HomeMy WebLinkAboutWind Load Calculation cA" i RECEIVED
"BurldiriA Jur'-DISE -EXTE OR
Quality Rhe� utron APR 3 0 2019
QnUS ��1'1G 1w/"1 I " ST. Lucie County, Permitting
SCC131150472
Property Information Building Information
Owner: CRAIG&LORETTA RAMSEY Wind Zone: 170 MPH.
Address: 8290 RED CEDAR PL Exposure Category: C
PORT ST LUCIE,FL 34952 Minimum Building Dimension: 45 ft.
Mean Roof Height: 12 ft.
Risk Category: 11
Design Pressure Calculations
1[ Opening Location Device Device IFDevice Max Positive EMax Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psi)
1 Int 35 24 7 37.8 -41.0
2 End 26 61 7 37.6 -50.1
3 End 25 61 7 37.7 -50.3
4 Int 25 61 7 37.7 -40.9
E5 End 25 61 7 37.7 -50.3
6 Int 35 23 7 37.8 -41.0
DV
FILE UUN I
Prepared in accordance with:ASCE 7-10,Chapter 30.Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code.
Page 1 of 1
OPEN
A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET
Definition of Corner Zone-10°/6 of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft.
PRODUCT APPROVAL REQUIRED OPENING MAXIMU MULTIPLE
OPENING (Location) IS THIS A PRODUCT ROUGH ARE
GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M
LOCATION Corner Zone WINDOW WINDOW TYPE NUMBER
TESTED OPENING MULLION SHUTTERS
NUMBER or Interior OR DOOR NUMBER (+)PSF (-)PSF (+)PSF (-)PSF DIMENSIONS REQ Y/N
SIZE
REQ YIN/NA
1 Int Window 7/8"Lami FL16177.1 70 70 37.8 -41.0 52x62 35x24 No No
2 End Window 7/8"Lami FL16177.1 70 70 37.6 -50.1 52x62 26x61 No No
3 End Window 7/8"Lami FL16177.1 70 70 37..7 -50.3 52x62 25x61 No No
4 Int Window 7/8"Lami FL16177.1 70 70 37.7 -40.9 52x62 25x61 No No
5 End Window 7/8"Lami FL5823.1 67.5 67.5 37.7 -50.3 53x76 25x61 No No
6 Int Window 7/8"Lami FL16177.1 70 70 3'7.8 -41.0 52x62 35x23 No No