Product Rating
Certificate of Product Ratinas AHRI Certified Reference Number: 9193892 Date : 04-26-2019 Model Status : Active AHRI Type: RCU-A-CB Series: 14 SEER AC Outdoor Unit Brand Name: CARRIER Outdoor Unit Model Number (Condenser or Single Package) : CA14NA036`0"A` Indoor Unit Model Number (Evaporator and/or Air Handler) : FB4CNF036L Region : Southeast and North (AL, AR, DC, DE, FL, GA, HI, KY, LA, MD, MS, NC, OK, SC, TN, TX, VA, AK, CO, CT, ID, IL, IA, IN, KS, MA, ME, MI, MN, MO, MT, ND, NE, NH, NJ, NY, OH, OR, PA, RI, SD, UT, VT, WA, WV, WI, WY, U.S. Territories) Region Note : Central air conditioners manufactured prior to January 1, 2015 are eligible to be installed in all regions until June 30, 2016. Beginning July 1, 2016 central air conditioners can only be installed in region(s) for which they meet the regional efficiency requirement. The manufacturer of this CARRIER product is responsible for the rating of this system combination. Rated as follows in accordance with the latest edition of ANSI/AHRI 210/240 with Addenda 1 and 2, Performance Rating of Unitary Air -Conditioning & Air -Source Heat Pump Equipment and subject to rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (A2) - Single or High Stage (9517), btuh : 33000 SEER: 14.00 EER (A2) - Single or High Stage (95F) : 12.00 t"Active" Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale; OR new models that are being marketed but are not yet being produced." Production Stopped" Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still selling or offering for sale. Ratings that are accompanied by WAS indicate an involuntary re -rale. The new Published rating is shown along with the previous (i.e. WAS) ratina. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahrldirectory.org, TERMS AND CONDITIONS "IM, This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for Individual, personal and As confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; A..■ �' entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. AIR-CONDITIONING, HEATING, CERTIFICATE VERIFICATION & REFRIGERATION INSTITUTE The information for the model cited on this certificate can be verified at www.ahridIrectory.org, click on `Verify Certificate" link we make life better - and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above, and the Certificate No., which is listed at bottom right. ©2019Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 132007502811673984 Michelle Franklin, CFA -- Saint Lucie County Property Appraiser -- All rights reserved. Property Identification Site Address: Parcel ID: Account #: Map ID: Use Type: Zoning: City/County: Ownership Maria Delgado (LF EST) 401 NE Oleander AVE Port Saint Lucie, FL 34952 Legal Description RIVER PARK -UNIT 2- BLK 17 LOT 13(MAP 34/22N) (OR 3925-271) Current Values 1,544 Just/Market Value: $144,600 Assessed Value: $144,600 Exemptions: $50,000 Taxable Value: $94,600 Property taxes are subject to change upon change of ownership. • Past taxes are not a reliable projection of future taxes. • The sale of a property will prompt the removal of all exemptions, assessment caps, and special classifications. Taxes for this parcel: SLC Tax Collector's Office ❑ Download TRIM for this parcel: Download PDF ❑ 401 OLEANDER AVE 3419-510-0202-000-7 41943 34/22N 0100 RS -4 Saint Lucie County Total Areas Finished/UnderAir (SF): 1,544 Gross Sketched Area (SF): 3,354 Land Size (acres): 0.25 Land Size (SF): 11,000 All information is believed to be correct at this time, but is subject to change and is provided without any warranty. © Copyright 2019 Saint Lucie County Property Appraiser. All rights reserved. AIR