HomeMy WebLinkAboutDrawing Opening Size
(l'V x H) I �,
1. 18-0918.04 36 x 36 _ 4
2 (DOUBLE HUNG)
0918'04• 25 x 24
(DOUBLE HUNG)
1 16-0918.04 36 x 37
(DOUBLE HUNG) 3 4 60"
A. 18-0918.04 36 x 37 @V=Z
,(DOUBLE HUNG) - 315. 18-0911 M. r 36 x37
(CASEMENT)
6. 18-0911.06 36 x'37 KITCHEN
(CASEMENT) BED 1 w 5
7. 18-0918.04 36 x 37
(DOUBLE HUNG) LLJ
-
- 8:-18-0918.04 55 x61 ,, 24"
(DOUBLE HUNG)
9.c 18-0918.04- 55 x 61'
(DOUBLE HUNG) Tu
.r
c
M
2 BATH 1 .
ai
N
35 d m
- d.. 4 N
U. N N
d
O d, x
C d .t' W
.. Ina IL ty
N
cn
LIVING BED 2 s w �
1 APT. 9 s 7 W J Q u
F D 60" w
60" N O� c)
J
LV � Z
NU)
- O
rZ
' COPYPJGNi E•TENPEST.COY
SCALE:
NOT TO SCALE
DATE:
- May 17,2019
PAGE DESCRIPTION:
Site Plan
PAGE: OF+
1
i
i
i
500-SW 12th Ave
STMR . .- Deerfield Beach,FL 33442
Ph 561-922-6747 WIND
ows
i
Fax.561=292-3562
Property Information Building Information
Owner: SHEILA SOLER Wind Zone: 170 MPH.
Address: 410 WILLOWS AVE. Exposure Category: C
PORT SAINT LUCIE,FL 34952 Minimum Building Dimension: 35 ft.
Mean Roof Height: 12 ft.
Risk Category: II
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(ps
1 Int 36 36 7 37.8 -41.0
2 End 25 24 7 37.8 -50.6
3 Int 36 37 7 37.8 -41.0
4 Int 36 37 7 37.8 -41.0
5 End 36 37 _ 7 37.8 -50.6 _
6 Int 36 _ 37 7 37.8 -41.0
7-- Int-- 36 37 —"7 37.8 --- -41.0
8 Int 55 61 7 35.7 -38.9
9 Int 55 61 7 35.7 -38.9
Prepared in accordance with:ASCE 7-10,Chapter 30.Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code,
Page 1 of I
410 WILLOW AVE. SHEILA A. SOLER- 8613
A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET
Definition of Comer Zone-10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft.
PRODUCT APPROVAL REQUIRED OPENING MAXIMU MULTIPLE
OPENING (Location) IS THIS A ROUGH GLAZING PRODUCT APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW ARE
LOCATION Corner Zone WINDOW TYPE NUMBER
TESTED OPENING SHUTTERS
NUMBER or Interior OR DOOR NUMBER (+)PSF (-)PSF (+)PSF (-)PSF DIMENSIONS MULLION REQ Y/N
SIZE REQ Y/N/NA
1 Int Window 7/8"LamiIG 18-0918.04 55 55 37.8 -41.0 5307 3606 No No
2 End Window 7/8"LamilG 18-0918.04 55 55 37.8 -50.6 5307 25x24 No No
3 Int Window 7/8"LamilG 18-0918.04 55 55 37.8 -41.0 5307 3607 No No
4 Int Window 7/8"LamilG 18-0918.04 55 55 37.8 -41.0 5307 3607 No No
5 End Window 7/8"LamilG 1 18-0911.06 55 55 37.8 -50.6 36x68 j 3607 No No
6 Int Window 7/8"LamiIG 18-0911.06 55 55 37.8 -41.0 36x68 36x37 No No
7 Int Window 7/8"LamilG 18-0918.04 55 55 37.8 -41.0 5307 3607 No No
8 Int Window 7/8"LamilG 18-0918.04 55 55 35.7 -38.9 5307 55x61 YES No
9 Int Window 718"LamilG 18-0918.04 55 55 35.7 -38.9 5307 55x61 YES No