Loading...
HomeMy WebLinkAboutProduct Approval-Window 1/4/2019 Florida Building Code Online t l ®`'V oco '__i.�.'_AF.i)" 16!_i Pr,l._)}>tfei(I.'1I ..0..;!iJi,_,f501 J - t.--- -- � + •I SCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map 1 Links Search b a �,` plii Product Approval pr ._ 'i— ..r. USER:Public User Product ARprovai Menu>Product or Application Search>Application List < Search CriteriaRefine Search Code Version 2017 FL* Im- 16851.6 Application Type ALL Product Manufacturer ALL Category ALL Subcategory ALL Application Status ALL Compliance Method ALL Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL Product Model,Number or Name ALL Product Description - ALL Approved for use in HVHZ ALL Approved for use outside HVHZ ALL Impact Resistant ALL Design Pressure ALL Other ALL Search Results-Ap•licatlons FL# Type Manufacturer Validated By, Status FL16851- Revision NewSouth Window Solutions Ryan J. King, Approved BZ FL#:FL16851.6 P.E. History. Model:f.9450 Single Hung Window Impact Rated-HVHZ (813)767- Description:Extruded Vinyl"Impact"Single Hung Tilt Window with Flange 6555 (O/X-configuration) Category:Windows Subcategory:Single Hung 'Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Contact Us::2601 Blair Slone Road,Tallahassee FL 32399 phone:850-487-1824 The State of Florida is an AA/EEO employer.CoovligJtt 2007-2013 State of Florida,::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click hug_. Product Approval Accepts: ® Credit Card Safe securitvMPTFtIcs• https:/lwww.floridabuilding.org/pr/pr_app_Ist.aspx 1/1 1/4/2019 Florida Building Code Online I :1 _✓ 'krkF: :t, yr: p l ' : 4` .�F �' '� r•J .�:'~` ; { . :(IF )� It �l tti Ii t�' j ia7.pt) . BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map ' Links Search Honda T E Product Approval 'tom s USER:Public User Product APnroval Menu>Product or Application Search>Bpphcation List>Application Detail I . I;.. ra=.,45:;;a FL# FL16851-R7 Application Type Revision Code Version 2017 Application Status Approved Comments Archived • Product Manufacturer NewSouth Window Solutions Address/Phone/Email 4901 oak fair blvd tampa,FL 33610 (513)284-0129 danochstein@newsouthwindow.com Authorized Signature Vivian Wright rickw@rwbIdgconsultants.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Single Hung Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Lyndon F.Schmidt Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2019 Validated By Ryan 3.King,P.E. Validation Checklist-Hardcopy Received Certificate of Independence FL16851 R7 COl (d)Certificate of independence.pdf Referenced Standard and Year(of Standard) Standard hear AAMA/WDMA/CSA101/I.S,2/A440 2011 AAMA/WDMA/CSA101/I.S.2/A440 2008 ASTM E1886 2005 ASTM E1996 2006 ASTM E1996 2009 TAS 201,202,203 1994 Equivalence of Product Standards Certified By ' Sections from the Code https://www.floridabuiiding.org/pr/pr_app_dthaspx?param=wGEVXQwtDgtmmTSTNdVPsacfoLiCDIJOysrHoxOGe9cEYNv7g2Qi0Q%3d%3d 1/5 • 1/4/2019 Florida Building Code Online Product Approval Method Method 1 Option D Date