HomeMy WebLinkAboutUntitled (3) Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_Ist.aspx
"k,
SCIS Home I Log In i User Registration I Hot Topics Submit Surcharge ( Stats&Facts Publications Contact Us I SCIS Site N
bHodda
! Product Approval
-�
�USER:Public User RLCEIV ED
Product Approval Menu>Product or Application Search>Application List APR 16 2019
77
ST. Lucie County, Prmltln�
` Search Criteria Refine Search
Code Version 2017 FL# 10124
Application Type ALL Product Manufacturer ALL
Category ALL Subcategory ALL
Application Status ALL Compliance Method ALL
Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL
Product Model, Number or Name ALL Product Description ALL
Approved for use in HVHZ ALL Approved for use outside HVHZ ALL
Impact Resistant ALL Design Pressure ALL
Other ALL
Search Results-Applications
FL# Type Manufacturer Validated By Status
FL10124-R20 Revision GAF John W.Knezevich, PE Approved
History Category: Roofing (954)772-6224
Subcategory:Asphalt Shingles
FL10124-R21 Revision GAF John W.Knezevich, PE Pending FBC Approval
Category: Roofing (954)772-6224
Subcategory:Asphalt Shingles
'Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Re
Under Florida law,email addresses are public records.If you do notwant your e-mail address released in response to a public-records request,
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.`Pursuant
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if the
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a pE
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,
Product Approval Accepts:
tai
Credit Card
Safe
FILE
COPY
1 of 1 4/11/19, 12:46
Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.asp...
BCIS Home Log In { User Registration j Hot Topics f Submit Surcharge F Stats&Facts Publications Contact Us BCIS Site N
ba
333 *Product Approval
USER:Public User L,-%r
Product Approval Menu>Product or Application Search>Application List>Application Detail
7, FL# FL10124-R20
Application Type Revision
I LM
Code Version 2017
Application Status Approved
Comments
Archived (A
Product Manufacturer GAF
Address/Phone/Email 1 Campus Drive
Parisppany,NJ 07054
(800)766-3411
mstieh@gaf.com
Authorized Signature Robert Nieminen
Ireith@nemoetc.com
Technical Representative William Broussard
Address/Phone/Email 1 Campus Drive
Parsippany,NJ 07054
(800)766-3411
TechnicalQuestionsGAF@gaf.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a
Professional Engineer
L---•.1 Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/18/2021
Validated By John W.Knezevich,PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL10124 R20 COI 2017 dl COI Nieminen.pdf
1 of 3 4/11/19, 12:46
Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.asp...
Referenced Standard and Year(of Standard) Standard Y
ASTM D1970 2
ASTM D3161 2
ASTM D3462 2
ASTM D7158 2
TAS 107 1
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 09/20/2017
Date Validated 09/27/2017
Date Pending PBC Approval 09/28/2017
Date Approved 12/12/2017
Date Revised 02/19/2019
Summary of Products
FL# Model,Number or Name Description
10124.1 GAF Asphalt Roof Shingles Fiberglass reinforced 3-tab,laminated,5-tab ar
shingles
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL10124 R20 II 2017 09 FINAL ER GAF
Approved for use outside HVHZ:Yes Shingles FL10124-R20.pdf
Impact Resistant: N/A Verified By: Robert Nieminen PE-59166
Design Pressure: N/A Created by Independent Third Party:Yes
Other: Refer to ER,Section 5. Evaluation Reports
F-L10124 R20 AE 2017 09 FINAL ER GAF
Shingles FL10124-R20.pdf
Created by Independent Third Party:Yes
Back Next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Re
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if the
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a pe
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,
Product Approval Accepts:
IF-iffl-91 '' ¢Check
2 of 3 4/11/19, 12:46
Florida Building Code Online https://Www.floridabuilding.org/pr/pr app_dtl.asp...
Credit Card
Safe
3 of 3 4/11/19, 12:46
i
�If EXTERIOR RESEARCH&DESIGN,I.I.C.
f Certificate of Authorizo tion#9503
N STREET,UNIT#13
TRINITY ERD 353 CHRISTIAOXFORD,CT 06478
(203)262-9245
EVALUATION REPORT
GAF Evaluation Report 01506.01.08-1122
1 Campus Drive F1.10124-1120
Parsippany,NJ 07054 Date of Issuance:01/03/2008
(800)766-3411 Revision 22:09/20/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: GAF Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1/R905.2.6.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen,P.E.if the
product changes or the referenced Quality Assurance documentation changes. TrinitylERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT:The Evaluation Report number preceded by the words"Trinity IERD Evaluated"may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by: M),�,,,,,,,;
"Z-'
Robert J.M.Nieminen,P.E.
