Loading...
HomeMy WebLinkAboutBuilding permit ApplicationSUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION: Not Applicable I MORTGAGE COMPANY: _ Not Applicable Name: Address: Address: City: State: City: State: Zip: Phone Zip: Phone: FEE SIMPLE TITLE HOLDER: _ Not Applicable Name: Address: City: Zip: Phone: BONDING COMPANY: _Not Applicable Address: Em OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated. I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE.OF COMMENCEMENT." Signatu o wner/ Lessee ontr for asg. ent ti r Owner Signature of Contractor/License old s� STATE OF FLORIDA STATE OF FLORIDA COUNTY OF PALM BEACH COUNTY OF PAI.MBEACH The forgoing instrument was acknowledged before me The forgoing instrument was acknowledged before me this 20 day of MAY 20_ by this 2) day of MAY 20_ by RICHARD BASSOFF RICHARD BASSOFF Name of person making statement. Name of person making statement. Personally Known x OR Produced Identification Personally Known x OR Produced Identification Type of Identification Type of Identification Produced �) ! It) &(C , I%, �( Produced (Signature of Notary lic- State of Florida j u'yr� NICOLE gULLIVAN Commission No. `AR, "K'i r�T� OMMISSI I (Signature of Nota Commission No. ' ; •' NICOLE M SULLIVAN • c My COMMIS4Iwa0 GG043125 # GG043125 -111 , X EXPIRES October 30. 2020 EXPIRES October 3O, 2020 REVIEWS SUPERVISOR PLANS VEGETATION MANGROVE FRONT ZONING SEA TURTLE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE RECEIVED DATE COMPLETED Rev. 21 // 19 All APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: MAY 20,2019 Permit Number. Building Permit Application Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1S78 Commercial Residential X PERMITTYPE: PLUMBING PROPOSED IMPROVEMENT LOCATION: Address: 3009 FIVE IRON DRIVE, PORT ST LUCIE, FL 34952 Property Tax ID #: 3425-707-0086-000-0 Site Plan Name: Project Name: WATER HEATER I DETAILED DESCRIPTION OF WORK: 40-GALLON ELECTRIC WATER HEATER REPLACEMENT CONSTRUCTION INFORMATION: AdEkk Additional work to be performed under this permit —check all that apply: _Mechanical _Gas Tank _Gas Piping _Shutters _ Electric _ Plumbing _ Sprinklers Total Sq. Ft of Construction: _ Cost of Construction: $ 1,124.00 _ Generator Sq. Ft. of First Floor: Lot No. Block No. Windows/Doors Roof Pitch Utilities: _ Sewer _ Septic Building Height: OWNER/LESSEE: CONTRACTOR: Name Linda M Ricioppo Name: RICHARD BASSOFF Address:3009 FIVE IRON DRIVE Company: ADMIRAL PLUMBING SERVICES, LLC City: PORT ST LUCIE FL State: _ Zip Code: 34952 Fax: Phone No. 7724467709 Address: 2895 JUPITER PARK DR STE 700 City: JUPITER State: FL Zip Code: 33458 Fax: Phone No 561-746-1180 E-Mail: Fill in fee simple Title Holder on next page ( if different from the Owner listed above) E-Mail PERTMITTING@THEADMIRALPLUMBER.COM State or County License CFC1426115 If value of construction is $2500 or more, a RECORDED Notice of Commencement is required. If value of HVAC is $7,500 or more, a RECORDED Notice of Commencement is required. a The new degree of comfort' Professional Classic® electric water heaters are engineered for longer life - resistored heating elements and premium grade anode rod Efficiency • .92 - .93 UEF • Isolated tank design reduces conductive heat loss • Resistored copper upper element and resistored Lifeguard' stainless steel lower element to prolong anode rod and tank life Performance • FHR: 43 - 67 gallons, based on gallon capacity • Recovery: 21 GPH at a 90' F rise System Sentinel (Available on selected models) • Exclusive diagnostic system with glowing LEDs that verify heating element operation. LEDs pin point the exact location of functioning or non- functioning heating elements Longer Life • Premium grade anode rod provides long-lasting tank protection Features • Electric junction box located above heating elements for easy installation • Over -temperature protector cuts off power in excess temperature situations • Automatic thermostat keeps water at desired temperature Plus... • EverKleen" self cleaning device fights harmful sediment build-up with a high -velocity spiraling water stream — helps operating efficiency by saving energy, money and improving tank life • Enhanced -flow brass drain valve • Temperature and pressure relief valve included • HUD certified for manufactured housing and modular construction • Low lead compliant Warranty • 6-Year limited tank and parts warranty` • With Protection Plus' the 6-year limited tank warranty becomes 10-year 'See Residential Warranty Certificate for complete information Units meet or exceed ANSI requirements and have been tested according to the AHRI Operations Manual and D.O.E. procedures. Units meet or exceed the energy efficiency requirements of NAECA, ASHRAE standard 90, ICC Code and all state energy efficiency performance criteria. Residential Electric . w Water Professional Classic Water Heaters Professional Classic 19.9 to 55-Gallon Capacities 240 Volt AC/Single Phase Double and Single Element