Submitted 06/07/2018 Date Validated 06/26/2018 Date Pending FBC Approval 06/27/2018 Date Approved 08/15/2018 Summary of Products Go to PageEdi' 0 0 Page 1/2 0 0 FL# IModel,Number or Name Description 16851.1 a.9400 Single Hung Window Extruded Vinyl"Non-Impact"Single Hung Tilt Window New Construction with Nail Fin(0/X-configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 R7 II ((I)Inst 16851.1.0f Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.1 for Design Pressure Ratings,any FL16851 R7 AE (b)Eval 16651.1.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16851.2 b.9400 Single Hung Window Extruded Vinyl"Non-Impact"Single Hung Tilt Window with Flange(O/X-configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 R7 II (b)Inst 16851.2‘0.f Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.2 for Design Pressure Ratings,any FL16851 R7 AE (b)Eval 16851.2.01 additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16851.3 c.9450 Single Hung Window Extruded Vinyl"Impact"Single Hung Tilt Window New Construction with Nail Fin(O/X-configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 R7 11 (b) Inst 16851.3,pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 16851.3 for Design Pressure Ratings,any FL16851 R7 AE (b)Eval 16851.3,pdf additional use limitations,installation Instructions and product Created by Independent Third Party:Yes particulars. J 16851.4 d.9450 Single Hung Window Extruded Vinyl"Impact"Single Hung Tilt Window with Flange (O/X-configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 R7 II (b)Inst 16851.4.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 16851.4 for Design Pressure Ratings,any FL16851 R7 AE (b) Eval 16851.4.p�1f additional use limitations,installation Instructions and product Created by Independent Third Party:Yes particulars. 16851.5 e.9450 Single Hung Window Impact Extruded Vinyl"Impact"Single Hung Tilt Window New I Rated-HVHZ Construction with Nail Fin(O/X-configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16851 R7 II Oa)Inst 16851.5,0f Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.5 for Design Pressure Ratings,any FL16851 R7 AE ()2)Eva! 16851.5,pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. _ � I 16851.6 !f.9450 Single Hung Window Impact Extruded Vinyl"Impact"Single Hung Tilt Window with Flange Rated-HVHZ (O/X-configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16851 R7 II (b) Inst 16851.6 pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 haps;//www.floridabuilding.org/pr/pr_app_dtl.aspx7peram=wGEVXQwtDgtmmTSTNdVPsacfoLiCDIJOysrHoxOG89cEYNv7g2Qi0Q%3d%3d 2/5 1/4/2019 Florida Building Code Online Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.6 for Design Pressure Ratings,any FL16851 R7 AE (b)Eval 16851,6,pdf additional use'limitations,installation instructions and product I Created by Independent Third Party:Yes particulars. 