HomeMy WebLinkAboutProduct Approval-ShinglesA13012019 Florida Building Code Online
TA MwProfessional + t
M 990=
9¢S Home I Log In i User Regi&ntlor I Hot Topics I Submit Surcharge [ Stats & Fids I publications I Contact Us I ®cls Site Map ' Links Seardt f
rR I` da
pr Product Approval
uaele: Publicuser
product Aooruy34 Menu > Product
or Anollcatkg_n Search > AonllCation list > Application 6dall
FL #
FL10124-R21
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
Archived
Product Manufacturer GAF
Address/Phone/Emall 1 Campus Drive
Parlsppany, NJ 07054
(800)766-3411
mstleh@9af.com
Authorized Signature Robert Nleminen
Irelth@)nemoetc,com
Technical Representative William Broussard
Address/Phone/Errlall 1 Campus Drive
Parsippany, N] 07054
(800) 766-3411
TechnlcalQuastlonsGAFOgaf, com
Quality Assurance Representative
Address/Phone/Emall
Category Rooling
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE -59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration oats 10/18/2021
Validated By John W. I(nezevich, PE
* Validation Checklist - Hardcopy Received
Certlflcate of independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
>m
ASTM D1970
ASTM 03161
ASTM 03462
ASTM 07158
TAS '107
YM
2015
2016
2010
2011
1995
helps,lAVWW.kvMalbuildit,wgip* app till,ispOpwwn=WGrEVlCLlWINUMCBeVCbdMONZDSZesy3BoOyLw7Q3111dCnnNOYyYYCg7Q%3d%3d 1/2
Q301201 9
Florida Building Cade Online
Sections from the Cade
Product Approval Method Method I Option D
Date Submitted
02/19)2019
Date VaWated
02/19/2019
Date Pending FBC Approval
03102/2019
Date Approved
04/16/2DIg
Date Revised
mum
FL 9 Model, Number or Name
Description
10124.1 GAP Asphalt Roof Shingles
Flberglass reinforced 3 -tab, laminated, 5 -tab and hip/rt
asphalt shingles
Umits of Use
Installation Instrwi tiom
Approved for use In HVHZ: NO
E"0124 ft2lJ13019 02 FIN& ES GAE ASPHALT
ro
Appved for use outside NVHZt Yes
SHINQLEE EL10�- 321.nd
Impact ilsalstarib NfA
Verified By: Robert Nlemincn PE -59166
Design pressures NIA
Created by Independent Third Party: Yes
Other: Wer to ER, Section S.
Evaluation Reports
fLI0121 S-21 61 2Q12 Q? FltjAl
SHIN ES FL10124-R21_odf
Created by Independent Third Party: Yrs
ay:.4 lrf�l
{ SfeN Stena ate. llraaheie.r rE lY39a Lnunr W Ia7-tats
The Stale at f iw 4b lean AlUCYti ampioyw. :: : e e WaLaulmd
Una* flume ism, .meu earr.rw A,e PuW c rv4e. if you ee nae toad TOW &. srt.es+W F@hW=e m NDPea. to s aW66CwnUw* r*orgt, ift na go SW a, tc
rruli 10 tlas enmtY. Inl+iad, Cart6dr Uwe alrlra by Die Vr 6Y rna+pv�ui mall. Ir eau Ww ani' aNaaa, Mweaa sR4Q VWAOMM S.'hwa+W b SEAM 4'14.17!{11..
Pxmwa StmL as. effe&ve 0doW f, 3011, kcwwsse Yunaed wWW Meow 418, ML mut P ok tlla Dom op aM wM ae arnaY +terur V el.r flora arm Yue amyls
fsaMdad may ba used tar a/fl0el m++mrun�en +riSR {ha Gtana.e. t8aeaw email aae,ews era saaMc raC4A, A Tau ad nal edlh;p eupsllr • i�Mf apare� P=ea
pmlds the Ow Mnant W N in omffil aadrpe `edcu caa ba made avWkWe in an p WW. To downNnr a Vw aro s lisws wdw chww qts, tl_S., rice 46 mat,
#-awl Aa*rraN a+aaal AS
ZWORE
Cred i Cad
safe
hi4mlANww.flWdabLWding.wglWtp_ eLppdnAapx?Pwwn=wGEVxQwt0curacO• moyAwXKMdCN*CYyYYC47ox36%3d 212
NEMO|etc.
