HomeMy WebLinkAboutProduct Approval (2) ` -� �.���ir p�.fl l,, �i,f �a,x:B?flea �'•.s{ ,'p�! i,,�4��y'�'� s"r �� k� 3 ,' e�,... ii .:'7• �t
BCIS Home { Log In € User Registration Hot Topics Submit Surcharge Stats&facts 1 Publications { Contact Us t BM Ste Map Links +
} i Product Approval
":USER:Public User
RECEIVED
Product Approval Menu>Prod ct or Application Search>Application List>Application Detail
kuS APR 0 9 2019
EMIL16092-R5
Application Type ST. Lucie County,._Pe_....�rOlWng_ Re
vision
Code Version 2017
Application Status Approved
Comments
Archived E)
Product Manufacturer Wincore Window Company, LLC
Address/Phone/Email 250 Staunton Avenue
Parkersburg,WV 26104
(304)485-7460 Ext 228
mreed@wincorewindows.com
Authorized Signature Vivian Wright
rickw@rwbldgconsultants.com
Technical Representative Mike Reed
Address/Phone/Email 250 Staunton Tumpike
Parkersburg,WV 26104
(304)485-7460 Ext 228
mreed@wincorewindows.com
Quality Assurance Representative Mike Reed
Address/Phone/Email 250 Staunton Turnpike
Parkersburg,WV 26104
(304)485-7460 Ext 228
0 mreed@wincorewindows.com
Category Windows
UjSubcategory Horizontal Slider
Compliance Method Evaluation Report from a Florida Rhe ' ereArchitect or a Licensed
Professional'Engineer
Nftaq G Evaluation Report-Hardcopy Received
Florida.Engineer or Architect Name who developed-the Lyndon F.Schmidt,P.E.
Evaluation Report
Florida License PE-43409
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2019
Validated By Ryan 1. King, P.E.
R5 Validation Checklist-Hardcopy Received
Certificate of Independence FL16092 R5 COI (a)Certificate of Independence.odf
Referenced Standard and Year(of Standard) Standard Y_
AAMA/W DMA/CSA101/I.S.2/A440 21
ASTM E 1300 21
ASTM E1886 21
ASTM E1996 21
ASTM E1996 21
TAS 201,202,203 1!
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 07/21/2017
Date Validated 07/31/2017
Date Pending FBC Approval 08/01/2017
Date Approved 10/10/2017
Date Revised 02/20/2019
Summary of Products
FL# Model,Number or Name Description
16092.1 a.8400 Series Vinyl Horizontal Extruded PVC Horizontal Sliding Window with"Non-Imp
Sliding Window Insulated Glass(XX,OX or XO Configurations)
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL16092 R5 II (a)Inst 16092.1.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16092.1 for Design Pressure Ratings,any FL16092 R5 AE (a) Eval 16092.1.odf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
16092.2 b.8400 Series Vinyl Horizontal Extruded PVC Endvent Horizontal Sliding Window with"
Sliding Window Impact"Insulated Glass(XXX or XOX 1/4-1/2-1/4
Configurations)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16092 R5 II (a)Inst 16092.2.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16092.2 for Design Pressure Ratings,any FL16092 R5 AE (a)Eval 16092.2.odf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
16092.3 c.8400 Series Vinyl Horizontal Extruded PVC Endvent Horizontal Sliding Window with"
Sliding Window Impact"Insulated Glass(XXX or XOX 1/3-1/3-1/3
Configurations)
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL16092 R5 II (a)Inst 16092.3.Rdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 16092.3 for Design Pressure Ratings,any FL16092 R5 AE (a)Eval 16092.3.odf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
16092.4 d.8800 Series Vinyl Horizontal Extruded PVC Horizontal Sliding Window with"Impact"
Sliding Window Insulated Glass(XX,OX or XO Configurations)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16092 R5 II (a)Inst 16092.4.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16092.4 for Design Pressure Ratings,any FL16092 R5 AE (a) Eval 16092.4.odf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
6092.5 e. 8800 Series Vinyl Horizontal Extruded PVC Endvent Horizontal Sliding Window with"
Sliding Window Insulated Glass()XX or XOX 1/4-1/2-1/4 Configuration:
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16092 R5 II ( Inst 16092.5.(f
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16092.5 for Design Pressure Ratings,any FL16092 R5 AE (a) Eva[ 16092.5.odf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
16092.6 f. 8800 Series Vinyl Horizontal Sliding Extruded PVC Endvent Horizontal Sliding Window with"
Window Insulated Glass()XX or XOX 1/3-1/3-1/3 Configuration:
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16092 R5 II a)Inst 16092.6.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16092.6 for Design Pressure Ratings,any FL16092 R5 AE (a Eva[ 16092.6.odf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
16092.7 g.8800 Series Vinyl Horizontal Extruded PVC Horizontal Sliding Window with "Impact"
Sliding Window Insulated Glass(XX,OX or XO Configurations)
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL16092 R5 II (b)Inst 16092.7.udf
Approved for use outside HVHZ:Yes Verged By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16092.7 fbr Design Pressure Ratings,any FL16092 R5 AE lEval 16092.7;odf
additional use limitations,installation instructions and product Created by Independent Third Party: Yes
particulars.