16851.7 g.4400 Single Hung Window Extruded Vinyl"Non-Impact"Single Hung Window New Construction with Nail Fin(O/X-configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 R7 II (¢) Inst 16851.7.gdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Imp act Resistant: No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 16851.7 for Design Pressure Ratings,any FL16851 R7 AE (b)Eval 16851.7,pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16851.8 h.4400 Single Hung Window Extruded Vinyl"Non-Impact"Single Hung Window with Flange (O/X-configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 R7 II (g)Inst 16851.8.0i Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.8 for Design Pressure Ratings,any FL16851 R7 AE (d)Eval 16851.8.p�tf additional use limitations, installation instructions and product Created by Independent Third Party:Yes particulars. 16851.9 i.4450 Single Hung Window Extruded Vinyl"Impact"Single Hung Window New Construction with Nail Fin(O/X-configuration) Limits of Use Installation Instructions Approved for use In HVHZ:No FL16851 R7 iI (d)Inst 16851.9,01 Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.9 for Design Pressure Ratings,any FL16851 R7 AE (I)Eval 16851.9.pd additional use limitations,installation Instructions and product Created by Independent Third Party:Yes particulars. 16851.10 j.4450 Single Hung Window 1 Extruded Vinyl"Impact"Single Hung Window with Flange O/X 1-configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 R7 II (c)Inst 16851.10.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.10 for Design Pressure Ratings,any I FL16851 R7 AE (d)Eval 16851.10,pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. — --------- ------------------._..-----------1--------------._.—_.-- --'—--------------^----_--- 16851.11 k.4450 Single Hung Window Impact Extruded Vinyl"Impact"Single Hung Window New Construction Rated-HVHZ with Nail Fin(O/X-configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16851 R7 II (12)Inst 16851.11.p�i f Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes • Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other;See INST 16851.11 for Design Pressure Ratings,any FL16851 R7 AE (k) Eva! 16851.11,W additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16851.12 I.4450 Single Hung Window Impact Extruded Vinyl"Impact"Single Flung Window with Flange(0/X Rated-HVHZ -configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16851 R7 Ii (12)Inst 16851,12.W Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.12 for Design Pressure Ratings,any FL16851 R7 AE (12) Eval 16851,12.0j additional use limitations, installation instructions and product Created by Independent Third Party:Yes particulars. 16851.13 m.4000 Twin Single Hung Window Extruded Vinyl"Non-Impact"Twin Integral Mulled Com mon Jamb Single Hung Window New Construction with Nail Fin(O/X I 0/X-configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 R7 iI (b) Inst 16851,13,01 https://www.floridabuilding.org/pr/pr_app_dti.aspx7param=wGEVXQwtDgtmmTSTNdVPsacfoLiCDIJOysrHoxOGe9cEYNv7g2Qi0Q%3d%3d 3/5 1/4/2019 Florida Building Code Online Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.13 for Design Pressure Ratings,any FL16851 R7 AE (b)Eval 16851.13.pdf additional use limitations,installation Instructions and product Created by Independent Third Party:Yes particulars. 