TM facsimile seals nwa
.� rrrrr rr,.� ppcvri gs authorized 6y Rabcrt lJlemfnen,
Florida Registration No.59166,Florida DCA ANE1983 P.E on 09lml:ov.This does not serve as an electronically signed
donmem.
CERTIFICATION OF INDEPENDENCE:
1. TrinityI ERD does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest In any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity(ERD nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINITY I ERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: GAF Asphalt Roof Shingles,as produced by GAF,have demonstrated compliance with the
following sections of the 61h Edition(2017) Florida Building Code and Florida Building Code, Residential Volume
through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements
and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Proper Standard Year
1507.2.4/1507.1.1, Physical Properties ASTM D1970 2015
R905.2.3/R905.1.1
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011
1507.2.7.1,R905.2.6.1 Wind Resistance TA5107 1995
3. REFERENCES:
gnilty Examination Reference Date
GAF(PDM 1915) Letter of Equivalency Seal-A-Ridge Impact Resistant IR 01/13/2012
PRI(TST 5878) Physical Properties GAF-025-02.01 03/27/2002
PRI(TST 5878) ASTM D3462 GAF-059-02-01 09/02/2004
PRI(TST 5878) ASTM D3462 GAF-080-02-01 05/25/2005
PRI(TST 5878) Physical Properties GAF-324-02-01 12/01/2011
PRI(TST 5878) Wind Driven Rain GAFA07-02-01 01/21/2013
UL(TST 1740) ASTM D3462 93NK6295 11/29/1993
UL(TST 1740) ASTM D3462 99NK43835 01/12/2000
UL(TST 1740) TAS 107 94NK9632 03/29/2000
UL(TST 1740) ASTM D3462 OINK06632 02/02/2001
UL(TST 1740) ASTM D3161,TAS 107 OINK9226 05/21/2001
UL(TST 1740) ASTM D3161 OINK37122 12/18/2001
UL(TST 1740) ASTM D3462 01NK37122 12/19/2001
UL(TST 1740) ASTM D3161,TAS 107 02NK12980 04/10/2002
UL(TST 1740) ASTM D3161,TAS 107 02NK30871 09/09/2002
UL(TST 1740) ASTM D3161 03CA5367 03/11/2003
UL(TST 1740) ASTM D3462 03NK26444 10/17/2003
UL(TST 1740) ASTM D3462 04NK13850 06/07/2004
UL(TST 1740) ASTM D3161 04NK13850 06/23/2004
UL(TST 1740) ASTM D3161 04NK30546 03/10/2005
UL(TST 1740) ASTM D3462 04NK22009 05/06/2005
UL(TST 1740) ASTM D3161 04NK22009 05/09/2005
UL(TST 1740) ASTM D3462 OSNK27924 02/10/2006
UL(TST 1740) ASTM D3161 OSNK27924 02/11/2006
UL(TST 1740) ASTM D3161,D3462 06CA18077 06/05/2006
UL(TST 1740) ASTM D3161,D3462 06CA18074 06/16/2006
UL(TST 1740) ASTM D3161,D3462 06CA35251 10/18/2006
UL(TST 1740) ASTM D3462 06CA31603 12/01/2006
UL(TST 1740) ASTM D3161,D3462 06CA41095 12/27/2006
UL(TST 1740) ASTM D3161 07NK05228 03/13/2007
UL(TST 1740) ASTM 03161 06CA31611 04/04/2007
UL(TST 1740) ASTM D3161 06CA61148 04/09/2007
UL(TST 1740) ASTM D3161,D3462 07CA31742 11/08/2007
UL(TST 1740) ASTM D3161,D7158,D3462 OBCA06100 03/13/2008
Exterior Research and Design,I.I.C. Evaluation Report 01506.01.08-1122
Certificate ofAvthorhoNnn#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10124-RZO
GAF Asphalt Roof Shingles Revision Z2:09/20/2017
Page 2 of 6
`1111,.J TRINITY ERS
Knifty Examination Reference Date
UL(TST 1740) ASTM D3161,D3462 07CA55908 04/01/2008
UL(TST 1740) ASTM D3161,D3462 09CA10592 03/26/2009
UL(TST 1740) ASTM D3161,D3462 09CA06856 05/15/2009
UL(TST 1740) ASTM D3161,D7158,03462 09NK06647 08/01/2009
UL(TST 1740) ASTM D3161,137158,133462 09CA27281 08/27/2009
UL(TST 1740) ASTM D3161,D7158,D3462 IOCA35554 03/05/2010
UL(TST 1740) ASTM D3161,D7158,D3462 1OCA13686 05/15/2010
UL(TST 1740) ASTM 03462 10CA07264 05/27/2010