CONOITIOIVING I'LLIN1BING b: FLUCTRIG An FPL Entrey SUVICeIII Cnmp.my 582 US Hwy, One, Tequesta, FL 33469 I rn,o n CAC u+ lute. CF CIECt70e0)5) Phone: 561 747.5740 www.j upi ler-tequesta xom PB- 18�1818 7 DATE q-14-11 INVOICE NAME mar, a -4k STREET q01 P� / 01&'14' / )ma _ 1— 1 �,,., r �' f QS CITY cr r; , ,1 G+{I[L[I 4 ZIP % 7 % R PHONE q 19 - B/%- 1303 Vertical Air Handier ❑ New Duct System Condenser on Ground ❑ New AIH Platform I Stand ❑ Package Unit on Ground WNew Concrete Slab ❑ Attic Air Handler G<Emergency Flood Cul OH Switch ❑ Condenser on Roof ❑ New Roof Stand ❑ Package Unit on Roof ❑ New Emergency Drain Pan Remove Existing Equip from Premises ❑ Ne frigeranl Lines" ❑ Crane Service iqui Ine Size Liclion Line Size ❑ Add New Supply Duct VReconnect to Existing ❑ Insulate Suction Line Ductwork I*econnect to Existing Drain Line ❑ Balance Air Flow ❑ New Condensate Pump ❑ New Return Grill 120v 240v ❑ Add New Return Duct jai Refrigerant Line Flush ❑ MANUFACTURER TONNAGE SEER OUTDOOR UNIT INDOOR UNIT HEAT (KW) INITIAL INVESTMENT FPLEs REBATE You PAY TODAY OTHER REBATES TAx CREDIT FINAL INVESTMENT AFTER REBATES WARRANTY Number of Systems in Home Eld Number of Systems Being Replaced Refrigerant Locking Caps (� Hurricane Tie Down Straps Vibration Proof Isolation Pads Reconnect in Existing Ref Lines ❑ Reconnect to Existing Electrical ❑ Filters Standard I Sae ouan:dy ❑ New Duct Work Connect to Existing Cans & Grilles ❑ Air Filtration System ❑ Remove Old AIH Stand ❑ Install Pan & Stand to Code ❑ New Drain Line OPTION A OPTION B OPTION C 3--tbr� 3- Tod _"EAR LABOR Kt's C# y [J' 0_%06- '4_%$6PjUWPr eru 11 t D YEA OUTDOOR COIL _ O LEMON 1� /WEAR _ W UTDOOR COIL ! _ _ NO LEMON o — — — — O- O D YEAR(S) PARTS YEAR LABOR ❑ Surge Protector ❑ Horizontal to Vertical ❑ Time Delay ❑ Hard Start Kit ❑ Line Cover ❑ Mastic Seal All Duct Joint; ❑ NewArH Plenum Return Supply IV Permit Included ❑ New Programmable T Slat XNew Digital Thermostat ❑ New Humidistal ❑ New STD Thermostat Drop Cloths Used OPTION D YEAR(S)PARTS _. _ - YEAR LABOR YEAR COMPRESSOR ----YEAR COMPRESSOR _ -_YEAR INDOOR COIL __YEAR INDOOR COIL ._YEAR OUTDOOR COIL __.YEAR OUTDOOR COIL __.—NO LEMON (VESTMENT OUTDOOR UNIT BEING REPLACED INDOOR UNIT BEING REPLACE i 01 10YEAR(S) PARTS A OYEAR(S) PARTS YEAR LABOR _"EAR LABOR .10 . YEAR COMPRESSOR _� )EAR COMPRESSOR 0YEAR INDOOR COIL— INDOOR COIL 11 t D YEA OUTDOOR COIL _ O LEMON 1� /WEAR _ W UTDOOR COIL ! _ _ NO LEMON YEAR(S) PARTS YEAR LABOR ❑ Surge Protector ❑ Horizontal to Vertical ❑ Time Delay ❑ Hard Start Kit ❑ Line Cover ❑ Mastic Seal All Duct Joint; ❑ NewArH Plenum Return Supply IV Permit Included ❑ New Programmable T Slat XNew Digital Thermostat ❑ New Humidistal ❑ New STD Thermostat Drop Cloths Used OPTION D YEAR(S)PARTS _. _ - YEAR LABOR YEAR COMPRESSOR ----YEAR COMPRESSOR _ -_YEAR INDOOR COIL __YEAR INDOOR COIL ._YEAR OUTDOOR COIL __.YEAR OUTDOOR COIL __.—NO LEMON (VESTMENT OUTDOOR UNIT BEING REPLACED INDOOR UNIT BEING REPLACE i 01 Visa _ MasterCard __ _ Discover _ _ American Express BALANCE BALANCE DUE UPON COMPLETION Acct p i ► i ( i i i I OTOS ' 1 �J a q� S Exp dale. mo. __ _ yr.------- Security Code Ct�et� + �/ ~ CUSTOMER _ _ , ` ACCEPTANCE OF PROPOSAL -THE ABOVE PRICES, SPECIFICATIONS JUPITER-TEOUESTA 1�__ _d4H AND CONDITION ARE SATISFACTORY AND ARE HEREBY ACCEPTED DATE OF ACCEPTANCE - � Wil_ ___- _•—__. YOU ARE AUTHORIZED TO DO THE WORK AS SPECIFIED. PAYMENT INSTALL DATE y' OLIO J 1 ___. ___. WILL BE MADE AS OUTLINED ABOVE. �Q��aN Q MODEL # Iy/_✓P�^/ _ ff SERIAL #J==_ ".! MODEL # '��yJ SERIAL # INVESTMENT LOCATION ��_ LOCATION _. _� DEPOSIT ❑ CASH CHECK ❑ FINANCING ❑ CREDIT CARD INFORMATION (check one) Visa _ MasterCard __ _ Discover _ _ American Express BALANCE BALANCE DUE UPON COMPLETION Acct p i ► i ( i i i I OTOS ' 1 �J a q� S Exp dale. mo. __ _ yr.