Loading...
HomeMy WebLinkAboutProduct Approval-Door tie d-10 ,,, h f. " SII I' tit; �"f' #»L �4-,-1,n l Akregp t' <; �'' i' s C n t ti; --:),0 A p x l Y p ,4 i it f,-�+k F _ n -�- f' .. fit} fa `'4yf"` i "? +St� H4' Y.ia � .........._ __. _..... ..._ -t .—........,.«.,.�...;:b x ._ ,.. �....a.»...�" ids....-,......,i,�.II;..aaa.�...... ., ....»...a..:(�. ��,as.�'.m .�t1le�...?.�.m._.7�..,�.�..: w.....- n s"i BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications Contact Us ' BCIS Site Map Links Search dI 14 :14 Product Approval 0i- , r •USER:Public U 1 � ser 9 i Pmrlur t AuDrnval Mem'>Product or Annlication Search>Application List>Application History>Application Detail �� (ti •_ t 7 G n'D 0 wA FL# FL22363-R4 m a 1 O Application Type Editorial Change o Code Version 2017 -?.,,,..1 Application Status Approved 3 *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived 0 . ' Product Manufacturer s Masonite International • Address/Phone/Email 1955 Powis Road West Chicago, IL 60185 (800) 663-3667 �` sschreiber@masonite.com i Authorized Signature Steve Schreiber sschreiber@masonite.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email b" • Category Exterior Doors J'0 Subcategory Swinging Exterior Door Assemblies { Compliance Method Certification Mark or Listing 4/ ortai • Certification Agency National Accreditation &Management Institute Validated By National Accreditation&Management Institute •• Referenced Standard and Year(of Standard) Standard ar ASTM E1886 2005 ASTM E1996 2009 ASTM E330 2002 TAS 202 1994 =`I Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A i Date Submitted 12/10/2018 Date Validated • 12/11/2018 Date Pending FBC Approval Date Approved 12/11/2018 r � Summary of Product's s f FL# 'Model,Number or Name I Description 22363.1 Fiberglass Side-Hinged Door Unit 6'-8" Opaque I/S Single Door Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes Fl 22363 R4 C CAC NI013717.17-R2.odf • • I Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date I Impact Resistant: Yes f 05/31/20211 Design Pressure: +60/-65 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22363 R4 II FI 0187.pdf Building Code, including the High Velocity Hurricane Zone, and I Verified By: National Accreditation &Management Institute where pressure requirements do exceed the design pressures Created by Independent Third Party: listed. 3'-0" x 6'-8" max nominal size. Hurricane protective Evaluation Reports system required in HVHZ, but not in the Wind Borne Debris FL22363 R4 AE 514010A.pdf Region. See DWG-MA-WL0187 for details. I FL22363 R4 AE 514014A.odf Created by Independent Third Party: Yes 22363.2 Fiberglass Side-Hinged Door Unit I 6'-8" Opaque 0/S Single Door Limits of Use Certification Agency Certificate 1 Approved for use in HVHZ:Yes FL22363 R4 C CAC NI013717.17-R2.odf 1 Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 05/31/2021 Design Pressure: +60/-60 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22363 R4 II • FL0187.pdf Building Code, including the High Velocity Hurricane Zone, and Verified By: National Accreditation &Management Institute where pressure requirements do exceed the design pressures Created by Independent Third Party: listed. 3'-0" x 6'-8" max nominal size. Hurricane protective Evaluation Reports system required in HVHZ, but not in the Wind Borne Debris FL22363 R4 AE 514010A.odf Region. See DWG-MA-WL0187 for details. FL22363 R4 AE 514014A.pdf Created by Independent Third Party: Yes 22363.3 ; Fiberglass Side-Hinged Door Unit 6'-8"Opaque I/S or 0/S Single or Double Door w/or w/o Sidelites Limits of Use j Certification Agency Certificate Approved for use in HVHZ: Yes I FL22363 R4 C CAC NI013717,17-R2.odf • Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 05/31/2021 Design Pressure: +50/-50 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22363 R4 II FL0187.pdf Building Code, including the High Velocity Hurricane Zone, and Verified By: National Accreditation &Management Institute where pressure requirements do exceed the design pressures Created by Independent Third Party: listed. 12'-0" x 6'-8" max nominal size. Hurricane protective Evaluation Reports { system required in HVHZ, but not in the Wind Borne Debris FL22363 R4 AE 514008A.odf Region. See DWG-MA-WL0187 for details. FL22363 R4 AE 514012A.odf Created by Independent Third Party: Yes 22363.4 I Fiberglass Side-Hinged Door Unit 6'-8" Glazed I/S or 0/S Single or Double Door w/or w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22363 R4 C CAC NI013717.03-R2.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date ' Impact Resistant: No 05/31/2021 Design Pressure: +40/-40 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22363 R4 II FL0189.pdf Building Code, including the High Velocity Hurricane Zone, and Verified By: National Accreditation &Management Institute ' where pressure requirements do exceed the design pressures Created by Independent Third Party: listed. 