HomeMy WebLinkAboutEVALUATION REPORT
NEMO|etc.
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203) 262-9245
ENGINEER EVALUATE TEST CONSULT CERTIFY
EVALUATION REPORT
CertainTeed Corporation
20 Moores Road
Malvern, PA 19355
(610) 651-5847
Evaluation Report 3532.09.05-R14
FL5444-R13
Date of Issuance: 09/22/2005
Revision 14: 01/24/2018
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein.
DESCRIPTION: CertainTeed Asphalt Roof Shingles.
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein
and FBC 1507.2.7.1 / R905.2.6.1
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of t his
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s), the Quality Assurance or the production facility location(s). NEMO|etc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words “NEMO|etc. Evaluated” may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 13.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized by Robert
Nieminen, P.E. on 01/24/2018. This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO|etc. does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO|etc. is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval proc ess of the
product.
5. This is a building code evaluation. Neither NEMO|etc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3532.09.05-R14
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL5444-R13
CertainTeed Asphalt Roof Shingles; (610) 651-5847 Revision 14: 01/24/2018
Page 2 of 13
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: CertainTeed Asphalt Roof Shingles, as produced by CertainTeed Corporation, have
demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code and 6th Edition
(2017) Florida Building Code, Residential Volume through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein .
2. STANDARDS:
Section Property Standard Year
1507.2.5, R905.2.4 Physical Properties ASTM D3462 2010
1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2016
1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158 2011
3. REFERENCES:
Entity Examination Reference Date
UL (TST 1740) ASTM D3161 94NK9632 05/15/1998
UL (TST 1740) ASTM D3161 99NK26506 11/23/1999
UL (TST 1740) ASTM D3161 03CA12702 05/27/2003
UL (TST 1740) ASTM D3161 03CA12702 06/16/2003
UL (TST 1740) ASTM D3161 03NK29847 10/03/2003
UL (TST 1740) ASTM D3161 04CA11329 05/24/2004
UL (TST 1740) ASTM D3161 04CA32986 12/03/2004
UL (TST 1740) ASTM D3161 05NK07049 04/15/2005
UL (TST 1740) ASTM D3161 05NK16778 05/12/2005
UL (TST 1740) ASTM D3161 05CA16778 05/12/2005
UL (TST 1740) ASTM D3161 05NK14836 05/22/2005
UL (TST 1740) ASTM D3161 05NK22800 06/22/2005
UL (TST 1740) ASTM D3462 R684 09/21/2005
UL (TST 1740) ASTM D7158 05NK08037 06/28/2006
UL (TST 1740) ASTM D3161 & D3462 09CA28873 07/23/2009
UL (TST 1740) ASTM D3462 10CA41303 10/07/2010
UL (TST 1740) ASTM D3161 10CA41303 10/08/2010
UL (TST 1740) ASTM D7158 10CA41303 10/27/2010
UL (TST 1740) ASTM D3161 & D3462 10CA44960 11/11/2010
UL LLC (TST 9628) ASTM D3161, D3462 & D7158 13CA32897 11/21/2013
UL LLC (TST 9628) ASTM D3161, D3462 TFWZ.R684 04/22/2014
UL LLC (TST 9628) ASTM D7158 TGAH.R684 04/22/2014
UL LLC (TST 9628) ASTM D3161 & D3462 4786334434 09/16/2014
UL LLC (TST 9628) ASTM D3161 & D3462 4786570826 02/12/2015
UL LLC (TST 9628) ASTM D3161, D3462 & D7158 4786570717 12/16/2015
UL LLC (TST 9628) ASTM D3161 & D3462 4787195678 02/09/2016
UL LLC (TST 9628) ASTM D3161, D3462 & D7158 4787380356 10/26/2016
UL LLC (TST 9628) ASTM D3462 4787380357 10/13/2016
UL LLC (TST 9628) ASTM D7158 4787380357 11/08/2016
UL LLC (TST 9628) ASTM D3161 4787380357 11/09/2016
UL LLC (TST 9628) ASTM D3161, D3462 & D7158 4787586427 01/25/2017
UL LLC (TST 9628) ASTM D3161 & D3462 4788042412 11/15/2017
UL LLC (QUA 9625) Quality Control Service Confirmation Exp. 03/09/2020
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3532.09.05-R14
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL5444-R13
CertainTeed Asphalt Roof Shingles; (610) 651-5847 Revision 14: 01/24/2018
Page 3 of 13
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 CT20™, XT™ 25, XT™ 30 and XT™ 30 IR are fiberglass reinforced, 3-tab asphalt roof shingles.