16851.14 n.4000!Win Single Hung Window Extruded Vinyl"Non-Impact"Twin Integral Mulled Common Jamb Single Hung Window with Flange(O/X 10/X- configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 R7 II (b) Inst 16851.14,1cl Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.14 for Design Pressure Ratings,any FL16851 R7 AE (b)Eval 16851.14 pdF additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16851.15 o.4000 Triple Single Hung Window Extruded Vinyl"Non-Impact"Triple Integral Mulled Common Jamb Single Hung Window New Construction with Nail Fin(O/X I O/X I O/X-configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 R7 II (b)Inst 16851,15,psi_f Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.15 for Design Pressure Ratings,any FL16851 R7 AE (b)Eval 16851,15.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars, 16851.16 p.4600 Twin Mulled Single Hung/ Extruded Vinyl"Non-Impact"Twin Integral Mulled Common Picture Window Jamb Single Hung/Picture Window New Construction with Nail Fin(0/X I 0-configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16851 R7 II (b) Inst 16851.16.0i Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.16 for Design Pressure Ratings,any FL16851 R7 AE (b)Eval 16851,16,01 additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16851.17 q.4600 Twin Mulled Single Hung/ Extruded Vinyl"Non-Impact' Twin Integral Mulled Common Picture Window Jamb Single Hung/Picture Window with Flange(O/X I O- configuration) Limits of Use Installation Instructions Approved for use In HVHZ:No FL16851 R7 II (b)Inst 16851.17‘pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.17 for Design Pressure Ratings,any FL16851 R7 AE (b) Eval 16851.17,pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16851.18 r.4800 SH/SH/SH-Triple Single Extruded Vinyl Integrally Mulled Triple Single Hung Windows Hung with Flange; (0/X I O/X I 0/X configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 R7 II (b)Inst 16851.18,11 Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 16851.18 for Design Pressure Ratings,any FL16851 R7 AE (b) Eval 16851.18,pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16851.19 s.4900 SH/SH-Twin Single Hung i Extruded Vinyl Integrally Mulled Twin Single Hung Windows with Flange; (O/X I 0/X configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 R7 II (S1)Inst 16851.19.0f Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 16851.19 for Design Pressure Ratings,any FL16851 R7 AE (g)Eval 16851,19,pdf additional use limitations, Installation instructions and product Created by Independent Third Party:Yes particulars. 16851.20 t.4900 SH/SH/SH-Triple Single 1 Extruded Vinyl Integrally Mulled Triple Single Hung Windows httpsJ/www.floridabuiiding.org/pr/pr_app_dtl.aspxlparam=wGEVXQwIDgtmmTSTNdVPsacfoLiCDIJOysrHoxOGe9cEYNv7g2Qi0Q%sd%3d 4/5 Florida Building• g Code Online Hung with Flange; (O/X I O/X I O/X configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 R7 II (d)Inst 16851.20,pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.20 for Design Pressure Ratings,any FL16851 R7 AE (d)Eval 16851,20.