Loading...
HomeMy WebLinkAboutProduct Information-Mini split • M.-SERIES SUBMITTAL DATA:vMSZ HM12NA& MUZ-HNII2N + .MITsugts t 12,000 BTUIH WALL-MOUNTED HEAToPUMP SYSTEM, . / ELECTRIC, . Job Name: • System Reference: Date: ;I .._.._................................................._....._...................Indoor Unit:....................._.......--------..............-----------...._....._ Outdoor Unit:_......----...__.......__........._.._.._ _-.Wireless Remote Controller• ; MSZ-HM12NA MUZ-HM12NA • •. "ata �. a� `�� I011 111 Int `W8 a , 1111111111001011 �� . ° .11 i'1111011111111111111111101 tim � � 1111111111I�£I� y ; GENERAL FEATURES • Four fan speed options:Low,Medium,High,Super-high • Anti-mold filter • INVERTER-driven compressors and electronic LEVs provide higher efficiency with controlled power usage • The outdoor unit powers the indoor unit,and should a power outage occur,the system is automatically restarted when power returns • Cooling operation range: 14°F to:115°F • Heating operation range:-4°F to 75°F • Multiple control options available: -Hand-held Remote Controller(provided with unit) -kumo cloud®smart device app for remote access -Third-party interface options -Wired or wireless controllers • 12-hour timer • ECONO COOL mode • AUTO restart • Blue Fin anti-corrosion treatment applied to the outdoor unit heat exchanger for increased coil protection and longer life Specifications are subject to change without notice. ©2019 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. li `SPECIFICATIQNS MSZ I M12NA & MUZ-;HM12NA s. , ,I Maximum Capacity Btu/h 12,200 Rated Capacity Btu/h 12,000 Minimum Capacity Btu/h 3,800 i Maximum Power Input W 1,300 Cooling1 Rated Power Input W 1.210 Moisture',Removal Pints/h 2.5 Sensible Heat Factor 0.77 Power Factor % 95/95 Maximum Capacity Btu/h 14,500 Rated Capacity • Btu/h 12,200 Minimum Capacity Btu/h 4,500 Heating at 47°F2 Maximum Power Input W 1,220 Rated Power Input W 990 1 Power Factor % 93/93 Maximum Capacity Btulh 9,000 Rated Capacity Btulh 7,600 ' Heating at 17°F3 —_..—..._.....__ — -- Maximum Power Input W 990 Rated Power Input _. W 800 — .. ...L.... Maximum Capacity Btulh 7,440 Heating at 5°F4 Maximum Power Input W 820 SEER 18.0 EER1 9.9 HSPF(IV) 10.0 Efficiency — ..._.._...._.... — ........................................._.. — COP at 47°F2 3.61 COP at 17°F in Maximum Capacity3 2.66 COP at 5°F in Maximum Capacity4 2.66 ENERGY STAR°Certified(ENERGY STAR products are third-party certified by an EPA-recognized NO Certification Body.) Voltage,•Phase,Frequency 208/230V, 1 phase,60Hz Guaranteed Voltage Range V AC 187-253 Voltage:Indoor-Outdoor,S1-S2 V AC 208/230• Electrical Voltage:;Indoor-Outdoor,S2-S3 V DC 24 Voltage:Indoor-Remote Controller Wireless Type Recommended Fuse/Breaker Size A 15 Recommended Wire Size(Indoor-Outdoor)...................................................._ ...._......._.......AWG ......._......... 14..._........