HomeMy WebLinkAboutProject Information % Sheffield MaKeinonv roqcar6onate,Dome Clc;u:1Br6*pzc(CB)- 25% 6o% .90 - -97 - 0.7(ASHRAE) Clear/Clear(CC) 7400 89% go .97 1.02 (ASHRAE) Cleir/Ga-ly(CG) 43% 60% go .97 0.7(ASHRAE) Bronvc/Bronvc(BB) 07% 36% .90 .97 0.49 (ASHRAE) Cleor/Viirc (CW) 23% 40016 .90 .97 0.71 (ASHRAE) REJMVCb'�' insulated Glass Performance MAY 0 8 ".1019 ucie County,Permitting LoE366(Low E Cubed)/Argon Gas: 0.27 0.241 0.43 66% BronzeTini-/Argoii Gas: 0.63 0.31 0.52 61'Yo Gray'rin(/Argon Gas: 0.63 0.31 0.52 61% L ' ; y P Ll Mill Finish White Powdercoar Bronze Anodized Custom Color Powdercoat Custom Color Powdercom Approvals include multiple Miarni-Dade County Product Control NC)As; Florida Building Commission, FBC 2418-R3 (2010); Texas Department of Insurance,TDI Report(s)SK-13 &SK-18 All Maxim Skylights are tested and conform to AAMA/WDIVIA/C SA I 0I/I.S.2/A440-05 and all, or part:,of the following standards:ASTM E283,ASTM E330,ASTM E331,ASPM E547,ASTM El 886, Missile Level C as specified in ASTM E1996-99,TAS 201-94,TAS 202-94,TAS 203-94,and ASTM El 300-02/03. • All Maxim Skylights are third part3,certified to performance compliance and quality assurance by the National Accreditation Management Institute(NIAMI). • Available in any size or shape up-to 25 square feet, the largest impact resistant insulated glass skylight available. • Insulated Glass for maximum energy efficiency available as'lempered,Laminated and DuPont"SentryGlas' Nus Impact resistant. Unlimited Configurations to meet any conditions. . Optional curb assembly w/prefinished white interior,solid wood curb and aluminum counterflashing. lJi . I nsulated glass is tested to-200psf negative pressure for a+/-100psf Design Pressure. o All Maxim insulated glass comes with XL Edge'technology providing0 the lowest failure rate in the industry. Developed in part from our suppliers 45 years of experience in manufacturing dual-seal silicone insulated glass. o Mill Finish,Bronze Anodized,Clear Anodized or an unlimited number of powdercoat colors are also available. . All insulated 1 glass is covered b the manufacturer for 20 years y Curb Mount available up to 36 square feet&Sclf-'Flashing up to 32 square feet in any size or shape. Polycarbonate domes are tested to-120psf&+180psf for a+1-60psf Design Pressure. • Sheffield plastics Makrolon'SL UV enhanced polycarbonate outer domes for the ultimate in ultraviolet light protection. • Virtually unbreakable polycarbonate domes meet large&,small missile impact rating. • Scaled double domes prevent moisture from occurring between the domes. Polycarbonate glazing sneers UL 972 forced entry protection. Stainless steel fasteners eliminate rust and corrosion. `Any lype of,dealling performed on the rool,including removal of mold,mildew,fimps,or dirt,by pressure ofanykind with water or chemical rucaos will cl;nnage pulyt;arbonare donics and void:my warranty.A detailed insulated glass warranty is avnilahle upon request.WARNING:SKYLIGHTS MAY NOT SUPPORT LIVE LOADS!\Viffle these skylights have passed Testing fol large and small missile impact resistance,1000 frAbs fill protection rcsismsice and up To 200p1*.positive pressure testing,they are not intended fior any Jix,c load!Do not swrid.lil-Ican.or rest oually pan of lite Skylight. Corporate Florida 1630'1'crre Colony Court- Dallas,'I"exns 75212.6221 1818 7"'Avenue North,Suite 2 Like Vvorrh, Florida 30461 Toll Free 888-222-4898-Fax 214-905-2024 Toll Free 800-367-8168 Fax 561-588-9283 Product Conformance to 61h Edition (2017) Florida Building Code Rule 61G20-3 F.A.C. ) Project No. 418-0102 ( 1/8/18 1 Page 1 of 2 Product Manufacturer Product Name, Model and/or Description Maxim Industries,Inc. Dade Curb Mount Skylight Polycarbonate Glazed Aluminum Skylight 1630 Terre Colony Court Dade Self Flashing Skylight Polycarbonate Glazed Aluminum Skylight Dallas,TX 75212 Florida Product Approval No.: FL2418 RECEIVED Code: 6th Edition(2017)Florida Building Code MAY 0 S 2019 Compliance Method: hT. kucl©County, Permitting • Product Approval Rule 61G20-3.007(1)(f)—Self-Affirmation • Product Approval Rule 61G20-3.005(1)(d)—Product Evaluation Report by a Licensed Professional Engineer • Product Approval Rule 61G20-3.015(4)(d)—Equivalency of Standards • Product Approval Rule 61G20-3.005(1)(e)—project specific approval by the local authorities having jurisdiction in accordance with alternate methods and materials authorized in the Code(Section 104.11) Code Conformance Review:The undersigned has reviewed the above referenced Florida Product Approval and associated documents and found all drawings,reports,referenced test standards,and testing as noted in the approved documents to be incompliance with the 6th Edition(2017)Florida Building Code. has been concluded that no revisions or changes to the referenced standards have occurred between the following(where licable)that affect the results of design,testing or engineering of the approved product(s). 