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203) 262-9245
ENGINEER EVALUATE TEST CONSULT CERTIFY
EVALUATION REPORT
GAF
1 Campus Drive
Parsippany, NJ 07054
(800) 766-3411
Evaluation Report 01506.01.08-R23
FL10124-R21
Date of Issuance: 01/03/2008
Revision 23: 02/18/2019
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted
herein.
DESCRIPTION: GAF Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1 / R905.2.6.1
CONTINUED COMPLIANCE: This Evaluation Report is valid until the named product(s) changes, the referenced Quality
Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s), the Quality Assurance or the production facility location(s). NEMO|etc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words “NEMO|etc. Evaluated” may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized by Robert
Nieminen, P.E. on 02/18/2019. This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO|etc. does not have, nor does it intend to acquire, or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO|etc. is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing produ cts for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO|etc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project
on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically
for that purpose.
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.01.08-R23
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL10124-R21
GAF Asphalt Roof Shingles Revision 23: 02/18/2019
Page 2 of 6
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated compliance with the
following sections of the 6th Edition (2017) Florida Building Code and Florida Building Code, Residential Volume
through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements
and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.4, R905.2.3 Physical Properties ASTM D1970 2015
1507.2.5, R905.2.4 Physical Properties ASTM D3462 2010
1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2016
1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158 2011
1507.2.7.1, R905.2.6.1 Wind Resistance TAS 107 1995
3. REFERENCES:
Entity Examination Reference Date
PRI (TST 5878) Physical Properties GAF-025-02-01 03/27/2002
PRI (TST 5878) ASTM D3462 GAF-059-02-01 09/02/2004
PRI (TST 5878) ASTM D3462 GAF-080-02-01 05/25/2005
PRI (TST 5878) Physical Properties GAF-324-02-01 12/01/2011
PRI (TST 5878) ASTM D1970 (QuickStart) GAF-340-02-01 03/13/2012
PRI (TST 5878) Wind Driven Rain GAF-407-02-01 01/21/2013
PRI (TST 5878) Wind Driven Rain GAF-895-02-01 11/20/2018
PRI (TST 5878) Wind Driven Rain GAF-896-02-01 11/20/2018
PRI (TST 5878) ASTM D3462 GAF-897-02-01 11/08/2018
PRI (TST 5878) ASTM D3462 GAF-898-02-01 11/08/2018
PRI (TST 5878) ASTM D3462 GAF-899-02-01 11/15/2018
UL (TST 1740) ASTM D3462 93NK6295 11/29/1993
UL (TST 1740) ASTM D3462 99NK43835 01/12/2000
UL (TST 1740) TAS 107 94NK9632 03/29/2000
UL (TST 1740) ASTM D3462 01NK06632 02/02/2001
UL (TST 1740) ASTM D3161, TAS 107 01NK9226 05/21/2001
UL (TST 1740) ASTM D3161 01NK37122 12/18/2001
UL (TST 1740) ASTM D3462 01NK37122 12/19/2001
UL (TST 1740) ASTM D3161, TAS 107 02NK12980 04/10/2002
UL (TST 1740) ASTM D3161, TAS 107 02NK30871 09/09/2002
UL (TST 1740) ASTM D3161 03CA5367 03/11/2003
UL (TST 1740) ASTM D3462 03NK26444 10/17/2003
UL (TST 1740) ASTM D3462 04NK13850 06/07/2004
UL (TST 1740) ASTM D3161 04NK13850 06/23/2004