12'-0" x 6'-8" max nominal size. Hurricane protective Evaluation Reports .; ;system required in HVHZ and the Wind Borne Debris Region. FL22363 R4 AE 514008A.odf See DWG-MA-WL0189 for details. FL22363 R4 AE 514012A.odf Created by Independent Third Party: Yes 22363.5 ! Fiberglass Side-Hinged Door Unit 16'-8" 3/4-Lite Glazed I/S or 0/S Single or Double Door w/or w/o Sidelites Limits of Use Certification Agency Certificate } A• pproved for use in HVHZ: Yes FL22363 R4 C CAC NI013717.04-R2.odf I ; Approved for use outside HVHZ: Yes i Quality Assurance Contract Expiration Date Impact Resistant: No i 05/31/2021 Design Pressure: +50/-50 Installation Instructions Other: Evaluated',for use in locations adhering to the Florida FL22363 R4 II FLU193.odf BuildingCode, includin h g the High Velocity Hurricane Zone, and Verified By: National Accreditation & Management Institute 9 where pressure requirements do exceed the design pressures j Created by Independent Third Party: listed. 12'-0" x 6'-8" max nominal size. Hurricane protective I Evaluation Reports `_ system required in HVHZ and the Wind Borne Debris Region. FL2.2363 R4 AE 514008A.Ddf See DWG-MA-WL0193 for details. FL22363 R4 AE 514012A.Ddf Created by Independent Third Party: Yes •22363.6 1 Fiberglass Side-Hinged Door Unit 6'-8"Impact Glazed I/S or 0/S Single or Double Door w/or w/o Sidelites Limits of Use Certification Agency Certificate . Approved for use in HVHZ: No FL22363 R4 C CAC NI013717.05-R2,odf j Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 05/31/2021 Design Pressure: +50/-50 I Installation+Instructions Other: Evaluated for use in locations adhering to the Florida ( FL22363 R4 II FL0195.pdf Building Code, excluding the High Velocity Hurricane Zone, and Verified By: National Accreditation & Management Institute where pressure requirements do exceed the design pressures Created by Independent Third Party: listed. 12'-0"x 6'-8" max nominal size. Hurricane protective Evaluation Reports • ,"; system not required in the Wind Borne Debris Region. See FL22363 R4 AF 514008A,odf DWG-MA-WL0195 for details. FL22363 R4 AE 514012A.odf E Created by Independent Third Party: Yes 22363.7 ! Fiberglass Side-Hinged Door Unit 8'-0"Opaque I/S Single Door Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL22363 R4 C CAC NI013717.18-R1.pdf `; Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 05/31/2021 Design Pressure: +60/-65 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22363 R4 II FL0188.odf Building Code,including the High Velocity Hurricane Zone, and Verified By: National Accreditation& Management Institute where pressure requirements do exceed the design pressures Created by Independent Third Party: ',._• ; listed. 3'-0" x 8'-0" max nominal size. Hurricane protective Evaluation Reports ' k, system required in HVHZ, but not in the Wind Borne Debris FL22363 R4 AE 514009A.odf : Region. See DWG-MA-WL0188 for details. FL22363 R4 AE 514013A.odf Created by Independent Third Party: Yes 22363.8 Fiberglass Side-Hinged Door Unit 8'-0" Opaque 0/S Single Door Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL22363 R4 C CAC NI013717.18-R1.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 05/31/2021 Design Pressure: +60/-60 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22363 R4 II FL0188,Ddf `',` '..; + : Building Code, including the High Velocity Hurricane Zone, and Verified By: National Accreditation &Management Institute where pressure requirements do exceed the design pressures Created by Independent Third Party: listed. 3'-0" x 8'-0"'max nominal size. Hurricane protective Evaluation Reports .• system required in HVHZ, but not in the Wind Borne Debris FL22363 R4 AE 514009A.Ddf Region. See DWG-MA-WL0188 for details. FL22363 R4 AE 514013A.pdf Created by Independent Third Party: Yes 22363.9 , Fiberglass Side-Hinged Door Unit 8'-0 Opaque I/S or 0/S Single or Double Door w/or w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL22363 R4 C CAC N1013717.18-R1.odf Approved for use outside HVHZ: Yes (Quality Assurance Contract Expiration Date Impact Resistant: Yes 05/31/2021 ; Design Pressures +50/-50 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22363 R4 II FL0188.odf '- - F Building Code, including the High Velocity Hurricane Zone, and Verified By: National Accreditation & Management Institute where pressure requirements do exceed the design pressures Created by Independent Third Party: listed. 