Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Product Approval (2)
4/10/2018 Florida Building Code Online BCIS Home Log In I User Registration I Hot Topicsy Submit Surcharge I Stats&Facts I Publications I FBC Staff I, BCIS Site Map Links I Search Florida - kk - `Product Approval USER:Public User SY.t�e�F1'�ugn Product Aooroval Menu>Product ar Apolication Search>Application List>Application Detail ^ECEIV�� e 'e FL# FL15216-R3 �( ! Application Type Revision MAY 3 0 2019 Code Version 2017 Application Status Approved ST. Lucie County, Permitting Comments Archived rJ UOPYProduct Manufacturer InterWrap,Inc. ALE Address/Phone/Email 32923 Mission Way Mission, NON-US 00000 (551)574-2939 mtupas@lnterwrap.com Authorized Signature Eduardo Lozano elozano@lnterwrap.com Technical Representative Eduardo Lozano Address/Phone/Email 32923 Mission Way Mission,NON-US 00000 (778)945-2891 elozano@interwrap.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer © Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity Intertek Testing Services NA,Inc.-QA Entity Quality Assurance Contract Expiration Date 09/30/2019 Validated By John W.Knezevich,PE G Validation Checklist-Hardcopy Received Certificate of Independence FL15216 R3 COI 2017 01 COI Nieminen.pd Referenced Standard and Year(of Standard) Standard ear ASTM D1970(tear) 2015 ASTM D226(physicals) 2009 Equivalence of Product Standards Certified By Sections from the Code https://www.floddabuilding.org/pr/pr app dg.aspx?param=wGEVXQwtDgv3yVVKJZ1QRAdhyl2u8kQGnf9ayHyTiLG8tW0uK8nwXA%3d%3d 1/2 4/10/2018 Florida Building Code Online Product Approval Method Method i Option D Date Submitted 10/10/2017 Date Validated 10/11/2017 Date Pending FBC Approval 10/15/2017 Date Approved 12/12/2017 Summary of Products FL# Model,Number or Name Description 15216.1 RhinoRoof Underlayments Synthetic roof underiayments Limits of Use Installation Instructions Approved for use in HVHZ:No FL15216 R3 II 2017 10 FINAL ER INTERWRAP RHINOROOF FL15216- Approved for use outside HVHZ:Yes R3.pdf Impact Resistant:N/A Verified By: Robert Nieminen PE-59166 Design Pressure:N/A Created by Independent Third Party:Yes Other:See ER Section 5 for Limits of Use. Evaluation Reports FI IS216 R3 AE 2017 10 FINAL ER INTERWRAP RHINOROOF FL15216- R3.pdf-- Created by Independent Third Party:Yes Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.goyrL t 20D7-2013 State of Florida.::Privaw Statement::Accessiblllty Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S., please dick here. Product Approval Accepts: M ® e_Cfieca M =~ Credit Card`, -Safe e https://www.floddabuilding.org/pr/pr app_dU.aspx?param=wGEVXQwtDgv3yWKJZ1QRAdhyl2u8kQGnf9ayHyTiLG8tW0uK8nwXA%3d%3d 212 EXTERIOR RESEARCH&DESIGN,LLC. Certificate of Authorization#9503 C)o 353 CHRISTIAN STREET,UNIT#13 \,JTPJNITY ERD OXFORD,CT 06478 PHONE:(203)262-9245 FAX:(203)262-9243 EVALUATION REPORT Interwrap,Inc. Evaluation Report 140510.02.12-R3 32923 Mission Way FL15216-R3 Mission,BC V2V-6E4 Canada Date of issuance:02/17/2012 (SSI)574-2939 Revision 3:10/10/2017 SCOPE: This Evaluation Report is issued under Rule 61620-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the e Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: RhinoRoof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity{ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION:Upon request,a copy of this entire Evaluation Report shall be provided to the'user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 3. Prepared by: Robert J.M.Nieminen,P.E. Florida Registration NO.59166,Florida DCA ANE1983The facsimile seal appearing was authorized by Robert Nieminen,P.E.on io/lo/2o17.This does not serve as an CERTIFICATION OF INDEPENDENCE: 1. Trinity I ERD does not have, nor does It intend to acquire or will it electronically signed document. distributing products It evaluates. acquire, a financial interest in any company manufacturing or 2, Trinity{ERD is not owned,operated or controlled by any company Manufacturing or distributing Products it evaluates. 