HomeMy WebLinkAboutProduct Approval t �
MM DADS MIAMI DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION
Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
Sun-Dome by Daylighting Technologies,Inc.
P O Bog 100683
Ft.Lauderdale,FL 33310
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.
The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control
Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control
Section(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform
in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke,modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right
to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product
or material fails to meet the requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the High Velocity
Hurricane Zone of the Florida Building Code.
DESCRIPTION: Sun-Dome Skylight
APPROVAL DOCUMENT: Drawing No. 1,titled"Sun-Dome/Tubular Skylight",prepared by Daylighting
Technologies Inc,dated 10/22/07,with last revision dated 12/05/11,sheet 1 of 1,signed and sealed by Masood
Hajali,P.E.,on 07/15/18 bearing the Miami-Dade County Product Control revision stamp with the Notice of
Acceptance number and the expiration date by the Miami-Dade County Product Control Section.
MISSILE IMPACT RATING: Large and Small Missile Impact Resistant
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and the
following statement: "Miami-Dade County Product Control Approved or MDCPCA",unless otherwise noted
herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in
the materials, use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any
product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then
it shall be done in its entirety.
INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA#16-1018.09 and consists of this page 1, evidence submitted pages E-1,E-2&E-3
as well as approval document mentioned above.
The submitted documentation was reviewed by Helmy A.Makar,P.E.,M.S.
� NOA No. 18-0717.07
MrA�DACOU NTY /! Expiration Date: 12/15/2021
Approval Date: 09/06/2018
Page 1
Sun-Dome by Daylighting Technologies,Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
1. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL 4 07-0917.03
A. DRAWINGS
1. Drawings prepared by Daylighting Technologies, Inc., titled "Sun-Dome/Tubular
Skylight", Drawing No.], Sheet I of 1, dated 11/07/01, with last revision dated
10/22107, signed and sealed by Terrence E. Lunn, P.E.
B. TESTS
1. Test reports on 1)Air Infiltration Test,per FBCC. TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
3) Water Resistance Test,per FBC, TAS 202-94
4)Large Missile Impact Test per FBC, TAS 201-94
5) Cyclic WindPressure Loading per FBC, TAS 203-94
along with marked-up drawings and installation diagram of tubular dome,prepared
by Hurricane Test Laboratory, LLC, Test Report No. 0454-0903-06, dated 01/16107,
signed and sealed by Viny J. Abraham, P.E.
C. CALCULATIONS
1. Anchor calculations letter issued T.E. Lunn, P.E., LLC, dated 10130107, signed and
sealed by Terrence E. Lunn, P.E.
D. QUALITY ASSURANCE
1. Miami Dade Building Code Compliance Office (BCCO).
E. MATERIAL CERTIFICATION
1. None.
F. STATEMENTS
1. Test Compliance letter issued by Hurricane Test Laboratory, LLC, issued on 01/16107,
signed and sealed by Vinu J Abraham, P.E.
2. Code compliance letter issued by TE Lunn, P.E., LLC, dated 10130107, signed and
sealed by Terrence E Lunn, P.E.
3. No financial interest letter issued by T.E. Lunn, P.E., LLC, dated 10122107, signed and
sealed by Terrence E. Lunn, P.E.
2. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL 011-0817.13
A. DRAWINGS
1. None.
elmy A.Makar,P.E.,M.S.
Product Control Section Supervisor
NOA No. 18-0717.07
Expiration Date: 12/15/2021
Approval Date:09/06/2018
E- 1
Sinn-Donne by Daylighting Technolotdes,Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
B. TESTS
1. None.
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. Miami Dade County Building and Neighborhood Compliance Department(BNC).
E. MATERIAL CERTIFICATION
1. None.
F. STATEMENTS
1. Code compliance letter issued by T.E. Lunn, P.E., LLC, dated 07/29/11, signed and
sealed by Terrence E. Lunn, P.E.
2. Letter issued by T.E. Lunn, P.E, LLC, dated 07/29/11, signed and sealed by Terrence E.
Lunn, P.E., certify that he is still in the engineering business.
3. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL# 11-1212.04
A. DRAWINGS
1. Drawing No. 1, titled "Sun-Dome/Tubular Skylight", prepared by Daylighting Technologies
Inc, dated 11/07/01, with last revision dated 12/05/11, sheet I of 1, signed and sealed by
Terrence Earl Lunn, P.E., on 12/05/11.
B. TESTS
1. None.
C. CALCULATIONS
1_ None.
D. QUALITY ASSURANCE
1. By Miami-Dade County Department of Permitting, Environment, and Regulatory Affairs
(PER-4).
E. MATERIAL CERTIFICATION
1. Addendum letter prepared by HTL, dated 12/05/11, signed and sealed by Vinu J.
Abraham, P.E., stating the correct weather seal.
Helmy A.Makar,P.E.,M.S.
Pro act Control Section Supervisor
NOA No. 18-0717.07
Expiration Date: 12/15/2021
Approval Date:09/06/2018
E-2
Sun-Dome by Daylighting Technolozies,Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
4. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#16-1018.09
A. DRAWINGS
1. None.
B. TESTS
1. None.
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. By Miami-Dade County Department of Regulatory and Economic Resources (RER).
E. MATERIAL CERTIFICATION
1. None.
F. STATEMENTS
1. Florida Building Code, 2014 Edition, Compliance Letter issued by T.E. Lunn, P.E.,
LLC, dated 12/05/16, signed and sealed by Terrence E. Lunn, P.E.
5. NEW EVIDENCE SUBMITTED
A. DRAWINGS
1. Drawing No. 1, titled "Sun-Dome/Tubular Skylight", prepared by Daylighting Technologies
Inc, dated 10122107, with last revision dated 12105/11, sheet I of 1, signed and sealed by
MasoodHajali,P.E., on 07/15118.
B. TESTS
1. None.
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. By Miami Dade County Department of Regulatory and Economic Resources (RER).
E. MATERIAL CERTIFICATION
1. None.
F. STATEMENTS
1. Florida Building Code, 2017 Edition, Compliance Letter issued by MasoodHajali, P.E.,
dated 06/18118, signed and sealed by Masood Hajali, P.E.
e my A.Makar,P.E.,M.S.
Product Control Section Supervisor
NOA No. 18-0717.07
Expiration Date: 12/15/2021
Approval Date:09/06/2018
E-3
r •
r+ar�
PILE WEATHER 5EAL POLYCARBONATE DOME (I/&NOMINAL THK
(5CHLEGEL 0.36"x 0.269 VAC. FORMED) GE LEXAN XL-10 DADE CO.
APPROVED
RUBBEM-5.WASHER DARK FOAM TUBE 5EAL
4 -RUBBER a-R1NG5 DOME FA5Tl=N R-#6 x I'STAINLE55
STEEL SCREW AT 9"O.C.
ROOFING DETAtL5 511ALL COMPI.YWITH
CHAPTER15 OF THE FLO?JDA BUILDING ADJU5TABLE TOP TUBE
CODE. 4"MIN. CLEARANCE FROM DOME UP
f—
TO ROOF SURFACE FOR 5HINGLE 4 BUR.W/O
IN5ULATION. FOR IN5ULATION AND TILE
ROOF:ADD THE TILE HEIGHT AND THE MIN. 4' 0.040 ALUMINUM ROOF FLASHING
INSULATION THICKN955 TO 4". (ADHLEY--3105 A5TM 5209)
ROOFING 5Y5TEM
ROOF SHEATHING
RING 5HANK FLASHING NAIL
7/1G"OHDx i-1/2"LG.
DESIGN PRE55URE
RATING: +/— 100 P5F
SUN—DOME CONNECTION DETAILS
APPROVED FOR USE IN
tilt. AND OUTSIDE HVHZ.
PV.9 z)7 o
Q O O " 6
C �
A o 8
RING SHANK NAIL I 1 GA.
x7/1G" HDx I-1/0
e
o Q o 0
I-!/2"TYP.