12'-0" x 8'-0i' max nominal size. Hurricane protective Evaluation Reports ' "' system required in HVHZ, but not in the Wind Borne Debris FL22363 R4 AE 514007A.odf i, - ' Region. See DWG-MA-WL0188 for details.. FL22363 R4 AE 514011A.odf i Created by Independent Third Party: Yes 22363.10 ) Fiberglass Side-Hinged Door Unit i 8'-0" Glazed I/S or 0/S Single or Double Door w/or w/o I L Sidelites Limits of Use 1 E Certification Agency Certificate Approved for use in HVHZ: Yes ( FL22363 R4 C CAC N1013717.08-R1,odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 05/31/2021 Design Pressure: +40/-40 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22363 R4 II FLO190.Ddf Building Code, including the High Velocity Hurricane Zone, and Verified By: National Accreditation &Management Institute where pressure requirements do exceed the design pressures Created by Independent Third Party: listed. 12'-0" x 8'-0" max nominal size. Hurricane protective Evaluation Reports system required in;HVHZ and the Wind Borne Debris Region. FI 2236 R4 0E 514007A.Ddf r - 'See DWG-MA-WL0190 for details. FL22363 R4 AE 514011A.Ddf Created by Independent Third Party: Yes 22363.11 ; Fiberglass Side-Hinged Door Unit 18'-0" Impact Glazed I/S Single or Double Door w/or w/o I Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL22363 R4 C CAC N1013717,09-R1,pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date "t Impact Resistant:Yes 05/31/2021 Design Pressure: +40/-45 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22363 R4 II FL0196.Ddf Building Code, excluding the High Velocity Hurricane Zone, and Verified By: National Accreditation &Management Institute where pressure requirements do exceed the design pressures Created by Independent Third Party: listed. 12'-0" x 8'-0" max nominal size. Hurricane protective Evaluation Reports system not required in the Wind Borne Debris Region. See FL22363 R4 AE 514007A.Ddf DWG-MA-WL0196 for details. FL22363 R4 AE 514011A.Ddf Created by Independent Third Party: Yes 22363.12 {Fiberglass Side-Hinged Door Unit 1 8'-0"Impact Glazed 0/S Single or Double Door w/or w/o Sidelites f ; Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL22363 R4 C CAC NI013717.09-R1,Ddf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 05/31/2021 Design Pressure: +45/-40 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22363 R4 II FL0196,Ddf Building Code, excluding the High Velocity Hurricane Zone, and Verified By: National Accreditation& Management Institute where pressure requirements do exceed the design pressures Created by Independent Third Party: I listed. 12'-0" x 8'-0" max nominal size. Hurricane protective Evaluation Reports system not required in the Wind Borne Debris Region. See FL22363 R4 AE 514007A.Ddf I DWG-MA-WL0196 for details. FL22363 R4 AE 514011A,.pdf Created by Independent Third Party: Yes 22363.13 I HPC Fiberglass Side-Hinged Door Unit 8'-0" Glazed I/S or 0/S Single or Double Door w/or w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL22363 R4 C CAC NI013717.07 R1.Ddf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 05/31/2021 Design Pressure: +47/-47 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22363 R4 II FL0192,Ddf Building Code, including the High Velocity Hurricane Zone, and Verified By: National Accreditation &Management Institute where pressure requirements do exceed the design pressures Created by Independent Third Party: listed. 12'-0" x 8'-0" max nominal size. Hurricane protective Evaluation Reports system required in HVHZ and in the Wind Borne Debris Region. FL22363 R4 AE 514007A.Ddf Door top rails stamped "HPC". See DWG-MA-WL0192 for FL22363 R4 AE 514011A.Ddf details. Created by Independent Third Party: Yes 22363.14 i HPC Fiberglass Side-Hinged Door Unit 6'-8"Glazed I/S or 0/S Single or Double Door w/or w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22363 R4 C CAC NI013717.02-R?.ndf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 05/31/2021 Design Pressure: +50/-50 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22363 R4 II FLO191.odf Building Code, including the High Velocity Hurricane Zone, and Verified By: National Accreditation &Management Institute ;where pressure requirements do exceed the design pressures Created by Independent Third Party: listed. 12'-0" x 6'-8" max nominal size. Hurricane protective Evaluation Reports j system required in HVHZ and the Wind Borne Debris Region. FL22363 R4 AE 514008A.pdf r . Door top rails stamped "HPC". See DWG-MA-WL0191 for FL22363 R4 AE 514012A,Ddf !details. Created by Independent Third Party: Yes NOTICE OF PRODUCT CERTIFICATION siva cal?T/pc�rz � • o , ,,,,' . oy-, Company: Masonite International Corporation Certification No.: N1013717.04-R2 G�4'� '''r,, 1)- -\\ 1955 Powis Road Certification Date: 05/12/2017 j �!x West Chicago, IL 60185 Expiration Date: 05/31/2021 4r..)V1® Revision Date: 05/02/2018 �'�,, �" ,.�� Product: Fiberglass Glazed Inswing or Outswing Door w/and w/o Non-Impact Rated Sidelites ,4PEL Aws.o•,,s6:, 3/4 Lite of Less Doors w/and w/o Full-Lite or Less Sidelites (w/Wood Frame or Worldwide Composite Frame' unless noted) Specification: TAS 202-94/ASTM E330-02 Glazing: Insulating Glass (Tempered) The"Notice of Product Certification"is only valid if the NAMI Certification Label has been applied to the product as described within this document. The certification label represents pr-oduct_conformity to the applicable specification and that all certification criteria has been satisfied.