UL(TST 1740) ASTM 03462 IOCA11953 10/29/2010
UL(TST 1740) ASTM D3161,D7158,D3462 1ONK11951 10/30/2010
UL(TST 1740) ASTM D3161,D7158,D3462 1ONK12070 11/04/2010
UL(TST 1740) ASTM D3161,D7158,03462 08CA06100 01/30/2010
UL(TST 1740) ASTM D3161,D7158,D3462 IOCA53934 03/31/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48924 10/22/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA47919 12/03/2011
UL(TST 1740) ASTM 03161,D7158,03462 11CA49408 12/08/2011
UL(TST 1740) ASTM D3161,D7158,03462 11CA48725 12/09/2011
UL,LLC.(TST 9628) ASTM D3462 12CA34891 10/12/2012
UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 12CA58151 02/15/2013
UL,LLC.(TST 9628) ASTM D3161 12CA38083 02/26/2013
UL,I.I.C.(TST 9628) ASTM D3161 13CA32332 06/18/2013
UL,I.I.C.(TST 9628) ASTM D3161 13CA37934 08/02/2013
UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4786875675 07/17/2015
UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4787434542 05/17/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Mobile,AL 10/25/2016
UL,LLC(QUA 9625) Quality Control Inspection Report,R21,Myerstown,PA iD/20/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Tuscaloosa,AL 11/11/2016
UL,I.I.C.(QUA 9625) Quality Control Inspection Report,R21,Michigan Cty,IN 11/01/201.6
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Shafter,CA 11/17/2016
UL,I.I.C.(QUA 9625) Quality Control Inspection Report,R21,Savannah,GA 11/11/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Minneapolis,MN 10/25/2016
UL,I.I.C.(QUA 9625) Quality Control Inspection Report,R21,Mt.Vernon,IN 10/25/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Baltimore,MD 10/21/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Tampa,FL 11/17/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Dallas,TX 11/04/2016
UL,I.I.C.(QUA 9625) Quality Control Inspection Report,R21,Ennis,TX 11/03/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Fontana,CA 11/01/2016
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Marquis® WeatherMax", Royal Sovereign' and Sentinel' are a fiberglass reinforced 3-tab asphalt roof
shingles.
4.1.2 Camelot', Camelot"' 11, Fortitude'", Glenwood", Grand Canyon", Grand SequoiaO, Grand Sequoia" IR,
Grand Sequoiao ArmorShield`", Monaco", Sienna®, Timberline® American Harvest®, Timberline,,
ArmorShield'"11,Timberline®Natural ShadowO,Timberline HD`r,TimberlineO Cool Series",Timberline Ultra
HD°and Woodland®are fiberglass reinforced,laminated asphalt roof shingles.
4.1.3 Slateline"is a fiberglass reinforced 5-tab asphalt roof shingle.
4.2 Hip&Ridge Shingles:
4.2.1 Seal-A-Ridge* Ridge Cap Shingles, Seal-A-RidgeO IR Impact-Resistant Ridge Cap Shingles, Sea(-A-Ridge"
ArmorShield"Ridge Cap Shingles and Timbertexl Premium Ridge Cap Shingles are fiberglass reinforced,hip
and ridge asphalt roof shingles.
Exterior Research and Design,U.C. Evaluation Report 01506.01.08-R22
Certificate o/AuthorhoW n#9503 6T"EDITION(2017)FBC NON-WHZ EVALUATION FL10124-R20
GAF Asphalt Roof Shingles Revision 22:09/20/2017
Page 3 of 6
�TfRINITYIERD
r
4.3 Accessory Starter Strips:
4.3.1 Pro-Start'Eave/Rake Starter Strip Shingles and Weather Blocker`"Premium Eave/Rake Starter Strip Shingles
are starter strips for asphalt roof shingles.
4.3.2 QuickStart® Peel & Stick Starter Roil is a is a mineral-surfaced, fiberglass-reinforced, self-adhering SBS
modified bitumen starter strip,nominal 9-inch x 33 ft roll,for use with asphalt shingles with exposure of 6-
inch or less. .
