HomeMy WebLinkAboutBuilding Permit ApplicationAll APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date. 5-29-19 COUNTY Planning and Development5ervices Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 Permit Number: Building Permit Application PERMITTYPE:A/C CHANGE -OUT PROPOSED IMPROVEMENT LOCATION: Address: 6655 SPANISH LAKE BLVD Property Tax I D #: 1306-111-0001-000-0 Site Plan Name: Project Name: DETAILED DESCRIPTION OF WORK: Commercial Residential x Lot No. Block No. LIKE FOR LIKE REPLACEMENT OF (1) 3 TON GRANDAIRE PACKAGE UNIT, 14 SEER WITH 10 KW ELECTRIC HEAT. CONNECT TO EXISTING DUCTWORK, HIGH AND LOW VOLTAGE ELECTRIC. CONSTRUCTION INFORMATION: Additional work to be performed under this permit -check all that apply: Mechanical _ Gas Tank _ Gas Piping Shutters -Windows/Doors — Electric _ Plumbing _ Sprinklers _ Generator _ Roof Pitch Total Sq. Ft of Construction: Sq. Ft. of First Floor: Cost of Construction: $ 3,892.00 Utilities: _ Sewer _ Septic Building Height: OWNERAESSEE: CONTRACTOR: Name WYNNE BUILDING CORP. Name: JAMES F. GRIMES Address: 12804 SW 122ND AVE Company: GRIMES HEATING AND AIR CONDITIONING p Y� City: MIAMI State: r- L. Address: 3054 N US HWY 1 Zip Code: 33186 Fax: City: FORT PIERCE State: FL Phone No. 585-414-0627 Zip Code. 34946 Fax: 772-461-8722 E-Mail: NIA Phone No 772-461-8711 Fill in fee simple Title Holder on next page ( if different E-Mail ROBERTGRIMESAC@AOL.COM from the Owner listed above) State or County License 4426 If value of construction is 92snn nr moresa Rrrnnnrn -- _---- -. ••• -i vF -LFFFnIicimclent Is requires. If value of HVAC is $7,500 or more, a RECORDED Notice of Commencement is required. i Name: -- JMVL HppucaDle Address. City: Zip: Phone State: FEE SIMPLE TITLE HOLDER: Name: Not Applicable Address: City: Zip: Phone: O MORTGAGE { COMPANY: Name: _ _ Not Applicable Address: City: Zip: ---. Phone: State: BONDING COMPANY: Name: Not Applicable Address: City: Zip: --_. Phone: WNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build tstructure as indicated. which is in conflict with any applicable Home Owners Association rules, b structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. bylaws or and covenants that may restrict or pr h bit such In consideration of the granting of this requested permit, 1 do hereby agree that I will, in all respects, perform the work in accordance with the a plans, y approved cans the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your payingtwice improvements to your property. A Notice of Commencement must be recorded and posted onthe- for before the first inspection. If you intend to obtain financing, consult with lender or an attorney before Commencin work or recordin our Notice of Commencement_ Jobsite Y ore S' ature of Owner/ Lessee/Contractor as Agent for Owner STATE OF FLORIDA COUNTY OF ,S i -- The for oing instrument was acknowledged before me this day of 2011 by mofon making statement Personally Known OR Produced Identification Type of identification Produced ature of Notary Public- State of Commission N _ R0 �...�'' hfY C01�IF�ilSSiON n GG 089099 EXPIRES; Apn12, 202 REVIEWS FRONT ZONING St/PER� V p COUNTER REVIEW REVIEW ATr COMPLETED Rev.8/2/17 S' ature of Contractor/License Holder STATE OF FLORIDA COUNTYOF The for ping instrument was acknowledged before me this day of 7��220-a by yj 7 Name of person making statement Personally Known 'S— OR produced Identification Type of ldentification Produced {Signature of Notary Public- state of Florida Commission No. SUSAN h{S!pAkGP,O __ __ A1Y CG!�iP1155!ON � GG 089099 EXPIRES: A;r12. 2021 ' PLANS VEGETATION SEATURTLE REVIEW REVIEW MANGROVE REVIEW REVIEW cocaCertificate of Product Ratinas AHRI Certified Reference Number: 7492886 Date: 05-22-2019 Model Status : Active AHRI Type: SP-A Series: R410A AC SPP Outdoor Unit Brand Name: GRANDAIRE Outdoor Unit Model Number (Condenser or Single Package) : WJA436000K"OA Region : All (AK, AL, AR, AZ, CA, CO,.CT, DC, DE, FL, GA, HI, ID, IL, IA, IN, KS, KY, LA, MA, MD, ME, Ml, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, RI, SC, SD, TN, TX, UT, VA, VT, WA, WV, WI, WY, U.S. Territories) Region Note: Central air conditioners manufactured prior to January 1, 2015 are eligible to be installed in all regions until June 30, 2016. Beginning July 1, 2016 central air conditioners can only be installed in region(s) for which they meet the regional efficiency requirement. The manufacturer of this GRANDAIRE product is responsible for the rating of this system combination. Rated as follows in accordance with the latest edition of ANSI/AHRI 2101240 with Addenda 1 and 2, Performance Rating of Unitary Air -Conditioning & Air -Source Heat Pump Equipment and subject to rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (A2) - Single or High Stage (95F), btuh : 35000 SEER: 14.00 EER (A2) - Single or High Stage (95F) : 11.50 t"Active" Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale; OR new models that are being marketed but are not yet being produced."Production Stopped" Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still selling or offering for sale. Rahn , that are accom anied by WAS indicate an involunta re -rate. The new Qublished rating is shown along with the revious i.e. WAS ratin . DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed an this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.a h rid irecto ry.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. AM AIR-CONDITIONING, HEATING, CERTIFICATE VERIFICATION & REFRIGERATION INSTITUTE The information for the model cited on this Certificate can be verified at www.ahridirectory.org, click on "Verify Certificate' link and enter the AHRI Certified Reference Number and the date on which the certificate was issued, we make life better," which is listed above, and the Certificate No., which is listed at bottom right. ©2019Air-Conditioning, Heating, and Refrigeration Institute FC;ERTIF1CATE Nn_r 132030143633903612