3. Robert Nieminen P E.does no,have nor will acquire afinanclalinte whichthe,valua' * 4 tion reports are being issued. rest in any company manufacturing - Robert Nieminen,P.E.does not have,nor will acquire, Product. 5. This - a financial or distributing Products for Is a building code evaluation interest in any other entity 1pV0lVed,,the ProJect on sPeci which this P 197 Evaluation Re'port, pro PfGC C-,,ro cally for that Purpose. Or Previous It Neither TrinitylERD nor Robert NlefnnL yal C0ltiversions 'n't P.E,are in any way, the 1) 7 thereof " 17 islWaS Used- Per of v .,:�? *, �>.,;� :_,'=t,f=�=�'�.+il� ...>? _.',3'�a s... • ?{;. "f--. .F'i. •st.rsl i'9�3`'6i� �i°;"t P'n_f,F-<`'� �_ :'"ac ,in- lip"`a7 ' • �' _ .,le.., ,., 2si-';. •cfi ti.. 3�t ,_4 t . .ni i' _ ;.�,' �;i+ly4'a."n 't� .. _ T� et?t'.+,. . , ,r,Y • .t a. .. . .p.�1{'y3�dt(S( :i��� '; J1. ..,"1 C;�'?{;i:�.: ,jl'IV,:; _.F, ., ..:,.. i i..,. ,1; .8=il lUl j,cO;lF7:.y • - I, + � �-7. ..,.,t !. . 'i`� ,_ -{�' ..i i". ;t"i7"!.`., ,'! ';r ate.+-, au'.,.. ;�' :r•.. '- i Vt5 CJ t - :" • t t y 'r.. .a .,t. _ a t _.'3i.. ,S. •• ±t.^iii: .f ...a. •. .t • ;mj ,„-x;15+''• ) ii'� -3ii:, .:i. _ Cr,.}I.((� ... r W';`r{'�3�'?�}:•N �it•:'i � ,. � � ♦ � ,I`� I ` Lii J� � i (•s' tti, _ •\.•4i7�i{i.it 1 • y. \\JTRINITYIERD 6. INSTALLATION: 6.1 RhinoRoof Underlayments shall be installed in accordance with Interwrap, Inc. published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application. 6.3 ,.RhinoRoofU20: 6.3.1 Shall be installed in compliance with the requirements for ASTM D226,Type I or II underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed, taking into account the wider sheet- width for double-layer applications. 6.3.1 Fasteners: For exposure<24 hours,corrosion resistant fasteners may be 1-inch roofing nails with a 3/8-inch diameter head,or those noted in 6.4.2. The use of staples is prohibited. For exposure > 24 hours up to maximum 30 days, corrosion resistant fasteners shall be minimum 1-inch diameter plastic or metal cap nails or FBC HVHZ nails&1-5/8"diameter tin caps(with the rough edge facing up). The use of staples is prohibited. 6.3.2 Single Laver;Roof Slope>4:12: End(vertical)laps shall be minimum 6-inches and side(horizontal)laps shall be minimum 4-inches. Refer to Interwrap, Inc. recommendations for alternate lap configurations and/or the use of sealant under certain conditions. For exposure < 24 hours, use of every-other fastening location printed on the surface is acceptable. For exposure > 24 hours up to maximum 30-days, use of every fastening location printed on the surface is required. When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily attached pending attachment of the battens on the same day. Battens shall not be positioned over cap nails. If this occurs, remove the cap nail and patch the hole in accordance with Interwrap published instructions. 6.4.3 Double Laver;2:12<Roof Slope<4:12: End(vertical)laps shall be minimum 12-inches and side(horizontal)laps shall be minimum half-sheet-width plus 1-inch. Double layer application; begin by fastening a half-width plus 1-inch starter strip along the eaves. Place a full-width sheet over the starter,completely overlapping the starter course. Continue as noted in 6.5, but maintaining minimum half-width plus 1-inch side(horizontal)laps,resulting in a double-layer application. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Qingdao,China 9. QUALITY ASSURANCE ENTITY: Intertek Testing Services NA Inc.—QUA1673;(608)836-4400 -END OF EVALUATION REPORT- Exterior Research and Design,I.I.C. Evaluation Report 140510.02.12-113 Certificate of Authorization#9503 641 EDITION(2017)FBC NON-HVHZ EVALUATION FL15216-113 RhinoRoof Underlayments Revision 3:10/10/2017 Page 3 of 3