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes • particulars. I Go to Page 0 0 Page 1/20 0 Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EE0 employer.cggytight 2007-2013 State of Florida;::Privacy Statement::Accessibl14y Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ecte:l .513 Credit Card Safe Securi.tylf tTRIcs' • • https://www.floridabuilding.org/pr/pr app_dtLaspx7param=wGEVXQwtDgtmmTSTNdVPsacfoLiCDIJOysrHoxOGe9cEYNv7g2Qi0Q%3d%3d 5/5 At E INewSouth SS MAX OVERALL FLANGE WIDTH _ / f �EZ'1 �` I z=- SSMAX.OVERALLFRAMEWIDTH 7.OS. iIWINDOWSOWTIONS V'�., ... on j ''��lrlll llltlVt,`` 0 N o Z 4901 OakeFal�BBlvd.,Tampa.FL 33610 //// V 1 0 i 22k1- / a a / S p LLe e 9450 Single Hung Window 5 0 I a Ah IMPACT RATED - HVHZ = g /1 zo m 3 WZ §. w/Flange 2 w ' $ z4 m I (] G W F m O // w o 3 d, 5 GENERAL NOTES A / z o EU! 1. This product has been evaluated and is in compliance with the 6th Edition L. g (2017)Florida Building Code(FBC),including the-High Velocity Hurricane / a L o Zone"(HVHZ). /// -,E E m a2. Product anchors steal be as fisted and spaced as shown on details.Anchor / m z _,, embedment to base material shall be beyond walldressing or stucco. E 3. When used in the"HVHZ".this product complies with Section 1626 of the Florida N n§ rn Building Code and does not require 3'0� an impact resistant covering. to= a 0 o S 6p i n h. 4. For 2x stud framing construction,anchoring of these units shall be the some as ✓o a o h E t: that shown for 2x buck masonry construction. thisire further o z o 8 5. Site conditions that deviate from the details of drawing requ �o~oooU g engineering analysis by a licensed engineer or registered architect. 'Q Q - z ^(s(ohn F 5, w T D.-N-0.< ..i MAX OVERALL MAX.OVERALLMAX MAX DESIGN PRESSURE 9.,ane g 3 TABLE OF CONTENTS DAY IRE DAY UTE GiLA�S = i SHEET# DESCRIPTION RANGE FRAME DIMENSION LNMENS10N v W mane—� u 1 Typical elevations,design pressures&general notes DIMENSION DIMENSION (OPERABLE) (FIXED) POS. NEG. wro 2/19/14 =- g 2 Vertical&horizontal cross sections 55.0"X 77.0" 54.0-X 76.r 4725'x 34.38' 4935'x 34.5 GI,G2 +55.0 -65.0 SCAM N.T.S.Jm 5' 3 Vertical&horizontal cross sections A 4 Buck&frame anchoring 35.0-X 63.0' 37.0"X 62.0' 3025 x 27.38 3236 x 27.5' G1.G2 +65.0 -85.0 0"ef` LFS 5 Components °P"'91010 v 6 BITI of materials and glaring details Note:This product,when used with GI glaring,is not approved for use above 30 feet In the'HVHZ'. FL-16851.6 H 1 ti steal 1 or 6 0 • d � •aH1 wn+immaa 84411imin'1A71 r tab O ' SN 0146 '0N VO 3d43 OISf�38 1616'6Ti9Sle=aN�Yd SN{RIO3S SSOMO ,tg 3��LLYQQ `0N , �o e cam Zi 'awn'OCL xe4 'O'd�• J 1Y1N0ZRlOH '1t9112l3A an OW (hard '03/LLC 01 31YOd0 Zt(9Z(9 t ui x 'ONI 'SJM11VlSHHO3 ONI0UC �j :KIBN3SSV 6O 1MYd )iP 'UYl3d JNIIYb 00Y C&JJ[L t//Zt L Obi �'• s pt 'd ` -•:: UIIIII///* Sil SOK* 'ON 7'd sf1 3215 MOWN Z4x1C awe*Lt(f via f N z a i 44/Flo , 'f. ,�i.