Identification
Type of Identification Produced 0(–+Vers Uc ense Type of Identification Produced
Commission No. ' 3
Commission No.64 1 1 11
JENNI ER AVILES ��PYp�,�� p ILiP G. PEROT
a`�" s��y State of Florida-Notary Public ;?o�" a��:state of Florida Notary P Ic
.tCom
mis =•
il 4# G 166
M Commission Expires o= My Commission Expire
Revised 07/15/ rF.°�� y 2022 %SOF December 10, 2021
nna�• Merch 15, ��unn•
mom
REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE
COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW
DATE
COMPLETE
=INITIALS
I
� G� 't,. 1lt �;, � �,,,�
„�'�b`3 tiny., .�� ��a
NewSouth 2526 Okeechobee Blvd.•West Palm Beach,FL 33409-4006
WINDOW LtmONS561-712-9000.561-478-4100 fax
-
wwwNewSouthWindow.com Lic#CRC-1330822
Malls,in Florida for Florida omes Date
To Ie, a N S E-mail besu S . r�{�
0 l i / • ,�-rr�/ g:O.L �& Home Phones 1_3 Cell Phone
city�lI
T r C r State _ zip D�W Business(Mr./Mrs.)
Replacement Windows•Entry&Patio Doors•Storm Doors•Impact Resistant Windows&Doors
WHOLESALE&RETAIL WINDOW CONTRACT
NewSouth Window Solutions agrees to measure,manufacture or furnish and service the following custom made windows for the amount STIPULATED BELOW-
All NewSouth Vantage Series Windows include Double Pane,Low-E glass with Argon gas,and 12 point fusion welded corners.
All Vantage windows are sealed and vacuum tested for uperior argon retention.
Color oonons(whole window) Whke Oran ❑Bmnze(eatedor only) Wwist&CIs. Q1khIte Oran
I Colon may varysligh hom sample (Initial)
Is F
LOW-E GLASS: ❑366 GLASS V34QGLASS OBSCURE GLASS 13 YES to ITEMPERED GLA55 OYES O
ALL SASHES ARE ARGON FILLERTAWIfHOUT EXTRA CHARGE LOCATION: LOCATION:
""ms ter ❑ Tantage ❑�Tantage9000 Single Hung gyantage 9000 Impact ❑other:
GWDSTYLE
OW` A n DOUBLE HUNG E-VANTAGE Ll PATIO PATIO DOORS
(HALF-SCREEN STANDARD)OFull Screen ❑impact 13 non-impact O Open Praire Grids
SINGLE HUNG ARCH OR ❑
❑ 9D00 SINGLE HUNG(HALF-SCREEN) 0 5/0 6/8 O 9/0 X 6/8
impact nonimpact ofslicieoutsiderlookl g In(aw arrows OSU)eNon x
O O
❑5/0 x 8/0 119/0 X 8/0
2 LITE SLIDER E-VANTAGE ❑ 0 6/0 X 6/8 0 12/0 X 6/8
(XX,HALF-SCREEN STANDARD)O Full Screen 0 6/0 X 8/0 0 12/0 X 8/0
s 9 0SLIDER OOX:: XO - 0 8/0X6/8 0 16/0X6/8
outside looking in impact O non-imps ❑8/0 X 8/0 ❑16/0 X 8/0
PICTURE WINDOW VANTAGE
(NO SCREEN)
O impact O non-Impact 3 PANEL PATIO DOORS
O Impact O non-impact
3 LITE SLIDER WITH PICTURE
WINDOW(2 SCREENS) Indicate size,draw avows for direction of slide
outside looking In
O Impact O non-impact
1/4-1/2-1/4 configuration
4 PANEL PATIO DOORS
IIIIIIII�IIIIIIII Y AWNING&HOPPER O impact O nonimpact
a 0 CASEMENT(OSD) =111GHT NNE
BIGM NINGE Indlute In arlOWS for direction of slide
S DOUBLE CASEMENT outside looking In
O Impact O non-impact
0 HALF 0 EYEBROW 0 QUARTER-ROUND 0 TRAP 0 OTHER
ROUND (DRAW IN SPACE)
GRIDSTYLES 0 STANDARD 0 CONTOUR 0 BRASS/GOLD/PENCIL Was this home built prior to 1978
t' 0
If yes,the undersigned ogress to thete dconditlom of the
0 Colonial 0 Prairie 0 Open Prairie NewSouth Lead Safe""'
Practices Adden m.ifhousetestspostive
to
rlead,anaddition per window will be added to the balance
I
I
I -
B ig afore
TOTAL NUMBER OF WINDOWS ON THIS ORDER: TOTAL DOORS: V Subject to NewSouth field engineering and approval.
f ARo v
i
❑Customer agrees to allow NewSouth to display a yard sign until 30 days after completion. TWOYEARS FREE IN NOME SERVICE
BUYER'S RIGHT TO CANCEL Total price* C�' $
BUYER MAY CANCELTHIS CONTRACT BY DELIVERING WRITTEN NOTICE O e
E30 0
TO THE SELLER AT ANY TIME PRIOR TO MIDNIGHT OF THE THIRD Down payment. 45.7 ij$
BUSINESS DAY AFTER THE DATE OF THIS TRANSACTION.BUYER MAY Delivery/commencement. $
USE THIS CONTRACT AS THAT NOTICE BY WRITING"1 HEREBY CANCEL" Balance due upon final $
AT THE BOTTOM AND ADDING BUYER'S NAME AND ADDRESS.THE window/door installation.
