NOTICE OF ACCEPTANCE (NOA)
TAMKO Building Products,Inc.
220 West 4`h Street
Joplin,MO 64801
SCOPE: p
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHD).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(in Miami-Dade County) and/or the AHJ (in areas other than Miami-Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High'Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: TAMKO Roof Shingles
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No.15-0709.19 and consists of pages 1 through 6.
The submitted documentation was reviewed by Gaspar J Rodriguez.
MIAMI•DADE CNOA No.: 15-1215.10
OUNTY
Expiration Date: 12/01/20
Approval Date: 05/26/16
Page 1 of 6
{
ROOFING ASSEMBLY APPROVAL
Category Roofmg
Sub-Category: Asphalt Shingles
Materials: Laminate
Deck Type: Wood
SCOPE
This approves TAMKO's Heritage,Heritage Woodgate and Heritage Premium asphalt shingles,manufactured by
TAMKO Building Products,Inc.,as described in this Notice of Acceptance and designed to comply with the Florida
Building Code High Velocity Hurricane Zones.
PRODUCT DESCRIPTION
Product Dimensions Test Product Description
Specifications
Heritage 131/4"x 39'/8" TAS 110 Dimensional asphalt shingle.
Manufacturing Location #1, 2, 3
Heritage Woodgate 131/4"x 39'/8" TAS 110 Dimensional asphalt shingle.
Manufacturing Location #1,3
\Heritage Premium 131/4"x 39'/8" TAS 110 Dimensional asphalt shingle.
Manufacturing Location #1, 2, 3
MANUFACTURING LOCATIONS
1. Dallas,.TX
2. Tuscaloosa,AL
3. Frederick,MD
EVIDENCE SUBMITTED
Test Aeencv Test Identifier Test Name/Revort Date
Underwriters Laboratories,Inc. TAS 107&UL 790 04CA44252 02/25/05
ASTM D3462 02NK33813 09/23/02
ASTM D 3462 &TAS 107 R2919 Letter 03/10/11
ASTM.D3462 4789110543 08/26/14
TAS 107 02/19/15
ASTM E 108 08/26/14
ASTM D3161, Class F 4787043752 10/20/15
PRI Asphalt Technologies,Inc. TAS 100 TAP-129-02-01 05/26/05
TAS 100 TAP-130-02-01 05/26/05
TAS 100 TAP-131-02-01 05/26/05
PRI Construction Materials Technologies LLC TAS 100 TAP-303-02-01 12/12/14
TAS 100 TAP-3'07-02-01 02/10/15
TAS 100 TAP-317-02-01 09/02/15
NOA No.: 15-1215:10
MIAMI-DADE COUNTY
...� , Expiration Date: 12/01/20
Approval Date: 05/26/16
Page 2 of 6
LmTrATIONS
1. .Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. Shingles shall not be installed on roof mean heights in excess of 33 ft.
3. All.products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61G20-3 of the Florida Administrative Code.
INSTALLATION
1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115.
3. The,manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be incompliance with Detail `A',attached.
5. Nailing shall be in compliance with Details V,attached.
LABELING
Shingles shall be permanently labeled with the manufacturer's name and/or logo, city and state of
manufacturing facility, and the following statement: "Miami-Dade County Product Control Approved"or with
-the Miami-Dade County Product Control Seal as seen below:
MIAWDADE COUNTY
BUILDING PERMIT REQUIREMENTS
As required by the Building Official or the applicable Building Code in order to properly evaluate the
installation of this system. This Notice of Acceptance on its own cannot be used to obtain a building permit.
i
i
NOA No.: 15-1215.10
MIAMI•DAD;couNrr Expiration Date: 12/01/20
Approval Date: 05/26/16
Page 3 of 6 -
DETAIL.A
HERITAGE,HERITAGE WOODGATE,AND HERITAGE PREAuum
All dimensions are in inches.
