Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Design Pressure Calculations
• Property Information Building Information Owner: Dwyer Wind Zone: 160 MPH. Address: 14185 Cancun Exposure Category: B Ft Pierce,Fl 34951 Minimum Building Dimension: 24 ft. Mean Roof Height: 15 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 Int 36 80 7 31.0 -33.8 2 End 53 - 55 7 31.0 -40.5 3 Int 53 55 7 31.0 -33.7 4 Int 53 55 7 31.0 -33.7 5 End 109 84 7 28.6 -35.7 6 End 103 84 7 28.7 -35.9 7 Int 113 84 7 28.5 -31.3 8 Int 74 55 7 30.3 -33.0 9 Int 26 38 7 32.5 -35.2 10 Int 26 38 . 7 32.5 -35.2 • Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page 1-of 1