NOTICE MUST BE DELIVERED TO THE SELLER ATTHE ADDRESS SHOWN
ABOVE. Bank Financing❑Cash on Completion
All material is guaranteed to be as specified.All work is to be completed in a workmanlike manner according to standards and practices.This contract is
valid only with proper signatures.NewSouth shall not be held responsible for time and material delays,strikes,acts of God or any other matters beyond
its contioI. NewSouth is not responsible for any pre-existing structural conditions. No other work to be done, all other work to be excluded. Owner
agrees that the equity in this property is security for this contract.Since this contract calls for made to order goods, it is not subject to cancellation
except las stated above. Start installation approximately 12f[F weeks from above date. Verbal promises can cause misunderstandings, therefore
this contract constitutes the entire understanding of the parties, and no other understanding,collateral, verbal or otherwise,shall be binding, unless
signed by boI4,pVies. NewSouth to remove and haul away all job related debris.'*All 7 and discounts allotted. All charges included above.
Thank you yo or
x �ti X
Buyer's Sign 26"uth R es Ive
x x
Buyer's Signature NewSouth Manufacturing Authorized Officer
I
ewCz outh
WIN DOW SOLUTIONS
2526 Okeechobee Blvd,West Palm Beach,FL 33409•561-712-9000•CRC 13308U
Property Information Building Information
Owner: DERRICK BEANS Wind Zone: 170 MPH.
Address: 11091 S INDIAN RIVER DRIVE Exposure Category: C
FORT PIERCE,FL 34982 Minimum Building Dimension: 25 ft.
Mean Roof Height: 15 ft.
Risk Category: II
I
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
1 Int 60 59.75 7 35.6 -38.8
2 Int 60 59.75 7 35.6 -38.8
3 Int 60 59.75 7 35.6 -38.8
4 Int 60 59.75 7 35.6 -38.8
Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code.
Page 1 of 1
Opening I Size
(WxH)
1. HORIZONTAL SLIDER 60 x 59 ala
(DININGROOM)
2. HORIZONTAL SLIDER 60 x 59 3/4
3. HORIZONTAL SLIDER 60 x 59 3/4
4. HORIZONTAL SLIDER 60 x 59 3/4 = 12'
y� Z U
0
3 2
0
1 �O g
4 in �
coZ
I/� 3
a
O
NN
N
W
> N
EE 00
Z
QW M
W > LL
m
Y Zo
V ¢ �
W
za
G c �
o �
COPYIigM E•TEYPEBT.COY
SCALE:
NOT TO SCALE
DATE•
Mar 14,2019
PAGE OESCNIP "*
Site Plan
PAGE:
4-1
1/4/2019 Florida Building Code Online
1 w
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map Links Search
^, fur)Product Approval
��- -USER:Public User
db'
�ry Product ADnr2Xai Menu>Product or Aaollcahon Search>Application List
l �%fI la.7 I
Search Criteria Refine Search
Code Version 2017 FL# 16842.6
Application Type ALL Product Manufacturer ALL
Category ALL Subcategory ALL
Application Status ALL Compliance Method ALL
Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL
Product Model,Number or Name ALL Product Description ALL
Approved for use In HVHZ ALL Approved for use outside HVHZ ALL
Impact Resistant ALL Design Pressure ALL
Other ALL
Search Results-A plications
Type Manufacturer Validated Status
An
FL16842- Revision NewSouth Window Solutions — i Ryan J.King, Approved
R44 FL#: FL16842.6 P.E.
istory Model:f.Series 9000 Model 9550 Slider XO-Impact Rated-HVHZ (813)767-
Description:Extruded Vinyl"Impact"Horizontal Sliding Window with Flange 6555
Installation(XO or OX configurations)
Category:Windows
Subcategory:Horizontal Slider
LL L
"Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
Contact ::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850.487-1824
The State of Florida is an AA/EEO employer.ggpylight 2007-2013 State of Florida.::Privacy Statement::Accessibility,Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455,275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emaiis
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please click here,
Product Approval Accepts:
err ECtecE .®-n
Credit Card
Safe
https://www.floridabuilding.org/pr/pr_app_Ist.aspx 1/1
1/4/2019 Florida Building Code Online
kRT
, ,�.