Models Electric See specifications chart on back. PRINTED IN U.S.A. USIt r \YP FORM NO. PROE AN N Rev. 6 Residential Electric Water Professional Classic Water Heaters Professional Classic® Specifications DESCRIPTION FEATURES ROUGHING IN DIMENSIONS ISHOWN IN INCHES) ENERGY INFO. T Y P E NOMINAL GALLON CAPACITY RINGED GALLON CAPACITY MOOEL NUMBER UEF NRSTHWR RATING "A. EF FRITHOUR RATNG GPM. REcoV IN O.P.N. WFR14E TANK HEM" A HIROWTO WATER CONK a OMMEFER c APPROX. sHIPYrt, ILM ENERGY FAVOR UNIFORM ENERGY FACTOR NER Tell 30 27 PROE30 T2 RH951 48 48 21 47-1l2 50-3/8 19-1/4 92 0.95 0.92 Tall 40 36 PROE40 T2 AH951 55 57 21 60-3/4 63-5/8 /9-1/4 109 0.95 am Tall 50 45 PROESO T2 81-1951 63 67 21 58-5/8 61-5/8 20-1/4 121 0.95 0.93 Tall 55 55 PRO05 T2 RH941 67 71 21 57 59-3/4 22-1/4 128 0.94 022 Med. 30 27 PROE30 M2 RH951 45 44 21 37-1/2 40-1/2 20-1/4 92 0.95 0.92 Mad. 40 36 PROE40 M2 RH951 54 55 21 48-1/4 50-IM 20.1/4 106 0.95 093 Mad. 50 1 45 1 PROESO M2 RH951 62 65 21 48 50-1/2 1 23 132 0.95 093 Short 19.9 - PROE20 S2 RH 21 31-142 31-112 17 62 Short 28 25 PROE28 S2 RH95 43 42 21 30 31-1/8 23 95 0.95 0.92 3Mrt 30 27 PROE30 S2 RH95 B-° 43 42 21 30-1/8 32 19-3/4 95 0.95 0.92 Short 36 33 PROE36 S2 RH95 46 45 21 31-1/2 33 24-1/4 118 0.95 0.92 Short 38 35 PROE38 S2 RH95 B" 54 55 21 31-1/2 M-5/8 23 108 0.95 0.93 Short 47 A3 PROE47 S2 RH95 S" 54 55 21 32 34 26-1/4 149 0.95 0.0 Uniform Energy Factor, Energy Facto, anti rated gallon capeay based on Department of Energy (DIM rsq.iuments. t System Sentinel optional. Add EC1 to the and of the model number. System Sentinel not available on single 6 element models, avaiible on dual element models only. System Sentinel not available in excess of 5 kW on 208 V models. YAGer neater hmvvIO,s pror to ,nsiali remniion blanket Ilatl wit h water healer. • Heaters funiShed wnh starx)bd 240 wit AC, sbgle phase mn-smultansous wing, ant w 4500 11 upper and lower heats, elements. HOT • N heating elements of different wattages than those shown are d imandsd quire by zone requirements, they must be WATER s,scRaally requested. CONNECTION • Sngle element modes avalhbe On special Omer (6003W max4. &MIRUle'I' lw'2' n ncoini member. • Spedal Wring Options- A knited number of special wing optans are availame. Consuft factory for Once shot availably. RELIEF VALVE • AA nodes equppao with heat traps. CONNECTION Recovery = wanage/2.42 x temp. rise °F. Fsample: 4500W =21 GPH C- 2.42 x 90' r DIAMETER Recovery cakulapons used! are based on 45M waft eanvo is used m rtal-smulmrleous operation. T A O B WATER CONNECTIONS ALL 314v N.P.T. In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Water Heating • 1115 Northmeadow Parkway, Suite 100 Roswell, Georgia 30076 • www.rheem.com PRINTED IN USA WI WP FORM NO. PROE RH N R..6 Admiral Plumbing Services, LLC Invoice 24093779 `x PLUMBING SERVICES 2895 Jupiter Park DR#700 Invoice Date 5/4/2019 A Service FIL Experts Company Jupiter, 566-1180 Terms COD License: CFC FC 1426115 26 Completed Date 5/4/2019 Customer PO Billing Address Job Address LINDA RICI LINDA RICI 3009 5 Iron Drive 3009 5 Iron Drive Port St. Lucie, FL 34952 USA Port St. Lucie, FL 34952 USA Description of Work Customer had 40 gal med heater leaking in storage closet replace heater with permit there electrical company did electric update tested there was still water on floor from old heater Task# Description Quantity Your Price Your Total T61190 LOWBOY 40 GALLON ELECTRIC WATER HEATER -PLUS PERMIT AND UPGRADES 1.00 $899.00 $899.00 A99536 WATER HEATER PERMIT 1.00 $225.00 $225.00 Paid On Type Memo Amount 5/4/2019 Check $1,124.00 Sub -Total $1,124.00 Tax $0.00 Total Due $1,124.00 Payment $1,124.00 Balance Due $0.00 Terms: ALL ESTIMATES ARE GOOD FOR 30 DAYS. All material is guaranteed to be as specified. All work is to be completed in a professional manner according to standard practices. Any alteration or deviation from above specifications involving extra costs will be executed only upon written orders and will become an extra charge over and above the estimate. All agreements contingent upon delays, beyond our control. All payments are due upon completion of installation. All payments not received upon completion are subject to 1 1/2%service charge per month, or the maximum rate permitted by law, whichever is less. In the event of non-payment, all costs incidental to collection, including without limitation reasonable attorney's fees shall be added to the unpaid balance. "CANCELLATION OF WORK AFTER DEPOSIT IS PAID: In the event ajob is cancelled after the deposit is paid, a refund will be given minus any permit (if applicable) and administrative fees that were paid by Admiral Plumbing. PLEASE MAIL ALL PAYMENTS TO: 2895 JUPITER PARK DR #700 JUPITER, FL 33458 (561)746-1180 I hereby agree to have Admiral Plumbing complete the work described for the proposed price regardless of the time it takes to complete the work. 5/4/2019 1 hereby acknowledge the satisfactory completion of the above described work.