(This product has been approved for listing within NAMI's Certified-Product-Listing at www.i\anticertification.cmn. NAMI's Certification Program is accredited b _The American National Standards Institute(ANSI). Inswing Glazed Structural Water Missile Test Report Number Configuration or or Maximum Design Test Impact Drawing Number& Outswing Opaque Size Pressure Pressure Rated Comments X I/S Glazed 3'0"x 6'8" +50/-50 0.0 psi No ATLNC 1012.01-16R Single 3/4-Lite Max Maximum Panel Size:3'0"x 6'8" X 0/S Glazed 3'0"x 6'8" +50/-50 3.75 psi V6.0 psf' No ATLNC 1012.01-I6R/W-I813/W-1843/W-1860 Single 3/4-Lite Max 8.25 psf'/9.0 psi" Maximum Panel Size:3'0"x 6'8" 7.5 psf�' Anchor Details-DWG-MA-FLO193-17 Double 3/4-Lite Max Maximum Panel Size:3'0"x 6'8" Anchor Details-DWG-MA-FLO193-17 XX 0/S Glazed 6'0"x 6'8" +50/-50 3.75 psf'/6.0 psf' No ATLNC 1012.01-16R/W-1813/W-1843 Double 3/4-Lite Max 8.25 psf 3/8.25 psf' Maximum Panel Size:3'0"x 6'8" Anchor Details-DWG-MA-FL0193-17 XO/OX I/S Glazed 6'0"x 6'8" +50/-50 0 psi Door-No ATLNC 1012.01-16R Single w/Sidelite 3/4-Lite Max Sidelite-No Maximum Panel Size:3'0"x 6'8" Full-Lite Max S/L Anchor Details-DWG-MA-FLO193-17 XO/OX 0/S Glazed 6'0"x 6'8" +50/-50 3.75 psf'/6.0 psf'- Door-No ATLNC 1012.01-I6R/W-1813/W-1843 Single w/Sidelite 3/4-Lite Max 8.25 psf 3/9.0 psf' Sidelite-No Maximum Panel Size:3'0"x 6'8" Full-Lite Max S/L Anchor Details-DWG-MA-FLO193-17 OXO 1/S Glazed 9'0"x 6'8" +50/-50 0 psi Door-No ATLNC 1012.01-16R Single w/Sidelites 3/4-Lite Max Sidelites-No Maximum Panel Size:3'0"x 6'8" Full-Lite Max S/L Anchor Details-DWG-MA-FLO193-17 OXO 0/S Glazed 9'0"x 6'8" +50/-50 3.75 psf'/6.0 psf2 Door-No ATLNC 1012.01-16R/W-1813/W-1843 Single w/Sidelites 3/4-Lite Max 8.25 psf'/9.0 psf' Sidelites-No Maximum Panel Size:3'0"x6'8" Full-Lite Max S/L Anchor Details-DWG-MA-FLO193-17 OXXO I/S Glazed . 12'4"x 6'8" +50/-50 0 psi Door-No ATLNC 1012.01-16R Double w/Sidelites 3/4-Lite Max Sidelites-No Maximum Panel Size:3'0"x 6'8" Full-Lite Max S/L Anchor Details-DWG-MA-FLOI93-17 OXXO 0/S Glazed 12'4"x 6'8" +50/-50 3.75 psf'/6.0 psf'- Door-No ATLNC 1012.01-16R/W-1813/W-1843 Double w/Sidelites 3/4-Lite Max 8.25 psf 3/8.25 psi' Sidelitse-No Maximum Panel Size:3'0"x 6'8" Full-Lite Max S/L Anchor Details-DWG-MA-FL0193-17 1-Denotes Bumper Outswing Threshold 2-Denotes Z-Series Outswing Threshold 3-111-Dam Outswing Threshold 4-w-1815 5-Worldwide Pro T4 Threshold 6-Denotes HP Outswing Threshold National Accreditation & Management Institute, Inc./4794 George Washington Memorial Highway/Hayes, VA 23072 Tel: (804)684-5124/Fax: (804)684-5122 NAMI AUTHORIZED SIGNATURE: de • 00 1 MASO SITE. ,_ 149'MAX. OVERALL FRAME WIDTH ._ .....�... _ IX 21" MAX 35.375" MAX. 21" MAX 0 3/4-LITE FIBERGLASS DOOR UNIT -D.L.O.-.- ; ---PANEL WIDTH-I ----D.L.D. --i 37 D„ MAX. "� 0- 6-8"DOUBLE DOOR WITH/WITHOUT SIDELITES _ V1/ASTRAGAL FRAME WIDTH L� ..... - F= j ' ' z GENERAL,J 07t.$ _. �, l _...........__ _ CS ' it � ! wO ¢ 1. EVALUATED ORI FGR USE IN LOCATIONS HEADHERING TO I-- 4 U THE FLORIDA BUILDING CODE AND WHERE PRESSURE r f REQUIREMENTS AS DETERMINED BY ASCE 7, MINIMUM 1 DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, ___ W lf')(Sj DOESTIOT EXCEED THE DESIGN PRESSURES IFATED I X I. o I_:' U7 2. WHEN INSTALLED IN THE HIGH VELOCITY HURRICANE ZONE (HVHZ). °T f li C7 N 0 I-- HURRICANE PROTECTIVE SYSTEM (SHUTTERS) IS REQUIRED. -d I " u) <-•(n X h d I Q LL.1 3. WHEN INSTALLED IN THE WIND-BORNE DEBRIS REGION, ' -0-HURRICANE PROTECTIVE SYSTEM (SHUTTERS) IS REQUIRED. w `s"'Q I 0 Z 4. POLYURETHANE CORE FLAME SPREAD INDEX OF 50 z N)-) 1 '� - AND SMOKE DEVELOPED INDEX OF 60 PER ASTM EB4. g `�V) I I � 'e I` I ':.t �� i 5. PLASTICS TESTING: _111 _ a TEST DESCRIPTION DESIGNATION FACING LITE FRAME t I SELF IGNITION TEMP 1 ASTM D1929 752 'F > 650 'F 842 'F > 650 'F .. . Q a z"' RATE OF BURNING ASTM D635 I 0.56 IN/MIN , 1.28 IN/MIN _ a 1 •SMOKE DENSITY ASTM D2843 53.4% 70.2% 1 I _ + 0 $ m z .............. to W W TENSILE STRENGTH. ASTM D638 , 3.2% DIFF 1.8% DIFF f + �. .r-.-.--- 6. PLASTICS TESTING OF WORLDWIDE COMPOSITE FRAME (WHERE USED): I I o o e c-s TEST DESCRIPTION DESIGNATION RESULT -'- - --- --- - �1 o o[ j SELF IGNITION TEMP ? ASTM D1929 779 'F > 650 'F ' �. RATE OF BURNING i ASTM D635 0.0 IN/MIN SMOKE DENSITY I ASTM 02843 39.0% DOUBEE � LE_DOOR UNIT W/SjQEUI � 4 TENSILE STRENGTH. 1 ASTM D638 3.6% DIFF I } • COMPARATIVE TENSILE STRENGTH AFTER WEATHERING NLn m • •• -• r '•• ARC METHOD 1 , F.-.=] 11 7 re7 ,__ , , 1-7, , , . . , ,_< . , i < , . • 1 I '•1 0.---0 " • 'h 'B j' B®( e• !