16092.8 h. 8800 Series Vinyl Horizontal Extruded PVC Endvent Horizontal Sliding Window with"
Sliding Window Insulated Glass()XX or XOX 1/4-1/2-1/4 Configuration:
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL16092 R5 II (b)Inst 16092.8.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16092.8 for Design Pressure Ratings,any FL16092 R5 AE (a) Eval 16092.8.odf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
16092.9 i.7700/9900 Series Vinyl Horizontal Extruded PVC Horizontal Sliding Window with"Non-Imp
Sliding Window Insulated Glass(XX Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16092 R5 II (a)Inst 16092.9.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 16092.9 for Design Pressure Ratings,any FL16092 R5 AE (a) Eva] 16092.9.odf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
16092.10 j.7700/9900 Series Vinyl Horizontal Extruded PVC Endvent Horizontal Sliding Window with"
Sliding Window Impact"Insulated Glass(XOX 1/4-1/2-1/4 Configuratioi
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16092 R5 II (aa Inst 16092.10.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16092.10 for Design Pressure Ratings,any FL16092 R5 AE (a)Eval 16092.10.odf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
16092.11 k.7700/9900 Series Vinyl Extruded PVC Endvent Horizontal Sliding Window with"
Horizontal Sliding Window Impact"Insulated Glass(XOX 1/3-1/3-1/3 Configuratioi
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16092 R5 II (a)Inst 16092.11.df
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 16092.11 for Design Pressure Ratings,any FL16092 R5 AE (a) Eval 16092.1l.pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
16092.12 I.400 Series Vinyl Horizontal Sliding Extruded PVC Horizontal Sliding Window with Nailing Fir
Window "Non-Impact"Insulated Glass(XX Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL16092 R5 H (a)Inst 16092.12.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16092.12 for Design Pressure Ratings,any FL16092 R5 AE (a) Eva[ 16092.12.pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
16092.13 m.400 Series Vinyl Horizontal Extruded PVC Endvent Horizontal Sliding Window with N
Sliding Window Rn-"Non-Impact"Insulated Glass(XOX 1/4-1/2-1/4
Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16092 R5II (a)Inst 16092.13.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16092.13 for Design Pressure Ratings,any FL16092 R5 AE (aEval 16092.13.12-df
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
16092.14 n.400 Series Vinyl Horizontal Sliding Extruded PVC Endvent Horizontal Sliding Window with N
Window Fn-"Non-Impact"Insulated Glass(XOX 1/3-1/3-1/3
Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL16092 R5 II (a)Inst 16092.14.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16092.14 for Design Pressure Ratings,any FL16092 R5 AE (a) Eva[ 16092.14.pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
16092.15 o.500 Series Vinyl Horizontal Sliding Extruded PVC Horizontal Sliding Window with Nailing Fr
Window Integral I Channel-"Non-Impact"Insulated Glass(XX
Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16092 R5 II (a)Inst 16092.15.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16092.15 for Design Pressure Ratings,any FL16092 R5 AE (a) Eval 16092.15.odf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
16092.16 P.500 Series Vinyl Horizontal Sliding Extruded PVC Endvent Horizontal Sliding Window with P
Window Fin/Integral 3 Channel-"Non-Impact"Insulated Glass
1/4-1/2-1/4 Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16092 R5 II (a)Inst 16092.16.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 16092.16 for Design Pressure Ratings,any FL16092 R5 AE la)Eval 16092.16.pdf
additional use limitations,installation instructions and product Created by Independent Third Party: Yes
particulars.