------- Security Code Ct�et� + �/ ~ CUSTOMER _ _ , ` ACCEPTANCE OF PROPOSAL -THE ABOVE PRICES, SPECIFICATIONS JUPITER-TEOUESTA 1�__ _d4H AND CONDITION ARE SATISFACTORY AND ARE HEREBY ACCEPTED DATE OF ACCEPTANCE - � Wil_ ___- _•—__. YOU ARE AUTHORIZED TO DO THE WORK AS SPECIFIED. PAYMENT INSTALL DATE y' OLIO J 1 ___. ___. WILL BE MADE AS OUTLINED ABOVE. 4/10/2019 Florida Building Code Online • • I I�0>I / . I1 � . 0 � BCIS Home I Log In I User Registration I Hot Topics I Submit surcharge Stats & Facts I Publications I contact Us I SCIS Site Map I Links I Search Florida r r' j Product Approval I 4 USER: Public User Product Approval Menu > Product or Application Search > epylication List > Application Detail FL # FL14239-R4 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer BMP International Inc. Address/Phone/Email 4710 28th Street N St. Petersburg, FL 33714 (727)458-0544 benmeng8@yahoo.com Authorized Signature Xlanbin Meng benmeng8@yahoo,com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Structural Components Subcategory Anchors Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Frank L. Bennardo, P.E. Evaluation Report Florida License PE -0046549 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2019 Validated By Troy Bishop, P.E. •? Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Product Approval Method FL14239 R4 COI Indep pdf Standard ASTM D1761-88 Florida Licensed Professional Engineer or Architect FL14239 R4 Equiv Equiv.pd( Method 1 Option D Year 2000 https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquDEJErtOSCeiRuPjHIQICoFeky9P%2bHVZeDxW83QVcOtQ%3d%3d 1/2 4/10/2019 Florida Building Code Online Date Submitted 08/09/2017 Date Validated 08/16/2017 Date Pending FBC Approval 08/20/2017 Date Approved 10/10/2017 Summary of Products FL # Model, Number or Name Description 14239.1 Slotted Steel Tie -Down Clips, 1" and Steel Tie -Down Clip System (For Use with Mechanical Units at 2" Models Roof or Grade) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL14239 R4 II Dwg,pdf Approved for use outside HVHZ: Yes Verified By: Frank L. Bennardo, P.E. 0046549 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: This design provides allowable capacities for the FL14239 R4 AE Eval.pdf system. The required site-specific design pressure (demand) Created by Independent Third Party: Yes shall be calculated by others for use with this design. nada next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 phone: 850-487-1824 The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Lrivacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your a -mall address released In response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emalis provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public, To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: 01 ® r:Cted Credit Card Safe https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQvADquDEJErtOSCeiRuPjHIQ1CoFeky9P%2bHVZeDxW83QVcOtQ%3d%3d 212 NEW �. R.T■ ENGINEERING E XPRESS� . PRODUCT EVALUATION REPORT ENGINEERING EXPRESS® EXPERT PRODUCT EVALUATION REPORT August 1, 2017 Application Number: FL #14239.1-R4 FLB Project Number: 15-2378 Product Manufacturer: BMP International Manufacturer Address: 4710 28th Street North St. Petersburg, FL 33714 Product Name: Slotted Steel Tie -Down Clips, 1" and 2" Models Product Description: Steel Tie -Down Clip System (For Use with Mechanical Units at Roof or Grade) Scope of Evaluation: This Product Evaluation