HomeMy WebLinkAboutProduct info PARADHE ,`-, . 7 TER- 00R # "Buildings Our Qy0fit ReutP't!-."o n: One Customer At A Time SCC131150472 Property Information Building Information Owner: TIMOTHY THAYER Wind Zone: 170 MPH. Address: 7008 LAKELAND BLVD Exposure Category: C FORT PIERCE,FL 34951 Minimum Building Dimension: 37 ft. Mean Roof Height: 12 ft. Risk Category: II Design Pressure Calculations JOpening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) 11 Pressure(psf) 1 Int 71 80 7 34.4 -37.6 2 End 71 80 7 34.4 -43.9 RECEIVED APR 3 0 2019 L ucie County, permitting FILE Uo"OP Prepared in accordance with:ASCE 7-10,Chapter 30.Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page 1 of 1 - A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET Definition of Comer Zone-10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft. OPENING (Location) IS THIS A PRODUCT PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE ARE GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW LOCATION Corner Zone WINDOW ACCEPTANCE OPENING SHUTTERS NUMBER or Interior OR DOOR TYPE NUMBER + PSF + PSF TESTED MULLION ( ) (-)PSF ( ) (-)PSF SIZE DIMENSIONS REQ Y/N/NA REQ YIN 1 Int Door I"LamiIG FL11103.1 60 60 34.4 -37.6 96x96 71x80 No No 2 End Door V Lami IG FL 11103.1 60 60 34.4 -43.9 96 x 96 71x80 No No m � L U-1 o a N W =) 2 M Lu- 7 v ^00 OL U 7 .7 1�rt