16092.17 q.500 Series Vinyl Horizontal Sliding Extruded PVC Endvent Horizontal Sliding Window with T�
Window Fin/Integral 3 Channel-"Non-Impact"Insulated Glass
1/3-1/3-1/3 Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16092 R5 II (a)Inst 16092.17.odf
Approved for use outside HVHZ:Yes i Verified By: Lyndon F.Schmidt, P.E.43409
1 Apprq,
IApprOyed for use ut V.,Z: NO
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16092.17 for Design Pressure Ratings,any FL16092 R5 AE.(a)Eval 16092.17.pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
16092.18 r. 5400/5400S Series Vinyl Extruded PVC Horizontal Sliding Window-"Non-Impact'
Horizontal Sliding Window Insulated Glass(XX Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16092 R5 II (a)Inst 16092.18.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 16092.18 for Design Pressure Ratings,any FL16092 R5 AE (a) Eval 16092.18.odf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
16092.19 s.5400/5400S Series Vinyl Extruded PVC Endvent Horizontal Sliding Window-"Nor
Horizontal Sliding Window Impact"Insulated Glass(XOX 1/4-1/2-1/4 Configuratiol
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16092 R5 II (a)Inst 16092.19.Ddf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16092.19 for Design Pressure Ratings,any FL16092 R5 AE la) Eval 16092.19.odf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
16092.20 t.5400/5400S Series Vinyl Extruded PVC Endvent Horizontal Sliding Window-"Nor
Horizontal Sliding Window Impact"Insulated Glass(XOX 1/3-1/3-1/3 Configuratioi
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16092 R5 H (a)Inst 16092.20.Ddf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16092.20 for Design Pressure Ratings,any FL16092 R5 AE (a)Eval 16092.20.12-df
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
Back Eq---,l
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Stateme
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 4
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one."
provided may be used for official communication with the licensee.However email addresses are public record.If.you do not wish to supply a personal addre
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please c
Product Approval Accepts:
Cebdit Card
TN
N Q o�
WINDOWS&DOORS '%�j••. a' N
� oem
250 Staunton Turnpike,Parkersburg,WV 26104 �i,••••• •Q ����` d W -
« z
112"MAX.O.A.FRAME WIDTH - \ a X Z
8800 Series
50.5"MAX.D.LO.WIDTH 1 0 7
9 a S
l\ter LL ma$�
Vinyl Horizontal Sliding Window v kW
"IMPACT'
0
m
GENERAL NOTES s �{
1. This product has been evaluated and is In compliance with the 6th Edition
(201 7)Florida Building Code(FBC)structural requirements excluding the"High
Velocity Hurricane Zone"(HVHZ). 0 a
go
ho d spaced as shown on details.Anchor r3
o base material shall be a Ld[85,n or stucco.n areas requiring wind borne debris protect n this producth FBC Sections 1609.1.2&R301.2,1.2 and does not require anant covering.This product meets missile level"D"and includes Windfined In ASTM El 996 and FBC Sections 1609.1,2.2&R301.2.1.2.1. _ rn
4. For 2x stud framing cons ruc ran, fs shall be the sam
that shown for 2x buck masonry construction. XOX SHOWN a o 0
5. Site conditions that deviate from the details of this drawing require further XXX ALSO APPROVED
»� z
engineering analysis by a licensed engineer or registered architect.
TABLE OF CONTENTS MAX MAX GLASS fi DESION PRESSURE
SHEETS DESCRIPTION FRAME D L`0 TYPE _
1 Typical elevations,design pressures an enera notes r DIMENSION , DIMENSION,, _ POSRNE;, NEGATNE* n N z
2 Horizontal cross sections 110,0"X 62.0" 49.5"X 54.0" 01 +45.0 •45.0 aac 12105112 c
3 Vertical cross sections scum N.T.S.
4 Buck an frame anchorin
5 5 Components
112.0"X 63.0" 50,5"X 55.0" G2 -55.0 °'� en JK m
6 Bill of mate ais& larin deta DRAM art LFS
3g 112.0"X 63A" 50.5"X 55.0" G3 +60.0 -65.0 DRAMNO No" N
FL-16092,5 c
SHM—L OF 6
it
C 1 2 G1 G3 +y:. �e * ° 4HEm
d'md
z x z o x �� m a
t`d
8 16 b Z
e a
A D y
� o
3 4 HORIZONTAL CROSS SECTION m c
2
Shown Wuc x�
EMB.(TYP.) c
(iYP)
B G C 1 2 G1 G2 G3 C 1 2 G1 G2 G3
3 15
INTERIOR '
t•
.
