Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Product Spec
Daikin North America LLC San Felipe, Suite 500 Houston, TX 77056 (Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date: August 2018 Page 1 of 4 Performance Cooling (Btu/hr) Rated 8,800 Sensible @ AHRI 7,677 Operating Range 50°F – 115°F Rated Cooling Conditions:Indoor: 80°F DB/67°F WB Outdoor: 95°F DB/75°F WB Heating (Btu/hr) 1: @ 47° Rated 9,400 2: @ 17° Rated 5,800 3: @ 5° 4,603 Operating Range 5°F – 65°F 1: Rated Heating Conditions:Indoor: 70°F DB/60°F WB Outdoor: 47°F DB/43°F WB 2: Rated Heating Conditions:Indoor: 70°F DB/60°F WB Outdoor: 17°F DB/15°F WB 3: Heating Conditions:Indoor: 69.8°FDB Outdoor: 5°F WB Submittal Data Sheet FTXB09AXVJU / RXB09AXVJU 0.75-Ton Wall Mounted Heat Pump System Efficiency Cooling Heating SEER 17 HSPF 9 EER 11 COP 3.56 Electrical 208/60/1 230/60/1 System MCA 6.95 6.95 System MFA 15 15 Compressor RLA 6.75 6.75 Outdoor fan motor FLA .19 .19 Outdoor fan motor W 41 41 Indoor fan motor FLA .20 .20 Indoor fan motor W 18 18 MFA: Max. fuse amps MCA: Min. circuit amps (A) FLA: Full load amps (A) RLA: Rated load amps (A) W: Fan motor rated output (W) Piping Liquid (in) 1/4 Gas (in) 3/8 Drain (in) 3/4 Max. Interunit Piping Length (ft) 65.625 Max. Interunit Height Difference (ft) 32.8 Chargeless (ft) 24.6 Additional Charge of Refrigerant (oz/ft) .21 Indoor Specifications Airflow Rate (cfm) Cooling Heating H M H M 330 272 330 272 L L 215 215 Sound (dBA) H / M / L / SL 42 / 35 / 30 42 / 35 / 30 Dimensions (H × W × D) (in) 11-11/16 × 35-1/16 × 8-1/4 Weight (Lbs) 20 Outdoor Specifications Compressor Hermetically Sealed Swing Type Refrigerant R-410A Factory Charge (Lbs) 1.625 Refrigerant Oil PVE (FVC50K) Airflow Rate (cfm) Cooling Heating H 900 H 900 Sound Pressure Level (dBA) 46 Dimensions (H × W × D) (in) 21-5/8 × 25-15/16 × 10-3/4 Weight (Lbs) 53 Job Name: Tag# Complete warranty details available from your local dealer or at www.daikincomfort.com. To receive the 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Quebec. If product is installed in a commercial application, limited warranty period is 5 years. Daikin North America LLC San Felipe, Suite 500 Houston, TX 77056 (Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date: August 2018 Page 2 of 4 FTXB09AXVJU Dimensional Data Daikin North America LLC San Felipe, Suite 500 Houston, TX 77056 (Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date: August 2018 Page 3 of 4 RXB09AXVJU Dimensional Data Daikin North America LLC San Felipe, Suite 500 Houston, TX 77056 (Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date: August 2018 Page 4 of 4 Remark: AFR: Air flow rate (CFM) EWB: Entering Wet Bulb Temp. (°F) EDB: Entering Dry Bulb Temp. (°F) TC: Total Cooling Capacity (Btu/h) SC: Sensible Cooling Capacity (Btu/h) PI: Power Input (kW) Notes: 1.Ratings shown are net capacities. 2. Shows nominal capacities. 3.Direct interpolation is permissible. Do not extrapolate. Cooling Mode TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI 69.2°F 8294 6258 0.61 8001 6094 0.66 7703 5930 0.71 7394 5760 0.77 6790 5360 0.84 6269 5042 0.92 74.6°F 8305 7493 0.61 8010 7322 0.66 7714 7151 0.71 7405 6974 0.77 6803 6513 0.84 6293 6145 0.92 80.0°F 8371 8371 0.61 8092 8092 0.66 7808 7808 0.71 7514 7514 0.77 6933 6933 0.84 6450 6450 0.93 85.4°F 8628 8628 0.61 8381 8381 0.66 8127 8127 0.72 7865 7865 0.78 7290 7290 0.85 6821 6821 0.94 74.6°F 9149 5842 0.62 8828 5694 0.67 8504 5543 0.72 8167 5386 0.79 7506 5017 0.85 6939 4724 0.94 80.0°F 9155 6684 0.62 8832 6534 0.67 8509 6384 0.72 8174 6230 0.79 7513 5827 0.85 6948 5520 0.94 85.4°F 9169 