Loading...
HomeMy WebLinkAboutProduct Approval a a a H My tt :4„ zdF 00/ SCIS.Home Log In i User Registration y Hot Topic Submit Surcharge Stats&Facts Publications i Contact Us j BCIS Site Map Links } Search ,. Fonda Product Approval USER:Public User RECEIVE® 911�'x ""A'y?wk Product Approval Menu>Product or Application Search>Application List>Application Detail MAY 137 3 ''Ut9 FL# FL10124-R21 Application Type Revision ST. Lucie County, Permitting Code Version 2017 Application Status Approved Comments Archived 1 J Product Manufacturer GAF -Address/Phone/Email 1 Campus Drive Parisppany,NJ 07054 (800)766-3411 mstieh@gaf.com Authorized Signature Robert Nieminen Ireith@nemoetc.com Technical Representative William Broussard Address/Phone/Email 1 Campus Drive Parsippany,NJ 07054 (800)766-3411 Technica]QuestionsGAF@gaf.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/18/2021 Validated By John W.Knezevich,PE 60 Validation Checklist-Hardcopy Received Certificate of Independence FL10124 R21 COI 2019 01 COI NIEMINEN.odf Referenced Standard and Year(of Standard) Standard Year Uj ASTM D1970 2015 ASTM D3161. 2016 ASTM D3462 2010 ASTM D7158 2011 TAS 107 1995 Equivalence of Product Standards Certified By �k Sections from the Code Product Approval Method Method 1 Option D Date Submitted 02/19/2019 Date Validated 02/19/2019 Date Pending FBC Approval 03/02/2019 Date Approved 04/16/2019. Date Revised 04/17/2019 Summary of Products FL# Model,Number or Name Description 10124.1 GAF Asphalt Roof Shingles Fiberglass reinfor led 3-tab,laminated,5-tab and hip/ridge asphalt shingles Limits of Use Installation Instructions Approved for use in HVHZ:No FL10124 R21 II 12019 02 FINAL ER GAF ASPHALT Approved for use outside HVHZ:Yes SHINGLES FL10124-R21.odf Impact Resistant:N/A Verified By: Robert Nieminen PE-59166 Design Pressure:N/A Created by Independent Third Party:Yes Other:Refer to ER,Section 5. Evaluation Repo FL10124 R21 AE 2019 02 FINAL ER GAF ASPHALT SHINGLES FL10124-R21.Ddf Created by Independent Third Party:Yes Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.;:Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in I ponse to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However emailaddresses are public reco�d.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: M eCF.,a„'ej M Credit Card Safe MIAMI-DADE COUNTY MIAMI- PRODUCT CONTROL SECTION MIN 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economv GAF 1 Campus Drive Parsippany,NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Timberline HD®,Timberline®Natural Shadow®,Timberline®American Harvest®,and FortitudJm Shingles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA# 14-1022.20 and consists of pages 1 through 6. The submitted documentation was reviewed by Alex Tigera. ( NOA No.: 16-0811.11 MIAMI•DADE COUNTY t�t 1 ' Expiration Date: 02/21/22 Approval Date: 02/09/17 .Page 1 of 6 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub-Category: Asphalt Shingles Materials: Laminate Deck Type: Wood SCOPE This approves GAF Timberline HD®,Timberline®Natural Shadow®,Timberline American®Harvest®,and FortitudeTM Shingles as manufactured by GAF as described in this Notice of Acceptance. PRODUCT DESCRIPTION Product Dimensions Test Product Description Specifications GAF Timberline HD® 13 '/a"x 39 3/8' TAS 110 Fiberglass reinforced heavy weight asphalt Manufacturing roof shingle,with a laminate profile Locations#1,2,3,49 59 6,7 GAF Timberline Natural 13 '/4"x 39 3/8" TAS 110 Fiberglass reinforced heavy weight asphalt Shadow® roof shingle,with a laminate profile Manufacturing Locations#1,2,39 4,5,6,7 GAF Timberline®American 13 '/4"x 39 3/8" TAS 110 Fiberglass reinforced heavy weight asphalt Harvest® roof shingle,with a laminate profile Manufacturing Locations#2,4,5,6 GAF FortitudeTM 13 '/4"x 39 3/8" TAS 110 Fiberglass reinforced heavy weight asphalt Manufacturing roof shingle,with a laminate profile Location#4 MANUFACTURING LOCATION 1. Tampa,FL 2. Michigan City,IN 3. Baltimore,MD 4. Myerstown,PA 5. Ennis,TX 6. Tuscaloosa,AL 7. Dallas,TX NOA No.: 16-0811.11 MIAMI-DA ECouNn Expiration Date: 02/21/22 Approval Date:02/09/17 Page 2 of 6 r EVIDENCE SUBMITTED Test A2eney Test Identifier Test Name/Report Date Underwriters Laboratories,LLC ASTM D3462 4787344101 07/25/16 Underwriters Laboratories,Inc. ASTM D3462 11CA48924 10/24/11 Underwriters Laboratories,Inc ASTM D3462 l OCA21994 04/22/11 Underwriters Laboratories,Inc ASTM D3462 l OCA28717 07/26/11 Underwriters Laboratories,Inc. ASTM D3462 05CA47541 11/10/06 Underwriters Laboratories,Inc. ASTM D3462 06CA31580 11/30/06 PRI Asphalt Technologies,Inc. ASTM D3462 GAF-101-02-02 11/02/05 Underwriters Laboratories,Inc. ASTM D3462 06NK05159 08/09/06 PRI Asphalt Technologies,Inc. ASTM D3462 GAF-098-02-02 11/08/05 Underwriters Laboratories,Inc. ASTM D3462 02NK41809 08/11/02 Underwriters Laboratories,Inc. ASTM D3462 03NK26444 10/17/03 Center for Applied Engineering ASTM D3462 257989 05/13/97 Underwriters Laboratories,Inc. TAS 107 OINK45803 04/13/94 Underwriters Laboratories,Inc. TAS 107 06NK05159 08/09/06 Underwriters Laboratories,Inc. TAS 107 04NK04273 02/20/04 Underwriters Laboratories,Inc. TAS 107 05CA42840 11/11/05 Underwriters Laboratories,Inc. TAS 107 02NK41811 11/11/02 Underwriters Laboratories,Inc. TAS 107 03CA35209 10/17/03 Underwriters.Laboratories,Inc. TAS 107 04CA13850 08/30/04 Center for Applied Engineering TAS 100 257989 04/01/97 PRI Asphalt Technologies,Inc. TAS 100 GAF-044-02-01 01/13/04 PRI Asphalt Technologies,Inc. TAS 100 GAF-098-02-01 11/08/05 PRI Asphalt Technologies,Inc. TAS 100 GAF-101-02-01 11/09/05 PRI Asphalt Technologies,Inc. TAS 100 GAF-116-02-02 03/23/06 PRI Asphalt Technologies,Inc. TAS-100 ELK-083-02-01 10/16/02 ELK-084-02-01 10/15/02 ELK-085-02-01 10/14/02 ELK-086-02-01 10/24/02 ELK-087-02-01 10/21/02 ELK-088-02-01 10/16/02 ELK-107-02-01 10/09/03 ELK-108-02-01 10/09/03 ELK-109-02-01 10/09/03 LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. NOA No.: 16-0811.11 Q-Dr�eeouNr�r Expiration Date: 02/21/22 Approval Date: 02/09/17 Page 3 of 6 Z ' INSTALLATION 1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail'A', attached. 5. Nailing shall be in compliance with Detail 'B',attached. LABELING Shingles shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility, and following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. MIAMI•DADE COUNTY BUILDING PERMIT REQUIREMENTS 1. Application for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. NOA No.: 16-0811.11 MIAMI•DAD;COUNTY Expiration Date: 02/21/22 Approval Date: 02/09/17 Page 4 of 6 DETAIL A COURSE LAYOUT DECK FULL 5th 17"OFF 4th 11"OFF 3rd 6"OFF 2nd I FULL 1st 5-5/8"Exposure NOA No.: 16-0811.11 Mian I-DADE coExpiration Date: 02/21/22 Approval Date: 02/09/17 Page 5 of 6 r � DETAIL B OVERALL DIMENSIONS AND NAILING PATTERN 39-3/811 14-1/T-17-1/2" 14-1/2"-17-1/2" (368-445mm) (368-445mm) 6-1/2"-9-1/Z' {�*-- 6-1/2"-9-1/2" ail guide line 13-1/,4" hss-241mm) — — -♦- — —� — — •-- pss•zaimm) 5-3/4"m-15" 3Jm (146mm-159mm) 1!7'-2-1@^ - from bottom of shingle tis-sa elf seal adhesive on back ENHANCED NAILING PATTERN - six nails per shingle* required by some local codes and required for enhanced wind coverage on certain products. See limited warranty for details. These shingles MUST be nailed a nominal 6" (152mm)from bottom of of shingle, above the cut outs, as shown. Nails must not be exposed. END OF THIS ACCEPTANCE NOA No.: 16-0811:11 CMIAMI-DADE C Expiration Date: 02/21/22 Approval Date: 02/09/17 Page 6 of 6