BCIS Home Log Ing' User Registration Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map Links Search
bp0
aProduct Approval
USER:Public User
ProduR Anoroval Menu>Product or Aoolication Search>ep-plication List>Application Detail
I
FL# FL16642-R4
i Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer NewSouth Window Solutions
Address/Phone/Email 4901 oak fair blvd
tampa,FL 33610
(513)284-0129
danochstein@newsouthwindow.com
Authorized Signature Vivian Wright
rickw@rwbldgconsultants.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Windows
Subcategory Horizontal Slider
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Lyndon F Schmidt,P.E.
Evaluation Report
Florida License PE-43409
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2019
Validated By Ryan J.King,P.E.
Validation Checklist-Hardcopy Received
Certificate of Independence FL16842 R4 COI (c)Certificate of Indeoendence.odf
Referenced Standard and Year(of Standard) Standard year
AAMA/WDMA/CSA101/1.S.2/A440 2008
AAMA/WDMA/CSA101/I.S.2/A440 2005
AAMA/WDMA/CSA101/I.S.2/A440 2011
ASTM E1886 2005
ASTM E1996 2006
ASTM E1996 2005
ASTM E1996 2009
TAS 201,202, 203 1994
Equivalence of Product Standards
Certified By
https://www.floridabuilding.org/pr/pr app dU.aspx?param=wGEVXQwtDgtmmTSTNdVPsf%2fLKgxApZZOumXyGur83s42hZkY3sC4ZA%3d%3d 1/5
1/4/2019 Florida Building Code Online
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 04/11/2017
Date Validated 10/20/2017
Date Pending FBC Approval 10/23/2017
Date Approved 12/12/2017
Summary of Products
Go to Page 0 ® Page 1/20 0
------- --- —---- — ----------------------------------
FL# Model,Number or Name Description
16842.1 a.Series 9000 Model 9500 Slider XO Extruded Vinyl"Non-Impact"Horizontal Sliding Window
utilizing a Nail Fin Installation(XO or OX configurations)
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL16842 R4 II (b)Inst 16842.1.od
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16842.1 for Design Pressure Ratings,any FL16842 R4 AE (b)Eval 16842.1.pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
16842.2 b.Series 9000 Model 9500 Slider XO Extruded Vinyl"Non-Impact"Horizontal Sliding Window with
Flange Installation(XO or OX configurations)
Limits of Use Installation Instructions _
Approved for use In HVHZ: No FL16842 R4 ]I (k)Inst 16842.2.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16842.2 for Design Pressure Ratings,any FL16842 R4 AE (b)Eval 16842.2.pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
16842.3 c.Series 9000 Model 9550 Slider XO Extruded Vinyl"Impact"Horizontal Sliding Window utilizing a
-Impact Rated Nall Fin Installation(XO or OX configurations)
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL16842 R4 II (12)Inst 16842.3.1df
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16842.3 for Design Pressure Ratings,any FL16842 R4 AE (b)Eval 16842.3.pdf
additional use limitations,Installation Instructions and product Created by Independent Third Party:Yes
particulars.
16842.4 d.Series 9000 Model 9550 Slider XO Extruded Vinyl"Impact"Horizontal Sliding Window with Flange
-Impact Rated Installation(XO or OX configurations)
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL16842 R4 11 (b)Inst 16842.4.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16842.4 for Design Pressure Ratings,any FL16842 R4 AE (b)Eval 1¢842.4.pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
16842.5 e.Series 9000 Model 9550 Slider XO Extruded Vinyl"Impact"Horizontal Sliding Window utilizing a
- - -Impact Rated-HVHZ Nail Fin Installation(XO or OX configurations) --- —
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL16842 R4 II ()a)Inst 16842.5.01(
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 16842.5 for Design Pressure Ratings,any F1,16842 R4 AE (b)Eval 16842.5.pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
nge
16842.6— f.Series 9000 Model 9550 Slider XO Extruded Vinyl"Impact"Horizontal Sliding Window with Fla
Impact Rated-HVHZ Installation(XO or OX configurations)
httpsJ/www.floridabuilding.org/pr/pr_app_otl.aspx?param=wGEVXQwtDgtmmTSTNdVPsf%2fLKgxApZZQumXyGur83s42hZkY3sC4ZA%3d%3d 2/5
1/4/2019 Florida Building Code Online
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL16842 R4 II (j)(nst 16842.6 &
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 16842.6 for Design Pressure Ratings,any FL16842 R4 AE (0)Eval 16842.6.12df
additional use limitations,installation Instructions and product Created by Independent Third Party:Yes
particulars.
16842:7 g.Series 9000 Model 9500-3 Slider Extruded Vinyl"Non-Impact"Horizontal Sliding Window
XOX utilizing a Nall Fin Installation(XOX,configuration)
Limits of Use - Installation Instructions
Approved for use In HVHZ:No FL16842 R4 II (p)Inst 16842.7.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16842.7 for Design Pressure Ratings,any FL16842 R4 AE (b)Eval66842.7.pdf
additional use limitations,Installation instructions and product Created by Independent Third Party:Yes
particulars.