_..................................................._._ MCA A 1 MOCP A • 15 Blower Motor Full Load Amperage A 0.76 Indoor Unit — .._._... — ............._.. -- ..._.._...Blower Motor Output W 30 • Airflow Rate at Cooling,Dry CFM 399-321-237-170 • Airflow Rate at Cooling,Wet CFM 364-286-201-134 Specifications are subject to change without notice. ©2019 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. • • `SPECIFECA71QNS: MSZ`HM12NA & M,(1Z=HMI2N 4 -Ito, .. Airflow Kate at Heating,Dry CFM 406-321-237-170 • • Sound Pressure Level(Cooling) dB(A) 45-37-30-22 . i Sound Pressure Level(Heating) I dB(A) 43-37-30-22 Drain Pipe Size In.(mm) 5/8(15.88) • i ' i Heat Exchanger Type Plate fin coil • ' 'External Finish Color • Munsell 1.0Y 9.2/0.2 W:In.(mm) 1 31-7/16(798) • Unit Dimensions 1 D:In.(mm) • 9-1/8(232) H:In.(mm) 11-5/8(295)' • W:In.(mm) 33-1/2(850) •i Package Dimensions 1 D:In.(mm) • 12(300) • H:In.(mm) 1 , 14(350) ' • • • •Unit Weight Lbs.(kg) 22(10) Package Weight • Lbs.(kg) 26(11.5) Indoor Unit Operating ,Cooling Intake Air Temp(Maximum/Minimum)* °F 90 DB,73 WB/67 DB,57 WB Temperature Range •Heating Intake Air Temp(Maxinium/Minimum) • °F 80 DB/70 DB ' •MCA A 9 MOCP A 15 Fan Motor Full Load Amperage A 0.5 Fan Motor Output W 55 , • •Airflow Rate CFM • 1,151/1,225 •Refrigerant Control LEV ' •Defrost Method Reverse cycle • Heat Exchanger Type Plate fin coil • • •Sound Pressure Level,Coaling1 • dB(A) 49 ISound Pressure Level;Heating2 • dB(A) 51 !Compressor Type DC INVERTER-driven Twin Rotary • !Compressor Model KNB073FRVMC Outdoor Unit Compressor Rated Load Amps A 6.2 •Compressor Locked Rotor Amps A 7.7 ................. •Compressor Oil Type//Charge oz. FV50S 1/9.1 External Finish Color Munsell 3Y 7.8/1/1 • Base Pan Heater • Optional W:In.(mm) 1 31-1/3(800) Unit Dimensions • D:In.(mm) • 11-1/5(285) • • H:In.(mm) • 21-5/9(550) • W:In.(mm) I 37(940) •• I Package Dimensions I D:In.(mm) I 14-15/16(380) • H:In.(mm) 24-13/16(630) Unit Weight Lbs.(kg) 73(33) •Package Weight Lbs.(kg) I 79(36) I I . Specifications are subject to change without notice. ©2019 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. • z o SPEC F1CATIONS: MSZ-HMI2NA&MtJZ-HMI2NA Cooling Air Tem__. Maximum!Minimum F....._ 1151 14 P(( ) Outdoor Unit Operating Cooling Thermal Lock-out/Re-start Temperatures** 'F -1/3 1 ' Temperature Range Heating Air Temp(Maximum/Minimum) °F 75/-4 Heating Thermal Lock-out!Re-start Temperatures** °F -9/-4 Type • R410A Refrigerant — -- — = i_......_..........._ Charge Lbs,oz 1, 12 Gas Pipe Size O.D.(Flared) In.(mm) 3/8(9.52) Liquid Pipe Size O.D.(Flared) In.(mm) 1/4(6.35) • Piping Maximum Piping Length • Ft.(m) • 65(20) • Maximum Height Difference • Ft.