OF]
O C� i o . O�� N N O N
' O 88y o
OF B 16 5 9 8 16 5 q
a EXTERIOR >>
4 t Imo- M
oNoa
16 5 GI G2 G3 "
C:0
D DATE:12105112 1 i
E SDAu: N.T.S. a
uwa we, JK m
1 HORIZONTAL CROSS SECTION 2 HORIZONTAL CROSS SECTION 3 HORIZONTAL CROSS SECTION CHIC.BY, LFS ?+
$ Shown w buck2 . 2 Shown d rec o vaosonry oH�w Ho r�o,: rc
FL-16092.5 a
a
SHEEP�OF� N
d
`g� • �': y
lit
O`er' ` C
D A �i �''•
o8 .,=
B 4,� ' 12 N 9mCM
F 17 5M
0 e a o 6 €Z
1 n 12 0
�j 17 19 Stop for Ned 6 228
o 0 0 6 window 14
22 5 G1 G2 G3 o
O EXTERIOR INTERIOR
14 jy
lit I
5 2 VERTICAL CROSS SECTION $ o
01 G2 G3 g Shown w/1X buck p
EXTERIOR INTERIOR i of
a
G1 G2 G3 INTERIOR
5 6 G1 G2 G3
7 6 nv�
N N O
N
22 14 �� 7 8 8 o
V)
17 14
22
1 11 17So
M a = C i �»
g H a o I C oN�a
D nN^Z n
E .. '. K Dail 12 05 12 0
'o
.,' SCAM N.T.S. g
owe.By, JK m'
3VERTICAL CROSS SECTION ct,w M LFS ;
1 VERTICAL CROSS SECTION 3 Shown direct to masonry ° FL—1x092.5 "
3 Shown w/2X buck °
SKET_L OF�, d
d �
Tok
W. * ;
11.1111y
MEETING STILE MEEUNGSIILE w
mP► �{ mP) -.I Imo- w
u•' .,. (TYP,) '"' I I s"O,C. I►YP•) rly �Z
•� I I I I �_ I I I I -
4 •'
I 12 I I z
mP.) II PYP.0HEAD) II 0
77
_ I I F 2X BUCK I I .. oR
BUCK II II G 2X BUCK II L 1XBUCK II H 2XBUCK o Y �
D IX BUCK II DIRECTTO II '3 � m
MASONRY II II DIRECTTO II K MASONRY II L 1XBUCK
OPENING II II MASONRY II II DIRECTTO Q,
I I I I QYP.@ I I HEAD) I I K MASONRY M o
JAMB) II II
• II it � II II �
�o II II ���
II II -
'."�•' ,
IN, "t•' --) I--(1YP.) 7•S'(IYP.) N N p fA
80� o
BUCKANCHORING FRAMEANCHORING H
CONCRETEANCHOR NOTES:
1•Concrete anchor locations at the comers may be adjusted to maintain the min,
edge distance to mortar joints.
2•Concrete anchor locations noted as"MAX,ON CENTER"must be adjusted to
maintain the min.edge distance to morforjofnts,additional concrete anchors
ma b R"dimension are not exceeded.
3 C a anchor table tn 2 E
ANCHOR ANCHOR' MIN MIN CLEARANCE MI ANCE;
TYPE SIZE EMBEDMEfJP TO MASONRY TO gD1A: m a
EDGE ANCHOR o 0
T I ON® 1/4" 1.1/4" 2" 4" n N^Z a
EL ate 12105112 z
ULTRACON® 1/4" 1.1/4" sruc N.T.S. 9
KWIK CON II+ 1/4" 1.1/4" 2.1/2" 3" CHw BY: LFS ;
WOODS INSTALLATION NOTES: CROM No,:
I.Maintoln a minimum 5/8"edge distance,1"end distance,d 1"o.c,spacing of "
FL-16092,5
b wood screws to prevent the splitting of wood. JZ
_4-SHM�os,�
?i
he
*
A-
aa ,3�m.a�FmA
2.04"
1.9" uJ{Lz "_ epnnn Yllj �to;
LEj
� AF36(1-1I2"Bt1ck Mould) �i ��•••.,,•p� riVO
g' 0.07° v 6r cJ (t r ii r ^ ''�� pCO
0.07" ra ...Si:A. .dss( ��{ II{ �{;a '' 1 =Agri v c
l��' amq� �mamgPc3lmm�u�n i'I \` L mCW1.42"---� ! J} a ;L Sp N W a 0..