� iPFWv4 Y ucD Ii M00NMM ON(7H 379NIS w ai Wag) '03 H19 01 31Y0dn LIJJQOJOI c 3 g 0 g IC i ��: b 'S �s�PAY6L�AOO71d S« r i w LIOi LI Jsg0120 i 4eastreN f 4- tad ilve .t/t-i ' 101.11L-1i '0 ©0 - R ' 0 • o e0O 00 q • r-1. a i— "�ioi ,. • _ii: ,I �E" ' � � �II' �ii tor •� � fil a :111111 ie 00 0 MI WA iiraTi 7 •. v. u -11111.111.241- 0 o p © a a0 0 © 4 • E 0 111 ga � h n 41-1:115-r, �c 1�ts1��.J' a I� III i i 0 0 11-121 1....� CO s,-=.r,_f�L-, 0 I lint rn) 11 I III © 1111 0F-.11j1 11I O �N O 1 QQ emikD • ,1,Ldill 1!1 ; O x p `I' �1 �--� ©vu _. ir VI F. eall WM ; —-` l' ata i- egt-i Ltt)Ka9L-1 u-maxiii+ U5sss9 YO V Dawe•PsnB-wNINWORO goocoVA OPoos wNw v 'OmI■JINY17nINQa UNI?Ima'ma T{ac Q SIM'aH YD 3d83 sNOIl�3S SSW I L0166Iw 99•[19 PcN cVd WINOIIHON V 11411113AAH- 3JY0 'ON m col 9119CC Zi•°°HIM•CCL coil •C•d�� yr! �{i10Z) '03 H1 of 31Kldn c /� 1 c/1 "I •0141 •81HY11nSNoo oNI011I� 9 fA'191GSSY!10 131Yd r 'IIY130 mama OOY Sl L1/ZI Z Cf I-• b \%%%%%%%%%%% ,L sil Nan=NCHCHY LW Qaticw'91 LLLLfJ0 [ ` ' d... I.1 \\ L�I� eo,, 'oM •9' S.it 3215 MOONGI Z9�LC 0300W LL [(� i Cf �1 I � f. , WA a u pI LI bt00Niv 0NlIH 31MS xr. !Clot:) •0 H19 Ol 31YOd11 L1/Qoloi s h i i ' ^ Lt0Et1�99ax1D {i Aa1C/by ▪ 'YiaiannH%%%%% NM live NU ire I •NIW Jil-t 'N WE-I 0 O 0 $ Oe © o . . . o 14e o 0 • ,, e e .. r.:Izirsill l I �r.-�" r � ;it. Cl?. : jI: 11— [ e p 1 • o O g % Q ••� • _ 1_77.41' Z © •e e . ° II�I ° • • 111 0 - � pR - ill � CJjiioojiIt4 o© 31 li a IIS iii 0llijI - Emig l ate► 0 0 PE0111 u-§1 0= al 5 X12 111 0 o a 0 , ...-.. I. •••••:....... 11 ILIA., Q. e v! - 1 out8 [-.:;_4_,_: Limpi r,r1-.1i CS o x d© o Ili ,�i rijk- mer -. i1 -. • g ;� 4D 4PCIP 11 i 13 g r " • P • . O ps�I Z CI tmansan vULud Ts99c-106A cc+C•30044*s Ss39L TONaiddY=Mid oplbu-vutain iaa wpm Limos.apAma 3% 01 ii it iti z:.. ("-- . s. A j_ 1 14, r – eP 3Ea.SPACE II'hAAX OC. S' r ` 1 E,..., f pi .� s 112 mea 1 �'�.�~` '` �`'`` ~ .I p ,,---1 la I 11 1111 ::.;a4; T , Ill 1 i i igg .. In E. QO2XRUCK �tSASH tri 0 2X SUB O 1X8UCK i BUCK [R#ME I1 0 STEM STUD I 3 n ___L_i 3{ IYP. 1 c Y is V — _ 2X SUB � z SNR, CO BUCK j �syy tt g OPENING , TM. ..1- MASONRY j 1nE. i3 v .y SASH t>PEtiNf' I__---f SASH r y Ig le Q . Rn g R CONCRETE ANCHOR a , 1.Concrete anchorbcotbra at the comers may be oQeted to mainta n the min. ,d1: o a/otntR =•4 3 , g 2.Canasta andnobcattoss notedor'MAX ON CB4781"mat be alluded to Fr n e r.../) mahMh the nntn,edge dIstance to moda/ai1tA addlpoed concrete anchors •may be-requited to erose Rse'MAX.ON CadErdiman6on ass notexoesded. 8, �Sv 6^�N g 1 a Concrete anchor table �p�"�`0 , . ''' :. ' ^.;:Mw;°taEARANEE, M1PIq'.l1SM.4HCE. n+n a- z °u ..erLCN(kR:::•ANCIIdR •,i.•••'• ' , _ . R,•• ..:7Q`i ri!C M''. a •_73'?8•:••: ';SITE'•:\Efil IK iIENr,/,:-"••_ FbCE•�•_... `.:• AkieHO ..;- ea[ 2/19/14 �c i 1AMONe 1/4' 1.1/c 1 c sad Ky.& °_ n JK • O.e RCO1UgRACONe 1/4 1.114' 1' 4 ce in*cm a 13 f WOOD SCREW INSTAUATK)N NO1E$ a t.Mat**a minimum 1N8'edge e9starsae,rend distance,a 1'o.c.spacing of FL-16851.6 6 - a wood saesa to prevent the spitting of wood snna* ar$ p a\Q.mrwwSouth Wmeao.PUW1ANFNiU-Florida Product Ayfprord011-15S31Singla Hung1C-oraw+rwrifL-ue310:01 PR.