(m) 40(12) Maximum Number of Bends 10 • • Notes ,AHRI Rated Conditions 1Cooling;(Indoor//Outdoor) °F 80 DB,67 WB//95 DB,75 WB d date(Rated at s •2Heating;at 47°F(Indoor//Outdoor) °F 70 DB,60 WB 1147 DB.43 WB determined at a fixed • compressor speed) Heating at 17°F(Indoor//Outdoor) • °F 70 DB,60 WB 1117 DB,15 WB 'Conditions4Heating Heating at 5°F(Indoor//Outdoor) . °F 70 DB,60 WB//-4 DB,-5 WB *Applications should be restricted to comfort cooling only;equipment cooling applications are not recommended for low ambient temperature conditions. • **System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. • ! '1 rr ' I • • Specifications are subject to change without notice. ©2019 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. . ACCESSORIES: MSZ-HM12NA Anti-allergy Enzyme Filter a MAC-408FT-E Backlit,Wall-mounted.Wireless Controller o MHK1 PortableCentral Controller............-------.____._............--.__.__—._....................................._-_.---..__—__.....................--._.._.___..___--.__...____._.._...._.._..._........_..._-----..._._.-o MCCH1.........................._..----....__ L_................._.. Wired MA Controller1 o PAR-33MAA T53..... s. Simple MA Controllers ❑PAC-YT53CRAU Touch MA Controller1 I o PAR-CTO1 MAU-SB Wired Remote Sensor o M21-EAA-307 Wireless Temperature and Humidity Sensor o PAC-USWHS003-TH-1 Outside Air Sensor for MHK1 ❑MOS1 System Control Interfacet o MAC-3331F-E Wireless Interface o PAC-USWHS002-WF-1 Thermostat Interface o PAC-US444CN-1 kumo station o PAC-WHS01 HC-E USNAP Interface ❑PAC-WHSO1UP-E IT Extender a PAC-WHS011E-E BACnet®and MODBUS®Interface a PAC-UKPRC001-CN-1 • Lockdown Bracket for Hand-held Remote Controllers ❑RCMKP1CB { Blue Diamond Sensor Extension Cable-15 Ft. o C13-103 Blue Diamond Alarm Extension Cable-6.5 Ft. o C13-192 Blue Diamond MultiTank—collection tank for use with multiple pumps a C21-014 BlueDiamond Rubber Foot Pads-----......................----------.._._............_._.__.....--------._...................__.._..—.._._....._...._._...................._._._._.__._...—..---......-......_.._....a F10-010 Mini Condensate Pump-230 volt application o SI30-230 • MegaBlue Advanced Blue Diamond Condensate Pump w/Reservoir&Sensor o X87-835-110 to 250V • MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/Reservoir&Sensor(110V)up to 48,000 Btu/h 'o X87-711 -110V [recommended] • Advanced Blue Diamond Mini Condensate Pump w/Reservoir&Sensor(208/230V)[recommended] o X87-721 -208/230V MicroBlue Blue Diamond Mini Condensate Pump(110/2081230V)up to 18,000 Btu/h ❑X85-003 Fascia Kit for MicroBlue Pump—mounts the MicroBlue and sensor directly beneath the indoor unit o T18-016 Drain Pan Level Sensor a DPLS2 (30A/600V/UL)[fits 2"X 4"utility box]-Black a TAZ-MS303 (30A/600V/UL)[fits 2"X 4"utility box]-White o TAZ-MS303W 1 Requires MAC-3331F-E 2 Allows indoor units to connect to an MA Controller • • Specifications are subject to change without notice. ©2019 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. 1 • • j■y ��,� rte/\� ��/■�E{ 7 ° gv�e . a ACRES'pm's: MJZ.HM12Na . . • .. €e.