Loading...
HomeMy WebLinkAboutDrawing Size ' opening :I (wXH) 77� 1 FL15781 11 72 z 36 (HORIZONTAL.'SLlDER) 2. FL15781.11 72�z 36 (HORIZONTAL SLIDER)• .'3 FL15781 11 : 35 x 36 ° (HORIZONTAL SLIDER) �I O 4 FL_57.81 11 36"x+36 60 (HORIZONTAL SLIDER) 5 FL15781 11, 36 x 36 (HORIZONTAL SLIDER) e ^ F- 6. FL157811.11 35z36 < (HORIZONTAL SLIDER) ,+r r�- Z 'FL15781 11 35 x37 6 BATH 2 Q - (HORIZONTAL'SLIDER) 7 8 9 1 U �� 71f z 80 40 E NN 9 FL15781.1,1 Wx36 Q :3(HORIZONTAL,SLIDER) (� 1�0 FL15781 11 36 x BATH 3 DINING 35 KITCHEN LAUNDRY (D (HORIZONTAL SLIDER) a O 11 FL1,5781 11 73 x;36 � (HORIZONTAL SLIDER) 5 BED 3 m 12 FL13010.4 17 z'49 ° (FIXED.WINDOW) 13. FL15781.11 49 x 49 p� (HORIZONTAL SLIDER) �� �{ 14 FL13010.4 17 z 49 (FIXED WINDOW) 15 FL130'10 4 17"z49 (RXED WINDOIM - 16 FL`15781.11' 50 z 49 4 BATH 1 (HORIZONTAL SLIDER) . 17. FL13010A 17.x 49 N W}(FIXEDWINDO W � ,18 FL15781Al z 54-x'4 N (HORIZONTAL SLIDER) =19 FL15781 541z�49 V W z LL (HORIZONTAL SLIDER) 3 11 Q LLI BED 2 BED 1 FAMILY W W 0� m Y W 60" 2 1 19 18 BED 4 33„ LIVING LL 84„ 17 15 14 12 GNr E°TEYPEGr.DGY SCALE: - NOT TO SCALE 16 13- ._. ' Apr 09,2019 4 PAGE DESCRIPTION: Site Plan R --_ PAGE: OF1 PARAWSEIEXT!�:WQRS "Building Our Quality Reputation One ,Customer At A Time SCC131150472 Property Information Building Information Owner: ROBERT CASE Wind Zone: 170 MPH. Address: 627 KEARNEY RD Exposure Category: C FT PIERCE,FL 34982 Minimum Building Dimension: 44 ft. Mean Roof Height: 12 ft. Risk Category: II I Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 5 1 Int 72 36 7 36.4 -39.6 2 End 72 36 7 36.4 -47.7 3 Int 35 36 7 37.8 -41.0 4 Int 36 36 7 37.8 -41.0 5 Int 36 36 7 37.8 -41.0 6 Int 35 36 7 37.8 -41.0 7 Int 35 37 7 37.8 -41.0 8 Int 71 80 7 34.4 -37.6 _- ......... - ---......---- ............... _... _..- 9 Int 36 36 _ 7 37.8 -41.0 10 End 36 35 7 37.8 -50.6 11 Int 73 36 7 36.3 -39.5 ..................- ..-..----._._......._.-....--- ---- --............_.....------ - - - ..................-- -..... _-...._..- - --....._._._-.._ 12 End 17 49 7 37.8 -50.6 13 Int 49 49 7 36.5 -39.7 14 Int 17 49 7 37.8 -41.0 15 Int 17 49 7 37.8 -41.0 16 Int 50 49 7 36.5 -39.7 17 Int 17 49 7 37.8 -41.0 18 Int 54 49 7 36.3 -39.5 19 Int 54 49 7 36.3 -39.5 Prepared in accordance with:ASCE 7-10,Chapter 30.Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page 1 of 1 A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET Definition of Corner Zone-10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft. OPENING (Location) IS THIS A PRODUCT PRODUCT APPROVAL. REQUIRED OPENING MAXIMU ROUGH MULTIPLE ARE GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW LOCATION Corner Zone WINDOW ACCEPTANCE OPENING SHUTTERS NUMBER or Interior OR DOOR TYPE NUMBER (+)PSF (-)PSF (+)PSF {-)PSF SIZE TESTED DIMENSIONS MULLION REQ Y!N/NA REQ Y/N 1 Int Window 7/8"LamilG FL15781.11 55 60 36.4 -39.6 73x63 72x36 No No 2 End Window 7/6"LamilG FL15781.11 55 60 36.4 -47.7 73 x 63 72x36 No No 3 Int Window 7/8"LamilG FL15781.11 55 60 37.8 -41.0 73 x 63 3506 No No 4 Int Window 7/8"Lami,G FL15781.11 55 60 37.8 -41.0 73 x 63 36x36 No No 5 Int Window 718"LamilG FL15781.11 55 60 37.8 -41.0 73 x 63 36x36 No No 6 Int Window 718"LamilG FL15781.11 55 60 37.8 -41.0 73x63 35x36 No No 7 Int Window 7/8"LamilG FL15781.11 55 60 37.8 -41.0 73 x 63 35x37 No No 8 Int Door V Lami IG FLl 1103.1 60 60 34.4 -37.6 96 x 96 71x80 No No 9 Int Window 7/8"L.iIG FL15781.11 55 60 37.8 -41.0 73x63 36x36 No No 10 End Window 7/8"LamilG FL15781.11 55 60 37.8 -50.6 73 x 63 36x35 No No 11 Int Window 7/8°Lami IG FL15781.11 55 60 36.3 -39.5 73 x 63 73x36 No No 12 End Window V Lami IG FL13010.4 55 55 37.8 -50.6 4802 17x49 YES No 13 Int Window 711"LamilG FL15781.11 55 60 36.5 -39.7 73 x 63 49x49 YES No 14 Int Window V Lami IG FL13010.4 55 55 37.8 -41.0 4802 17x49 YES No 15 Int Window V Lami IG FL13010.4 55 55 37.8 -41.0 4802 17x49 YES No 16 Int Window 718"Lami lG FL15781.11 55 60 36.5 -39.7 1 73 x 63 50x49 YES No 17 Int Window I"Lami IG FL13010.4 55 55 37.8 -41.0 4802 17x49 YES No 18 Int Window 718"Lam1IG FL15781.11 55 60 36.3 -39.5 73 x 63 54x49 YES No 19 Int Window 7/8"Lami lG FL15781.11 55 60 36.3 -39.5 73x63 54x49 YES No