Loading...
HomeMy WebLinkAboutWind Load Calculation cA" i RECEIVED "BurldiriA Jur'-DISE -EXTE OR Quality Rhe� utron APR 3 0 2019 QnUS ��1'1G 1w/"1 I " ST. Lucie County, Permitting SCC131150472 Property Information Building Information Owner: CRAIG&LORETTA RAMSEY Wind Zone: 170 MPH. Address: 8290 RED CEDAR PL Exposure Category: C PORT ST LUCIE,FL 34952 Minimum Building Dimension: 45 ft. Mean Roof Height: 12 ft. Risk Category: 11 Design Pressure Calculations 1[ Opening Location Device Device IFDevice Max Positive EMax Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psi) 1 Int 35 24 7 37.8 -41.0 2 End 26 61 7 37.6 -50.1 3 End 25 61 7 37.7 -50.3 4 Int 25 61 7 37.7 -40.9 E5 End 25 61 7 37.7 -50.3 6 Int 35 23 7 37.8 -41.0 DV FILE UUN I Prepared in accordance with:ASCE 7-10,Chapter 30.Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page 1 of 1 OPEN A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET Definition of Corner Zone-10°/6 of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft. PRODUCT APPROVAL REQUIRED OPENING MAXIMU MULTIPLE OPENING (Location) IS THIS A PRODUCT ROUGH ARE GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M LOCATION Corner Zone WINDOW WINDOW TYPE NUMBER TESTED OPENING MULLION SHUTTERS NUMBER or Interior OR DOOR NUMBER (+)PSF (-)PSF (+)PSF (-)PSF DIMENSIONS REQ Y/N SIZE REQ YIN/NA 1 Int Window 7/8"Lami FL16177.1 70 70 37.8 -41.0 52x62 35x24 No No 2 End Window 7/8"Lami FL16177.1 70 70 37.6 -50.1 52x62 26x61 No No 3 End Window 7/8"Lami FL16177.1 70 70 37..7 -50.3 52x62 25x61 No No 4 Int Window 7/8"Lami FL16177.1 70 70 37.7 -40.9 52x62 25x61 No No 5 End Window 7/8"Lami FL5823.1 67.5 67.5 37.7 -50.3 53x76 25x61 No No 6 Int Window 7/8"Lami FL16177.1 70 70 3'7.8 -41.0 52x62 35x23 No No