HomeMy WebLinkAboutRevisions May 29,2019 10:06 AM To:17724621578 Page 2/5 From:XLR8 Roofing&Construction,LLC Fax:3212709369
OFFICE USE ONLY:
DATE FILED: 5/29/19 PERMIT# 1905-0277
REVISION FEE: (!o RECEIPT#
PLANNING & DEVELOPMENT SERVICES
BUILDING&CODE REGULATION DlVJ$I0,Nn,-7q
2300 VIRGINIA AVEN',
I.'lli�.%652 ", " r Al
FORT PIERCE,FL 34982
in.
(772)462-1553
cort
V\y APPLICATION FOR BUILDING PERPEFREYISIOI
PROJECT INFORMATION V
LOCATION/SITE ',8
ADDRESS:
14148 Cisne Cir, Fort Pierce
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
We used Rhino Underlayment instead of Grip Rite Underlayment
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: CCC1331278 ST. LUCIE CO CERT.
BUSINESS NAME: XLR8 Roofing&Construction,LLC
QUALIFIERS NAME: David Hambley
ADDRESS: 400 Specialty Pt
CITY: Sanford STATE: FL ZIP: 32771
PHONE(DAYTIME): 321-363-3871 FAX:
OWNERIBUILDER INFORMATION:
NAME: Kenneth Horn
ADDRESS:14148 Cisne Cir
CITY: Fort Pierce STATE: FL ZIP: 34951
PHONE(DAYTIME: 772-595-0301 FAX:
ARCHITECT/ENGINEER INFORMATION:
NAME:
ADDRESS:
CITY: STATE: ZIP:
PHONE (DAYTIME): FAX:
SLCCC.- 9123109
Revised 06/30/17
May 29,2019 10:06 AM To:17724621578 Page 3/5 From:XLR8 Roofing&Construction,LLC Fax:3212709369
J
EXTERIOR RESEARCH&DESIGN,LLC.
Certificate of Authorization#9503
� e� �Q� QE ��`a 353 CHRISTIAN STREET,UNIT#13
IN`�
F 'ERD �° Q OXFORD,CT 06478
Qe g� PHONE: (203)262-9245
FAX:(203)262-9243
EVALUATION REPORT
Interwrap,Inc. Evaluation Report 140510.02.12-113
32923 Mission Way FL15216-R3
Mission,BC V2V-6E4 Canada Date of Issuance:02/17/2012
(551)574-2939 Revision 3:10/10/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: RhinoRoof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity]ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 3.
Prepared by:
?d10 3etns:
'Z
Robert J.M.Nieminen,P.E. The facsimile seal appearing was authorized by Robert
Florida Registration No.59166, Florida DCA ANE1983 Nieminen,P.E.on 10/10/2017.This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity)ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E. does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
May 29,2019 10:06 AM To:17724621578 Page 415 From:XLR8 Roofing&Construction,LLC Fax:3212709369
. TKIN11Y ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: RhinoRoof Underlayments, as produced by Interwrap, Inc., has demonstrated compliance
with the following sections of the 6`h Edition (2017) Florida Building Code through testing in accordance with
applicable sections of the following Standards. Compliance is subject to the Installation Requirements and
Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Properties Standard Year
1507.1.1,T1507.1.1 Unrolling,Breaking Strength,Pliability ASTM'D226 2009
1507.1.1 Tear Strength ASTM D1970 2015
3. REFERENCES:
Entity Examination Reference Date
ITS(TST1509) Physical Properties 100539395COQ-006 10/27/2011
ITS(TST1509) Physical Properties 100539395COQ-002 10/27/2011
ITS(TST1509) Physical Properties 100539395COQ-006 03/14/2014
PRI(TST5878) ASTM D1970;Tear strength OCF-330-02-02 10/03/2017
ITS(QUA1673) Quality Control Service Confirmation 09/30/2017
4. PRODUCT DESCRIPTION:
4.1 RhinoRoof U20 is a multilayered polymer woven coated synthetic roof underlayment available in 42-inch
wide rolls,and can be produced in various other sizes;meets FBC 1507.1.1(Exception).
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory or test report from accredited testing agency for fire ratings of this product.
5.4 RhinoRoof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made to the Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof
covering.
5.5 Allowable Roof Covers:
TARGE 1 RooF CODER UPTIONS
Asphalt Wood Shakes Slate or
Underlayment Shingles Nail-On Tile Foam-On Tile Metal &Shingles Simulated Slate
RhinoRoof U20 YesIr1u
5.6 Exposure Limitations:
RhinoRoof U20 shall not be left exposed for longer than 30-days after installation.
Exterior Research and Design,U.C. Evaluation Report 140510.02.12-R3
Certificate of Authorization#9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL15216-R3
RhinoRoof Underlayments Revision 3:10/10/2017
Page 2 of 3
May 29,2019 10:06 AM To:17724621578 Page 5/5 From:XLR8 Roofing&Construction,LLC Fax:3212709369
--J TI%I I ERD
6. INSTALLATION:
6.1 RhinoRoof Underlayments shall be installed in accordance with Interwrap, Inc. published installation
instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application.
'*
6.3.1 Shall be installed in compliance with the requirements for ASTM D226, Type I or li underlayment in FBC
Table 1507.1.1 for the type of prepared roof covering to be installed, taking into account the wider sheet-
width for double-layer applications.
6.3.1 Fasteners:
For exposure<24 hours,corrosion resistant fasteners may be 1-inch roofing nails with a 3/8-inch diameter
head,or those noted in 6.4.2. The use of staples is prohibited.
For exposure > 24 hours up to maximum 30 days, corrosion resistant fasteners shall be minimum 1-inch
diameter plastic or metal cap nails or FBC HVHZ nails&1-5/8"diameter tin caps(with the rough edge facing
up). The use of staples is prohibited.
6.3.2 Single Layer; Roof Slope>4:12:
End(vertical) laps shall be minimum 6-inches and side(horizontal) laps shall be minimum 4-inches. Refer to
Interwrap, Inc. recommendations for alternate lap configurations and/or the use of sealant under certain
conditions.
For exposure < 24 hours, use of every-other fastening location printed on the surface is acceptable. For
exposure > 24 hours up to maximum 30-days, use of every fastening location printed on the surface is
required.
When batten systems are to be installed atop the underlayment, the underlayment need only be
preliminarily attached pending attachment of the battens on the same day. Battens shall not be positioned
over cap nails. If this occurs, remove the cap nail and patch the hole in accordance with Interwrap
published instructions.
6.4.3 Double Layer;2:12<Roof Slope<4:12:
End(vertical) laps shall be minimum 12-inches and side(horizontal) laps shall be minimum half-sheet-width
plus 1-inch.
Double layer application; begin by fastening a half-width plus 1-inch starter strip along the eaves. Place a
full-width sheet over the starter, completely overlapping the starter course. Continue as noted in 6.5, but
maintaining minimum half-width plus 1-inch side(horizontal)laps,resulting ih a double-layer application.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Qingdao,China
9. QUALITY ASSURANCE ENTITY:
Intertek Testing Services NA Inc.—QUA1673;(608)836-4400
END OF EVALUATION REPORT-
Exterior Research and Design,LLC. Evaluation Report 110510.02.12-113
Certificate cf Authorization 89503 6" EDITION(2017)FBC NON-HVHZ EVALUATION FL15216-R3
RhinoRoof Underlayments Revision 3:10/10/2017
Page 3 of 3