a�m,n��35 �
,1 SLIDER PULLSIILE 3 LOCKSAI6 FRAME °�
AF59(Masonry Flange:,)] V672(Masonry Range 2( d
OPTIONAL COSMETIC FLANGES
1 AT
I 0.34n En
1.37"
OW� 0.08"
o 0.24" } c
p o
0
0.31 a a
0.71
4 KEEPER SDIE 5 OlA ING EEAD 6 SLIDER COMMON RAIL 12 HEAD 1RACK EE �y
� SILL TRACK uT
p WE width 6"IOnG
N N�
N
e8y o
in0.09" 0
o �o�
. • L �.. �-- �
_ a oho¢
►— 0.08" 0.08" MZ
0.67' '°^.rMZ
C h N^Z [�]
* REINFORCEM REINFORCFMEM REI RCEMEM 19 FLANKE STOP DAm 12105112 =
M COtomoCIS 15 loekSNe 16 KeapaondPuliShle �� SLIDER SASH RETAINING CLIP scams N.T.S.
0
5
MO.BY: JK m
cHK,By. LFS 3
MWNG NO.:
N
FL-16092.5 0
SHEEP,5 OF 6 N
d
BILL OF MATERIALS
r1E
M 0 DESCRIPTION MATERIAL �r ,�1► 2
A 1 X BUCK SG>=0.42) WOOD 1/2"GIASS NOVAFLEX M400 =V * t�
B 2X BUCK($G>=0.42) WOOD 1"THICK GLASS 'N: $ d a
C 1/4"MAX.SHIM SPACE - BRE �V••,
D MASONRY4-3 F000 PSI WR CONCRETE CONFORMING TO ACI[TW CONCRETE SCREW STEEL •.,,.........C i o m a
1/8"ANNEALED iii �� R.> O1
301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE - OA90"SAfLEX®PVB IMERLAYER ',�� I I I T 11 ` 8`R.'Z
F #10 X 3"PPH WOOD SCREW 1.3/8"MIN.EMBEDMENT STEEL O v $
G #10 X 1-3/4'PPH WOOD SCREW(1-1/8"MIN.EMBEDMENT) STEEL ^ E0' Z m e w
H 10 X 2-1/2'PPH WOOD SCREW(7/8"MIN.EMBEDMENT STEEL 1/8"ANNEALED \ .t 9 1 q=a
J 114"X 2-1/4"ITW CONCRETE SCREW STEEL AIR SPACE \ LL m a a
K 1 XX 3-1/4"ITW CONCRETE SCREW STEEL V o
1/8"ANNEALED r,
L 1/4"X 3-3/4"ITW CONCRETE SCREW STEELa
1 FRAME* PVC INTERCEPT SPACER
2 SLIDER PULL STILE* PVC Gi GLAZING DETAIL
3 LOCK STILE* PVC
4 KEEPER STILE' PVC
5 GLAZING BEAD" PVC a
6 SLIDER COMMON RAIL' PVC 1/T GLASS NOVAFIEX M400 o
7 BALL BEARING ROLLER BITE 1"THICK GLASS y i
8 WEATHERSTRIP(0.230 ro o
9 WEATHERSTRIP(0.380") 1/8"ANNEALED CO g 0
11 SILL TRACK ALUM o m
12 HEAD TRACK ALUM 0A90"SAFLEX®PV8INTERLAYER I
14 SLIDE RAIL REINFORCEMENT(6063-T6 ALUM) ALUM 0
15 REINFORCEMENT(6005-T5 ALUM) ALUM 1/8"ANNEALED
16 REINFORCEMENT 6005-T5 ALUM ALUM
17 SLIDER SASH RETAINING CLIP ALUM AIR SPACE
18 #8 X 1"PFH SMS STEEL 1/8"TEMPERED
19 FLANKER STOP NYLON INTERCEPT SPACER "
22 #8 X 5/8"(#6 head)PFH SMS STEEL GLAII 00Oa
G w '�
+T •THE APPROVED WHITE RIGID PVC EXTERIOR EXTRUSIONS FOR WINDOWS ARE TO BE PRODUCED BY 8 8 y o
EXTRUDERS LICENSEES IN"AAMA CERTIFICATION PROGRAMS FOR RIGID PVC EXTRUSIONS". w N
1/7'GLASS SIKA 552 R D g
BITE 1"THICK GLASS M
1/W ANNEALED ^
0 1— 0.090"SENTRYGLASOINTERLAYER v o
m
z
1/8"ANNEALED n` z o
AIR SPACE DATE 12105112 =
SCAM N.T.S. 9
1/9-TEMPERED DwD,BY. JK m'
INTERCEPT SPACER CHK Or. LFS ?+
G3 OIAZING DETAIL DRAWMD NO--
FL-16092,
O-FL-16092. 0
SHEET G Oi_L N
G
z