16842.8 — h.Series 9000 Model 9500-3 Slider Extruded Vinyl"Non-Impact"Horizontal Sliding Window with
�XOX Flange Installation(XOX,configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL16842 R4 II (j)Inst 16842.8.pff
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16842.8 for Design Pressure Ratings,any FL16842 R4 AE (§)Eval66842.8.pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
16842.9 1.Series 9000 Model 9550-3 Slider Extruded Vinyl"Impact"Horizontal Sliding Window utilizing a
XOX-Impact Rated Nail Fin Installation(XOX,configuration)
Limits of Use Installation Instructions
Approved for use In HVHZ:No FL16842 R4 II (12) Inst 16842.9.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 16842.9 for Design Pressure Ratings,any FL16842 R4 AE (b)Eval 16842.9.pdf
additional use limitations,Installation instructions and product Created by Independent Third Party:Yes
particulars.
16842.10 J.Series 9000 Model 9550-3 Slider^ Extruded Vinyl"Impact"Horizontal Sliding Window with Flange
XOX-Impact Rated Installation(XOX,configuration)
Limits of Use, Installation Instructions
-Approved for use in HVHZ:No FL16842 R4 II (b)Inst 16842.10.0Af
Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16842.10 for Design Pressure Ratings,any FL16842 R4 AE (b)Eva] 16842.10.pdf
additional use limitations,Installation instructions and product Created by Independent Third Party:Yes
particulars.
16842.11 k.Series 9000 Model 9550-3 Slider Extruded Vinyl"Impact"Horizontal Sliding Window utilizing a
XOX-Impact Rated-HVHZ Nail Fin Installation(XOX,configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL16842 R4 II (jz)Inst 16842.11.12df
Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16842.11 for Design Pressure Ratings,any FL16842 R4 AE (b)Eval 16842.11.odf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
16842.12 — I.Series 9000 Model 9500-3 Slider Extruded Vinyl"Impact"Horizontal Sliding Window with Flange
XOX-Impact Rated-HVHZ Installation(XOX,configuration)
Limits of Use Installation Instructions J
Approved for use in HVHZ:Yes FL36842 R4 II (jI)Inst 16842.12.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16842.12 for Design Pressure Ratings,any FL16842 R4 AE (b. Eval 16842,12, df
additional use limitations,Installation instructions and product Created by Independent Third Party:Yes
particulars.
16842.13 m.DuraGard Slider XX Extruded Vinyl"Non-Impact"Horizontal Sliding Window
utilizing a Nail Fin Installation(XX,configuration)
httpsl/www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgtmmTSTNdVPsf%2fLKgxApZZQumXyGur83s42hZkY3sC4ZA%3d%3d 3/6
1/4/2019 Florida Building Code Online
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL16842 R4 lI (b)Inst 1684
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16842.13 for Design Pressure Ratings,any FL16842 R4 AE (b)Eval 16842.13.pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
16842.14 — n.DuraGard Slider XX Extruded Vinyl"Non-Impact"Horizontal Sliding Window(XX,
configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL16842 R4 IT
(�Inst 16842.14.pd
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16842.14 for Design Pressure Ratings,any FL16842 R4 AE (b)Eval 16842.14.pdf
additional use limitations,Installation instructions and product Created by Independent Third Party:Yes
particulars.
16842.15 — o.DuraGard-3 Slider XOX Extruded Vinyl"Non-Impact"Horizontal Sliding Window
— utilizing a Nail Fin Installation(XOX,configuration)
Limits of Use — — Installation Instructions
Approved for use in HVHZ:No FL16842 R4 II (¢��nst 16642.15.p�[
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16842.15 for Design Pressure Ratings,any FL16642'R4 AE (b)Eval 16842.15.pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
16842.16 — p.DuraGard-3 Slider XOX Extruded Vinyl"Non-Impact"Horizontal Sliding Window with
Flange Installation(XOX,configuration)
Limits of Use Installation Instructions —
Approved for use In HVHZ:No FL16842 R4 II (¢)Inst 16842.16.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16842.16 for Design Pressure Ratings,any FL16842 R4 AE (b)Eval 16842.16.pd
additional use limitations,Installation Instructions and product Created by Independent Third Party:Yes
particulars.
16842.17 q.Sashlite Slider XX Extruded Vinyl"Non-Impact'Horizontal Sliding Window
utilizing a Nall Fin Installation(XX,configuration)
Limits of Use — Installation Instructions
Approved for use in HVHZ:No FL16842 R4 It (¢)Inst]6842.17.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16842.17 for Design Pressure Ratings,any FL16842 R4 AE (D)Eva[ 16842.17.pdf
additional use limitations,Installation instructions and product Created by Independent Third Party:Yes
particulars.
16842.18 — r.Sashlite Slider XX Extruded Vinyl"Non-Impact"Horizontal Sliding Window(XX,
configuration)
Limits of.Use Installation Instructions
Approved for use In HVHZ:No FL16842 R4 11 (b)Inst 16842.18.pd
Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16842.18 for Design Pressure Ratings,any FL16842 R4 AE (b)Eval 16842.18.pdf
additional use limitations,installation Instructions and product Created by Independent Third Party:Yes
particulars.
