Loading...
HomeMy WebLinkAboutDrawing Opening; (wX x) 1. FL16177-.1 - 25�'x36 rn .(SINGLE HUNG)'' `; c '2. FL1.6177.1 35x36 (SINGLE HUNG)_ Q p7 E cu I FL16736A 72 z61 LLJ N CL (HORIZONTAL-SLIDER) 4. FL.16177.1 36 z'49 > 41 ' 'O (SINGLE HUNG)-' W o a - '+ 5: FL16177.1 36 x 49 L J i- U (SINGLE HUNG)' N 6. FL13010.435 x:16 3 (FIXED SHAPE) J n 7 FL16177.1 24 x 60 ~ p (SINGLE HUNG) 58 j (DLO '8 FL16177.1 50x60 = 0 E -m (SINGLEHUN(j)= O 't N 9 (SING7.1 24 x 60 „ (SINGLE HUNG} (SI2 3 501, cj) aU� ® 0 um GIS KITCHEN BED 1 _ BATH 1 36' °CLO 7 M } LL BED 2 Q LLI LIVING 5 4 w g 7 8 co O LL . COPYftiGM E•TENPEST.CON .. ,, :«� .. • SCALE: NOT TO SCALE DATE: May 14,2019 PAGE DESCRIPTION: Site Plan PAGE: OF1 P R ALvi- E E "Building Our Quality Rppd ation One.Customer At.A Time" SCC131150472 Property Information Building Information Owner: STACY MORAN,JR Wind Zone: 170 MPH. Address: 6210 DRAWDY PKWY Exposure Category: C FORT PIERCE,FL 34951 Minimum Building Dimension: 36 ft, j Mean Roof Height: 12 ft. i Risk Category: I1 i Design Pressure Calculations Opening Location i, Device Device _Device 'I Max Positive Max Negative Number Zone Width in 1 Height to Elevation ft i' Pressure s - ..�� .......— ...... ( � __�l. — g ( _�_ 1� ( � ......_ (1? !I Pressure Pressure(psf) ; — ............. 1 Int 25 36 7 37.8 -41.0 - -- ---.--. ................. ----.. ..... _._.__.— _. ---- _.__.---- 2 Int 35 36 7 37.8 41.0 --- . - --- _.... ----.. - -- -- - 3 Int 72 61 7 35.1 38.3 _._------------- ----- 4 End 36 49 7 37.3 -49.6 5 Int 36 49 7 37.3 40.5 ---_ _.._........._.__ .........__......._...--- ___....... --- -- -- -----__ - ............... _...--- 6 End 35 16 7 37.8 -50.6 --.---. ----------- -__.._._._ _.__._.. _ - ....... ---- ..... . - _ ........._. - 7 Int 24 60 7 37.8 -41.0 --__....__....-- -_._.._..._......__.. _—...._.........._._..---- ---...............-- ------- - - _..... --- --. 8 int 50 60 7 36.0 -39.2 ... ..........------._... - . _.................... ..._ _ :: ----_. ...........- ---- 9 Int 24 60 7 37.8 41.0 =RECEIVEL)ST. FILE Prepared in accordance with:ASCE 7-10,Chapter 30. if'ind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page IofI A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET , Definition of Corner Zone-10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft. PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE OPENING (Location) IS THIS A GLAZING PRODUCT APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW ARE LOCATION Corner Zone WINDOW TYPE ACCEPTANCE TESTED OPENING SHUTTERS NUMBER or Interior OR DOOR NUMBER (+)PSF (-)PSF (+)PSF (-)PSF DIMENSIONS MULLION REQ Y/N SIZE REQ YIN/NA 1 Int Window 7/8"Lan-" FL16177.1 70 70 37.8 -41.0 52x62 25x36 No No 2 Int Window 7/8"Lam' FL16177.1 70 70 37.8 -41..0 52x62 3506 No No 3 Int Window 7/9"La°"I(` FL16736.1 60 60 35..1 -38.3 74x63 72x.61. No No 4 End Window 7/8"Lam' FL16177.1 70 70 37.3 -49.6 52x62 36x49 YES No 5 Int Window 7/8"Lami FL16177.1 70 70 37.3 1 -40.5 52x62 36x49 YES No 6' End Window VLami10 FL13010.4 55 55 37.8 -50:6 48x72 35x16 YES No 7 Int Window 7/8"Lami FL16177.1 70 70 37.8 -41.0 52x62 24x.60 YES No 8 Int Window 7/8"Lami FL16177.1. 70 70 . 36.0 -39.2 52.x62 50x60 YES No 9 Int Window 7/8"Lami FL161.77.1 70 70 37.8 -41.0 52x62 24x.60 YES No rn LO a U u.j U u }- IMLEN !7