HomeMy WebLinkAboutProduct Approvals-Roof Shingles OV\IP ,m - O 7C-6°S,•
(qaci_01
®
L5. i�OR[pA DNpAq'tRASN�'OP � ,' £ c *�••
°.,Business & Professional RegutatI,on .y. -
�Y
.: p$FR4IO OWDEplk ontRa it1SlON9 d6N1ACTnaPX
BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats&Facts I Publications FBC Staff I BCIS Site Map I Links I Search
Florida RECEIVED
". USERPublicrAPRd ?pr
cr.-rr r,mn
Product Approval Menu>Product or Application Search>Application List>Application Detail Permitting De
St. Lucie Countyent
rtEPPEOF THE FL# FL10674-R13
SEcitEr iY Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived L C
Product Manufacturer Owens Corning4101
Address/Phone/Email One Owens Corning Parkway
Toledo,OH 43659
(740)404-7829
greg.keeler@owenscoming.com
Authorized Signature Greg Keeler
greg.keeler@owenscorning.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Corning PKWY
Toledo,OH 43659
(419)376-8360
mel.sancrant@owenscornig.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
17; Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J.M. Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 05/16/2020
Validated By John W. Knezevich,PE
✓a Validation Checklist-Hardcopy Received
Certificate of Independence FL10674 R13 COI 2017 01 COI Nieminen.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161 2016
ASTM D3462 2010
ASTM D7158 2011
Equivalence of Product Standards
Certified By
Sections from the Code
•
•
Product Approval Method Method 1 Option D
Date Submitted 10/10/2017
Date Validated 10/11/2017
Date Pending FBC Approval 10/15/2017
Date Approved 12/12/2017
Summary of Products
FL# Model,Number or Name Description
10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab,5-tab, laminated,starter and hip&ridge shingles
Shingles and Starters
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL10674 R13 II 2017 10 FINAL ER OC ASPHALT
Approved for use outside HVHZ:Yes SHINGLES FL10674-R13.pdf
Impact Resistant: N/A Verified By: Robert J. M. Nieminen PE-59166
Design Pressure: N/A Created by Independent Third Party:Yes
Other: Refer to ER,Section 5. Evaluation Reports
FL10674 R13 AE 2017 10 FINAL ER OC ASPHALT
SHINGLES FL10674-R13.pdf
Created by Independent Third Party:Yes
Back Next
Contact Us::2601 Blair Stone Road Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal
address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,
please click here.
Produuctt Approval Accepts:
1..;• i� Zheck
Credit.Card,.
Safe
securityM ETRics'
•
•
' I
II I
Y
} EXTERIOR RESEARCH&DESIGN, LLC.
Certificate of Authorization#9503
TRINITY ERD
CHRISTIAN STREET, UNIT#13
ERD OXFORD,CT 06478
(203)262-9245
EVALUATION REPORT
Owens Corning Evaluation Report 037940.02.12-R8
One Owens Corning Parkway FL10674-R13
Toledo,OH 43659 Date of Issuance:02/06/2012
(740)404-7829 Revision 8: 10/09/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code
sections noted herein.
ti� NE, i c its Ccoorott%/twthi[i
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency'noted
herein and FBC 1507.2.7.1/R905.2.6.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. Trinity'ERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity'ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
* a
•
�' i'eTa :4
Robert J.M.Nieminen,P.E. �'tS^ 'tG;t 4 The facsimile seal appearing was authorized by Robert
Florida Registration No.59166,Florida DCA ANE1983 a_ Jln�n,ttu"`' Nieminen,P.E.on 10/09/2017.This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. TrinityERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity]ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product. I
5. This is a building code evaluation. Neither Trinity)ERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
re/
\NI TRINITY ERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning, have demonstrated
compliance with the following sections of the 6th Edition (2017) Florida Building Code and Florida Building Code,
Residential Volume through testing in accordance with the following Standards. Compliance is subject to the
Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011
3. REFERENCES:
Entity Examination Reference Date
UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007
UL LLC(CER9626) Physicals&Wind Resistance 20120516-R2453 05/16/2012
UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006
UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012
UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014
UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC(TST9628) Physical Properties Classification letter 02/13/2014
UL LLC(TST9628) Physical Properties Classification letter 10/02/2015
Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various
UL LLC (QUA9625) Quality Control Service Confirmation Exp.05/16/2020
4. PRODUCT DESCRIPTION:
4.1.1 Classic'and Supreme®are fiberglass reinforced,3-tab asphalt roof shingles.
4.1.2 Berkshire®are fiberglass reinforced,4-tab asphalt roof shingles.
4.1.3 DevonshireTM are fiberglass reinforced,5-tab asphalt roof shingles.
® Duration', TruDefinition® Duration' Duration' Premium Cool, TruDefinition® Duration' Designer Color
Collection, Tru Definition Oakridge' Co:ij!;r";to and WeatherGuard® HP are fiberglass reinforced, laminated
asphalt roof shingles.
