Loading...
HomeMy WebLinkAboutProduct Approval z MIAMI-DADE MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) TAMKO Building Products,Inc. 220 West 4`h Street Joplin,MO 64801 SCOPE: p This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHD). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (in Miami-Dade County) and/or the AHJ (in areas other than Miami-Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High'Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: TAMKO Roof Shingles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No.15-0709.19 and consists of pages 1 through 6. The submitted documentation was reviewed by Gaspar J Rodriguez. MIAMI•DADE CNOA No.: 15-1215.10 OUNTY Expiration Date: 12/01/20 Approval Date: 05/26/16 Page 1 of 6 { ROOFING ASSEMBLY APPROVAL Category Roofmg Sub-Category: Asphalt Shingles Materials: Laminate Deck Type: Wood SCOPE This approves TAMKO's Heritage,Heritage Woodgate and Heritage Premium asphalt shingles,manufactured by TAMKO Building Products,Inc.,as described in this Notice of Acceptance and designed to comply with the Florida Building Code High Velocity Hurricane Zones. PRODUCT DESCRIPTION Product Dimensions Test Product Description Specifications Heritage 131/4"x 39'/8" TAS 110 Dimensional asphalt shingle. Manufacturing Location #1, 2, 3 Heritage Woodgate 131/4"x 39'/8" TAS 110 Dimensional asphalt shingle. Manufacturing Location #1,3 \Heritage Premium 131/4"x 39'/8" TAS 110 Dimensional asphalt shingle. Manufacturing Location #1, 2, 3 MANUFACTURING LOCATIONS 1. Dallas,.TX 2. Tuscaloosa,AL 3. Frederick,MD EVIDENCE SUBMITTED Test Aeencv Test Identifier Test Name/Revort Date Underwriters Laboratories,Inc. TAS 107&UL 790 04CA44252 02/25/05 ASTM D3462 02NK33813 09/23/02 ASTM D 3462 &TAS 107 R2919 Letter 03/10/11 ASTM.D3462 4789110543 08/26/14 TAS 107 02/19/15 ASTM E 108 08/26/14 ASTM D3161, Class F 4787043752 10/20/15 PRI Asphalt Technologies,Inc. TAS 100 TAP-129-02-01 05/26/05 TAS 100 TAP-130-02-01 05/26/05 TAS 100 TAP-131-02-01 05/26/05 PRI Construction Materials Technologies LLC TAS 100 TAP-303-02-01 12/12/14 TAS 100 TAP-3'07-02-01 02/10/15 TAS 100 TAP-317-02-01 09/02/15 NOA No.: 15-1215:10 MIAMI-DADE COUNTY ...� , Expiration Date: 12/01/20 Approval Date: 05/26/16 Page 2 of 6 LmTrATIONS 1. .Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shingles shall not be installed on roof mean heights in excess of 33 ft. 3. All.products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. INSTALLATION 1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115. 3. The,manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be incompliance with Detail `A',attached. 5. Nailing shall be in compliance with Details V,attached. LABELING Shingles shall be permanently labeled with the manufacturer's name and/or logo, city and state of manufacturing facility, and the following statement: "Miami-Dade County Product Control Approved"or with -the Miami-Dade County Product Control Seal as seen below: MIAWDADE COUNTY BUILDING PERMIT REQUIREMENTS As required by the Building Official or the applicable Building Code in order to properly evaluate the installation of this system. This Notice of Acceptance on its own cannot be used to obtain a building permit. i i NOA No.: 15-1215.10 MIAMI•DAD;couNrr Expiration Date: 12/01/20 Approval Date: 05/26/16 Page 3 of 6 - DETAIL.A HERITAGE,HERITAGE WOODGATE,AND HERITAGE PREAuum All dimensions are in inches. 5TH COURSE 4TH COURSE 108" 3RD COURSE 164' 2ND COURSE 23 1ST COURSE 29 Full DETAIL B HERITAGE SHINGLE FIG. I FASTENING PATTERN All dimensions are in inches 1" I 7'/2" I 7'/Z" I 7 3/6" 7'/z" 7'/Z" 11" 13-1l4" c ------------------------ --- -------------- - ExE_��sure NOA No.: 15-1215.10 MIAMI-DAD:COUNTY Expiration Date: 12/01/20 Approval Date: 05/26/16 Page 4 of 6 DETAIL B (CONTINUED) HERITAGE SHINGLE FIG. 2 ALTERNATE FASTENING PATTERN 0 Common Bend - --- -R.1.5TFNFR; --- - -- - IP t► 1 •Iy LC • 39-3,85' HERITAGE SHINGLE (TUSCALOOSA,AL) FIG 3 ALTERNATE FASTENING PATTERN HORIZONTAL NAIL SPACING IN ACCORDANCE WITH FIG.1 OR FIG.2. VERTICAL NAIL SPACING ALLOWED ANYWHERE WITHIN NAIL ZONE. PAINT LINE- 7-718" INE-7-7:8" NAIL ZONE -EDGE OF COMMON Y 1 BOND EXPOSURE 5-5/8" ACCEPTABLE ---- --- FASTENER LOCATION DO NOT FASTEN `ALONG EDGE OF ----------------------�`- COMMON BOND �7 - PREFERRED FASTENER LOCATION NOA No.: 15-1215.10 MIAMI-RADE COUNTY Expiration Date: 12/01/20 Approval Date: 05/26/16 Page 5 of 6 r a HERITAGE WOODGATE &HERITAGE PRENIIUM SHINGLES FIG. 4 FASTENING PATTERN All dimensions are in inches 39-3/8" 1' 7Y2" 6Y2" 9 3/8" 6%" 7Y27 1" „ <>> <> <�I< >I< >IH c -------------- -- ------------'--- --------- — ------------------------------------------------------------------------------------ 6" 5-5'/ ExE_yr-)si.ne END OF THIS ACCEPTANCE NOA No.: 15-1215.10 MIAMI•DAD;couNTY Expiration Date: 12/01/20 Approval Date: 05/26/16 Page 6 of 6 T. MIAMI•DADE -_ MIAMI-DADE COUNTY - PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)3152590 F.(786)315-2599 NOTICE OF ACCEPTANCE (NOA) TAMKO Building Products,Inc. 220 W. 4th Street Joplin,MO 64801 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: TAMKO Synthetic Guard'and Synthetic Guard'Plus Roof Underlayment LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. 'TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales, advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA.number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA consists of pages 1 through 4. The submitted documentation was reviewed by Freddy Semino J NOA No.: 17-1030.03 MIAMI•DAD;couNTY Expiration Date: 02/21/24 Approval Date: 02/21/19 Page 1 of 4 ROOFING COMPONENT APPROVAL Cateeory• Roofmg Sub-CateLyorv: Underlayment Material: Polypropylene SCOPE: This approves TAMKO Synthetic Guard"' and Synthetic Guard' Plus Roof Underlayment as described in this Notice of Acceptance; designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Test Product Product Dimensions Specification Description TAMKO Synthetic 48.1"x 250.5' ASTM D226 Non-woven synthetic underlayment with a black Guard`"`Underlayment rolls Type II coated polypropylene spun bond fabric surface.A polypropylene 5x5 scrim, and a black backside coating. TAMKO Synthetic 48.1"x 250.5' ASTM D226 Non-woven synthetic underlayment with a grey Guard""Plus Roof rolls Type H coated polypropylene spun bond fabric surface.A Underlayment polypropylene 10x5 scrim, and a grey backside coating. MANUFACTURING LOCATION: 1. M.L.#1 EVIDENCE SUBMITTED: Test ALency Test Identifier Test Name/Reyort Date PRI Construction Material TAP-393-02-01 ASTM D 226 09/27/2017 Technologies Type H TAP-394-02-01 ASTM D 226 09/27/2017 Type][[ INSTALLATION SPECIFICATIONS: (Single Layer: Slopes of 2:12 or greater) L TAMKO Synthetic Guard"and Synthetic Guard'"Plus Roof Underlayment Roof Underlayment shall be installed in strict compliance with applicable Building Code. 2. TAMKO Synthetic Guard'"and Synthetic Guarr Plus Roof Underlayment shall be installed with a minimum 4-inch horizontal lap and 6-inch vertical laps in a shingle layer fashion. Vertical laps in a succeeding course shall be staggered from those in preceding course by minimum 6-feet. 3. TAMKO Synthetic Guarr and Synthetic Guard's Plus Roof Underlayment shall be fastened with approved roofmg nails and tin-caps spaced 6"o.c. at all laps and staggered rows fastened 12"o.c.in a grid pattern in the field of the roll between the overlaps. NOA No.: 17-1030.03 MIAMI•DAD;couNTY Expiration Date: 02/21/24 Approval Date: 02/21/19 Page 2 of 4 4. TAMKO Synthetic Guard""and Synthetic Guard''Plus Roof Underlayment may be used with Asphaltic shingles, Wood shakes and shingles,Non-structural metal roofing, and quarry slate. 5. For fire classification of specific roof assemblies using TAMKO Synthetic Guard's and Synthetic Guarr Plus Roof Underlayment refer to a current Approved Roofing Materials Directory for fire ratings of this product. BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Oficial or applicable building code in order to properly evaluate the installation of this material. LE IITATIONS: 1. Fire classification is not part of this acceptance;refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. 3. TAMKO Synthetic Guard'"`and Synthetic Guard Plus Roof Underlayment shall be applied to a smooth, clean and dry surface with deck free of irregularities.All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose decking panels. Sweep the deck thoroughly to remove any dust and debris prior to application. 4. TAMKO Synthetic Guard'and Synthetic Guard"'Plus Roof Underlayment shall not be hot mopped, refer to manufacturer's published literature for product compatibility, additional installation recomendations, product safety guidelines and instructions. 5. TAMKO Synthetic GuardTM and Synthetic GuardTm Plus Roof Underlayment shall not be applied over an existing roof membrane as a recover system. 6. TAMKO Synthetic Guard'``and Synthetic GuardTM Plus Roof Underlayment shall not be left exposed as a temporary roof for longer than 30 days of application. 7. TAMKO Synthetic Guard'"and Synthetic Guard"'Plus Roof Underlayment are components used in roof system assemblies.Roof system assemblies are approved under a specific Notice of Acceptance.Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. 8. TAMKO Synthetic Guare and Synthetic Guarr Plus Roof Underlayment may be used with any approved roof covering Notice of Acceptance listing TAMKO Synthetic Guard'and Synthetic GuardTM Plus Roof Underlayment as a component part of an assembly in the Notice of Acceptance. If TAMKO Synthetic GuardTM and Synthetic GuardTM Plus Roof Underlayment are not listed,a request may be made to the Authority Having Jurisdiction(AHJ)or the Miami-Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products,wind uplift resistance,and fire testing results. NOA No.: 17-1030.03 MIAMI•DAD;couNTY Expiration Date: 02/21/24 Approval Date: 02/21/19 Page 3 of 4 a : w 9. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. 10. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city, state and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. MIAMI•DADE COUNTY END OF THIS ACCEPTANCE NOA No.: 17-1030.03 MIAMI-DAOE C0 j Expiration Date: 02/21/24 Approval Date: 02/21/19 Page 4 of 4