4.1.2 Arcadia™, Belmont®, Belmont® IR, Carriage House Shangle®, Grand Manor Shangle®, Landmark™,
Landmark™ IR, Landmark™ Pro, Landmark™ Premium, Landmark™ TL, Landmark™ Solaris and
Landmark™ Solaris IR are fiberglass reinforced, laminated asphalt roof shingles.
4.1.3 NorthGate™ is a fiberglass reinforced, laminated, SBS modified bitumen roof shingle.
4.1.4 Presidential Shake™, Presidential Shake™ IR, Presidential Shake TL™ and Presidential Solaris™ are
fiberglass reinforced, architectural asphalt roof shingles.
4.1.5 Hatteras™, Highland Slate™ and Highland Slate™ IR are fiberglass reinforced, 4-tab asphalt roof shingles.
4.1.6 Patriot™ is a fiberglass reinforced asphalt roof strip-shingle (with no cut-outs) providing a laminated
appearance through an intermittent shadow line with contrasting blend drops for color definition.
4.2 Hip & Ridge Shingles:
4.2.1 Presidential Accessory, Accessory for Hatteras, Shangle Ridge™, Shadow Ridge™, Cedar Crest™, Cedar
Crest™ IR, NorthGate Ridge and NorthGate Accessory are fiberglass reinforced accessory shingles for hip
and ridge installation.
4.3 Accessory Starter Strips:
4.3.1 SwiftStart® Starter Shingle is a starter strip for asphalt roof shingles. Its overall size of 15-1/4” x 38-3/4”
yields two (2) 7-5/8” x 38-3/4” starter pieces per shingle.
4.4 Any of the above listed shingles may be produced in AR (algae resistant) versions.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither NEMO|etc. nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use within FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Mate rials
Directory for fire ratings of this product.
5.4 Wind Classification:
5.4.1 All shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM
D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for us in all wind zones
up to Vasd = 150 mph (Vult = 194 mph). Refer to Section 6 for installation requirements to meet this wind
rating.
5.4.2 Presidential Accessory, Accessory for Hatteras, Shangle Ridge, Shadow Ridge, Cedar Crest, No rthGate
Ridge and NorthGate Accessory hip & ridge shingles have been evaluated in accordance with ASTM
D3161, Class F. All except NorthGate Ridge and NorthGate Accessory require use of BASF Sonolastic NP 1
adhesive or Henkel PL® Polyurethane Roof & Flashing Sealant, applied as specified in manufacturer's
application instructions, for use in wind zones up to V asd = 150 mph (Vult = 194 mph). Refer to Section 6 for
installation requirements to meet this wind rating.
5.4.3 SwiftStart® Starter Shingle has been evaluated in accordance with ASTM D3161, Class F. Refer to Section 6
for installation requirements to meet this wind rating.
5.4.4 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less.
Calculations by a qualified design professional are required for conditions outside these limitations.
Contact the shingle manufacturer for data specific to each shingle.
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3532.09.05-R14
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL5444-R13
CertainTeed Asphalt Roof Shingles; (610) 651-5847 Revision 14: 01/24/2018
Page 4 of 13
5.4.4.1 Analysis in accordance with ASTM D7158 indicates the measured uplift resistance (RT) for the CertainTeed
asphalt Roof shingles listed in Section 4.1 through 4.6 (except Presidential Solaris™) exceeds the calculated
uplift force (FT) at a maximum design wind speed of Vasd = 150 mph (Vult = 194 mph) for residential
buildings located in Exposure D conditions with no topographical variations (flat terrain) having a mean
roof height less than or equal to 60 feet. The shingles are permissible under Code for installation in these
conditions using the installation procedures detailed in this Evaluation Report and CertainTeed minimum
requirements, subject to minimum codified fastening requirements established within any local
jurisdiction, which shall take precedence.
