Loading...
HomeMy WebLinkAboutFL Product Approval UNDERLAYMENT TAMKO SYNTHETIC SHINGLE ROOFS12/20/2018 Florida Building Code Online Ale wa#t.' BC15 Nome Log In User. Registration Not Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search pr-)Product Approval JUSER: Public User Pra 1nrt Approv.il Mena > Pronur! or. AriplWation Ss. ai .h > Anpl caticw tisi > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Evaluation Entity Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code FL20853-R2 Revision 2017 Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. FT SyntheticsInc. 13120 76 Ave Unit 1 Surrey, NON -US 98225 (604)594-3439 rrobson@ftsyn.com Russ Robson rrobson@ftsyn.com Russ Robson 12179 86 Ave Surrey, NON -US 00000 (604) 594-3439 rrobson@ftsyn.com Roofing Underiayments Evaluation Report from a Product Evaluation Entity Intertek Testing Services NA, Inc. Intertek Testing Services NA, Inc. - QA'Entity 01/01/2020 Intertek Testing Services NA, Inc. Standard ASTM D226 Year 2009 Product Approval Method Method 1 Option C https://www:Horidabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgtbxPgODTr%2bX1°/o2fn2hm4SoV8T9TdomZjJ6ejBsbJRYLOVA°/a3d%3d 1/2 12/2012018 Florida Building Code Online Date Submitted 01/08/2018 Date Validated 01/10/2018 Date Pending FBC Approval Date Approved 01/14/2018 Summary of Products FL , .--- Model, Number or Name DeScriptivn' , 20853.1 FT Synthetics Roof Underlayments Synthetic hoofing UNeriayment Limits of Use Installation Instructi s Approved for use in HVHZ: Yes Fl_20853 R2 TI FT Synt tics Root rnderlayments tn1;taliatian Approved for use outside HVHZ: Yes Ingructions.pdf Impact Resistant: N/A Verified By: Intertek Tes g Services NA, Inc. Design Pressure: N/A Created by Independe Third Party: Other: Evaluation Report E-00853 R2 _ Ot$_U7=Q1 CCRR-10?fl.pdf Contact s :: 2601 Blair Stone Road, Tallahassee FL 3Z399 Phone: 850-487-1$24 The State of Florida is an AA/EEO employer. gQpwight 2007-2013 State of Florida ; : privacy Statement :: Accessibility Statement:: Refund Statement under Florida law, email addresses are public records If you do not want your e-mail address released in response to a public -records request, do not Send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395, *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 4S5, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a. personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S.,. please click here .. Product Approval Accepts- https://www.floridabuilding.org/prlpr app dti.aspx?param=wGEVXQwtDgtbxPgODTt%2bX1%2fn2hm4SoV8T9TdomZjJ6ejBsbJRYLOVA%3d%3d 2Q J,XF Installation Instructions: caution. Always follow Safety Instruction, Building Codes and Safe Work Practices issues by the local Govt. bodies (e.g. OSHA / WCB) FT Synthetics products should be installed with Plastics Cap or Metal Cap nails with either ring shank or smooth shank Nails. DO NOT USE STAPLES. Use of staples will void the Manufacturer's warranty, FT Synthetics products are a secondary layer protection approved for installation over Plywood with proper fasteners. FT Synthetics underlayment is an air, vapour and water barrier with <1 Perm. FT Synthetics underlayment is laid out horizontally with printed side up using 6" vertical laps and 4" horizontal laps. The overlaps ensure that the water runs over the overlaps without getting under the material. Before installing the underlayment ensure that the roof is clear of any debris or any sharp protrusions. Product must be attached to the roofing structure using 1" plastic or metal cap nails. Product must be fastened with the nail pattern printed on the product. All anchoring must be performed flush to the roof, 90 degrees to the roof deck that will hold the material tightly with the plywood. The use of every other anchoring location printed on the product is also acceptable. For prolonged exposure, double the overlaps and use every anchor location. Product has 90 Days UV protection but it should not be considered a final roofing system, A proper final roofing system should be installed over the product to get the proper protection. Product is a secondary barrier used over plywood, under a roofing system like wood and asphalt shingles and metal Safety Notification, FT Synthetics products are designed with the GRIPSPOT technology for better skid protection for the t rooter but product may become slippery dues to high moisture, frost, rain, water, dust, debris or other conditions. Use precautions when working on the roof. Follow all local and federal safety codes when installing any roofing system including FT Synthetics products. Failure to adhere to those procedures may result in serious injury or even death. FT SYNTHETICS Unit 1-13128 - 76th Avenue Surrey BC v3W 3H8 Canada Toll Free Ph: 1-844-353-9839 Phone: 604.594-3439 Fax:604-504.3689 www.ftsyn.com -1- Single Layer Application of FT SILVER For slopes greater that 4:12 FT SILVER should be installed horizontally starting from the bottom of the roof with a 4 inch overlaps working up the roof. Roof Deck-_-.