HomeMy WebLinkAboutDesign Pressure Calculations 11 SS% i 1 Property Information J Building Information i Owner: Tierney Wind Zone: 160 MPH. Address: 1 Puerto Sol • Exposure Category: B Ft Pierce,Fl 34951 Minimum Building Dimension: 24 ft. I Mean Roof Height: 15 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 Int 52 62 7 30.8 -3;3.5 ...2 Int 26 —..40._... ........._..-- 7 32.5 —...:....__ -35.2 ..................—-- 3 Int 26 40 7 32.5 -3.5.2 4 • Int 74 60 - 7 30.1 -32.9 5 Int 113 84 7 28.5 -31.3 II __..._....6........_. End ------103 -...............__......._............___...-84_.._.................---------................_7 __..._... 28.7 ._._.......... -35.9• 7 End 109 84 7 28.6 -35.7 8 Int 52 55 7 31.0 -33.8 9 Int 52 55 7 31.0 -33.8 ,I 11 • I Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page 1 of 1 1 1 1