16842.19 — s.Sashlite-3 Slider XOX Extruded Vinyl"Non-Impact"Horizontal Sliding Window—
utilizing a Nail Fin Installation(XOX,configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL16842 R4 II (12)Inst 16842.19.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16842.19 for Design Pressure Ratings,any FL16842 R4 AE (¢)Eval 16842.19.pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
16842.20 t.Sashlite-3 Slider XOX Extruded Vinyl"Non-Impact"Horizontal Sliding Window(XOX,
configuration)
httpsl/www.floridabuilding.org/pr/pr_app dd.aspx7param=wGEVXQwtDgtmmTSTNdVPsf%2fLKgxApZZQumXyGur83s42hZkY3sC4ZA%3d%3d 4/5
1/4/2019 Florida Building Code Online
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL16842 R4 tI (12)Inst 16842.20.12df
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
other:See INST 16842.20 for Design Pressure Ratings,any FL16842 R4 AE (g)Eval 16842.20.adf
additional use limitations,installation Instructions and product Created by Independent Third Party:Yes
particulars.
Go to Page --- -- - -- - - Page 1/20 0
IWck N�,t
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1624
The State of Florida Is an APJEEO employer.Cypyrt_ght 2007-2013 State of Florida.::Privapi,Statement::Accessibility Statement::Refund statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.4Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine H you are a licensee under Chapter 455,F.S.,please click h2m.
Product Approval Accepts:
NV°°' ® e`C e:i
Credit Card
Safe
hnps://www.fioridabuilding.org/pr/pr_app_dU.aspx7param=wGEVXQWtDgtmmTSTNdVPsf°/`2fLKgxApZZQumXyGur83s42hZkY3SC4ZAa/o3d%3d 5/5
f {{{YYY n
]Newhuth
Z ;
WINDOWSOLUTIONs ��'•. r'j 0` 16"
m
4901 Oak F` a B d.,Tampa,FL 33610 Z
7S MAX.OVERALLAN
FlGE WIDTH y{
7,'MAX.OVERALL MME WODTH E° 9 •o
Series 9000 Model 9550 �— oz W
• ` '.a
mda�
T
SLIDER XO / / hl
IMPACT RATED - HVHZ
w/Flange
Z�
a GENERAL NOTES
W 1a
1. This product has been evaluated and is in compliance with the 6th Edifron(2017)Florida
Building Code(FBC)structural requIrements including the'High Velocity Hurricane Zone
(HVhu). O x
6 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to 'o I a
base material shag be beyond wall dressing or stucco. 0
3. When used in the 9iVHr this product complies with Section 1626 of the Florida Bulding Code / m
and does not require an Impact resistant covering. /
4. When used in ureas outside of the'HVHr requiring wind bome debris protection this product
complies with RBC Sections 1609.1214 R301.2.1.2 and does not require an impact resistant n S r
covering.This product meets mWe level'D-and includes Wind Zone 4 as defined in ASTM '^
w a
NO
El 996 and FBC Sections 1609.122 6 8301.2.12.1. ���� 0
5. For 2(stud fr mhV construction,anchortng of these units shag be the some as that shown for d
2x buck masonry construction. W
F
8 y
6. Site conditions that deviate from the detalls of this drawing require further engineering analysis W
s` by a licensed engineer or registered architect. 'c R _
7. This product meets water tn6ltmhDn requirements for"HVHr. N m-2-.!
N N�N--9--
�,
TABLE OF CONTENTS MAX MAX a a N rj
MAX RANGE
MAlGA ERALL DESIGNP1tESSlIRE o c
SHEETf DESCRIPTION DAYlIfE DAYUiE GLASS �^°'"z u
1 Typical elevations,design pressures&general notes RANGE FRAME DIMENSION DIMENSION TYPE RSf7 DAm 2119174
i
DIMENSION DIMENSION (OPERABLE)-. ..(RXED) POS. NEG. sr..r. N.T.S.
2 Vertical S horizontal aoss sections om�,, dK m
3 Vertical&horizontal cross sections 7a.a'X 64.fr 74.0-X baa' 33r X 57.81- )Sas X 56.56- G1,62 +55.0 -60.0
4 Buck 6 frame anchoring °"`•e" LFS i
5 Components °�NwO N0'
E Note:This product,when used with G1 glazing,Is not approved for use above 30 feet in the"HVHT. FL-16842.6 °
6 B of mate o an acing detalls °
sMar r a 6 p
0
a
NOIESheefMetdSaewsms>stperlelroteo ��,�'� •` �
TKmh.of 3Areodslhoughatkmd2dwobof
meld ImalntaTn a nin.318 edge dhtmioel, = # et
TC Nis
E 41111* itd
p X r. °s��
G1 GZ
� •
Z
3 17 SMN=3 s DIP
No
''eocr widofioac/ rs� 2 `3
2 Metal solerassembir booted rftrn 4 HORMONrAL SECTION G1
each end of Me bottom ld Sled raL Z MeCornlm n-
&MW W=ind to tmd wet
(6J!6><112'PPN SMS E 3 '
EXTUdOR INTERIOR Q
Ta/4•MRl � � ���
a A GZ GI 3
"�TC C • Z 15
•
INTERIOR
ERIOR B 1a •�wv
a 10 Gl GZ 13 o' 8
SffNOTEt 11 7 15 SEENM2
12 •' 1 1i >?