-__­--- N. — — — — — — — — — - - - - --4 -------- 4" (100 mm) Horizontal Overlap 48- (122 cm) Eave Drip Edge Under Underlayment Rake Drip Edge Over Underlayment Fasten underlayment as specified in the installation instructions Double Layer Application of F7 SILVER For slopes 2:12 to 4:12 FT SILVER should be installed horizontally starting from the bottom of the roof with a 4 inch overlaps working up the roof, -oRoof Deck,-,,, W (122 cm) -7- 25" (64 cm) Eave Drip Edge Under Underlayment Rake Drip Edge Over Underlayment Phone: ZZZ; Unit 1-13120 - 76th Avenue �o FT SYNTHETICS Surrey BC V3W 3H8 Fax: 604-694-3689 Canada www.ftsyn.com -2- I V*1 JAFFI Installation Instructions: Caution: Always follow Safety Instruction, Building Codes and Safe Work Practicli issues by the local Govt. bodies (e.g. OSHA FT Synthetics products should be installed with Plastics Cap or Metal Cap nails with either ring shank or smooth shank Nails. DO NOT USE STAPLES. Use of staples will void the Manufacturer's warranty. FT Synthetics products are a secondary layer protection approved for installation over Plywood with proper fasteners. FT Synthetics underlayment is an air, vapour and water barrier with <1 Perm. FT Synthetics underlayment is laid out horizontally with printed side up using 6" vertical laps and 4" horizontal laps. The overlaps ensure that the water runs over the overlaps without getting under the material. Before installing the underlayment ensure that the roof is clear of any debris or any sharp protrusions. Product must be attached to the roofing structure using I" plastic or metal cap nails. Product must be fastened with the nail pattern printed on the product. All anchoring must be performed flush to the roof, 90 degrees to the roof deck that will hold the material tightly with the plywood. The use of every other anchoring location printed on the product is also acceptable. For prolonged exposure, double the overlaps and use every anchor location. Product has 180 Days UV protection but it should not be considered a final roofing system. A proper final roofing system should be installed over the product to get the proper protection. Product is a secondary barrier used over plywood, under a roofing system like wood and asphalt shingles, tiles, slate and metal roof. FT Synthetics products are designed with the GRIPSPOT technology for better skid protection for the roofer but product may become slippery due to high moisture, frost, rain, water, dust, debris or other conditions. Use precautions when working on the roof. Follow all local and federal safety codes when installing any roofing system including FT Synthetics products. Failure to adhere to those procedures may result in serious injury or even death. Unit 1 -13120 - 76th Avenue Q FT SYNTHETICS Surrey SC V3W 3H8 Canada Toll Free Ph: 1-844-353.9839 Phone: 604-594-3439 Fax: 604-594-3589 www.ft3yn.com -3- Single Layer Application of FT GOLD For slopes greater that 4:12 FT GOLD should be installed horizontally starting from the bottom of the roof with a 4 inch overlaps working up the roof. Eave Drip Edge Under Underlayment Double Layer Application of FT GOLD For slopes 2:12 to 4:12 FT GOLD should be installed horizontally starting from the bottom of the roof with a 4 inch overlaps working up the roof. ---Roof Deck: J ilRake Drip Edge Over Underlayment Eave Drip Edge Under Underlayment c� norm Unit 1.13120 - 76tn Avenue phone: 604 594-3439 FT SYNTHETICS surrey BC V3W 3H8 Fax:604-594-3589 Canada www.ftsyn.com -4- Synthetic Roofingne Installation Instructions: Always followaoCodes and Safe Practicel issues by the local Govt. bodies (eg. OSHA. % WC ) FT Synthetics products should be installed with Plastics Cap or Metal 'Cap nails with either ring shank or smooth shank Nails. DO NOT USE STAPLES. Use of staples will void the Manufacturer's warranty. FT Synthetics products are a secondary layer protection approved for installation over Plywood with proper fasteners. FT Synthetics underlayment is an air, vapour and water barrier with <1 Perm. FT Synthetics underlayment is laid out horizontally with printed side up using 6" vertical laps and 4" horizontal laps. The overlaps ensure that the water runs over the overlaps without getting under the material. Before installing the underlayment ensure that the roof is clear of any debris or any sharp protrusions. Product must be attached to the roofing structure using 1" plastic or metal cap nails. Product must be fastened with the nail pattern printed on the product. All anchoring must be performed flush to the roof, 90 degrees to the roof deck that will hold the material tightly with the plywood. The use of every other anchoring location