_ _ ' n- In I Zp Z fo)- m ilQ n co-I I cam , GL SINEOO DR Q JJT DOUBLE 000RJJN1T SINGLE DOOR UNIT SINOLE...009W UNIT SINGLE DOOR UNIT W/SIOELLTE$ DOUBLE DOOR UNIT WISIDELITE$ �V¢ WITH SIDELITE .W2TJj....S 12 tT" 10.o WHERE WATER INFILTRATION PERFORMANCE IS - DESIGN PRESSURE RATING REQUIRED TO BE 15% OF DESIGN PRESSURE IllffiniallingaMall INSWING OUTSWING INSWING BUMPER 0/S Z-SERI 0/S HP 0/S T4 0/S HIGH DAM 0/S +5Q.0 -50.0 +50.0 +50.0 ' N/A +25.0 / -25.0 +40.0 -40.0 +50.0 /-50.0 +50.0 ? -50.0 I+50.0 . -50.0 m,4 2 XX 74' 3+50.0 / -50.0 . / - N/A +25.0 / -25.0 ,+40.0 / -40.0 I N/A +50.0 / -50.0 j+50.0 /` -50.0 It ' ll OX or XO 75 +50.0 -50.0 +50.0 -50.0 _N'`AA +25,0 / -25.0 ±400 t -40.0 , N/A i+50.0_1 -50.0 •+50.0 / -500.0 I OXO 112.5 +50.0 -50.0 +50.0 -50.0 .. N A _ +25.0 / -25.0 +40.0 / -40.0 I N/A +50,0 7-50.0 '+50.0 / -50.0 ? ATE 4�26�7 7 - { OXXO I 149 f+50.0 / -50.0 +50.0 / -50.0 N/A _j+25_0 /.-25.0 _+40.0 / -40.0 M _ N/A. +50.0 .7 -50.0 +50.0 / -50.0.j .i 49 scu& N.T.S. TABLE OF CONTENTS AdC10114001‘014 (2. DWG.IW. SWS ShiEET # DESCRIPTION CHK.BY: -----........._._. . p f KURT BAL1HAZOR 1 TYPICAL ELEVATIONS & GENERAL NOTESCeffeaSoako, x: DRAWING NO.: RaZNI3 FLORIDA P.E. 2_._ ANCHORING LOCATIONS & DETAILS pLOW&Ly _ #56533 DWG-MA-FL0193-17 3 ANCHORING LOCATIONS &DETAILS ....--...-_.-. SHEET 1 OF 3 CC 6"- -• SEE DETAIL _3„ --j - 6" UO E "E" 3" 3 - 3^ 3„ 3rE Q J ti I I I I I —� I I I -I� 1 r r c)6 In r!...7-1----i---i 1j W0CC Q 11 I f- 4 U 3" z Z _ M —. I F —. *O. M. L.1.1 (-) id 1 T-- , Q a 7 r,M I... a O. LCL SEE DETAIL I j . ppik / � a 2 01 I' SEE DETAIL o "C" - O I W aLL, [T. I - SEE DETAIL " M 8 it B ! o :_ tir 0 0 3 M Y' � H z 1 - -6" 3" I aRR `"2, o a trit ,-I 11 i I r 6" 6"1 i 1 `� m 1 • s § wz 3 - - - yi- 3- €e i I I I I o of 7d 3" -H?--3" f f-3" - I_..3„6^ L f 3” 6" -I t---6" w a) s^- (C` a SEE DETAIL J / #8 x 2" I IN En 111,11 • r' • ASTRAGAL RETAINER BOLT HOLE #8 x 2" #10 X 5/8" 1 / GH CO Li) THE TUST HRESE DHOLD &RILLED T NTOUTHE f / STRUCTURE DEEP ENOUGH Q I #10 x 5/8" 1� "E" FOR 1.375" THROW o #8 x 2" *� #10 x 1" DETAIL ASTRAGA( a. <n #10 x 2-1/2" • ATTACH ASTRAGAL RETAINER BOLT DETAIL "F" ASTRAGAL =w zz 417'17 / '� #10 x 1" STRIKE PLATE TO FRAME w¢ 0 #10 x 5/8" 1 AS SHOWN. a R. Z. DETAIL "C" DETAIL "D" r OR 1/2•MLA=GLASS r 0a 1/2'wseuTED CLASS CO Al DEiCRAAL)MERE CECCRATIYE w9RT H 1:;r.■r; 0.962Ensmi .,,111'I� (01x4-Toga. Eumwcx�•..I' r--(m MAP. j N o 1.375" :� �;� T 1.437" r�.�„�Oe x 1-1/2•pHs A+..k. /e x 1'TTS T T'�// /ii iii//i.. ',1...:41,1!.......L:14%...,./.• "'•lit OR YEfN.SPACER •• —� FMN.OR YEW.SPN1R •t 1. RUM.FIIW. MSS mat t� '^• 1/2 - MT MELT/ �.v 1/Y ERIE III¢O INSWING THRESHOLC BUMPER 0/S THRESHOLD HP 0/S THRESHOLD �• ENSTMABi z I ELS „'I LIMB ]GEB� �'• �� H J 1 TYPICAL GLAZING DETAIL ALTERNATE GLAZING DETAIL DATE' 4/26/17 ii NON-IMPACT GLASS NON-IMPACT GLASS SCALE, N.T.S. 7.482" 1.76x" 11.047" 1,431^ J DWG.BY: SWS T I T Addeo:ant:Wm COX.BY: I)cBPW t/ DRAWING NO.: — Z-SERIES 0/S THRESHOLD HIGH DAM OjS THRESHOLD T4 OIS THRESHOLD 43' 7 DWG-MA-Fl.O1B3-17 ____ SWEET 2 OF 3 in SEE DETAIL -I 0 E" SHf 2_� ' 3"1 3"_- - 3 " 0 P. s" m m z s cp o Q h I.... N .." I it . k. ,u I o n ca v q ' i w " I a P 0 �h CD a SEE DETAIL ' : a t[� — — - r „D.' SHT. - - r (I) F � Q ,,.,SEE DETAIL i ui 0w - w C" SHT. 2 - �q>__.' X 10 1 ce(:-.5>- IR -- r- 6- , T ?3S r Lt • 3" AM�Y 3" - 6 s„ 3 T8 cr PAdeN}mPoNA4A A 3" 3„ - 3,.fi" a SEE DETAIL _/' a DARN' HARDWARE SCHEDULE VI VIr ATTACHMENT DETAIL 1. KWIKSET SERIES 400 GRADE 3 CYLINDRICAL LATCH AND vii v'm SERIES 980 GRADE 1 DEADLOCK HARDWARE TO BE INSTALLED 1. ANCHOR ANALYSIS FOR LOADING CONDITIONS PREPARED, AT 5-1/2" CENTERLINE. SIGNED AND SEALED BY ROBERTO LOMAS, PE ' ---_--;'',7.--71\r—r"—''—.1 2. 4" X 4" FULL MORTISE BUTT HINGES. Q (FLORIDA #62514) WITH THE LOWEST (LEAST) MIN i > `.� ' . .2s" i"xt/2" CORRUGATED iox2" WOOD SCREW �a FASTENER RATING FROM THE DIFFERENT FASTENERS 1 SHIM 3" FROM EACH ENE 6 FROM EACH END a o BEING CONSIDERED FOR USE. JAMB, HEAD, AND >M2 IMOM AND �" OC AND 12" OC THRESHOLD FASTENERS ANALYZED FOR THIS UNIT INCLUDE CL-I I- p a o #10 WOOD SCREWS, 1/4" TAPCONS, AND #10 TEK SCREWS. ...Atv �-= 1" —0.25 - t'' SHIM ' ` ACRYLIC ¢a. x A PHYSICAL SHIM MUST BE PLACED IN SHIM SPACE AT EACH LAT- LATEX , ANCHOR LOCATION. TAPCON EDGE DISTANCE MIN 2-1/2". cL_( (_ h CAULK __.! AMC � WOOD SCREW EDGE DISTANCE MIN 3/4". TEK SCREW EDGE TYPICAL MASONRY *I'-DISTANCE MIN 1/2". ANCHOR INSTALLATION r CAULK (_CL N'N c a 2. ANCHORING INTO STEEL STRUCTURE MUST BE SUFFICIENT TO r 1X BUCK MASONRY COMBINATION WOOD COMBINATION WOOD to�� ACHIEVE 3 THREADS MINIMUM BEYOND STEEL INTERIOR SURFACE. `" p - , ANCHOR INSTALLATION MULLION (BOXED) MULLION (BOXED) IMIN 1 0.25 3. THE WOOD SCREW SINGLE SHEAR DESIGN VALUES COME FROM + MAx .. 3)' #10x2-1/2" (4) #10x2-1/2" maw WOSCREWS WOOD SCREWS ANSI/AF&PA NDA FOR SOUTHERN PINE LUMBER AND ACHEIVEMENT L. �-'- SHIM EACH END EACH END ! ! OF 1-1/2" MINIMUM EMBEDMENT. THE TAPCON MUST ACHIEVE CL-I I--- '46Nit ® DATE: 4/26/17 MINIMUM EMBEDMENT OF 1--1/4". a ! ® SCALE: N.T.S. DWG.BY: _SWS 4. WOOD BUCKS BY OTHERS MUST BE ANCHORED PROPERLY TO 0I li UUU S®: CNK.