• GT GZ F
v
v • rS ;
• •
3 p M!
• r ` ..
it
•' r
• �"1N^Z O
b 1 D e a ° CAM 2/19/14 =
I-114'MNnE. N.T.S.
D1 2 EXTERIOR EMS.PWJ er A
E 3 VERKM 05S S aec w tFS
QILORROMA!CRASS SEC1iO�L Z O'1lRONfAi CR03S S6 � oaMno w
Z 2X Buds yConsiucion IXflockMowryConftcom 2XBookMasonryCons cbn FL–1SS42,8 n
Pm�or ,
a
NOTE:SlieMWdSmmnut penetm*a � r• �'
meld(maintdn o trih.3l8'edAe dMancel.
1 2 E
pX s . • . " �� C 3
e
G1 G2 a
4 / D � .
L E y
/ C
2
Note: s 1y SEEMM3
1.Inckw4k eperb=ftdr4an 2
each enddb&,"w tMSM& SS
2.Meld fdwa rnbly boated rftM 4 HOZZOWAL C OSS !ON G1 5
eochend oftheboltommiL a wetd3wcont on :
S.AnMwaxed to head WM 62
IS)Nx 112"PPHSMS. E 3
ALTS MEANCHOMNG LOCATION EXTERIOR IMEROR a n
141,CMN. SHOWN ONTrE SHEEP
A 4 � �
E G2 G1 a
C C 2 15
• • INTERIOR 8 • 1d
a L 0
10 � G1 G 13 z
. • SFENOTE1 11 ' D 14 SMNOTE 2
12 i 16 � � a
C k�
• G1 G2 L
3 • m
3 D
D
.. ♦�1 lV2
6 1 E WE 2/19/14
=
4 1-1/4MN f N.T.S.
1 2 QCM-ROR EML M.) �� am on A
E i N OONf L CROSl SECTION 2 A BOSS SECIfON 3 C DO W. !FS d
a 2x Rudy Mmony Corohuclbn s 1X Bach Moiorxy CollltMIMM DOOM xa. f
FL-16842.6
sxhLr.•T_s� O
i�
a
M "
ter 'r
$ 3 Er
Jk 8
it a
V MAX.
O.C. +{
C.(rip.)
4
i
N
Ix PYP-) S,
Jf
MR) ,,`���Sl{tlrfrryrr�,'i
.�otl''rAO4''
r
� N0.4Tf0�
Oc�Od 2O 7 3 I
q PROOUM
New&lurh Lyndon F.SehmWt
N t LOPWUE TO ATM EO. 201 J .[.No. 43900 ��i e► 1�````
J E,,
1.ANCHOR LOCATION LFS 2 R AD KPART OR�eesuw l: wlmm LTi'INC.
tA iUPDATE TO 3TH EP. W15J FBC LFS SCK P.C. Bou 230.Vatrlo% PL 35606
Phone No:e1J.ANA1107
IMMONS ANCHORING FM CA No."I
0 Mai's mm.nuu.on.a ConSaLTAN"IND.
IlieientsMlewSO&* •Rald�Redllct •169/lNalimnhl 16M2 S6
P
W
329"
1Ho
� � 1
W O
W w Q
►-am
L jr-11
� i
a am �+021'
w
Dim
� 0�
L149
0.96' D
G-) TI, p d
ao
in
I l AT 5
`�1�Uw�Hr�gl��/i
F N06 43409 5
00ft FDS.2°17 : 1
y ¢ $ 11 q PRODUCT: �i Q
UPMTE MW FD. 4017 F8C JK
NerSDWh
1 ADQED ALTt ANg%ZIR TION EM111111N
o y f 1 1 REvmE YODEL famElAug GEAZIM JK PAIR OR ASSQI Y: 6UWN0 OMMLYAN}S. INC.
R N 7`c IA } B 23 13 WMTS TO STN EEL 2014 LPS P.O. Sex 230,Vakiae.FL 33626
�. A COMPONENTS FSK
No- 613.032.2127
FSK OA No. 0813
Q 30t4 R.W.9unnela COMxuur�Ire.