5TH COURSE
4TH COURSE
108"
3RD COURSE
164'
2ND COURSE
23
1ST COURSE
29
Full
DETAIL B
HERITAGE SHINGLE
FIG. I FASTENING PATTERN
All dimensions are in inches
1" I 7'/2" I 7'/Z" I 7 3/6" 7'/z" 7'/Z" 11" 13-1l4"
c
------------------------
--- -------------- -
ExE_��sure
NOA No.: 15-1215.10
MIAMI-DAD:COUNTY Expiration Date: 12/01/20
Approval Date: 05/26/16
Page 4 of 6
DETAIL B (CONTINUED)
HERITAGE SHINGLE
FIG. 2 ALTERNATE FASTENING PATTERN
0 Common Bend
- --- -R.1.5TFNFR; --- - --
- IP t► 1 •Iy
LC
• 39-3,85'
HERITAGE SHINGLE
(TUSCALOOSA,AL)
FIG 3 ALTERNATE FASTENING PATTERN
HORIZONTAL NAIL SPACING IN ACCORDANCE WITH FIG.1 OR FIG.2.
VERTICAL NAIL SPACING ALLOWED ANYWHERE WITHIN NAIL ZONE.
PAINT
LINE-
7-718"
INE-7-7:8" NAIL ZONE
-EDGE OF
COMMON
Y 1 BOND
EXPOSURE
5-5/8"
ACCEPTABLE
---- --- FASTENER LOCATION
DO NOT FASTEN
`ALONG EDGE OF
----------------------�`- COMMON BOND
�7
- PREFERRED
FASTENER
LOCATION
NOA No.: 15-1215.10
MIAMI-RADE COUNTY Expiration Date: 12/01/20
Approval Date: 05/26/16
Page 5 of 6
r
a
HERITAGE WOODGATE &HERITAGE PRENIIUM SHINGLES
FIG. 4 FASTENING PATTERN
All dimensions are in inches
39-3/8"
1' 7Y2" 6Y2" 9 3/8" 6%" 7Y27 1" „
<>> <> <�I< >I< >IH
c -------------- -- ------------'--- ---------
— ------------------------------------------------------------------------------------
6"
5-5'/
ExE_yr-)si.ne
END OF THIS ACCEPTANCE
NOA No.: 15-1215.10
MIAMI•DAD;couNTY Expiration Date: 12/01/20
Approval Date: 05/26/16
Page 6 of 6
T.
MIAMI•DADE
-_ MIAMI-DADE COUNTY
- PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
T(786)3152590 F.(786)315-2599
NOTICE OF ACCEPTANCE (NOA)
TAMKO Building Products,Inc.
220 W. 4th Street
Joplin,MO 64801
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section
(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product
or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: TAMKO Synthetic Guard'and Synthetic Guard'Plus Roof Underlayment
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
'TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for
sales, advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA.number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA consists of pages 1 through 4.
The submitted documentation was reviewed by Freddy Semino
J
NOA No.: 17-1030.03
MIAMI•DAD;couNTY Expiration Date: 02/21/24
Approval Date: 02/21/19
Page 1 of 4
ROOFING COMPONENT APPROVAL
Cateeory• Roofmg
Sub-CateLyorv: Underlayment
Material: Polypropylene
SCOPE:
This approves TAMKO Synthetic Guard"' and Synthetic Guard' Plus Roof Underlayment as described in
this Notice of Acceptance; designed to comply with the Florida Building Code including the High Velocity Hurricane
Zone of the Florida Building Code.
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Test Product
Product Dimensions Specification Description
TAMKO Synthetic 48.1"x 250.5' ASTM D226 Non-woven synthetic underlayment with a black
Guard`"`Underlayment rolls Type II coated polypropylene spun bond fabric surface.A
polypropylene 5x5 scrim, and a black backside
coating.
TAMKO Synthetic 48.1"x 250.5' ASTM D226 Non-woven synthetic underlayment with a grey
Guard""Plus Roof rolls Type H coated polypropylene spun bond fabric surface.A
Underlayment polypropylene 10x5 scrim, and a grey backside
coating.