5.5 All products in the roof assembly shall have quality assurance audits in accordance with FAC Rule 61G20-3.
6. INSTALLATION:
6.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle
manufacturer’s minimum requirements.
6.1.1 Underlayment shall be acceptable to CertainTeed Corporation and shall hold current Florida Statewide
Product Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or
R905.2.3.
6.2 Installation of asphalt shingles shall comply with the CertainTeed Corporation current published
instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or Section R905.2.6
and the minimum requirements herein.
6.2.1 Fasteners shall be in accordance with manufacturer’s published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.2 Where the roof slope exceeds 21 units vertical in 12 units horizontal, use the “Steep Slope” directions.
6.3 CertainTeed asphalt shingles are acceptable for use in reroof (tear -off) or recover applications, subject to the
limitations set forth in FBC Section 1511 or R908 and CertainTeed published installation instructions.
6.4 SWIFTSTART® STARTER SHINGLE:
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3532.09.05-R14
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL5444-R13
CertainTeed Asphalt Roof Shingles; (610) 651-5847 Revision 14: 01/24/2018
Page 5 of 13
6.5 CT20™, XT™ 25, XT™ 30, XT™ 30 IR:
6.5.1 Hip & Ridge for CT20™, XT™ 25, XT™ 30, XT™ 30 IR: Cut Shingles
6.5.1.1 For ASTM D3161, Class F performance use BASF “Sonolastic® NP1™” adhesive or Henkel “PL®
Polyurethane Roof & Flashing Sealant”, in accordance with CertainTeed requirements.
6.6 ARCADIA™:
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3532.09.05-R14
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL5444-R13
CertainTeed Asphalt Roof Shingles; (610) 651-5847 Revision 14: 01/24/2018
Page 6 of 13
6.6.1 Hip & Ridge for Arcadia™: Cedar Crest™, Cedar Crest™ IR
Use two (2), minimum 1¾-inch long fasteners per shingle. For the starter shingle, place fastener 1 -inch
from each side edge and about 2-inch up from the starter shingle’s exposed butt edge, ensuring minimum
¾-inch embedment into the deck, or full penetration through the deck . For each full Cedar Crest shingle,
place fasteners 8-5/8-inch up from its exposed butt edge and 1-inch from each side edge.
For ASTM D3161, Class F performance use BASF “Sonolastic® NP1™” adhesive or Henkel “PL®
Polyurethane Roof & Flashing Sealant”, in accordance with CertainTeed requirements, to hand-seal
Cedar Crest shingles. Apply NP 1 or PL adhesive from the middle of the shingle’s raised overlay on the
top piece and extending approximately 4-inch along the sides of the headlap along a line ¾ to 1-inch from
each side of the shingle’s headlap. Immediately align and apply the overlying shingle, gently pressing tab
sides into the adhesive, and install nails. To secure the other side, apply a 1-inch diameter spot of NP 1 or
PL adhesive between the shingle layers.
6.7 BELMONT® OR BELMONT® IR:
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3532.09.05-R14
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL5444-R13
CertainTeed Asphalt Roof Shingles; (610) 651-5847 Revision 14: 01/24/2018
Page 7 of 13
6.7.1 Hip & Ridge for Belmont® or Belmont® IR:
6.7.1.1 Option 1: For Belmont®, refer to instructions herein for Cedar Crest™ or Cedar Crest™ IR hip and ridge
shingles. For Belmont® IR, refer to instructions herein for Cedar Crest™ IR hip and ridge shingles.
6.7.1.2 Option 2: For Belmont®: Shangle® Ridge
6.7.1.3 For ASTM D3161, Class F performance use BASF “Sonolastic® NP1™” adhesive or Henkel “PL®
Polyurethane Roof & Flashing Sealant”, in accordance with CertainTeed requirements.