4.3.3 StarterMatchT"Starter Strip Shingles are color-coordinated starter strips for use with Grand Canyon'and
Grand Sequoia' series asphalt shingles. StarterMatch- are installed as the second starter for Grand
Canyon°and Grand Sequoia'series installations.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity)ERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof,is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
S.4 Wind Classification:
5.4.1 The GAF asphalt shingles noted in Section 4.1 are Classified in accordance with FBC Tables 1507.2.7.1 and
R90S.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H,indicating the shingles are acceptable for
use in all wind zones up to Vasd=150 mph(Vett=194 mph). Refer to Section 6 for installation requirements
to meet this wind rating.
5.4.2 The GAF hip&ridge shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1
and R905.2.6.1 to ASTM D3161,Class F,indicating the shingles are acceptable for use in all wind zones up
to V.,j=150 mph(Vmt=194 mph). Refer to Section 6 for installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies only to exposure category B or C,as defined in FBC 1609.4.3,and a
mean roof height of 60 feet or less. Calculations by a qualified design professional are required for
conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval,or be
Locally Approved per Rule 61G20-3,per FBC 1507.2.3,1507.2.4 or 8905.2.3.
6.2 Starter Shingles or Starter Strip:
6.2.1 Installation of Pro-Start Eave/Rake Starter Strip Shingles,WeatherBlocker Premium Eave/Rake Starter Strip
Shingles and QuickStart Peel&Stick Starter Roll shall comply with the GAF current published instructions.
6.3 Asphalt Shingles:
6.3.1 Installation of asphalt shingles shall comply with the GAF current published instructions,using minimum four
(4)nails per shingle in accordance with FBC 1507.2.7 or R90S.2.6,with the following exceptions:
Q Came lot,.Camelot 11,Grand Canyon,Grand Sequoia,Grand Sequoia IR,Grand Sequoia ArmorShield,
and Woodland require minimum five(5)nails per shingle.
Slateline requires minimum six(6)nails per shingle.
6.3.2 Fasteners shall be in accordance with manufacturer's published requirements,but not less than FBC 1507.2.6
or R905.2.5. Staples are not permitted.
6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. Contact the GAF for details.
Exterior Research and Design,I.I.C. Evaluation Report 01506.01.08-RZZ
Certificate ofAuthomation#9303 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10124-R20
GAF Asphalt Roof Shingles Revision Z2:09/20/2017
Page 4 of 6
� TRINITYIERD
6.4 Hip&Ridge Shingles:
6.4.1 Installation of Seal-A-Ridge Ridge Cap Shingles, Seal-A-Ridge IR Impact-Resistant Ridge Cap Shingles and
Seal-A-Ridge ArmorShield Ridge Cap Shingles shall comply with the GAF current published instructions with
a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and nominal 0.25-inch diameter
beads of Henkel"Lo(flR!PLS30 Roof&Flaming SealarB'.
11,5' Sealant
I• {292 mm) 1' Sellanto
{25 mm) (25 mm) Endues detanch6M
(305 mm)
Nail
Clavo
6 S.f8'-7 5/8' Clouer
(168-194 mm)
12'
{305 mm)
6.4.2 Installation of Timbertex Premium Ridge Cap Shingles shall comply with GAF current published instructions
with a minimum two(2)nails,minimum 3/8-inch head diameter,per shingle and beads of Sonneborn NPI
Gun Grade Polyurethane Sealant or Henkel PL Roofing and Flashing Sealant.
Its. ffrrSeaa111
1• {282mn) 1' Ullanto
>2;%am} S'�mm? &rduii d'utsrdtlF";ib
Ne
tt,
CES-10r001
Ctocer
o'
I?.29 rttm)
1
tY
(305 mrrl)
6.4.3 Fasteners shall be in accordance with GAF published requirements, but not less than FBC 1507.2.6 or
R905.2.5. Staples are not permitted.
Exterior Research and Design.U.C. Evaluation Report 01506.01.08-R22
Certificate of Authodration#9503 6'"EDITION(2017)FBC NON-WHZ EVALUATION FL10124-R20
GAF Asphalt Roof Shingles Revision 22:09/20/2017
Page 5 of 6
TRINITY ERD
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1/R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625;(847)664-3281
END OF EVALUATION REPORT-
Exterior Research and Design,I.I.C. Evaluation Report 01506.01.08-1122
Certificate oJAuthoraation 09503 6T"EDITiON(2017)FBC NON-HVHZ EVALUATION FL10124-R20