HomeMy WebLinkAboutPERMIT PACKAGE 105/13/19 WINDOW/DOOR SCHEDULE APPROX IGNATION IMPACT PROTECTION ID OPENING ** DESIGNATION IMPACT NEW * REMARKS NO SIZE TYPE GLASS EXISTING (WXH) SHUTTER SHUTTER 1 23 x 23 CGI 130 FIXED X 17-0918.07 DP +80/-80 2 37 X 62.75 CGI110 SH X 17-1018.08 DP +75/-75 3 37 X 62.75 CGI110 SH X 17-1018.08 DP +75/-75 4 26.25 X 62.75 CGI110 SH X 17-1018.08 DP +75/-75 5 35.5 X 62.75 CGI110 SH X 17-1018.08 DP +75/-75 6 53 X 50.25 CGI120 HR X 17-0918.09 +65/-65 7 53 X 50.25 CGI120 HR X 17-0918.09 +65/-65 8 33 X 62.75 CGI110 SH X 17-1018.08 DP +75/-75 9 33 X 62.75 CGI110 SH X 17-1018.08 DP +75/-75 10 56.5 X 48.5 CGIC FIXED X FL 25883.1 +70/-80 11 108.75 X60.5 CGIC FIXED X FL 25883.1 +70/-80 12 72 X 79.5 PGT FIXED X 17-0420.12 +46.7/-60 13 186.125 X 80 PGT FIXED X 17-0420.12 +46.7/-60 14 72 X 79.5 PGT FIXED X 17-0420.12 +46.7/-60 15 110.25 X 61 CGIC FIXED X FL 25883.1 +70/-80 16 35 X 61 CGIC FIXED X FL 25883.1 +70/-80 17 73 X 61 CGIC FIXED X FL 25883.1 +70/-80 18 26.25 X 62.75 CGI110 SH X 17-1018.08 DP +75/-75 19 26.25 X 62.75 CGI110 SH X 17-1018.08 DP +75/-75 20 37 X 62.75 CGI110 SH X 17-1018.08 DP +75/-75 21 37 X 62.75 CGI110 SH X 17-1018.08 DP +75/-75 22 53 X 62.75 CGI110 SH X 17-1018.08 DP +75/-75 23 53 X 62.75 CGI110 SH X 17-1018.08 DP +75/-75 24 37 X 62.75 CGI110 SH X 17-1018.08 DP +75/-75 25 37 X 62.75 CGI110 SH X 17-1018.08 DP +75/-75 26 37 X 62.75 CGI110 SH X 17-1018.08 DP +75/-75 27 37 X 62.75 CGI110 SH X 17-1018.08 DP +75/-75 28 29 30 31 32 33 *Window Replacement using existing shutters to comply with impact protection will require the existing shutters to meet the requirements of the 2010 FBClResidential R301.2.1.2 TOTAL GLAZED OPENING AREA FOR 8TRUCTURE: 8.F. PERCENTAGE OF NEW GLAZED AREA: (TOTAL INSTALLED GLAZED AREA DIVIDED BY TOTAL GLAZED OPENINGS FOR STRUCTURE) NOTE: The replacement of more than 25 of the aggregate area of exterior glazing (windows & doors) in one & two family dwellings within a 12 month period will require impact protection on all proposed glazed opening replacement (approved shutters or impact resistant glazing) as per 20 I 0 FBCI EXISTING BUILDING 606.4. ** TYPE WINDOWS SH – SINGLE HUNG AWN – AWNING SL – SLIDING DR – DOUBLE HUNG CAS – CASEMENT FIX – FIXED PETERSON 13409 NW WAX MYRTLE WAY PALM CITY Building height Zone 4 I Area 15 20 25 30 35 40 45 50 55 60 10 pos 37.9 40.4 42.3 43.8 45.4 46.7 47.9 48.9 49.8 50.7 neg 41.1 43.8 45.9 47.5 49.2 50.6 52 53 54 55 20 pos 36.3 38.7 40.5 42 43.5 44.7 45.9 46.8 47.7 48.6 neg 39.4 42 44 45.6 47.2 48.5 49.8 50.8 51.8 52.8 50 pos 35.4 37.7 39.4 40.9 42.4 43.5 . 44.7 45.6 46.5 47.3 neg 37.1 39.6 41.4 42.9 44.5 45.7 46.9 47.8 48.7 49.7 \100 pas 32.2 34.4 36 37.3 38.6 39.7 40.8 41.6 42.4 43.2 neg 35.4 37.8 39.5 41 42.5 43.6 44.8 45.7 46.6 47.4 500 pas 28.2 30.1 31.5 32.7 33.8 34.8 35.7 36.4 37.1 37.8 neg 31.4 33.5 35.1 36.4 37.7 38.7 40.5 39.7 41.3 42.1 Building height End zone 5 15 20 25 30 35 40 45 50 55 60 10 pas. 37.9 40.4 42.3 43.8 45.4 46.7 47.9 48.9 49.8 50.7 neg 50.7 54.1 56.6 58.7 60.8 62.5 64.2 65.4 66.7 67.9 20 pos 36.3 38.7 40.5 42 43.5 44.7 45.9 46.8 47.7 48.6 neg 47.3 50.5 52.8 54.8 56.7 58.3 59.8 61 62.2 63.4 50 pos 35.4 37.7 I 39.4 40.9 42.4 43.5 44.7 45.6 46.5 47.3 neg 42.8 45.6 47.7 49.5 51.2 52.7 54.1 55.1 56.2 57.3 100 pos 32.2 34.4 36 37.3 38.6 39.7 40.8 41.6 42.4 43.2 neg 39.4 42 44 45.6 47.2 48.5 49.8 50.8 51.8 52.8 500 pos 28.2 30.1 31.5 32.7 33.8 34.8 35.7 36.4 37.1 37.8 neg 31.4 33.5 35.1 36.4 37.7 38.7 39.7 40.5 41.3 I 42.1 Wind design Pressure Chart for structures subject to Florida Residential Code 170 mph exposure C Wall component and Cladding pressures from Table R302.2(2) modified by adjustment factors from R301.1(3). Converted to Vasd according to R302.1.2.1.1 PETERSON 13409 NW WAX MYRTLE WAY PALM CITY