8249 0.62 8852 8073 0.67 8539 7894 0.72 8216 7704 0.79 7564 7205 0.85 7018 6818 0.94 90.8°F 9278 9278 0.62 8976 8976 0.67 8685 8685 0.73 8388 8388 0.79 7761 7761 0.86 7256 7256 0.95 80.0°F 10065 5718 0.63 9717 5580 0.68 9362 5440 0.74 8997 5291 0.80 8273 4930 0.87 7658 4648 0.96 85.4°F 10068 6969 0.63 9720 6820 0.68 9364 6665 0.74 8998 6507 0.80 8276 6091 0.87 7661 5776 0.96 90.8°F 10074 8139 0.63 9725 7984 0.68 9371 7825 0.74 9005 7664 0.80 8286 7194 0.87 7680 6834 0.96 96.2°F 10106 9229 0.63 9773 9044 0.68 9433 8856 0.74 9090 8661 0.80 8383 8120 0.87 7794 7703 0.96 69.2°F 8632 6529 0.61 8320 6361 0.66 8005 6192 0.72 7678 6017 0.78 7045 5603 0.84 6499 5273 0.93 74.6°F 8658 7925 0.61 8347 7740 0.66 8034 7555 0.72 7710 7365 0.78 7083 6871 0.85 6547 6485 0.93 80.0°F 8762 8762 0.62 8468 8468 0.67 8176 8176 0.72 7882 7882 0.78 7277 7277 0.85 6779 6779 0.94 85.4°F 9128 9128 0.62 8863 8863 0.67 8593 8593 0.73 8314 8314 0.79 7703 7703 0.86 7200 7200 0.95 74.6°F 9510 6177 0.62 9171 6022 0.67 8827 5865 0.73 8472 5704 0.79 7780 5315 0.86 7187 5010 0.95 80.0°F 9526 7115 0.62 9186 6958 0.67 8843 6800 0.73 8488 6639 0.79 7799 6206 0.86 7210 5876 0.95 85.4°F 9572 8777 0.62 9239 8587 0.68 8908 8395 0.73 8567 8190 0.79 7888 7657 0.86 7319 7234 0.95 90.8°F 9731 9731 0.63 9435 9435 0.68 9134 9134 0.74 8831 8831 0.80 8180 8180 0.87 7648 7648 0.96 80.0°F 10449 6048 0.63 10081 5906 0.69 9706 5757 0.75 9320 5601 0.81 8565 5224 0.88 7922 4929 0.97 85.4°F 10462 7421 0.63 10093 7268 0.69 9717 7105 0.75 9331 6940 0.81 8576 6500 0.88 7933 6168 0.97 90.8°F 10480 8696 0.64 10116 8530 0.69 9745 8356 0.75 9361 8178 0.81 8612 7671 0.88 7983 7283 0.97 96.2°F 10545 9831 0.64 10205 9645 0.69 9848 9444 0.75 9490 9224 0.81 8755 8632 0.88 8163 8143 0.97 69.2°F 8952 6814 0.62 8624 6641 0.67 8293 6466 0.72 7949 6285 0.78 7291 5854 0.85 6721 5509 0.94 74.6°F 8999 8280 0.62 8672 8084 0.67 8346 7886 0.73 8009 7679 0.79 7355 7166 0.85 6795 6756 0.94 80.0°F 9144 9144 0.62 8845 8845 0.67 8546 8546 0.73 8240 8240 0.79 7614 7614 0.86 7096 7096 0.95 85.4°F 9602 9602 0.63 9321 9321 0.68 9034 9034 0.74 8737 8737 0.80 8090 8090 0.87 7555 7555 0.96 74.6°F 9853 6536 0.63 9497 6375 0.68 9136 6211 0.74 8764 6043 0.80 8043 5634 0.87 7426 5314 0.95 80.0°F 9882 7562 0.63 9527 7389 0.68 9169 7216 0.74 8800 7040 0.80 8080 6584 0.87 7467 6229 0.96 85.4°F 9964 9306 0.63 9612 9103 0.68 9267 8895 0.74 8912 8672 0.80 8206 8100 0.87 7617 7617 0.96 90.8°F 10180 10180 0.63 9882 9882 0.69 9578 9578 0.74 9262 9262 0.81 8580 8580 0.88 8025 8025 0.97 80.0°F 10812 6394 0.64 10428 6254 0.69 10036 6097 0.75 9632 5937 0.82 8847 5540 0.88 8177 5231 0.97 85.4°F 10835 7883 0.64 10449 7734 0.69 10056 7565 0.75 9652 7393 0.82 8868 6923 0.88 8202 6563 0.97 90.8°F 10872 9238 0.64 10496 9077 0.69 10110 8886 0.75 9713 8690 0.82 8936 8145 0.89 8278 7730 0.98 96.2°F 10969 10431 0.64 10626 10241 0.70 10258 10017 0.76 9889 9768 0.82 9137 9111 0.89 8524 8524 0.98 330 61.6°F 67.0°F 72.4°F 215 61.6°F 67.0°F 72.4°F 272 61.6°F 67.0°F 72.4°F AFR (CFM)EWB EDB Outdoor temperature 66.2°F 77.0°F 86.0°F 95.0°F 104.0°F 114.8°F Heating Mode TC PI TC PI TC PI TC PI TC PI TC PI 60.8 4716 0.56 5851 0.60 6985 0.63 8136 0.67 9497 0.72 10405 0.75 64.4 4668 0.58 5802 0.62 6953 0.66 8087 0.70 9449 0.75 10356 0.78 68.0 4619 0.61 5753 0.65 6904 0.69 8039 0.73 9400 0.77 10308 0.81 69.8 4603 0.62 5737 0.66 6872 0.70 8006 0.74 9384 0.79 10291 0.82 71.6 4570 0.64 5721 0.68 6856 0.71 7990 0.76 9351 0.80 10259 0.83 75.2 4522 0.67 5672 0.71 6807 0.75 7941 0.78 9303 0.83 10210 0.86 Indoor DB°F Outdoor WB°F 5.0 14.0 23.0 32.0 42.8 50.0 FTKB09AXVJU / RKB09AXVJU Performance Tables