Loading...
HomeMy WebLinkAboutDesign Pressure calculations 1 ,. ,, , , ," ' 1‘, '1 S . . .EXT� i, 4 "building Our Quality Reputation One Customer At A Time" SCC131150472 Property Information Building Information Owner: ANTHONY&KAREN PRESUTTI Wind Zone: 170 MPH. Address: 951 EMERALD AVE Exposure Category: C FORT PIERCE,FL 34945 Minimum Building Dimension: 64 ft. Mean Roof Height: 12 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) , 1 Int 37 77 7 36.1 -39.3 2 Int 73 49 7 35.6 -38.8 3 Int 36 49 7 37.3 -40.5- 4 End 72 48 7 35.6 -46.3 5 End 72 49 7 35.6 -46.2 6 Int 73 49 7 35.6 -38.8 7 Int 73 49 7 35.6 -38.8 8 End 35 36 7 37.8 -50.6 9 End 73 49 7 35.6 -46.1 10 End 73 49 7 35.6 -46.1 11 Int 36 37 7 37.8 -41.0 12 Int 36 37 7 37.8 -41.0 13 Int 34 35 7 37.8 -41.0 14 Int 95 79 7 - 33.7 -36.9 15 End 17 36 7 37.8 -50.6 16 End 33 80 7 36.3 -47.6 17 Int 110 49 7 34.6 -37.8 Prepared in accordance with:ASCE 7-10,Chapter 30.Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page 1 of 1 • ;_.. �. WINDOW _O. R OPENING MAT,ION{,w z 4P ,;',:i A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET Definition of Corner Zone -10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft. OPENING (Location) IS THIS A PRODUCT PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE ARE GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW LOCATION Corner Zone WINDOW TYPE ACCEPTANCE TESTED OPENING - SHUTTERS NUMBER or Interior OR DOOR NUMBER (+)PSF (-)PSF (+)PSF (-)PSF DIMENSIONS MULLION REQ Y/N/NA SIZE REQ YM 1 Int Door I"Lami IG FL15210.4 75 75 36.1 -39.3 37.5 x 81 37x77 No No 2 Int Window 7/8"Lami IG FL16736.1 60 60 35.6 -38.8 74 x 63 73x49 No No 3 Int Window 1"Lami IG FL13010.4 55 55 37.3 -40.5 48x72 36x49 No No 4 End Window 7/8"Lami IG FL16736.1 60 60 35.6 -46.3 74 x 63 72x48 No No 5 End Window 7/8"Lami IG FL16736.1 60 60 35.6 -46.2 74 x 63 72x49 No No 6 Int Window 7/8"Lami 10 FL16736.1 60 60 35.6 -38.8 74 x 63 73x49 No No 7 Int Window 7/8"Lami IG FL16736.1 60 60 35.6 -38.8 74 x 63 73x49 No No 8 End Window 7/8"Lami FL16177.1 70 70 37.8 -50.6 52x62 35x36 No No 9 End Window 7/8"Lami IG FL16736.1 60 60 35.6 -46.1 74 x 63 73x49 No No 10 End Window 7/8"Lami IG FL16736.1 60 60 35.6 -46.1 74 x 63 73x49 No No 11 Int Window 7/8"Lami FL16177.1 70 70 37.8 -41.0 52x62 36x37 No No 12 Int Window 7/8"Lami FL16177.1 70 70 37.8 -41.0 52x62 36x37 No No 13 Int Window 7/8"Lami FL16177.1 70 70 37.8 -41.0 52x62 34x35 No No 14 Int Door 1"Lami IG FL 11103.1 60 60 33.7 _36.9 96 x 96 95x79 No No 15 End Window 7/8"Lami FL16177.1 70 70 37.8 -50.6 52x62 17x36 No No 16 End Door Solid FL15210.1 75 75 36.3 -47.6 37.5 x 81 33x80 No No 17 Int Window 7/8"Lami 1G FL16736.2 60 60 34.6 -37.8 111 x63 110x49 No No