@Y: TRANSFER LOADS TO STRUCTURE. TYPICAL WOOD BUCK DRAWING NO.: 5. MINIMUM DESIGN VALUE STRENGTH OF ANCHORS 155 LBS. ANCHOR INSTALLATION INTEGRAL WOOD INTEGRAL WW DwG-MA-f1D193-17 MULLION (CHS) MULLION (CHS) SHEET 3 OF 3 i L.'Roberto Lomas P.E. 1432 Woodford Rd I Manufacturer: Masonite Lewisville.NC 27023 Report#: 514008A 434-688-0609 Date: 10/10/2017 rllomas(rJlrlomaspe corn Test Report: N/A Product: Double Door with and without sidelites 12'x6'8"(wood frame) Scope: This analysis provides calculations,quantities,and spacing requirements for installing product to substrate,and it applies only to the product described herein.These calculations comply with requirements of the Florida Building Code. Anchor capacity in shear condition: Solid members w/&w/out gap: a. With threads present in shear plane Fastener type:#10 wood screw (NDS 2012,ND5 2015,TR12) Nominal diameter: D: 0.190 in Gap: g: 0.0000 in Root diameter: Dr: 0.152 in Moment arm: 0.0000 in Minimum required penetration: p: 1.140 in Screw bending yield strength: Fy,= 80,000 psi Side member: Douglas Fir-Larch(G=0.50) Main member: Spruce-Pine-Fir(G=0.42) Side member thickness: t,= 1.000 in Main member thickness: t„= 1.500 in Side member dowel bearing strength: F,.,= 4,650 psi Main member dowel bearing strength: ' F,,,= 3,350 psi Side member dowel bearing length: I,= 1.000 in Main member dowel bearing length: I,n= 1.140 in Mode I,, Mode I, Mode II Mode III,, Mode III, Mode IV gm= 636.5 lbs/in qs= 884 lbs/in A: 0.0007 A: 0.00096 A: 0.00107 A: 0.00135 P= 725.61 lbs P= 884 lbs B: 1.07 B: 0.57 B: 0.5 8: 0.000 • ' Ko= 2.400 Ka= 2.400 C: -427.674 C: -253.623 C: -267.699 C: -93.6 Z,,= 302 lbs Z,= 368 lbs P= 331 lbs Ms= 46.8 in-lbs Mm= 46.8 in-lbs Ka= 2.400 P= 297 lbs P= 319 lbs P= 263 lbs Min.Design value: Z. 110 lbs Z= 138 lbs Kt,= 2.400 Kr,= 2.400` Kr,= 2.400 Duration Factor: Cr,= 1.6 Z= 124 lbs Z= 133 lbs Z= 110 lbs Allowable Design Value(ZC0): Z'= 175 lbs/anchor Fastener type: 1/4 ITW Tapcon Tabulated values N.O.A.16-1222.06 edge spacing(in) Substrate: Hollow block distance 2.00 4.00 Minimum embedment: 1.25 in 2.00 130 161 Actual edge distance: 2.50 in 4.00 163 202 Actual C To C spacing: 3.00 in Allowable Design Value: Z"= 155 lbs/anchor(per interpolation when needed) Fastener type: #10 Tek screw Substrate: 18 GA,Steel Tabulated design value: Z= 1266 lbs Safety factor: F5= 4 Allowable Design Value(ZF5): Z'= 316 lbs/anchor Minimum anchor capacity: 155 lbs/anchor Note:Anchors with the least capacity is used for calculations to qualify anchors with higher capacity. Anchor calculations,minimum required anchors 36.38 36.38 Design pressure: 60.0 psf t I t Max. Anchor t At •••••• Al / Area Load Ind. Aa Zone Z O.C. Cap. Load Result Az 1 -YAz 79.25 (ft) (lbs) (in) 4ty Aa (in) (lbs) (lbs) i Al v Al N AI 2.3 138 N/A N/A 155 1 138 OK I. 3, A2 7.7 463 6.00 21.00 155 5 93 OK 72.75 A3 7.7 463 N/A N/A 155 3 154 OK 37.50 36.38 36.38 37.50 Design pressure: 60.0 psf • \\0\11111 II�',�l� y t 'I t Max. Anchor / Al n A4 ! A4 Al -` Area ' Load Ind- �`�S .�. , .v,,,./% Zone Z O.C. Cap. Load Result \ J • Y A3 Y A5 Y A3 Y (ft) (lbs) (in) (in) (lbs) Qty (lbs) �/,• \C+ N S •�(� �� - Az .. F • 79.25 Ai 2.4 146 N/A N/A 155 1 146 OK *. _p 3 •. Al v A v A4 v Al \ A2 7.9 473 6.00 21.00 155 5 95 OK • C/ A3 7.8 468 N/A N/A 155 4 117 OK 147.75 A4 2.3 138 N/A N/A 155 1 I38 OK 7:13 • TAT OF • A5 7.7 463 N/A N/A 155 3 154 OK %0 • R/ 1 A. • ss. !��/S"ONAL, .- Luis R. Lomas P.E. FL No-: 62514 1 of 4 10/10/2017 ' L.'Roberto Lomas P.E. 1432 Woodford Rd. Manufacturer: Masonite Lewisville.NC 27023 Report#: 514008A 434.688-0609 Date: 10/10/2017 rl lomas(a rlomaspe.cons Anchor Locations: Double door 36.38 36.38 6.00 TYP. 6.00 TYP. 18.19 TYP. 3.00 TYP.-- 6.00 I I I I 1 I I I T- 18° MAX O.C. 79.25 6.00 } I 1 I I f I I I ,\\ \ I• • • • • • _ iii • o TAT OF • 0 ���`'•CORIDP. ` ii110 Luis R. Lomas P.E. FL No.:62514 2 of 4 10/10/2017 L.'Roberto Lomas P.E. 1432 Woodford Rd. Manufacturer Masonite Lewisville.NC 27023 . Report#: 514008A 434-688-0609 Date: 10/10/2017 rliomasflrlomaspe.com Double door with sidelites 37.50 36.38 36.38 37.50 18.75 TYP. 6.00 TYP. 6.00 TYP. 18.19 TYP.—.. 3.00 TYP.— -••— i 1 I I I I I I I I I I I I I I I I 1 I 6.00 18' MAX O.C. 79.25 • 6.00 I I I I I I I I I I -I I I I I I I I ,x\lltiiii//// 04, • ■ -�} • -- w TAT OF • / ,� � 616% 0 R 10 G�is�. • *hiONAt`E`\\\\ • Luis R. Lomas P.E. FL No.: 62514 3 of 4 10/10/2017 L. Roberto Lomas P.E. 1432 Woodford Rd. Manufacturer: Masonite Lewisville.NC 27023 Report#: 514008A 434.688-0609 Date: 10/10/2017 rliomasi Irlomaspe.con • 1. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE#10 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4"MINIMUM EMBEDMENT INTO SUBSTRATE WITH 1/2" MINIMUM EDGE DISTANCE.LOCATE ANCHORS AS SHOWN BELOW. c. I VIX F111l.1 IUrslI' I '7r•RHIVIC IN IV IVIAJUINK r/UlfMA-CC IC UJC I/4 IHF'I.UINJ VVI I FI SUFFICIENT LENGTH TO ACHIEVE A 1 1/4"MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" MINIMUM EDGE DISTANCE.LOCATE ANCHORS AS SHOWN BELOW. • 3. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE#10 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL WITH 1/2"MINIMUM EDGE DISTANCE.LOCATE ANCHORS AS SHOWN BELOW. 4. ALL FASTENERS TO BE CORROSION RESISTANT. 5. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A.WOOD:MINIMUM SPECIFIC GRAVITY OF G=0.42 B.CONCRETE:MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI. C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2,000PSI MINIMUM. D. METAL STRUCTURE:STEEL 18GA(.048")FY=33KSI/FU=52KS1 OR ALUMINUM 6063-T5 FU=30KSI .052"THICK MINIMUM 6. ANCHOR LOCATIONS SHOWN IN THIS DOCUMENT ARE THE MINIMUM REQUIRED FOR THE DESCRIBED PRODUCT EXPOSED AT THE DESIGN PRESSURE INDICATED HEREIN. 7. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 8. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. 9. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2"UNITS MUST BE ANCHORED THROUGH FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO MASONRY,CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. 10. WHERE WOOD BUCK THICKNESS IS 1-1/2"OR GREATER,BUCK SHALL BE SECURELY FASTENED TO MASONRY,CONCRETE OR OTHER STRUCTURAL SUBSTRATE.UNITS MAY BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. 11. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE.SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 12. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS PROVIDED. Oil MN/ • •E • . �?,9�i .•� c1 N sF•s�% • TAT O F • ' E`S;:c10 R 1oP�sk- /,f CONALt iit ,;•\\\\ Luis R. Lomas P.E. FL No.: 62514 4 of 4 10/10/2017 •-- L..'Roberto Lomas P.E. 1432 Woodford Rd. Manufacturer: Masonite Lewisville.NC 27023 Report#: 514012A 434-688-0609 • Date: 10/10/2017 rllomasallrlomaspe.corn Test Report: N/A Product: Double Door with and without sidelites 12'x6'8"(composite frame) Scope: This analysis provides calculations,quantities,and spacing requirements for installing product to substrate,and it applies only to the product described herein.These calculations comply with requirements of the Florida Building Code. Anchor capacity in shear condition: Solid members w/8 w/out gap: a. With threads present in shear plane Fastener type:#10 wood screw (NDS 2012,NDS 2015,TR12) Nominal diameter: D: 0.190 in Gap: g: 0.0000 in Root diameter: Dr: 0.152 in Moment arm: 0.0000 in Minimum required penetration: p: 1.140 in Screw bending yield strength: Fyb= 80,000 psi Side member: PVC Main member: Spruce-Pine-Fir(G=0.42) Side member thickness: t,= 1.000 in Main member thickness: t,,,= 1.500 in Side member dowel bearing strength: Fe,= I0.000 psi Main member dowel bearing strength: F,,,,= 3,350 psi Side member dowel bearing length: 1,= 1.000 in Main member dowel bearing length: Im= 1.140 in Mode I,, Mode I, Mode II Mode III,,, Mode III, Mode IV qm= 636.5 lbs/in qs= 1900 lbs/in A: 0.0005 A: 0.00066 A: 0.00092 A: 0.00105 P= 725.61 lbs P= 1900 lbs B: 1.07 B: 0.57 8: 0.5 8: 0.000 KD= 2.400 Ka= 2.400 C: -681.799 C: -253.623 C: -521.824 C: -93.6 Zr", 302 lbs Zr, 792 lbs P= 510 lbs Ms= 46.8 in-lbs Mm= 46.8 in-lbs K8= 2.400 P= 324 lbs P= 529 lbs P= 299 lbs Min.Design value: Z= 125 lbs Z= 212 lbs Ko= 2.400 Kb= 2.400 Ko= 2.400 Duration Factor: Co= 1.6 Z= 135 lbs Z= 221 lbs Z= 125 lbs Allowable Design Value(ZCo): Z'= 199 lbs/anchor Fastener type: 1/4 17W Tapcon Tabulated values N.O.A.16-1222.06 edge spacing(in) Substrate: Hollow block distance 2.00 4.00 . Minimum embedment: 1.25 in 2.00 130 161 Actual edge distance: 2.50 in 4.00 163 202 Actual C To C spacing: 3.00 in Allowable Design Value: Z 155 lbs/anchor(per interpolation when needed) Fastener type: #10 Self tapping screw (Calculations per 2015 Aluminum Design Manual,section J.5.5) Nominal screw diameter: 0: 0.190 in Screw root area: Ar 0.0151 int Actual edge distance: de: 1.085 in Screw shear ultimate strength: F,,, 54.0 ksi Per table J3.2 of 2010 Steel Construction Manual 14th Edition Side member material: Vinyl PVC Main member material: 6063-T5 aluminum Thickness: t, 1.000 in Thickness: t2 0.052 in Ultimate tensile strength: F,,,, 14 ksi Ultimate tensile strength: F,,,2 22 ksi Nominal strength per bearing(side member): Rn=2Dt,Ft,,, Rnl= 5320 lbs (Eq J.5-12) Nominal strength per bearing(main member): Rn=2Dt2F,,,2 Rn2= 435 lbs (Eq J.5-12) Nominal strength per tilting: Rn=4.2(t23D)`y2Fm2 Rn= 478 lbs (Eq 3.5-13) Nominal screw shear strength: Rn=ArF,u/1.25 Rn= 654 lbs (Eq J.5-14) Safety factor: 0= 3 Allowable shear and bearing capacity: Pa 145 lbs/anchor Fastener type: #10 Self tapping screw (Calculations per AISI-5100-12,sections A2.3.2 and E4.3.1) Nominal screw diameter: 0: 0.190 in Screw shear ultimate strength: F,,, 54.0 ksi Screw root area: Ar 0.0151 int Per table J3.2 of 2010 Steel Construction Manual 14th Edition Side member material: Vinyl PVC Main member material: Metal framing Thickness: t, 1.000 in Thickness: t2 O.0"^ Ultimate tensile strength: F,,, 14 ksi Ultimate tensile strength: F„2 ,\01111///// Nominal strength per tilting: Rn=4.2(t23D)=y2F„2 Rn= 1001 lbs (Eq E4.3.1-I) \\ s R, L o ///� Nominal strength per bearing(side member): Rn=2.7Dt,F,,, Rnl= 7182 lbs (Eq E4.3.1-2 and-4) \\ _\\• • •C•l�•I . Nominal strength per bearing(main member): Rn=2.7Dt2F,,2 Rn2= 1280 lbs (Eq E4.3.1-3 and-5) .