MANUFACTURING LOCATION:
1. M.L.#1
EVIDENCE SUBMITTED:
Test ALency Test Identifier Test Name/Reyort Date
PRI Construction Material TAP-393-02-01 ASTM D 226 09/27/2017
Technologies Type H
TAP-394-02-01 ASTM D 226 09/27/2017
Type][[
INSTALLATION SPECIFICATIONS: (Single Layer: Slopes of 2:12 or greater)
L TAMKO Synthetic Guard"and Synthetic Guard'"Plus Roof Underlayment Roof Underlayment shall be
installed in strict compliance with applicable Building Code.
2. TAMKO Synthetic Guard'"and Synthetic Guarr Plus Roof Underlayment shall be installed with a
minimum 4-inch horizontal lap and 6-inch vertical laps in a shingle layer fashion. Vertical laps in a
succeeding course shall be staggered from those in preceding course by minimum 6-feet.
3. TAMKO Synthetic Guarr and Synthetic Guard's Plus Roof Underlayment shall be fastened with
approved roofmg nails and tin-caps spaced 6"o.c. at all laps and staggered rows fastened 12"o.c.in a grid
pattern in the field of the roll between the overlaps.
NOA No.: 17-1030.03
MIAMI•DAD;couNTY Expiration Date: 02/21/24
Approval Date: 02/21/19
Page 2 of 4
4. TAMKO Synthetic Guard""and Synthetic Guard''Plus Roof Underlayment may be used with Asphaltic
shingles, Wood shakes and shingles,Non-structural metal roofing, and quarry slate.
5. For fire classification of specific roof assemblies using TAMKO Synthetic Guard's and Synthetic Guarr
Plus Roof Underlayment refer to a current Approved Roofing Materials Directory for fire ratings of this
product.
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Oficial or applicable building code in order to properly evaluate
the installation of this material.
LE IITATIONS:
1. Fire classification is not part of this acceptance;refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code.
3. TAMKO Synthetic Guard'"`and Synthetic Guard Plus Roof Underlayment shall be applied to a smooth,
clean and dry surface with deck free of irregularities.All nails in the deck shall be carefully checked for
protruding heads. Re-fasten any loose decking panels. Sweep the deck thoroughly to remove any dust and
debris prior to application.
4. TAMKO Synthetic Guard'and Synthetic Guard"'Plus Roof Underlayment shall not be hot mopped,
refer to manufacturer's published literature for product compatibility, additional installation recomendations,
product safety guidelines and instructions.
5. TAMKO Synthetic GuardTM and Synthetic GuardTm Plus Roof Underlayment shall not be applied over an
existing roof membrane as a recover system.
6. TAMKO Synthetic Guard'``and Synthetic GuardTM Plus Roof Underlayment shall not be left exposed as a
temporary roof for longer than 30 days of application.
7. TAMKO Synthetic Guard'"and Synthetic Guard"'Plus Roof Underlayment are components used in roof
system assemblies.Roof system assemblies are approved under a specific Notice of Acceptance.Refer to
Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with specific
prepared roofing products.
8. TAMKO Synthetic Guare and Synthetic Guarr Plus Roof Underlayment may be used with any
approved roof covering Notice of Acceptance listing TAMKO Synthetic Guard'and Synthetic GuardTM
Plus Roof Underlayment as a component part of an assembly in the Notice of Acceptance. If TAMKO
Synthetic GuardTM and Synthetic GuardTM Plus Roof Underlayment are not listed,a request may be made
to the Authority Having Jurisdiction(AHJ)or the Miami-Dade County Product Control Department for
approval provided that appropriate documentation is provided to detail compatibility of the products,wind
uplift resistance,and fire testing results.
NOA No.: 17-1030.03
MIAMI•DAD;couNTY Expiration Date: 02/21/24
Approval Date: 02/21/19
Page 3 of 4
a
: w
9. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
10. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo,
city, state and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade
County Product Control Seal as shown below.
MIAMI•DADE COUNTY
END OF THIS ACCEPTANCE
NOA No.: 17-1030.03
MIAMI-DAOE C0 j Expiration Date: 02/21/24
Approval Date: 02/21/19
Page 4 of 4