Loading...
HomeMy WebLinkAboutProduct Approval 1/29/2018 Florida Building Code Online lit. ® e e 8 8 ® ® e 8 SCIS Home Log In User Registration Hot Topics Submit Surcharge I Stats&Facts I Publications I FBC Staff SCIS Site Map I Links Search F�arida Product Approval ll�t USER:Public User RECEIVE® Product Approval Menu>Product or Application Search>Application List>Application Detail • FL# FLS444-1113 MAY 3 0 2019 Application Type Revision Code Version 2017 ST. Lucie County, Permitting Application Status Validated Comments Archived 0 MW - '3 " E Product Manufacturer CertainTeed Corp do -11ofin Address/Phone/Email 20 Moores Road Malvern,PA 19355 (610)893-5400 mark.d.harner@saint-gobain.com Authorized Signature Mark Harrier mark.d.harner@saint-gobain.com Technical Representative Mark D. Harrier Address/Phone/Email 18 Moores Road Malvern,PA 19355 (610)651-5847 Mark.D.Harner@saint-gobain.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles-- Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 0 Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 03/09/2020 Validated By John W.Knezevich,PE Validation Checklist-Hardcopy Received Certificate of Independence FL5444 R13 COI 2018 01 COI NIEMINEN.pdf Referenced Standard and Year(of Standard) Standard Year ASTM D3161 2016 ASTM D3462 2010 ASTM D7158 2011 Equivalence of Product Standards Certified By Sections from the Code hftps-//www.floridabuilding.org/pr/pr app dU.aspx7param=wGEVXQwtDgtahlg07CSsoycOrl28CcpCHZle8gwTPdZ3UOp/p2fwg2NQoQp/o3dp/pad 1/2 1/29/2018 Florida Building Code Online r Product Approval Method Method 1 Option D r� Date Submitted 01/24/2018 Date Validated 01/29/2018 Summary of Products FL# Model,Number or Name Description 5444.1 CertainTeed Asphalt Roof Shingles 3-tab,4-tab,strip(no-cut-outs),laminated and architectural asphalt roof shingles Limits of Use Installation Instructions Approved for use in HVHZ:No FL5444 R13 II 2018 01 FINAL ER CERTAINTEED ASPHALT Approved for use outside HVHZ:Yes SHINGLES F1_5444-1113.pdf Impact Resistant:N/A Verified By: Robert Nieminen,PE PE-59166 Design Pressure:N/A Created by Independent Third Party:Yes Other:Refer to ER Section 5 for Limits of Use Evaluation Reports FL5444 R13 AE 2018 01 FINAL ER CERTAINTEED ASPHALT SHINGLES FL5444-R13.Ddf Created by Independent Third Party:Yes Back Next Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an WEED employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 45S,F.S.must provide the Department with an email address if they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S., please dick baL. Product Approval Accepts: RIM _' ® fir Credit Card- SafC hftps://www.floddabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgtahlg07CSsoycOd28CcpCHZie8gwTPdZ3UO°/p2fWg2NQoQp/o3dp/p3d 2/2 �; Certificate of Authorization No.29824 CREEK17520 Edinburgh Dr Tampa,FL 33647 'T'ECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE,671 EDITION(2017) Manufacturer: Atlas Roofing Corporation Issued October 1, 2017 2000 Riveredge Parkway,Suite 800 Atlanta,GA 30328 (770)612-6267 htti)://www.atiasroofing.com Manufacturing Plants: Meridian, MS Calgary,Alberta Canada Dadra and Nagra Haveli, India Quality Assurance: UL LLC(QUA9625) SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 1507.1.1, 1518.4 Properties: Physical properties REFERENCES Enti Report No. Standard Year PRI Construction Materials Technologies(TST5878) ATL-033-02-01 ASTM D 226 2009 PRI Construction Materials Technologies(TST5878) ATL-101-02-01 ASTM D 6757 2016 ASTM D 226 2009 TAS 117(6) 1995 ASTM D 1781 1998(2012) PRI Construction Materials Technologies(TST5878) ATL-134-02-01 ASTM D 6757 2016 ASTM D 226 2009 ASTM D 4869 2016 PRI Construction Materials Technologies(TST5878) ATL-209-02-01 ASTM D 6757 2016 ASTM D 226 2009 ASTM D 4869 2016 PRODUCT DESCRIPTION Gorilla Guard® ASTM D 6757 and ASTM D 226,Type II mechanically fastened underlayment made from EverFelt Spec 30 asphalt-saturated organic felt reinforced with glass fiber for steep slope roof applications. Rolls are a nominal 36-inch wide by 72-ft long. Unless otherwise noted, the following application details shall be followed for New and Existing construction. ATI-13001.4 FL16226-R4 Page 1 of 3 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not specifically addressed herein. ` ATLAS ROOFING CORPORATION CREEKUnderlayments aiECHNICAL SERVICES, LLC APPLICATION INSTRUCTIONS Deck: The roof deck shall be constructed of closely fitted, solid sheathing for new or existing construction. New construction in the HVHZ shall be min. 19/32 in. plywood. Sheathing shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8"gap at abutting joints. Attachment(HVHZ): Underlayment shall be installed with a minimum 4-inch head lap and minimum 6-inch end lap and be fastened as specified in FBC Section 1518.2. Attachment (Non-HVHZ): Underayment shall be attached in accordance with the FBC Table 1507.1.1 and manufacturer's installation instructions Allowable roof coverings: Mechanically attached asphalt shingles, metal roof panels and shingles,wood shakes and shingles, and slate shingles. Clay and concrete tiles are allowable when installed with ASTM D 6830,ASTM D 249 organic cap sheet, or other approved undedayments in accordance with FBC requirements. LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) Wind uplift resistance in not within scope of this evaluation. 3) Installation of the evaluated product shall comply with this report,the FBC,and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) Deck substrates shall be clean, dry, and free from any irregularities and debris. Ali fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 5) Roof slope limitations shall be in accordance with FBC requirements. 6) The roof deck shall be constructed of closely fitted sheathing for new or existing construction. Roof deck shall be installed in accordance with FBC requirements. 7) All underlayments shall be installed with the roll length parallel to the eave,starting at the eave,and lapped in success courses installed up the deck in a manner that effectively sheds water from the deck. End laps shall be staggered between courses in accordance with the manufacturer's application instructions. 8) Roof coverings shall not be adhered directly to the underlayment. 9) The underlayment may be used as described in other current FBC product approval documents. 10) The underlayment shall be exposed on the roof deck for a maximum 30 days unless otherwise stated. 11) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. ATL13001.4 FI-16226-R4 Page 2 of 3 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not specifically addressed herein. ATLAS ROOFING CORPORATION CREEKUnderlayments 'KECHNICAL SERVICES, LLC COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code,6'"Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer. `° 111111111111' 017.10.0 v .'\G E N 2 No 74021 = 1 17.08.37 -04'00' �3 STATE OF :�IJJ .�'••�` p, �� Zachary R. Priest, P.E. 4 OR SS GNAT-ENN�` ,,` Organization No.ANE9641on No. 021 1/1/11111110 CERTIFICATION OF INDEPENDENCE CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E.does not have,nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. END OF REPORT ATL13001.4 FL16226-R4 Page 3 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein.