HomeMy WebLinkAboutProduct Approval (3) 10/25/2018 Florida Building Code Online
Business 1
& Professional Regulation
W
BCIS Home l Log In l User Registration I Hot Topics I Submit Surcharge I Stals&Facts Publications Contact Us BCIS Site Map I Links I Search l
Florida
QPProduct Approval
USER:Public User
ProductApproval Menu>Product or Application Search>Application List>Application Detail
FL# FL10674-R13
Application Type Revision
Code Version 2017
Application Status Approved
Comments RECEIVE®
Archived ❑
Product Manufacturer Owens Corning
• APR �. 5 2019
Address/Phone/Email One Owens Corning Parkway
Toledo,OH 43659 ST. Lucie County, ��� ,�n___
(740)404-7829
greg.keeler@owenscorning.com
Authorized Signature Greg Keeler
greg.keeler@owenscorning.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Corning PKWY
Toledo,OH 43659
(419)376-8360
mel.sancrant@owenscornig.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
CLCompliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
0 ❑ Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J.M.Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 05/16/2020
■■ Validated By John W.Knezevich, PE
rte, Validation Checklist-Hardcopy Received
! Certificate of Independence FL10674 R13 COI 2017 01 COI Nieminen.g_df
Referenced Standard and Year(of Standard) Standard Year
ASTM 63161 2016
ASTM D3462 2010
ASTM D7158 2011
Equivalence of Product Standards
Certified By
Sections from the Code
hftps://floridabuilding.org/pr/pr_appjtl.aspx?param=wG EVXQwtDqtBNbEY5V%2boQT%2b6w7ah Reg ICQ8ucR6ixEBFhs7tvJgZew%3d%3d 1/2
10/25/2018 Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted 10/10/2017
Date Validated 10/11/2017
Date Pending FBC Approval 10/15/2017
Date Approved 12/12/2017
Summary of Products
FL# Model,Number or Name Description
10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab,5-tab,laminated,starter and hip&ridge shingles
Shingles and Starters
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL10674 R13 II 2017 10 FINAL ER OC ASPHALT
Approved for use outside HVHZ:Yes SHINGLES FL10674-R13.pdf
Impact Resistant:N/A Verified By: Robert J. M.Nieminen PE-59166
Design Pressure: N/A Created by Independent Third Party:Yes
Other: Refer to ER,Section 5. Evaluation Reports
FL10674 R13 AE 2017 10 FINAL ER OC ASPHALT
SHINGLES FL10674-R13.pdf
Created by Independent Third Party: Yes
Back Next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Accessibilily,Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
® cChcck 8
Credit Card
Safe
https://fioridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtBNbEY5V%2boQT%2b6w7ahRegICQ8ucR6ixEBFhs7tvJgZew%3d%3d 2/2
J a
EXTERIOR RESEARCH &DESIGN, LLC.
Certificate of Authorization 119503
TRINIT Y I 353 CHRISTIAN STREET, UNIT
QOERD OXFORD,CT 06478478
(203)262-9245
EVALUATION REPORT
Owens Corning Evaluation Report 037940.02.12-118
One Owens Corning Parkway F1.10674-1113
Toledo,OH 43659 Date of Issuance:02/06/2012
(740)404-7829 Revision 8: 10/09/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: 40wens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1/R905.2.6.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E.if the
product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity)ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
it
�T[
���FS�^` �'''r{- The facsimile seal appearingwas authorized b Robert
Florida Registration No.59166,Florida DCAANE1983
Robert J.M.Nieminen,P.E. 'F,,; � `� Nieminen,P.E.on 10/09/2017.This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity]ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINITY I ERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning, have demonstrated
compliance with the following sections of the 6th Edition (2017) Florida Building Code and Florida Building Code,
Residential Volume through testing in accordance with the following Standards. Compliance is subject to the
Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011
3. REFERENCES:
Enifty Examination Reference Date
UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007
UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012
UL LLC(TST9628) Physical Properties 06CA20263, 04/18/2006
UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012
UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014
UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC(TST9628) Physical Properties Classification letter 02/13/2014
UL LLC(TST9628) Physical Properties Classification letter 10/02/2015
Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various
UL LLC (QUA9625) Quality Control Service Confirmation Exp.05/16/2020
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic and Supreme'are fiberglass reinforced,3-tab asphalt roof shingles.
