HomeMy WebLinkAboutWindload Calculations 1 I' I I .1 Is, E0 .s TE ,„,1 „ . ' "Building Our Quality Reputation. 11 ,i One Customer At A Time" . ., SCC131150472 Property Information Building Information Owner: DAVID RATH&KRISTEL HOLTZ Wind Zone: 170 MPH. Address: 5604 DEER RUN DR Exposure Category: C FORT PIERCE,FL 34951 Minimum Building Dimension: 48 ft. Mean Roof Height: 20 ft. Risk Category: II i Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 hit 53 28 7 40.1 -43.5 2 Int . 23 23 7 40.2 -43.6 3 End 58 28 _____7 39.8 -53.1 _ - 4 Int 70 34 7 38.8 -42.2 5 Int 70 34 ______ 7 38.8 -42.2 6 End 35 58 7 39.3 -52.0 7 End 35 58 7 39.3 -52.0 _ 8 Int 35 58 '7 39.3 -42.7 9 Int 35 58 7 39.3 -42.7 10 Int 35 58 7 39.3 -42.7 11 hit 35 587 39.3 -42.7 12 Int 35 34 -7 40.2 -43.6 13 Int 34 17 _____. 7 40.2 -43.6 ---14 Int 34 17 7 40.2 -13.6 15 Int 34 17 7 ' 40.2 -43.6 16 Int 34 76 7 38.6 -42.0 17 Int 35 17 7 40.2 -43.6 18 Int 1 35 76 7 38.6 -42.0 19 Int -. 35 58 7 39.3 -42.7 20 End 11 50 7 40.2 -53.8 21 End 34 17 7 40.2 -53.8 22 End 35 50 7 39.6 -52.7 23 End 11 50 7 40.2 -53.8 24 End 29 29 7 40.2 •i53.8 1 I Prepared in accordance with:ASCE 7-10,Chapter 30.Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page 1 of 1 _� .- � - WINDOW;Si DOOR�OPENIN`. G--INFORMATION � i, C V �i'` ` ` . _ ,v� A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET 0 40% 4% Definition of Corner Zone-10/o of least horizontal dimension or of the mean roof height,whichever is smaller,but not less than of least horizontal dimension or 3 ft. PRODUCT APPROVAL REQUIRED OPENING MAXIMU MULTIPLE OPENING (Location) IS THIS A ARE GLAZING PRODUCT APPROVED PRESSURE RATING DESIGN PRESSURE M ROUGH WINDOW LOCATION Corner Zone WINDOW TYPE ACCEPTANCE TESTED OPENING MULLION SHUTTERS NUMBER or Interior OR DOOR NUMBER (+)PSF (-)PSF (+)PSF (-)PSF SIZE DIMENSIONS REQ Y/N REQ Y/N/NA 4- --Int _Window 7/8"LamiIG FL15768.9 60 65 40.1 -43.5 48 x 63 53x28 No No 2 Int Window I"Lami IG FL13010.4 55 55 40.2 -43.6 48x72 23x23 No No - 3 End Window 1"Lami IG FL13010.4 55 55 39.8 -53.1 48x72 58x28 No No 4 Int Window 1"Lami IG FL13010.4 55 55 38.8 -42.2 48x72 70x34 No No 5 Int Window 1"Lami IG FL13010.4 55 55 38.8 -42.2 48x72 70x34 No No 6 End Window 7/8"Lami IG FL15780.8 55 65 39.3 -52.0 54 x 76.5 35x58 No No 7 End Window 7/e"LamiIG FL15780.8 55 65 39.3 -52.0 54x76.5 35x58 No No 8 Int Window 7/8"LamiI0 FL15780.8 55 65 39.3 -42.7 54x76.5 35x58 No No 9 Int Window 7/8"LamiIG FL15780.8 55 65 39.3 -42.7 54 x 76.5 35x58 No No 10 Int Window 7/8"LamiIG FL15780.8 55 65 39.3 -42.7 54x76.5 35x58 No No 11 Int Window lie"Lami lG FL15780.8 55 65 39.3 -42.7 54x76.5 35x58 No No 12 Int Window 7/8"Lami IG FL15780.8 55 65 40.2 -43.6 54 x 76.5 35x34 No No 13 Int Window 1"LamiIG FL13010.4 55 55 40.2 -43.6 48x72 34x17 No No 14 Int Window 1"Lami IG FL13010.4 55 55 40.2 -43.6 48x72 34x17 No. No 15 Int Window 1"Lami IG FL13010.4 55 55 40.2 -43.6 48x72 34x17 YES No 16 Int Window 7/8"LamilG FL15780.8 55 65 38.6 -42.0 54x76.5 34x76 YES No 17 Int Window 1"LamiIG FL13010.4 55 55 40.2 -43.6 48x72 35x17 YES No 18 Int Window 7/8"Lami 10 FL15780.8 55 65 38.6 -42.0 54 x 76.5 35x76 YES No 19 Int Window 7/8"Lami 10 FL15780.8 55 65 39.3 -42.7 54 x 76.5 35x58 No No 20 End Window 1"Lami IG FL13010.4 55 55 40.2 -53.8 48x72 11x50 No No 21__ ___:End ___ _Window I"Lami IG FL13010.4 55 55 40.2 -53.8 48x72 34x17 YES No 22 End Window 7/8"Lami IG FL15780.8 55 65 39.6 -52.7 -54 x-76:5- 35x50 -YES ------N-6- - FILFpay WINDOW& DOOR OPENING I°NFORMATION n.; mm A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET Definition of Corner Zone-10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft. OPENING (Location) IS THIS A PRODUCT PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE ARE GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW LOCATION Corner Zone WINDOW ACCEPTANCE OPENING SHUTTERS NUMBER or Interior OR DOOR TYPE NUMBER (+)PSF (-)PSF (+)PSF (-)PSF TESTED DIMENSIONS MULLION REQ Y/N/NA SIZE REQ Y/N 23 .._ EndWindow I"LamiIG FL13010.4 55 55 40.2 -53.8 48x72 11x50 No No 24 End Window I"Lami IG FL13010.4 55 55 40.2 -53.8 48x72 29x29 No No