4.2 Hip&Ridge Shingles:
4.2.1 Berkshire' Hip & Ridge Shingles, High Ridge, WeatherGuard® HP Hip & Ridge Shingles, ProEdge Hip & Ridge
Shingles and DuraRidg&"Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles.
4.3 Accessory Starter Strips:
4.3.1 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity!ERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory
for fire ratings of this product.
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8
Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 2 of 8
,i, CNC .
\NI TRINITY 1 ERD
5.4 Wind Classification:
5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1
and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H, indicating the shingles are acceptable
for use in all wind zones up to Vasd = 150 mph (V„It = 194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
I 5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are
Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the
shingles are acceptable for use in all wind zones up to Vasa=150 mph (V„1 =194 mph). Refer to Section 6 for
installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C, as defined in FBC 1609.4.3, and a mean
roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions
outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval,or be Locally Approved per Rule 61G20-3,per FBC 1507.2.3,1507.2.4 or R905.2.3.
6.2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using
minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following
exceptions:
➢ Berkshire shingles require minimum five(5)nails per shingle.
> WeatherGuard®HP shingles require minimum six(6)nails per shingle.
➢ Devonshire"'shingles require minimum six(6)nails per shingle.
> Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. See figures below for details.
6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus: j
Felt underlayment -I Deck Felt andedayment --i.., pack Sdf edheredi
�U weathed.ock�
Self-adhered •7�. underlayment
WeatherLocke
% underlayment C�L
Drip_ 1/, `f ,Drip edge
edge ��lf Drip edge 9 �jjfl
4e Nails lorated
Nags located
�`from gave
® 2= from gave
Install first Self-sealing adhesive Instal first Starter Snip Plus SeNsearing adhesive
Starter Strip , ® positioned along gave p „® positioned along gave
shingle with ` with 6"removed
6"removed
Starter Strip shingle overhangs eaves and rakes'k-% Starter Snip Plus overhangs eaves and rakes 114--3/4"
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8
Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 3 of 8
no
TRINITY ERD
&22,1.
R/ti*+%Iiia Pur•Iri-Yil�ra 5–it�LC?C� , •v Vaf o iaRc i
4 Nail Pattern 6 Nail Pattern
Esquema con 4 clavos. Esquema con 6 ciavos.
=MEE "
>r — k— 12" ��
} 111111111L
55/8"Exposure. NN® 5 518"Exposure Nails
Exposition de 55/8pgfg. crams Expos cion de 66J8puig. 5518"Exposute Clavos 5:518"Exposufe-
Evposicion de 55/8 putg. Exposician de.5 51/8 pulp
Standard Fastening Pattern 6-Nail Fastening Pattern
Fastening for Slopes Greater Than 21:12
SuroHm77 fastening men width
Hay Typical
• 1" 12" 12"
C ari+co .•.«m • • �a wo •u <. •
•
Four 1"Spots of Asphalt Rooting Cement
Mansard or Steep Slope Fastening Pattern
6.2.1 Minimum Nailing—WeatherGuard®HP:
•
rim
—�_ g �-1.{ Single 61de View.
1�� z• .`l � 1 �*. Ylib Lbial
T•rr•Y F"".a Cisms inbass
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8
Certificate of Authorization#9503 6TH EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 6 of 8
!_,
,. ,
1 l-RINI'T'Y ERD
,r sa
II
Prevailing Standard X11'
Wind Direction Fastening
Sealant Strip - Pattern }
�•� 6°Exposure,..q1110 ,C i NI.- -..I I"
*1 ____iiI 12° I Sealant
f,�
,` — Fasten 7'h'
I
6"Exposure
Cover Exposed 1
I ,
�i Fasteners with i
` Roof Cement I'-12°----'1
I r t -c
6.3.6 Minimum Nailing–DuraRidge""Hip&Ridge Shingles:
Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning
published installation instructions for their minimum requirements.
FtoraiingWin:I Diracucn TYoeop View
Diraciondnen
Dirnrdan dalvivi6opradornimnto **II" Vista superior
r 1-14*
i
S /cle
21 Owens Coming SurcNu# ✓ CdYO
►aye d J.. '
loco -`_`a I
s°ot 1
I
I II 1 ..
'P 4 4 y a `mlatt
1Prtba1 I u I�
1
�,, — 1
a a It 12"
•
7. LABELING: j
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency i noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1/R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS: 1
I
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625;(631)546-2458; Kanchi.Agrawala-Dokania@ul.com
- END OF EVALUATION REPORT-
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8
Certificate of Authorization#9503 6T'EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 8 of 8