printed on the product is also acceptable. For prolonged exposure, double the overlaps and use every anchor location. Product has 180 Days UV protection but it should not be considered a final roofing system. A proper final roofing system should be installed over the product to get the proper protection. Product is a secondary barrier used over plywood, under a roofing system like wood and asphalt shingles, tiles, slate and metal roof. Safety Notification, FT Synthetics products are designed with the C IPSPOT technology for better skid protection for the roofer but product may become slippery due to high moisture, frost, rain, water, dust, debris or ether conditions. Use precautions when working on the roof. Follow all local and federal safety codes when installing any rooming system including FT Synthetics products. Failure to adhere to those procedures may reSUlt in serious injury or even death. Q FT SYNTHETICS Unit 1-13120 - 76th Avenue Surrey BC V3W 3H8 Canada Toll Free Ph: 1-844-353-9839 Phone:604-594-3439 Fax:604-594.3589 www.ftsyn.com -5- Single Layer Application of FT PLATINUM For slopes greater that 4: 2 FT PLATINUM should be installed horizontally starting from the bottom of the roof with a 4 inch overlaps working up the roof. 6" (150 mm) ! Vertical overlap Eave Drip Edge Under Underlayment Rake Drip Edge Over Underlayment Fasten Underlayment as specified in the installation instructions Double Layer Application of FT PLATINUM For slopes 2:12 to 4:12 FT PLATINUM should be installed horizontally starting from the bottom of the roof with a 4 inch overlaps working up the roof. :_t---6Roof Deck -= o Eave Drip Edge Under Underlayment Rake Drip Edge Over Underlayment Fasten Underlayment as specified in the installation instructions n4 A OAA.4LR_001 unn 7-ijizu - toin iwenue Phone: 6o4-594-3439 Q FT SYNTHETICS Surrey BC V3W 3H8 Fax: 604-594-3589 Canada WWWASyn.com -6- BreathableSynthetic Underlayment Installation Instructions: Caution: Always follow Safety Instruction, Building Codes and Safe Work Practices issues by the local Govt. bodies (e.g./ FT Synthetics HYDRA should be installed with Plastics Cap or Metal Cap nails with either ring shank or smooth shank Nails. DO NOT USE STAPLES. Use of staples will void the Manufacturer's warranty. FT Synthetics HYDRA is a secondary layer protection approved for installation over Plywood with proper fasteners. FT Synthetics HYDRA underlayment is laid out horizontally with printed side up using 6" vertical laps and 4" horizontal laps. The overlaps ensure that the water runs over the overlaps without getting under the material. Before installing the underlayment ensure that the roof is clear of any debris or any sharp protrusions. Product must be attached to the roofing structure using 1" plastic or metal cap nails. Product must be fastened with the nail pattern printed on the product. All anchoring must be performed flush to the roof, 90 degrees to the roof deck that will hold the material tightly with the plywood. The use of every other anchoring location printed on the product is also acceptable. For prolonged exposure, double the overlaps and use every anchor location. Product has 180 Days UV protection but, it should not be considered a final roofing system. A proper final roofing system should be installed over the product to get the proper protection. Product is a secondary barrier used over plywood, under a roofing system like wood and asphalt shingles and metal. Safety otificatialla F-1 Synthetics products are designed with the GRIPSPOT technology for better skid protection for the roofer but product may become slippery due to high moisture, frost, rain, water, dust, debris or other conditions. Use precautions when working on the roof. Follow all local and federal safety codes when installing any roofing system including FT Synthetics products. Failure to adhere to those procedures may result in serious injury or even death. Unit 1.13120 - 76th Avenue Tots Free Ph:1-844.353.9839 ff FT SYNTHETICS Surrey SC V3W 3H8 Phone. 604-594.3589 Fax: 604-594-3589 Canada www.ftsyn.com -7- Single Layer Application of FT HYDRA For slopes greater that 4:12 FT HYDRA should be installed horizontally starting from the bottom of the roof with a 4 inch overlaps working up the roof. 6" (150 mm) Vertical Overlap Eave Drip Edge Under Underlayment Rake Drip Edge Over Underlayment Fasten underlayment as specified in the installation instructions Double Layer Application of FT HYDRA For slopes 2:12 to 4:12 FT HYDRA should be installed horizontally starting from the bottom of the roof with a 4 inch overlaps working up the roof. Eave Drip Edge Under Underlayment Fasten underlayment as specified in the installation instructions Toll Free Ph: 1-844.353-98: unsurreii -��ycv - �.,.�. ,-..`....� Phone:604.594.3439 FT SYNTHETICS BC V3W 3H8 Fax, 604-594-3589 Canada www.ftsyn.com -8-