UL (TST 1740) ASTM D3161 04NK30546 03/10/2005
UL (TST 1740) ASTM D3462 04NK22009 05/06/2005
UL (TST 1740) ASTM D3161 04NK22009 05/09/2005
UL (TST 1740) ASTM D3462 05NK27924 02/10/2006
UL (TST 1740) ASTM D3161 05NK27924 02/11/2006
UL (TST 1740) ASTM D3161, D3462 06CA18077 06/05/2006
UL (TST 1740) ASTM D3161, D3462 06CA18074 06/16/2006
UL (TST 1740) ASTM D3161, D3462 06CA35251 10/18/2006
UL (TST 1740) ASTM D3462 06CA31603 12/01/2006
UL (TST 1740) ASTM D3161, D3462 06CA41095 12/27/2006
UL (TST 1740) ASTM D3161 07NK05228 03/13/2007
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.01.08-R23
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL10124-R21
GAF Asphalt Roof Shingles Revision 23: 02/18/2019
Page 3 of 6
Entity Examination Reference Date
UL (TST 1740) ASTM D3161 06CA31611 04/04/2007
UL (TST 1740) ASTM D3161 06CA61148 04/09/2007
UL (TST 1740) ASTM D3161, D3462 07CA31742 11/08/2007
UL (TST 1740) ASTM D3161, D7158, D3462 08CA06100 03/13/2008
UL, LLC. (TST 9628) ASTM D3161 4788698165 03/24/2008
UL (TST 1740) ASTM D3161, D3462 07CA55908 04/01/2008
UL (TST 1740) ASTM D3161, D3462 09CA10592 03/26/2009
UL (TST 1740) ASTM D3161, D3462 09CA06856 05/15/2009
UL (TST 1740) ASTM D3161, D7158, D3462 09NK06647 08/01/2009
UL (TST 1740) ASTM D3161, D7158, D3462 09CA27281 08/27/2009
UL (TST 1740) ASTM D3161, D7158, D3462 10CA35554 03/05/2010
UL (TST 1740) ASTM D3161, D7158, D3462 10CA13686 05/15/2010
UL (TST 1740) ASTM D3462 10CA07264 05/27/2010
UL (TST 1740) ASTM D3462 10CA11953 10/29/2010
UL (TST 1740) ASTM D3161, D7158, D3462 10NK11951 10/30/2010
UL (TST 1740) ASTM D3161, D7158, D3462 10NK12070 11/04/2010
UL (TST 1740) ASTM D3161, D7158, D3462 08CA06100 01/30/2010
UL (TST 1740) ASTM D3161, D7158, D3462 10CA53934 03/31/2011
UL (TST 1740) ASTM D3161, D7158, D3462 11CA48924 10/22/2011
UL (TST 1740) ASTM D3161, D7158, D3462 11CA47919 12/03/2011
UL (TST 1740) ASTM D3161, D7158, D3462 11CA48408 12/08/2011
UL (TST 1740) ASTM D3161, D7158, D3462 11CA48725 12/09/2011
UL, LLC. (TST 9628) ASTM D3462 12CA34891 10/12/2012
UL, LLC. (TST 9628) ASTM D3161, D7158, D3462 12CA58151 02/15/2013
UL, LLC. (TST 9628) ASTM D3161 12CA38083 02/26/2013
UL, LLC. (TST 9628) ASTM D3161 13CA32332 06/18/2013
UL, LLC. (TST 9628) ASTM D3161 13CA37934 08/02/2013
UL, LLC. (TST 9628) ASTM D3161, D7158, D3462 4786875675 07/17/2015
UL, LLC. (TST 9628) ASTM D3161, D7158, D3462 4787434542 05/17/2016
UL, LLC. (TST 9628) ASTM D3161 4788669132 12/13/2018
UL, LLC. (TST 9628) ASTM D3161 4788891098 02/14/2019
UL, LLC. (QUA 9625) Quality Control Service Confirmation 10/18/2018
4. PRODUCT DESCRIPTION:
4.1 ACCESSORY STARTER STRIPS:
4.1.1 Pro-Start® Eave/Rake Starter Strip Shingles and WeatherBlocker™ Premium Eave/Rake Starter Strip Shingles are
starter strips for asphalt roof shingles. Meets ASTM D3462.
4.1.2 QuickStart® Peel & Stick Starter Roll is a is a mineral-surfaced, fiberglass-reinforced, self-adhering SBS modified
bitumen starter strip, nominal 9-inch x 33 ft roll, for use with asphalt shingles with exposure of 6-inch or less.
Meets ASTM D1970.
4.1.3 StarterMatch™ Starter Strip Shingles are color-coordinated starter strips for use with Grand Canyon® and Grand
Sequoia® series asphalt shingles. StarterMatch™ are installed as the second starter for Grand Canyon® and Grand
Sequoia® series installations. Meets ASTM D3462.
