HomeMy WebLinkAboutDesign Pressure Calculations 11
SS%
i
1
Property Information J Building Information i
Owner: Tierney Wind Zone: 160 MPH.
Address: 1 Puerto Sol • Exposure Category: B
Ft Pierce,Fl 34951 Minimum Building Dimension: 24 ft.
I Mean Roof Height: 15 ft.
Risk Category: II
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
1 Int 52 62 7 30.8 -3;3.5
...2 Int 26 —..40._... ........._..-- 7 32.5 —...:....__ -35.2
..................—--
3 Int 26 40 7 32.5 -3.5.2
4 • Int 74 60 - 7 30.1 -32.9
5 Int 113 84 7 28.5 -31.3
II __..._....6........_. End ------103 -...............__......._............___...-84_.._.................---------................_7 __..._... 28.7 ._._.......... -35.9•
7 End 109 84 7 28.6 -35.7
8 Int 52 55 7 31.0 -33.8
9 Int 52 55 7 31.0 -33.8
,I
11
•
I
Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code.