HomeMy WebLinkAboutProduct Approval (2) FRECEIVED]M11A X1,6; 7 MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)31525-99
NOTICE OF ACCEPTANCE (NOA) ii,wii,.niiainidade..-ov/eeono„i,-
PrimeSource Building Products,Inc.
333 Manley Street
West Bridgewater,MA 02379
SCOPE: F11
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perforin in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to
revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: PrimeSource Grip-Rite ShingleLayment—Synthetic Roofing Underlayment
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miaini-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA#10-0921.11 and consists of pages 1 through 3.
The submitted documentation was reviewed by Alex Tigera.
MIAMI•DADE COUNTY NOA No.: 14-0520.11
Expiration Date: 08/26/19
Approval Date: 08/14/14
Page 1 of 3
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub-Category: Underlayment
Material: Polypropylene
SCOPE:
This acceptance is for Grip-Rite ShingleLayment �' Synthetic Roofing Underlayment as described in this
Notice of Acceptance, for use with approved prepared roof assemblies where ASTM D226 Type II
underlayment is specified and installed with prescribed approved fasteners and fastener densities.
PRODUCT DESCRIPTION:
Product Dimensions Test Product
Specification Description
Grip-Rite ShingleLayment Th' 4' x 250' rolls ASTM D226 A high-strength,woven polypropylene, coated,
Synthetic Roofing Type I&II non-skid roofing underlayment.
Underlayment
MANUFACTURING LOCATION:
1. Qindao, China
I+VIDENCE SUBMITTED:
Test Agency Test Identifier Description Date
TRINITYIERD P12460.03.09 ASTM D226 03/19/2009
INSTALLATION SPECIFICATIONS:
Grip-Rite ShingleLaymenJm Synthetic Roofing Underlayment
1. Grip-Rite ShingleLayment �' Synthetic Roofing Underlayment shall be installed in strict compliance with
applicable Building Code.
2. Grip-Rite ShingleLayment"'Synthetic Roofing Underlayment shall be installed with a minimum 4-inch
horizontal lap and 6-inch vertical laps in a shingle layer fashion.
3. Grip-Rite ShingleLayment'' Synthetic Roofing Underlayment shall be attached with PrimeSource Tin Caps-1-
5/8" Stress Plates or equivalent fasteners at 5"o.c. at the laps and three staggered rows 12"o.c.vertically and
12"o.c. horizontally in the field of the roll.
4. Grip-Rite ShingleLayment'' Synthetic Roofing Underlayment is a component used in roof asemblies. Roof
assemblies are approved under specific assembly Noticed of Acceptance.
5. Grip-Rite ShingleLayment Synthetic Roofing Underlayment may be used with Asphaltic shingles, Wood
shakes and shingles, Non-structural metal roofing, and quarry slate. Grip-Rite ShingleLayment �' Synthetic
Roofing Underlayment shall not be used as roof tile underlayment.
6. For fire classification of specific roof assemblies using Grip-Rite ShingleLayment — Synthetic Roofing
Underlayment refer to a current Approved Roofing Materials Directory for fire ratings of this product.
NOA No.: 14-0520.11
MIAMI•DAD;SCO uNTY Expiration Date: 08/26/19
Approval Date: 08/14/14
Page 2 of 3
r '
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly
evaluate the installation of this material.
LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance
with applicable building code.
3. Grip-Rite ShingleLayment �' Synthetic Roofing Underlayment shall be applied to a smooth, clean and dry
surface with deck free of irregularities. All nails in the deck shall be carefully checked for protruding heads.
Re-fasten any loose decking panels. Sweep the deck thoroughly to remove any dust and debris prior to
application.
4. Grip-Rite ShingleLayment 'T' Synthetic Roofing Underlayment shall not be hot mopped, refer to
manufacturer's published literature for product compatibility.
5. Grip-Rite ShingleLayment '' Synthetic Roofing Underlayment shall not be applied over an existing roof
membrane as a recover system.
6. Grip-Rite ShingleLayment" Synthetic Roofing Underlayment shall not be left exposed as a temporary roof
for longer than 30 days of application.
7. Grip-Rite ShingleLayment'' Synthetic Roofing Underlayment is a component used in roof system assemblies.
Roof system assemblies are approved under a specific Notice of Acceptance. Refer to Prepared Roofing
system Product Control Notice of Acceptance for listed approval of this product with specific prepared
roofing products.
8. Grip-Rite ShingleLayment'' Synthetic Roofing Underlayment may be used with any approved roof covering
Thl
Notice of Acceptance listing Grip-Rit- Synthetic Underlayment as a component part of an assembly in the
Notice of Acceptance. If Grip-Rite ShingleLayment ' Synthetic Roofing Underlayment is not listed; a
request may be made to the Authority Having Jurisdiction(AHJ) or the Miami-Dade County Product Control
Department for approval provided that appropriate documentation_ is provided to detail compatibility of the
products,wind uplift resistance, and fire testing results.
9. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo
and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County
Product Control Seal as shown below.
MIAMI•DADE COUNTY
END OF THIS ACCEPTANCE
NOA No.: 14-0520.11
MIAMI•DADE COUNTY
� Expiration Date: 08/26/19
Approval Date: 08/14/14