� Air Outlet Guide ❑MAC-881SG Drain Socket o MAC-860DS Optional Defrost Heater o MAC-640BH-U •Hail Guard o HG-B4 Outdoor Unit 3-1/4 inch Mounting Base(Pair)-Plastic o DSD-400P Condensing Unit Mounting Pad 16"x 36"x 3" ❑ULTRILITE1 Outdoor Unit Stand-12"High o QSMS1201M Outdoor Unit Stand—18"High ❑QSMS1801 M Outdoor Unit Stand-24"High ❑QSMS2401M Heavy Duty Wall Mounting Bracket—Coated Steel o QSWB2000M-1 Heavy Duty Wall Mounting Brackett 316 Series Stainless Steel I o QSWBSS 15'x 1/4"x 15'/3/8"Lineset(Twin-Tube Insulation) o MLS143812T-15 • 30'x 1/4"x 30'/3/8"Lineset(Twin-Tube Insulation) o MLS143812T-30 50'x 1/4"x 50'/3/8"Lineset(Twin-Tube Insulation) ❑MLS143812T-50 • 65'x 1/4"x 65'/3/8"Lineset(Twin-Tube Insulation) o MLS143812T-65 • Specifications are subject to change without notice. ©2019 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. • :• DIMENSIONS.- SZ-HM12NA . Unit: inch 1/16x1 Oblong hole 1/16x13/16 Oblong hol1e Installation plate 3-1/8.1 NI.e K8-7/8 ± 8-1/8 L3-I/8 i! • 31-1/16 e1 30 15/16 f4 o — - M11MMil MEW 1 r — v v O / .I I����Il�em■�il I '<6-Il86-I/8, � Iii III���{{���■SII -- N 2-3/8 13-5/16 13-9/16 _ 2.1/8 9-1/8 Air in all hole i3 3116 _Mill..., Indoor unit f1 ' -- - - - ' ' • 1---1 Installation .late I __.4, 4 / 1-3/4 1-15/16 L 24-3/8 �5 I/8� < '�_•_ I ', 1 5/8 -- Drain hose /� 4-3/16,-;,,,!S I II • .2.114 { {{ 11116 _ - - --- . 4-3/: ,! — Air out ,, r., .. _ . _ _ . _ , , Insulation 01-3/80.D II so - c Liquid line 01/4 19-11/16(Flared connection 01/4) ii 7— 1 1 a I I '3/16 Gas line 03/8 16-15/16 f -2-3/16 I-15/16'I1 'a I L (Flared connection:03/8(09112 kBtu/h),01/2(16 kBtu/h)) III r I 3/16 Drain hose Insulation 01-1/8 O.D Connected part 05/B O.D I I. I • I 1 I Specifications are subject to change without notice. ©2019 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. . I I . �DIMENSIONSa•MUZ- HM12N'A Unit: inch, REQUIRED SPACE `1 4 in. or more when front and sides of the unit are clear i 416.pr 11111111111111 p'Iris• \c'..' a°�emote �p�� IIII.illlllllllllllllllllllli IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII r--...--- 1111111 lllllllllllllllllllllllllllll, I. ~' 11' 15-3/4 i�lllllllllliiill � 011,111 v Air�, .�p�� ,.,,I,Illlllllllllq;;.- �� rn Drain hole 01-21/32 „Vile�� •;;!/ill Al-1,0 <.* v Air in tom so o<Dot 4 n'or o I. rlb r@ oN � co.c z1- *2 When any 2 sides of left, right II 1-9/16 so and rear of the unit are clear Air out 2-holes 3/8X13/16 Service lane/ 7/8 11/16 a Handle,— 1 ," 3f- •• • I' i=i4q �` • Liquid refrigerant pipe joint t N Refrigerant pipe(flared)01/4 N , �; �`` -�i� ' 1� rn =�1, Gas refrigerant pipe joint N Ali „,.1 ' ' I u m IRefrigerant pipe(flared)0 3/8(09/12 kBtu/h) N \ "IIIII 01/2(15/18 kBtulh) _ I ---- •••• 1!�Nril;� �, - _ = 11-29/3 ,_ 5-11/32 -15/1 , 19-11/16 6-23/32 1 Bolt pitch for installation- I 31-1/2 „ 2-3/4 i• 1; i • MITSUBISHI Milk ELECTRIC COOLING & HEATING 1340 Satellite Boulevard,Suwanee,GA 30024 Toll Free:800-433-4822 www.mee,hvac.com 1 AMINCEglil v . < .,-.-fi FORM#MSZ-Hh•112NA/MUZ-HM12NA-201902 e. Intertek Specifications are subject to change without notice. 0 2019 Mitsubishi Electric Trane HVAC US LLC.All rights reserved.