Report is being issued in accordance with the requirements of the Florida Department of Community Affairs (Florida Building Commission) Rule Chapter 61 G20-3.005, F.A.C., for statewide acceptance per Method 1(d). The product noted above has been tested and/or evaluated as summarized herein to show compliance with the Florida Building Code Sixth Edition (2017) and is, for the purpose intended, at least equivalent to that required by the Code. Re-evaluation of this product shall be required following pertinent Florida Building Code modifications or revisions. Substantiating Data: • PRODUCT EVALUATION DOCUMENTS FLB drawing #15-2378 titled "Mechanical Unit Steel Tie -Down Clip: qt -Grade and Roof -Top Mounted Applications", sheets 1-5, prepared by Engineering Express, signed & sealed by Frank L. Bennardo, P.E. is an integral part of this Evaluation Report. • TEST REPORTS Ultimate test loading structural performance has been tested in accordance with ASTM D1761-88 test standards per test report(s) #TEL 01970387A and #TEL 01970387B by Testing Evaluation Labor-t4[imp Inc. Signed and Sealed by Lyndon F. Schmidt, P.E STRUCTURAL ENGINEERING CALCULATIONS Raised Engineer`��Valu +ihsF ' AO Structural engineering calculations have been prepared which _,P_— _ hr h _2_ O evaluate the product based on comparative and/or rationalnn �EO 0 1 9 analysis to qualify the following design criteria: MUI 1. Minimum Allowable Unit Width = d W 2. Maximum Allowable Unit Height 0 Frank L. Bennar b 3. Minimum Unit Weight # PE0046549 .4. Maximum Allowable Unit Surface Area 5. Clip Configuration and Anchor Spacing 6. Anchor Capacity for Various Substrates 7. Maximum allowable roof -top heights for various installation wind speeds 160 SW ,12TH AVENUE SUITE 106, DEERFIELD BEACH, FLORIDA 33442 PHONE: (954) 354-0660 - FAX: (954) 354-0443 ENGINEERINGEXPRESS.COM V.V'1 ACT6\1 SMl AFI IWmI RllE Nll I S- FSA • MATE RAIN F0 Nil 110MAi-I OfliO GM-? MMVIF I{ Ey&1 111- ENGINEERING EXPRESSO BMP International — Steel Tie Down Clips No 33% increase in allowable stress has been used in the design of this product, Impact Resistance: Not applicable to this product. Wind Load Resistance 8/01/2017 Page 2 of 2 This product has been designed to resist wind loads as indicated in the design schedule(s) on the Product Evaluation Document (i.e. engineering drawing). Installation The product listed above shall be installed in strict compliance with the Product Evaluation Document (i.e. engineering drawing), along with all components noted therein. The product components shall be of the material specified in the Product Evaluation Document (i.e. engineering drawing). Limitations & Conditions of Use: Use of this product shall be in strict accordance with the Product Evaluation Document (i.e. engineering drawing) as noted herein. All supporting host structures shall be designed to resist all superimposed loads and shall be of a material listed in this product's respective anchor schedule. Host structure conditions which are not accounted for in this product's respective anchor schedule shall be designed for on a site-specific basis by a registered professional engineer. All components which are permanently Installed shall be protected against corrosion, contamination, and other such damage at all times. This product has been designed for use within and outside of the High Velocity Hurricane Zone (HVHZ). 60 SW 12TH AVENUE SUITE 106, DEERFIELD BEACH, FLORIDA 33442 PHONE: (954) 354-0660 - FAX: (954) 354-0443 ENGINEERINGEXPRESS.COM V.VYtOJED1ET1111sMIWJolffi TEDOV/N CUPB-Fb1•UPDATE ELIQ1 FOO N11 ELO tiDOO OJE0MM617 TTIO UPL WI l2))16fYALfL-AIDOC