B
ROOF FLASHING DIMEN51ON5 SUN—DOME DIMENSIONS
ROOF FLANGE DIMEN510N5 DOME FOR ts=L=
MODEL YDIA.I X R5E A B C FA5TENER5
2!" 22" 9.5" 21.5® 29.0° 5 SPACES +/-6" 8
13" I4" G,75" 13.5" 23.5" 4 5PACE5 +1-5' 5
10.5" 20.0° 3 SPACES +/-5" `t
e.
a�;; REVISION: 10,22.07 ADDED REG NO,AND NAILING
,,^.. f v 12-5-11 TO 5CHLEGEL SEWAL-ag lip
o
+ , TRODUCT
zoolb� � SUN—DOME/TUBULAR SKYLIGhT
SCALE: i 2"=f'-O" JIUMINUM CUR13/PC DOME '
DATE: 10122/07
CAD DWG PILE: MrS. aAYLIGHTING TECHNOLOGIES DxcMG
DRAWN HY: TEL RIVIERA BEACH, FL 33404 1 OF 1
CHECKED BY: TEL
� 1 i
NFRC Product Certification Authorization Report
NFRC _
�' II
IA: Keystone Certifications, Inc.
Manufacturer: Sun-Dome by Daylighting Street: 8352 Garden Road City/State/Zip: West Palm Beach,FL
Technologies,Inc. 33404
Product Series: 13 inch Tubular Skylight Type: Skylight CPD Number: SDO-K-3
Simulation Lab: SATI Simulation Report Date: 3/12/2010 Simulation Report Number: 95656.02-116-45
Test Date: Initial Certification Date: 03/30/2010 Re-Certification Date:
Revised Date: Mar 12 2010 12:OOAM Expiration Date: 03/30/2014 Print Date: 03/30/2010
Air Leakage:
Status Pr°dam. `� M r' F Frame/S'ash G az. ow Gap.; S acer Gap Grids Dividers Tint U-Factor SHGC V7 Condens
Num: Code; La ers. Surface Width s Fill y. Resist.
00001-00001 Standard Diffuser— AUN 2 1.15 N Fill 1: N CL 0.19 0.19 -
Glazing info: AIR
Frosted inner dome (100)
with 2-1/2"rise,
Polycarbonate sheet,
2 layers fo 5/8"lexan
with air pockets
(honeycomb)
separated by air gap
Baseline Information
Test Lab Test Date Test Size Tested Standard Test Report Number
U-Value U-Value
0.00
Comments:
SHGC test:96211.01-301-41-R1.
I hereby certify that all requirements for NFRC Certification Authorization have been met and that the above information is true and correct,to the best of my knowledge.
Digitally signed by Jennifer R.Heitzenrater
-Date:2010.03.30 11:28:01-04'00'
Authorized IA Signature:
Page 1
j-
j •YSTTt
, l KEYSTONE CERTIFICATIONS, INC.
564 OLD YORK ROAD, SUITE 5
ETTERS, PA 17319 / PHONE 717-932-8500
Notice of Product Certification Authorization
National Fenestration Rating Council
Issued To: Certification Number
7295
Manufacturer: Sun-Dome by Daylighting Technologies, Inc
Product Line Number
Address: 3612 Reese Avenue
West Palm Beach FL 33404 SDO- K-003
Man'f Code SDO Revision Date
Cert Date: 3/30/2010 3/30/2010
The Following NFRC Product Line Has Been Authorized For Certification:
Model/Series: 13"Tubular Skylight
Operator Type: TDDY
Frame Type: AL
Sash Type: N
Exp. Date: 3/30/2014
Ratings Authorized For Certification:
Rating Property Authorized
NFRC 100 U-factor ❑
NFRC 200 Solar Heat Gain Coefficient 0
NFRC 200 Visible Light El
NFRC 400 Air Leakage
NFRC 500 Condensation Resistance
Fenestration products are not NFRC Certified unless manufactured and
labeled in accordance with the current version of NFRC-700, Product
Certification Program requirements.
Attached are the Certification Authorization Reports printed from the NFRC database.
The Manufacturer is authorized to label the options listed in the reports.
Please notify Keystone of any errors or omissions within 10 days of receipt.
Due diligence was used in authorizing these products for certification. By accepting this report the licensee agrees to hold harmless and
indemnify Keystone Certifications,Inc.from all claims or liabilities which may arise based on this certification authorization.
Certification authorization is based on NFRC program requirements and simulation and test reports from accredited laboratories.
W W W.KEYSTON ECERTS.CO M