\V• \Cj G t s •�CP .� • • i Nominal screw shear strength: Rn=ArF,b/1.25 Rn= 654 lbs _� • • ,r Safety factor: 0=3 t *• 0 `�51 • *` Allowable shear and bearing capacity: P. 218 lbs/anchor - ' ((/,17yC`ynF'�j • Minimum anchor capacity: 145 lbs/anchor .7:13w p 'a i� TAT O F Note:Anchors with the least capacity is used for calculations to qualify anchors with higher capacity. �► • '�ss1ONAI E�G`�\ rniW Luis R. Lomas P.E. FL No.: 62514 1 of 4 10/10/2017 L.'Roberto Lomas P.E. 1432 Woodford Rd. 1 Manufacturer: Masonite Lewisville.NC 27023 Report#: 514012A 434-688-0609 Date: 10/10/2017 rllornasr Irlornaspe.com Anchor calculations,minimum required anchors 36.38 36.38 Design pressure: 60.0 psf t t • Max. Anchor \ Al Al Area Load Ind. Y as Zone (ft2) (Ibs) (in) O.C. Cap. 4 tY Load Result �AZ 79.25 (in) (Ibs) (Ibs) ✓ Al '' Al N. Al 2.3 138 N/A N/A 145 1 138 OK 1 ) A2 7.7 463 6.00 21.00 145 5 93 OK 72.75 A3 7.7 463 N/A N/A 145 4 116 OK 37.50 36.38 36.38 37.50 Design pressure: 60.0 psf t y t t I Max. Anchor Al /\ A4 /\ A4 l\ Al /.--.' Area Load Ind. Zone 2 O.C. Cap. Load Result Y A3 Y tai Y A3 Y (ft) (Ibs) (in) (in) (Ibs) GM (Ibs) A2� ro as ) j 79.25 Ar 2.4 146 N/A N/A 145 2 73 OK / Al U A4 v A4 ', Al \ A2 7.9 473 6.00 21.00 145 5 95 OK 1 I A3 7.8 468 N/A N/A 145 4 117 OK 147.75 A4 2.3 138 N/A N/A 145 1 138 OK A5 7.7 463 N/A N/A 145 4 116 OK Anchor Locations: Double door 36.38 36.38 6.00 TYP. 6.00 TYP. 18.19 TYP. 3.00 TYP.-a- 6.+o I I I I I I I I t + - 18° MAX O.C. I l 79.25 • 1 R. 6.00 I I I I I I I ��J\�\G E �• 9s:rep:. t I �' F *• 13 51 • *t= TAT OF -4,,z.- .....0.4.. �� • iE`ss� 0Rt� �G46$. *h�0NAI`�,\\\ Luis R. Lomas P.E. FL No.: 62514 2 of 4 I 10/10/2017 L.3Roberto Lomas P.E. 1432 Woodford Rd. Manufacturer: Masonite Lewisville.NC 27023 Report#: 514012A 434-688-0609 Date: 10/10/2017 rliornas(lrlornaspe.corn Double door with sidelites 37.50 - 38.38 36.38 37.50 �-18.75 TYP.—� 6.00 TYP. 6.00 TYP. 18.19 TYP. 3.00 TYP. 6.00 I ! I I I I I I 1 1 1 I I I I 1 1 18" MAX O.C. 1 79.25 6.00 I 1 I I I I 1 I l -I I I I I 1 I 1 1 �c, R. L 0 J � . . Z1,9/ice ••��GENS+F•c -- *40451 • yr TAT OF •�� s'aNAt11- litil`E Luis R. Lomas P.E. FL No.: 62514 • 3 of 4 10/10/2017 L.'Roberto Lomas P.E. • 1432 Woodford Rd. Manufacturer: Masonite Lewisville,NC 27023 Report#: 514012A 434-688-0609 Date: 10/10/2017 rllomasAlrlomaspe.con; • Installation instructions: 1. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE#10 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4"MINIMUM EMBEDMENT INTO SUBSTRATE WITH 1/2" MINIMUM EDGE DISTANCE.LOCATE ANCHORS AS SHOWN BELOW. 2. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 1/4"TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4"MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" MINIMUM EDGE DISTANCE.LOCATE ANCHORS AS SHOWN BELOW. 3. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE#10 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL WITH 1/2"MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW. 4. ALL FASTENERS TO BE CORROSION RESISTANT. 5. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A.WOOD:MINIMUM SPECIFIC GRAVITY OF G=0.42 B.CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI. C. MASONRY:HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2,000PSI MINIMUM. D. METAL STRUCTURE:STEEL 18GA(.048")FY=33KSI/FU=52KSI OR ALUMINUM 6063-T5 FU=30KSI .052"THICK MINIMUM 6. ANCHOR LOCATIONS SHOWN IN THIS DOCUMENT ARE THE MINIMUM REQUIRED FOR THE DESCRIBED PRODUCT EXPOSED AT THE DESIGN PRESSURE INDICATED HEREIN. 7. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE.FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 8. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. 9. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2"UNITS MUST BE ANCHORED THROUGH FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO MASONRY,CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. 10:WHERE WOOD BUCK THICKNESS IS 1-1/2"OR GREATER,BUCK SHALL BE SECURELY FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. UNITS MAY BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. 11. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE.SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 12. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS PROVIDED. • ,\\\1111110i \\ R• L 0 �2, 40, GENS 1 , TAT OF • - ju— �•' �OR10P. , iss.'ONAL .* . /liM Luis R. Lomas P.E. FL No.: 62514 4 of 4 10/10/2017