4.1.2 Berkshire'are fiberglass reinforced,4-tab asphalt roof shingles.
4.1.3 Devonshire"'are fiberglass reinforced,5-tab asphalt roof shingles.
4.1.4 Duration', TruDefinition' Duration', Duration' Premium Cool, TruDefinition' Duration' Designer Color
Collection, Tru Definition'Oakridge', Oakridge' and WeatherGuard' HP are fiberglass reinforced, laminated
asphalt roof shingles.
4.2 Hip&Ridge Shingles:
4.2.1 Berkshire' Hip & Ridge Shingles, High Ridge, WeatherGuard' HP Hip & Ridge Shingles, ProEdge Hip & Ridge
Shingles and DuraRidgell Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles.
4.3 Accessory Starter Strips:
4.3.1 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory
for fire ratings of this product.
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8
Certificate of Authorization 119503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 2 of 8
TRINITY I ERD
5.4 Wind Classification:
5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1
and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H, indicating the shingles are acceptable
for use in all wind zones up to Vasd = 150 mph (Vul, = 194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are
Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F, indicating the
shingles are acceptable for use in all wind zones up to Vasa=150 mph (Vit=194 mph). Refer to Section 6 for
installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C, as'defined in FBC 1609.4.3,and a mean
roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions
outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval,or be Locally Approved per Rule 61G20-3,per FBC 1507.2.3,1507.2.4 or R905.2.3.
6.2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using
minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following
exceptions:
➢ Berkshire®shingles require minimum five(5)nails per shingle.
➢ WeatherGuard®HP shingles require minimum six(6)nails per shingle.
➢ Devonshire TM shingles require minimum six(6)nails per shingle.
➢ Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. See figures below for details.
6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus:
Feltunderlaymetn Deck FeEtmded+y+ Deck SWedhered
Weathertack9
Self-adhered underlaymem
WeatherLo&
underlayment
Ddpedge
edg Drip edge
' Naas edge
located
Nails located 2-3"from cave
21-3'from gave
Install fast Self-sealing adhesive S� �og adhesive
StonerStr�'p positioned along eave with
iB*remter�rStnpPk° positioned along eave
shingle with \ wth6'remored
6"removed Starter Strip shingle overhangs eaves and rakes 114'44' Starter p Mrs overhangs eaves and rakes t/4-314°
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R8
Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1113
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 3 of 8
(-)o
TRINITY I ERD
6.2.6 Minimum Nailing—Classic®&Supreme:
Normol Mansard or Aron para Normal Mansard or Area pan
Wind Areas High Wind dy Wind Areas High Wind desvanas y
Arca pare vientos normales Areas vlontoa fuerres Ana para vientos normales Areas vientos faartes.
t2 —41
12t
.. . . .
g"Eirposure 6 1118•Exposure
Erposieldn Fxposialdn
6.2.7 Minimum Nailing—Berkshire®:
Sealant strip
Sealant strip
La fka de saWa La tirade segador
t" 8th" 9 Yf 9 W 8 Yf t "8 W- 8 W" 8 W, BW" i
t" �'J 1 t• J
r
- r
r
Standard Fastening Pattern 6-Nail Fastening Pattern
Sealarastrip
La tba de sdkdor
t"8 Yf 8 y BYf 8 Y
r r_
1
Asphaft roof'erge mens
cemento de teshode asfatto
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design,U.C. Evaluation Report 037940.02.12-118
Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1113
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 4 of 8
(-)o
TRINITY I ERD
6.2.8 Minimum Nailing—DevonshireTM':
V 7" 8.t 8" 8a 7H
N
paras Mails
9/8°exposure Sealant location 1"
Exposieidn de 5.5/8 pull; Ubieacibn del seilador