6.8 CARRIAGE HOUSE SHANGLE® AND GRAND MANOR SHANGLE®:
6.8.1 Hip & Ridge for Carriage House Shangle® and Grand Manor Shangle: Refer to instructions herein for
Shangle® Ridge hip and ridge shingles
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3532.09.05-R14
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL5444-R13
CertainTeed Asphalt Roof Shingles; (610) 651-5847 Revision 14: 01/24/2018
Page 8 of 13
6.9 LANDMARK™, LANDMARK™ IR, LANDMARK™ PRO, LANDMARK™ PREMIUM, LANDMARK™ TL, LANDMARK™ SOLARIS,
LANDMARK™ SOLARIS IR, NORTHGATE:
NorthGate:
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3532.09.05-R14
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL5444-R13
CertainTeed Asphalt Roof Shingles; (610) 651-5847 Revision 14: 01/24/2018
Page 9 of 13
NorthGate:
6.9.1 Hip & Ridge for Landmark™, Landmark™ IR, Landmark™ Pro, Landmark™ Premium, Landmark™ TL,
Landmark™ Solaris, Landmark™ Solaris IR, NorthGate:
6.9.1.1 Option 1: Shadow Ridge™ or NothGate Accessory
Shadow Ridge™
Shadow Ridge™
NorthGate Ridge
NorthGate Accessory
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3532.09.05-R14
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL5444-R13
CertainTeed Asphalt Roof Shingles; (610) 651-5847 Revision 14: 01/24/2018
Page 10 of 13
6.9.1.2 For ASTM D3161, Class F performance use BASF “Sonolastic® NP1™” adhesive or Henkel “PL®
Polyurethane Roof & Flashing Sealant”, in accordance with CertainTeed requirements.
6.9.1.3 Option 2: Refer to instructions herein for Cedar Crest™, Cedar Crest™ IR hip and ridge shingles.
6.10 PRESIDENTIAL SHAKE™, PRESIDENTIAL SHAKE™ IR, PRESIDENTIAL SHAKE TL™, PRESIDENTIAL SOLARIS™:
6.10.1 Hip & Ridge for Presidential Shake™, Presidential Shake™ IR, Presidential Shake TL™, Presidential
Solaris™:
6.10.1.1 Option 1: Presidential Accessory
6.10.1.2 For ASTM D3161, Class F performance use BASF “Sonolastic® NP1™” adhesive or Henkel “PL®
Polyurethane Roof & Flashing Sealant”, in accordance with CertainTeed requirements.
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3532.09.05-R14
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL5444-R13
CertainTeed Asphalt Roof Shingles; (610) 651-5847 Revision 14: 01/24/2018
Page 11 of 13
6.10.1.3 Option 2: Refer to instructions herein for Cedar Crest™, Cedar Crest™ IR hip and ridge shingles.
6.11 HATTERAS™:
6.11.1 Hip & Ridge for Hatteras™:
6.11.1.1 Option 1: Accessory for Hatteras
6.11.1.2 Option 2: Cut Hatteras Shingles
6.11.1.3 For ASTM D3161, Class F performance use BASF “Sonolastic® NP1™” adhesive or Henkel “PL® Polyurethane
Roof & Flashing Sealant”, in accordance with CertainTeed requirements.
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3532.09.05-R14
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL5444-R13
CertainTeed Asphalt Roof Shingles; (610) 651-5847 Revision 14: 01/24/2018
Page 12 of 13
6.12 HIGHLAND SLATE™, HIGHLAND SLATE™ IR:
6.12.1 Hip & Ridge for Highland Slate™, Highland Slate™ IR: Refer to instructions herein for Cedar Crest™, Cedar
Crest™ IR or Shangle Ridge™ hip and ridge shingles.
6.13 PATRIOT™:
6.13.1 Hip & Ridge for Patriot™: Refer to instructions herein for Cedar Crest™, Cedar Crest™ IR, Shadow Ridge™,
NorthGate or Shangle Ridge™ hip and ridge shingles.
7. LABELING:
7.1 Each unit shall bear a permanent label with the manufacturer’s name, logo, city, state an d logo of the
Accredited Quality Assurance Agency noted herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table
1507.2.7.1 / R905.2.6.1.
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3532.09.05-R14
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL5444-R13
CertainTeed Asphalt Roof Shingles; (610) 651-5847 Revision 14: 01/24/2018
Page 13 of 13
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this
product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC – QUA9625; (414) 248-6409; karen.buchmann@us.ul.com
- END OF EVALUATION REPORT -