Loading...
HomeMy WebLinkAboutDrawing Opening Size (l'V x H) I �, 1. 18-0918.04 36 x 36 _ 4 2 (DOUBLE HUNG) 0918'04• 25 x 24 (DOUBLE HUNG) 1 16-0918.04 36 x 37 (DOUBLE HUNG) 3 4 60" A. 18-0918.04 36 x 37 @V=Z ,(DOUBLE HUNG) - 315. 18-0911 M. r 36 x37 (CASEMENT) 6. 18-0911.06 36 x'37 KITCHEN (CASEMENT) BED 1 w 5 7. 18-0918.04 36 x 37 (DOUBLE HUNG) LLJ - - 8:-18-0918.04 55 x61 ,, 24" (DOUBLE HUNG) 9.c 18-0918.04- 55 x 61' (DOUBLE HUNG) Tu .r c M 2 BATH 1 . ai N 35 d m - d.. 4 N U. N N d O d, x C d .t' W .. Ina IL ty N cn LIVING BED 2 s w � 1 APT. 9 s 7 W J Q u F D 60" w 60" N O� c) J LV � Z NU) - O rZ ' COPYPJGNi E•TENPEST.COY SCALE: NOT TO SCALE DATE: - May 17,2019 PAGE DESCRIPTION: Site Plan PAGE: OF+ 1 i i i 500-SW 12th Ave STMR . .- Deerfield Beach,FL 33442 Ph 561-922-6747 WIND ows i Fax.561=292-3562 Property Information Building Information Owner: SHEILA SOLER Wind Zone: 170 MPH. Address: 410 WILLOWS AVE. Exposure Category: C PORT SAINT LUCIE,FL 34952 Minimum Building Dimension: 35 ft. Mean Roof Height: 12 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(ps 1 Int 36 36 7 37.8 -41.0 2 End 25 24 7 37.8 -50.6 3 Int 36 37 7 37.8 -41.0 4 Int 36 37 7 37.8 -41.0 5 End 36 37 _ 7 37.8 -50.6 _ 6 Int 36 _ 37 7 37.8 -41.0 7-- Int-- 36 37 —"7 37.8 --- -41.0 8 Int 55 61 7 35.7 -38.9 9 Int 55 61 7 35.7 -38.9 Prepared in accordance with:ASCE 7-10,Chapter 30.Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code, Page 1 of I 410 WILLOW AVE. SHEILA A. SOLER- 8613 A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET Definition of Comer Zone-10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft. PRODUCT APPROVAL REQUIRED OPENING MAXIMU MULTIPLE OPENING (Location) IS THIS A ROUGH GLAZING PRODUCT APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW ARE LOCATION Corner Zone WINDOW TYPE NUMBER TESTED OPENING SHUTTERS NUMBER or Interior OR DOOR NUMBER (+)PSF (-)PSF (+)PSF (-)PSF DIMENSIONS MULLION REQ Y/N SIZE REQ Y/N/NA 1 Int Window 7/8"LamiIG 18-0918.04 55 55 37.8 -41.0 5307 3606 No No 2 End Window 7/8"LamilG 18-0918.04 55 55 37.8 -50.6 5307 25x24 No No 3 Int Window 7/8"LamilG 18-0918.04 55 55 37.8 -41.0 5307 3607 No No 4 Int Window 7/8"LamilG 18-0918.04 55 55 37.8 -41.0 5307 3607 No No 5 End Window 7/8"LamilG 1 18-0911.06 55 55 37.8 -50.6 36x68 j 3607 No No 6 Int Window 7/8"LamiIG 18-0911.06 55 55 37.8 -41.0 36x68 36x37 No No 7 Int Window 7/8"LamilG 18-0918.04 55 55 37.8 -41.0 5307 3607 No No 8 Int Window 7/8"LamilG 18-0918.04 55 55 35.7 -38.9 5307 55x61 YES No 9 Int Window 718"LamilG 18-0918.04 55 55 35.7 -38.9 5307 55x61 YES No