4.2 ASPHALT SHINGLES:
4.2.1 Marquis WeatherMax®, Royal Sovereign® and Sentinel® are a fiberglass reinforced 3-tab asphalt roof shingles.
4.2.2 Camelot®, Camelot® II, Fortitude™, Glenwood™, Grand Canyon®, Grand Sequoia®, Grand Sequoia® IR, Grand
Sequoia® ArmorShield™, Sienna®, Timberline® American Harvest®, Timberline® ArmorShield™ II, Timberline®
Natural Shadow®, Timberline HD®, Timberline® Cool Series®, Timberline Ultra HD® and Woodland® are fiberglass
reinforced, laminated asphalt roof shingles.
4.2.3 Slateline® is a fiberglass reinforced 5-tab asphalt roof shingle.
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.01.08-R23
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL10124-R21
GAF Asphalt Roof Shingles Revision 23: 02/18/2019
Page 4 of 6
4.3 HIP & RIDGE SHINGLES:
4.3.1 Seal-A-Ridge® Ridge Cap Shingles, Seal-A-Ridge® ArmorShield™ Ridge Cap Shingles and Timbertex® Premium Ridge
Cap Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for
fire ratings of this product.
5.4 Wind Classification:
5.4.1 The GAF asphalt shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for use in
all wind zones up to Vasd = 150 mph (Vult = 194 mph). Refer to Section 6 for installation requirements to meet this
wind rating.
Note: Classification by ASTM D7158 applies only to exposure category B or C, as defined in FBC 1609.4.3, and a
mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions
outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.4.2 The GAF hip & ridge shingles noted in Section 4.3 are Classified in accordance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up to Vasd = 150
mph (Vult = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3.
6. INSTALLATION:
6.1 GENERAL:
6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle manufacturer’s
minimum requirements.
6.1.2 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be Locally
Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3.
6.1.3 Fasteners shall be in accordance with manufacturer’s published requirements, but not less than FBC 1507.2.6 or
R905.2.5. Staples are not permitted.
6.1.4 GAF asphalt shingles are acceptable for use in reroof (tear-off) or recover applications, subject to the limitations set
forth in FBC Section 1511 or R908 and CertainTeed published installation instructions.
6.2 STARTER SHINGLES OR STARTER STRIP:
6.2.1 Installation of Pro-Start Eave/Rake Starter Strip Shingles, WeatherBlocker Premium Eave/Rake Starter Strip Shingles
and QuickStart Peel & Stick Starter Roll shall comply with the GAF current published instructions.
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.01.08-R23
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL10124-R21
GAF Asphalt Roof Shingles Revision 23: 02/18/2019
Page 5 of 6
6.3 ASPHALT SHINGLES:
6.3.1 Installation of asphalt shingles shall comply with the GAF current published instructions, using minimum four (4) nails
per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions:
➢ Camelot, Camelot II, Grand Canyon, Grand Sequoia, Grand Sequoia IR, Grand Sequoia ArmorShield, and
Woodland require minimum five (5) nails per shingle.
➢ Slateline requires minimum six (6) nails per shingle.
6.3.2 Fasteners shall be in accordance with manufacturer’s published requirements, but not less than FBC 1507.2.6 or
R905.2.5. Staples are not permitted.
6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required.
Contact the GAF for details.
6.4 HIP & RIDGE SHINGLES:
6.4.1 Installation of Seal-A-Ridge Ridge Cap Shingles
and Seal-A-Ridge ArmorShield Ridge Cap
Shingles shall comply with the GAF current
published instructions with a minimum two (2)
nails, minimum 3/8-inch head diameter, per
shingle and nominal 0.25-inch diameter beads of
Henkel “Loctite PL S30 Roof & Flashing Sealant”.
6.4.2 Installation of Timbertex Premium Ridge Cap
Shingles shall comply with GAF current published
instructions with a minimum two (2) nails,
minimum 3/8-inch head diameter, per shingle
and beads of Sonneborn “NP1 Gun Grade
Polyurethane Sealant” or Henkel “PL Roofing and
Flashing Sealant”.
6.4.3 Fasteners shall be in accordance with GAF published requirements, but not less than FBC 1507.2.6 or R905.2.5.
Staples are not permitted.
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.01.08-R23
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL10124-R21
GAF Asphalt Roof Shingles Revision 23: 02/18/2019
Page 6 of 6
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table
1507.2.7.1 / R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC – QUA9625; (414) 248-6409; karen.buchmann@ul.com
- END OF EVALUATION REPORT -