Ten 1"Spots of Asphalt Roof Cement
Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern
•
6.2.9 Minimum Nailing — Duration®, TruDefinition® Duration, Duration° Premium Cool & TruDefinition
•
Duration Designer Color Collection:
4-Nall Fastening Patterne-Nall Fastening Pattern
SlaeNat�tasteNng arta wwn Surma=rasWWng ami vndm
Nall.Typical NA Typical
1• 1r 1r 1^ t• tr I I 12-
7-
s.�w�,+�+ • r..>.w • a... :...v® • •d.c...aa • sL �.o •o.�c.m•s..xn• •
F718•6618• F718•6418-
�your .o..� F1 F� F� , l
Standard Fastening Pattern 6-Nail Fastening Pattern
Fastening for Slopes Greater Than 21:12
SMN"N tuhning•n•width
NaB.lypkal
r tr tr
Eve•ss16•
0
Foul1•.pob c1bpMll Rooflg C..nt
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design,U.C. Evaluation Report 037940.02.12-118
Certificate of Authorization#9503 CH EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1113
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 5 of 8
TRINITY ERD
6.2.1 Minimum Nailing—TruDefinition®Oakridge®,Oakridge®:
4 Nall Pattern 6 Nail Pattem
Esquema con 4 davos Esquema con 6 davos
�I 1" T
i� 12 —>I 12. V
66/8"Exposure � 55/9"Exposu Nails
Evposiei6nde56/8pulg. Clavas Erpos/N6nde5618prdg. 6Big"ExposuIe Clavas 5Sir Exposu
Expcdd6n de 56/8 ping. Exposiddn de 66/8 pulg.
Standard Fastening Pattern 6-Nail Fastening Pattern
Fastening for Slopes Greater Than 21:12
SvatWR&fa+tening maa w1EN
Nae.7ypiul
r +r 1r r
o-ve•sve-
�r
Fom+"Spots 1111+pWR Roofing Cetnant
Mansard or Steep Slope Fastening Pattern
6.2.1 Minimum Nailing—WeatherGuard®HP:
MR
.�:•
CARO ILMNIido�7hr��+N. id&il�
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-118
Certificate of Authorization#9503 6rR EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 6of8
��TRINITYIERD
6.3 Hip&Ridge Shingles:
6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, WeatherGuarde HP Hip and Ridge Shingles
and ProEdge Hip & Ridge Shingles shall comply with the Owens Corning current published instructions,
using four (4) nails per shingle. Installation of DuraRidgeT" Hip & Ridge Shingles shall comply with the
Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning
published information on wind resistance and installation limitations, including the use of hand-sealing for
wind warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge:
Flg.1 nDT Fig.2
Vd
<— Dlre dnd TopMav Sldalnew
Dtreotbn A
NaUs----- P Nails Nails
4 r rTop r I
I I Lamulatea
A I I 4' Piece
A 7' T
Q I I I
til
I I I I I
EMOsure �I
�I
I
I
' I
I
I
6.3.4 Minimum Nailing—WeatherGuarde HP Hip and Ridge:
Fig.C Hip&Ridge Shingle Fastening
Fig.A v 4 TopVlevi
prewObg Wind
<—
Direction A
A
A i I Nails Nails
A I I T•
47' 2"
I 1' T
A I I I 1
Espowle
S' Espcsula
II-- T7
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-118
Certificate of Authorization 119503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 7 of 8
t
TRINITY I ERD
6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles:
Prevailing Standard
Wind DirectionFastening
Sealant Strip Pattern
6"Exposure �.�
t2" 1 Sealant
Fasten Th" 711?u 6"Exposure
Cover Exposed 1
Fasteners with
Roof Cement
Mom
6.3.6 Minimum Nailing—DuraRidge'"Hip&Ridge Shingles:
Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning
published installation instructions for their minimum requirements.
PrarnifngWindDirK6cn Yue lfle n
Dirnaiandornimntadrvunt II- Vbtssuperlor I"I
D imcdtn dol►unto prarlorniwra
t Nail
Clou
s
Nall A
e•mos Coming SurcNail• • X010
dols o i I
mrorN I I I
s
9
ir
i
I
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1/R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625;(631)546-2458; Kanchi.Agrawala-Dokania@ul.com
END OF EVALUATION REPORT-
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8
Certificate of Authorization X9503 0 EDITION(2017)FSC NON-HVHZ EVALUATION F1.30674-1113
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 8 of 8