•uc5L.M 34 229" - 1 n 4 FL, , ,cc,.. , ,-,i, 0.062'-- ,-.- el 17 onL o It 1 I 0- fili11 Q" ,,,_,, lj II 27 9' D 21 r_1.24"—.. - ..K.Cr'-'''''..aq ra e tE* 1i' o 4 if ifl I� 1.61" 1--124'----Iq fes--------1.7r I 1.66' 124' F4 O I 211—UliQ 1-. r U I 4 ` , 1.42" Jy ' ib 7 �f �0.21' ei11 o _ QI �l 1A2 217 1 I L, I 4 #I y —ra `,`,,�p111atufq,�I''. ygliiiiM _ Pin 43409 t T 1 October 12,2017 rj. % F%,E. PRODUCT: ti.Pa.4 aHi W J '% 1 5 10 08 17 UPDATE TO 6TH ED.{�17)MC JK SINGLE HUNG mom on P. SchmIa ...'� I IR \ 3 /17 17 ADDED 37762 WINDOW� SIZE'MATLFS RPS L No. 43400 '♦�/�ffff1111R1\���`,` L_ ` y 2 192,7 I S ING DETM. JK' PAWT QA A,wp19LY: BUILDQf0 IR7MR7. INC. y .. 1 6 14 UPDATE TO SDI W. (2014)FRC RPS P.O. Box 230.YOMoo. FL 33693 of a. NO. Fry, COAIPONEMSPhone Now 613.669.9197 r REVISIONS _ Fere CA. No.9613 62Q1 a A.W.9u,wn.o QOH.w.Tun.Mo. _-- ---- IILLOfAIAJERIAIS `�`�` *• 44i� RAI III 0 11011 MAMMAL ,4,..e. Is. a B 2X BUCK(SG>=0.55) WOOD f .� C 1!4 MAX.SHIM SPACE - : D 1/4X2-3/4 PFHELCOORfWCONCRETE SCREW STEEL e E g* ' MASONRY-3.000 PSI MIN.CONCRETE CONFORMING TO ACI o E _ 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE 'moi .,,•«. `�% I B o F _ max r PPH SMS 11-114"MRN.EMBEDMENT) Sm. ,rrrirtil 1Af•*�`` ��;� G 2XSTUD(SG>=055( WOOD w I 3 H #10X2-1/TPPHSMS STM. Sir L STEEL STUD Min.Thk.033'{ASTM A653 GRADE 33 331x1 min.,Fir-45161 mb.) STS DK BBE 7/8'0A.GLASS \ 3 K MIO PPH SELF-DRILLING SMS STEEL GMADNG SEALANT vv vial a l i L *10 X 2'PPH SMS(1-i/2"MIN.EMBEDMENT) Sm. ( -552I4 1 EXTRUDED VINYL FRA6e(465)' RIGID PVC a 5,1 2 EXTRUDED VINYL GLAZING BEAD(736A` RIGID PVCr=r�-=4 1/B'AWrF/LL!D GLASS d 3 EXTRUDED VINYL GLAZING BEAD(425A• RIGID PVC 0.090'SARDP PVB PO ILAYEt a 4 581 (469)' RIGID PVC �� 5 STILE(438)• RIGID PVC 118'ANPEAIEDGLASS 6 METING RAIL 477)' RKY PVC -111AR SPACE 7 LOCK RAIL(476)• RIGID PVCrom_\ UB ANNFALIDG1A55 8 BOTTOM RAIL(4858)' RIGID PVC 1 > >F g 9 MEETING RAIL RINFORCEMENT 6063-15 ALUM METALREINFORCED BUTYL x r. 10 LOCK RAIL REINFORCEMENT 6063-13 ALUM 11 KLOCK - Not approved for use above 30 feet In the IIVHt. G 12 �KEEPER II 1 13 BOTTOM RAIL RENFORCEMBIT 6063-15 MUM Gl Gum 13EYA 14 HEAD ADAPTER(473)' RIGID PVC 18 SUE REINFORCEMENT 6063-T5ALUM 4 Ny 21 E 20 WEATHERSTRIP - 21 BALANCE468) RIGID PVC 22 EXTR DB)U CVINYL GWING BEAD WI DRIP EDGE(467)' RIGID PVC I7/8'0.A.Guss INK. W 24 BULB GASKET(AMESBURY) FOAM GLAZINGSEALANt R'a R 3 *THE APPROVED WHITE RIGID PVC EXTERIOR EXTRUSIONS FOR WNDOWS ARE TO BE PRODUCED BY is/Irma-552) vx DRRUDERS UCEHSEES IN'MMA CERTIFICATION PROGRAMS FOR RIGID PVC EXTRUSIONS'. 8$g�F4„B aI _ 118'ANNEALED GLASS 3 LJL? LI-7,==7. 01190'SAHFX.N1 NIE tlAYER 4 2 `�B K ni4 Ia $ 1/$'ANNFiNID GLASSI AR SPACE7E-1 \ ^hun+n • t!8 Tf GLASS AAETALR6NFORG®11111YL o Wh nM nC-. p Or i CAT 2/17/14 S SMe N.T.S. wo.re: JK' e' INOTE GLAZING>36"WIDE REQUIRES TWO(2)SETTING oat an EFS . BLOCKS CONFORMR4GTOFBCSEC11ON2411.3.3.1 011°116 MD' FL-16857.6 u - sat s22..Or B p Til L