BRLOFMATEINA4S ������,,, ,,.*»,•, ',��i4�� gag
116Ntf DEOCM770N JIl419fAT � t �. i�
B 2K BUCK >=0 e i5
WOOD
C I Jf MAX.SHIM SPACE z
D 1/4"X 2-Wr PRI ELM OR ItW COAICRETE SCREW STEEL �N•�L � � � �n
E MASON
O HOLLOW BLOCK.CON CONFORMTO
ACI CONCRETE '�i���'�•.., ,``,����� n
F 0 SMS 1-1 4' 57193. Im Fu l
JSTEM MK IM MY VWMAMGRAM 33N=33 kd rnlr6 RP4 W SR83
K THOPPHSEE-DRIWNGSMS STEEL •
L SMS 9-1 STEEL 4€
1 EX1R DED NYL • RIGID PVC sAr
2 EXTRUD VINYL GLABNG BEAD 7 • RIGID PVC GLASS OR 7/B"Oil GLASS THIO
3 EXTRUDED VINYL GLAZING BEAD 142W• RIGID PVC GVJNG SEALANT d
4 BOTTOM RAS Rm PVC (�114M IB'ANNFAL®GIASS "'333
5 TOP RMft4 * RIM PVC
6 MEEMRIGB)PVC
7 l SARIGID PVC OA9VOPVsINSERIAYFR
8 NANDLERIGIDPVC x
3
9 MEEIINGSTILE i�NFORCEMENT 6063-TSAUUM f/rANNEgEDGIASS
10 LOCKSIUR13NFORCMW 6063-TSALUM MSPACE j
11 SASH LOCK 11@��EA�GIASS
12 KEWER -
13 HANDLE SHE RLORCEMT3JI 6063-T5 ALUM METAL RBNFORC®BU[YL a
14 ROLLER #2433-lom
15 SILLRISER 6063-75ALUM Not approvedfor use above 30feet lnthe'11VHI
16 ROLLER TRACK 6063-TSALUM Gl T7ETAR �
17 ANUFTALUMJNUM 6063-TSAWM
18 1 BOTTOM RAIL REINFORCEME IT 6063-TS ALUM `
20 WEA P .87-X
•1HE APPROVED WHITE RIGID PVC EXTERIOR EXTRUSIONS FOR 141NDOWS ARE TO BE PRODUCED BY �'
Li
EXTRUDERS LICENSEES IN'AAMA CERTIFICATION PROGRAMS FOR RIGID PVC ERTRI=NS•. GLASS BRE 716'O.A.GLASS 1HK. Gi
GlA>TIG SEALANT
Pow-"-"
118'ANNFA!EDGtASS
O.W SAFLEX4 PVB MBttAYER
m
C] 1 Ar ANNEALED GLASS N
AIR SPACE a a m $
118'TEMPERED GLASS a z
METAL RENFORCED BUTYL WL 2/19/74 9
wrL N.T.S. 9
as er X •
dLAiRIG DE7AM1 CHL or LFS 3
w: rc
0
FL-16842.6 e
Tow-OF-L 10
i
NewSouth 2526 Okeechobee Blvd.•West Palm Beach,FL 33409-4006
WINDOW ouTrt h 561-712-9000•561-478-4100 fax
NS
www.NewSouthWindow.com Lic#CRC-1330822
7mtIn Florida for Florida ones Date d
TO /� QN S E-mail beam. itr-K AR Ya4 oo. c� ►�^
f ` 9sy-3�
.j'rrdj w.. ���L ,f�ilL Home Phone 0'31(1 ell Phone
I
City f /f C OF State zip.3 06�! Business(Mr./Mrs.)
Replacement Windows•Entry&Patio Doors•Storm Doors•Impact Resistant Windows&Doors
WHOLESALE&RETAIL WINDOW CONTRACT
NewSouth window solutions agrees to measure,manufacture or furnish and service the following custom made windows for the amount STIPULATED BELOW:
All NewSouth Vantage Series Windows include Double Pane,Low-E glass with Argon gas,and 12 point fusion welded corners.
All Vantage windows are sealed and vacuum tested for uperior argon retention.
Co1or0DII6s(whole window) White ❑Tan LlBrome(enterior only) IntgdorCnIgo ite ❑Tan
Colommayvaryslightyfrommmple (Initial)
LOW-E GLASS: ❑366 GLASS V340GLASS OBSCURE GLASS L3 YES O TEMPERED GLASS❑YES O
ALL SASHES ARE ARGON FILLE WITHOUT EXTRA CHARGE LOCATION: LOCATION:
�°S^
GR1O -Sr ❑Mantage L3 6Tantageg000 Single Hung XiVantage 9000 Impact Elother:
QUA47M DOUBLE HUNG E-VANTAGE ❑ ttu PATIO DOORS
(HALF-SCREEN STANDARD)O Full Sawn ❑Impact O non-Impact 0 Open Praire Grids
on
SINGLE HUUNG CH HUNG
❑
900D0mpactSINGLE0 HUNG(HALF-SCREEN) 0 5/0 x 6/8
❑Impact OnaMmpact ofslde outate side ooarrows
i gIn(OSU)�ion 0 9/0X6/8
❑5/0 x 8/0 ❑9/0 X 8/0
2 LITE SLIDER E-VANTAGE ❑ 116/0 X 6/8 0 12/0 X 6/8
/
(XX,HALF-SCREEN STANDARD)O Full Sawn 0 6/0 X 8/0 0 12/0 X 8/0
9 0SLIDER 0O or XO ❑8/0X6/8 ❑16/0X6/8
outside looking in impact O non-impa ❑8/0 X 8/0 ❑16/0 X 8/0
ou
PICTURE WINDOW VANTAGE
(NO SCREEN)
❑impact 0 noImpact 3 PANEL PATIO DOORS
❑impact O non-impact
3 LITE SLIDER WITH PICTURE
WINDOW(7 SCREENS) Indicate stM draw arrows for direction ofslide
outside looking In
O Impact O non-Impact
1/4-12-1/4 configuration
4 PANEL PATIO DOORS
IIfIIIIII�IIIIIIIII tl AWNING&HOPPER ❑ImpactOnon-impact
IVF+ a ® CASEMENi(OSLI) =1i1GWNGE
NGHf HINGE Indicate size,drawarrom fordirectlon of slide
B DOUBLECASEMENT omsidelookingln
O impact O non-impact
O HALF Q O EYEBROW El QUARTER-ROUND El TRAP C1 OTHER
ROUND (DRAW IN SPACE)
GRID STYLES ❑STANDARD 0 CONTOUR 0 BRASS/GOLD/PENCIL Was this home built prior to 19787❑Yes❑ o
If yes,the undersigned ogress to theterm dconditions of the
❑Colonial ❑Prairie ❑Open Prairie NewSouth Lead Safe Work Practices Adden m.if house tests postive
for lead pan addition per window will be added to the balance.