0 • Chapter 35 of the 511 Edition(2014)Florida Building Code compared to Chapter 35 of the 6th Edition(2017)Florida . Building Code • Chapter 46 of the 5th Edition(2014)Florida Residential Code compared to Chapter 46 of the 6th Edition(2017)Florida Residential Code LU • Test Protocols for HVHZ/5t''Edition(2014)Florida Building Code compared to Test Protocols for HVHZ/6t''Edition (2017) Florida Building Code,specifically the following where applicable. o TAS 201-94,TAS 202-94 and TAS 203-94 Conformance Review of skylight glazing material Manufacturer(s)and Component Approval per Miami-Dade NOA: I • The currently issued Miami-Dade NOA for component approval to the Florida Building Code for Covestro,LLC Makrolon Polycarbonate Sheets was reviewed and found to be in compliance with the 6th Edition(2017)Florida Building Code.Covestro,LLC Miami-Dade NOAs can be found here. Therefore,all test standards used in testing and all design standards used in design and engineering of the currently approved product(s)remain valid for compliance to the 6th Edition(2017)of the Florida Building Code. Certification Agency Certificate(attached) • N1009198-135,Expiration-12/31/21 for Dade Self Flashing Skylight- • N1009198.01-115,Expiration 12/31/21 for Dade Curb Mount Skylight Installation Instructions(available from Product Manufacturer) • Drawing No.DSF1507,Dated 7/10/15,signed&sealed by T.Berman,P.E. • Drawing No.DCM1507,Dated 7/10/15,signed&sealed by T.Berman,P.E. ��A!111111111F PTC Product Design Group, LLC I PO Box 520775 1 Longwood, FL 32752-0775 r'/L 321-690-1788 1 FBPE Certification of Authorization No. 25935 Product Conformance to 6th Edition (2017) Florida Building Code Rule 61G20-3 F.A.C. I Project No. 418-0102 1 1/8/18 ( Page 2 of 2 �isru��rr Certificate of InRupe 61G20"3.009qndence per roduct Approval ` ••....q �-;GEN Digitally signed PTC Product Design Group,LLC and Robert J.Amoruso,P.E. V'4* N49752 ' Oby Robert .1does not have,nor will acquire,any financial interest in thecompany manufacturing or distributing products)covered %- = Amoruso by this Product Evaluation Report. +A: STArEO w, .-Date:201 s.01 .0s !. ;'It% � . 10 ; ?. t1 PTC Product Design Group,LLC and Robert J.Amoruso,P.E. ''j�� ss{3NA1.E tG��! ' 6;.75:50 _QS�VQ� do not have,nor will acquire any financial interest in any �i7b � other entity involved in the approval process or testing of Evaluated the productEvaby: s)covered by this Product Evaluation Report. Roberta ated b P.E. EL P.E.License No.49752 •��►•�► PTC Product Design Group, LLC I PO Box 520775 1 Longwood, FL 32752-0775 rte.► 321-690-1788 1 FBPE Certification of Authorization No. 25935 • 1. NOTICE OF PRODUCT CERTIFICATION CERTIFICATION NO: NI009198-R5 u DATE: 12/30/2007 CERTIFICATION PROGRAM: Structural ` COMPANY: Maxim l CODE: M-1256-1 REVISION DATE: 08/21/2017 To verify that the"Notice of Product Certification"is valid,please visit www.NAWCertifiication.com to assure that the product is active and currently listed.This certification represents product conformity to the applicable specification and thatcertification criteria has been satisfied. A NA1VII approved certification label must be applied to the product to claim certification status. Please review and advise NAMI if any corrections are required to this document. COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION Maxim Industries,Inc. Series "Dade Self-Flashing" 1630 Terre Colony Court Polycarbonate Glazed Aluminum Skylight Dallas,Texas 75212 Configuration:O Glazing:Exterior Dome-0.118"Hyzod Polycarbonate w/8"rise/Interior Dome-0.118"Hyzod Polycarbonate w/4"rise Overall: W-416" DLO: W-39" H-816" 1-1-79" SPECIFICATION PRODUCT RATING TAS 201/202/203-94 Design Pressure: +60/-60 psf Large Missile Impact Rated Product Tested By: Architectural Testing,Inc. Report No: ATI-01-43381.01 Expiration Date: December 31,2021 Administrator's Signature: NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE,INC. 4794 George'Washington Memorial Highway Hayes,VA 23072 Tel:(804)684-5124 Fax: (804)684-5122 NOTICE OF PRODUCT CERTIFICATION CERTIFICATION NO: NI009198.01-R5 DATE: 12/30/2007 CERTIFICATION PROGRAM: Structural COMPANY: Maxim CODE: M-1256-1 REVISION DATE: 08/21%2017 To verify that the"Notice of Product Certification"is valid,please visit www.NAMICertification.com to assure that the product is active and currently listed.This certification represents product conformity to the applicable specification and that certification criteria has been satisfied. A NAM approved certification label must be applied to the product to claim certification status. Please review and advise NAM if any corrections are required to this document. COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION Maxim Industries,Inc. Series "Dade Curbmount" 1630 Terre Colony Court Polycarbonate Glazed Aluminum Skylight Dallas,Texas 75212 Configuration:O Glazing:Exterior Dome-0.118"Hyzod Polycarbonate w/8"rise/Interior Dome-0.118"Hyzod Polycarbonate w/4"rise Overall: W-414" DLO: W-4'0" H-814" H40" SPECIFICATION PRODUCT RATING TAS 201/202/203-94 Design Pressure: +60/-60 psf Large Missile Impact Rated Product Tested By: Architectural Testing,Inc. Report No: ATI-01-43381.01 Expiration Date: December 31,2021 Administrator's Signature: NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE, INC. 4794 George Washington Memorial Highway Hayes,VA 23072 Tel:(804)684-5124 Fax: (804)684-5122