HomeMy WebLinkAboutEngineering, Modified Bitumen - ► CAD 5— 0 Architectonic Inc May2,2019 RECEIVED MAY 0 6 2019 Saint Lucie County Building Department Permitting Department Attn: Roof Permit Plan Review St. Lucre County • 2300 Virginia Avenue Ft. Pierce, FL 34982 Re: Roofing specification prepared for the St. Lucie County Building Dept.for the structure located at 1103 Osceola Dr.,St. Lucie County. Manufacturer: Tri-Built Roofing Products Profiles: Tri—Built Modified, FL#16027.1,System W-5 Code: FBC 2017;Section R 905.10 Wind Speed: 160 MPH; Ultimate Design Wind Speeds Exposure: B Mean Roof Height: 30' Maximum Pitch: 'A/12 Required Design Pressure: Zone1:-26 Zone 2:-41 Zone3:-57 Maximum Uplift Pressure: -90 Base: SBS-SA Cap: APP-TA Roof Decking: Existing5/8" plywood sheathing thing to be nailed w 8d x2 ring shank nail' isI @ 6" O.C.thru out Zone 1,4"O.C. perimeter&6"O.C.field Zone 2, and 4"O.C.thru out Zone 3. The above approved, as per Florida Building Code Compliance acceptances, 2017 Florida Building Code, and the Manufacturer's recommendations. ', .R spectfull*Submitted .\ Michael eal /i a Y I „N`. �Architec nie lnc� /72 806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg#AA26003348 1 of 1 i I