I
I -
Buye ig azure
TOTALNUMBER OF WINDOWS ON THIS ORDER: TOTAL DOORS: '*Subject to NewSouth field engineering and approval.
o J
0 Custo)rner agrees to allow NewSouth to display a yard sign until 30 days after completion. TWOVEARS FREE IN HOME SERVICE
BUYER'S RIGHT TO CANCEL , o
BUYER MAY CANCELTHIS CONTRACT BY DELIVERING WRITTEN NOTICE Total price* Cr— 0 Je$
TO THE SELLER AT ANY TIME PRIOR TO MIDNIGHT OF THE THIRD Down payment. S�eGd$
BUSINESS DAY AFTER THE DATE OF THIS TRANSACTION.BUYER MAY Delivery/commencement. $
USETHIS CONTRACT AS THAT NOTICE BY WRITING"I HEREBY CANCEL" Balance due upon final $
AT THE BOTTOM AND ADDING BUYER'S NAME AND ADDRESS.THE window/door installation.
NOTICE MUST BE DELIVERED TO THE SELLER ATTHE ADDRESS SHOWN
ABOVE. Bank Financing 0 Cash on Completion
All material is guaranteed to be as specified.All work is to be completed in a workmanlike manner according to standards and practices.This contract is
valid only with proper signatures.NewSouth shall not be held responsible for time and material delays,strikes,acts of God or any other matters beyond
its control. NewSouth is not responsible for any pre-existing structural conditions. No other work to be done, all other work to be excluded.Owner
agrees that the equity in this property is security for this contract Since this contract calls for made to order goods,it is not subject to cancellation
except I as stated above. Start installation approximately 12--[k weeks from above date. Verbal promises can cause misunderstandings, therefore
this contract constitutes the entire understanding of the parties, and no other understanding, collateral,verbal or otherwise, shall be binding, unless
signe�boties. NewSouth to remove and haul away all job related debris. *AII and discounts allotted. All charges included above.
ThanX X
Buyer's Sign wSouth R es live
x x
Buyer's Signature NewSouth Manufacturing Authorized Officer
NewSouth
WIN DOW SOLUTIONS
2526 Okeechobee Blvd,West Palm Beach,FL 33409•561-712-9000•CRC 1330822
Property Information Building Information
Owner: DERRICK BEANS Wind Zone: 170 MPH.
Address: 11091 S INDIAN RIVER DRIVE Exposure Category: C
FORT PIERCE,FL 34982 Minimum Building Dimension: 25 ft.
Mean Roof Height: 15 ft.
jl� Risk Category: H
I
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
1 Int 60 59.75 7 35.6 -38.8
2 Int 60 59.75 7 35.6 -38.8
3 Int 60 59.75 7 35.6 -38.8
4 Int 60 59.75 7 35.6 -38.8
Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code.
Page 1 of 1
Opening I Size
(WxH)
1. HORIZONTAL SLIDER 60 x 59 3/4
(DININGROOM)
2. HORIZONTAL SLIDER 60 x 59 3/4
3. HORIZONTAL SLIDER 60 x 59 3/4
4. HORIZONTAL SLIDER 60 x 59 3/4 = Z u
3CD 0
2 � �
CA
�o re
4 � re
IQ�Z
I�/ 3
a
O
N
W
>R co
N
ZQ �
Q W co
W > L
m
Y U
Z
V ¢ �
LU
E5 a.
o C �
rn 0
LL0
COPY-E-TEMPE9T-
R AM
NOT TO SCALE
OATS
Mar 14,2019
PAGE DESCRIPTION:
Site Plan
PAGE: OF