HomeMy WebLinkAbout2017 - Storm Panels - Residential - FL #119684/4/2019 Florida Building Code Online
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqsxYIeb4opODf7EcLX1ecJx4yFEEl8fMCsutu1tDWU4Tg%3d%3d 1/3
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search
Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #FL11968-R4
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer Eastern Metal Supply
Address/Phone/Email 4268 Westroads Drive West Palm Beach, FL 33407 (800) 432-2204 lrodriguez@easternmetal.com
Authorized Signature Bill Feeley lrodriguez@easternmetal.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Shutters
Subcategory Storm Panels
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the
Evaluation Report
Walter A. Tillit, Jr.
Florida License PE-44167
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2019
Validated By John Henry Kampmann Jr.
Validation Checklist - Hardcopy Received
Certificate of Independence FL11968_R4_COI_EASTERN METAL SUPPLY, INC. _DRAWING 17-098_
CERTIFICATION OF INDEPENDENCE.PDF FL11968_R4_COI_EASTERN METAL SUPPLY, INC._DRAWING 17-
095_CERTICATION OF INDEPENDENCE.PDF FL11968_R4_COI_EASTERN METAL SUPPLY, INC._DRAWING 17-096_
CERTIFICATION OF INDEPENDENCE.PDF FL11968_R4_COI_EASTERN METAL SUPPLY2c INC._DRAWING 17-
094_CERTIFICATION OF INDEPENDENCE.pdf
Referenced Standard and Year (of Standard)Standard Year
ASTM E330 2002
SSTD12-99 1999
Equivalence of Product Standards Certified By
Florida Licensed Professional Engineer or Architect
FL11968_R4_Equiv_EASTERN METAL SUPPLY, INC._DRAWING 17-
095_LETTER EQUIVALENCE BETWEEN SSTD 12-99 AND ASTM E-1996.PDF
4/4/2019 Florida Building Code Online
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqsxYIeb4opODf7EcLX1ecJx4yFEEl8fMCsutu1tDWU4Tg%3d%3d 2/3
FL11968_R4_Equiv_EASTERN METAL SUPPLY, INC._DRAWING 17-
098_LETTER OF EQUIVALENCE SSTD 12-99 AND ASTM E-1996.PDF FL11968_R4_Equiv_EASTERN METAL SUPPLY, INC_DRAWING 17-
096_LETTER EQUIVALENCE BETWEEN SSTD 12-99 AND ASTM E-1996.PDF FL11968_R4_Equiv_EASTERN METAL SUPPLY2c INC._DRAWING 17-094_
LETTER EQUIVALENT BETWEEN SSTD 12-99 AND ASTM E-1996.pdf
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 09/20/2017
Date Validated 10/28/2017
Date Pending FBC Approval 10/29/2017
Date Approved 12/12/2017
Summary of Products
FL #Model, Number or Name Description
11968.1 0.040" Bertha Aluminum Storm Panel
(2.25" Deep)- Non-HVHZ - Drawing
Number 17-094
Corrugated aluminum storm panels retained or not by tracks to
provide hurricane protection.
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Large Missile. Max. span is 12'-0" for +25, -25 p.s.f.
and 4'-0" for +125, -130 p.s.f. for sections 1, 3, 4, 6, 7, 8, 8A,
9 and 11. See sheet 10 of installation drawing for other spans
and pressures. Valid only for wind zones 1,2 & 3 as defined by
ASTM E-1996.
Installation Instructions FL11968_R4_II_EASTERN METAL SUPPLY2c INC._DRAWING
17-094_0.040 BERTHA ALUMINUM STORM PANEL.pdf Verified By: American Test Lab of South Florida Inc. Created by Independent Third Party: Yes Evaluation Reports FL11968_R4_AE_EASTERN METAL SUPPLY2c INC._DRAWING
17-094_PRODUCT EVALUATION REPORT.pdf Created by Independent Third Party: Yes
11968.2 0.050" Bertha Aluminum Storm Panel
(2.25" Deep)- Non-HVHZ - Drawing
Number 17-096
Corrugated aluminum storm panels retained or not by tracks to
provide hurricane protection.
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Large Missile. Max. span is 12'-11" for +30, -30 p.s.f.
and 8'-2" for +75, -80 p.s.f. for mountings without "h" header.
See sheet 5 of installation drawing for other spans and
pressures. Valid only for wind zones 1,2 & 3 as defined by
ASTM E-1996.
Installation Instructions FL11968_R4_II_EASTERN METAL SUPPLY, INC._DRAWING 17-
096_ 0.050 BERTHA ALUMINUM STORN PANEL.PDF Verified By: American Test Lab of South Florida Inc. Created by Independent Third Party: Yes Evaluation Reports FL11968_R4_AE_EASTERN METAL SUPPLY, INC._ DRAWING
17-096_PRODUCT OF EVALUATION REPORT.PDF Created by Independent Third Party: Yes
11968.3 24 Gage Galvanized Bertha Steel
Storm Panel (2.25" Deep)- Non-
HVHZ - Drawing Number 17-095
corrugated galvanized steel storm panels retained or not by
tracks to provide hurricane protection.
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Large Missile. Max. span is 9'-8" for +30, -40 p.s.f. and
7'-2" for +70, -80 p.s.f. for panels mounted without "H"
header. See sheet 4 of installation drawing for other spans and
pressures.Valid only for wind zones 1,2 & 3 as defined by ASTM
E-1996.
Installation Instructions FL11968_R4_II_EASTERN METAL SUPPLY, INC._DRAWING 17-
095_24 GAGE GALVANIZE BERTHA STEEL STORM PANEL.PDF Verified By: American Test Lab of South Florida Inc. Created by Independent Third Party: Yes Evaluation Reports FL11968_R4_AE_EASTERN METAL SUPPLY, INC._DRAWING
17-095_PRODUCT EVALUATION REPORT.PDF Created by Independent Third Party: Yes
11968.4 Clear Bertha Storm Panels (2 1/4") -
Drawing Number 17-098
corrugated polycarbonate storm panels retained or not by
tracks to provide hurricane protection.
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Large Missile. Max/ span is 10'-0" for +28, -28 p.s.f.
A.S.D. and 4'-0" for +105, -110 p.s.f. A.S.D desgin load. See
sheet 3 of installation drawings for other spans and pressures.
Valid only for wind zones 1,2 & 3 as defined by ASTM E-1996.
Installation Instructions FL11968_R4_II_EASTERN METAL SUPPLY, INC._DRAWING 17-
098_CLEAR BERTHA STORM PANEL 2.25.PDF Verified By: American Test Lab of South Florida Inc. Created by Independent Third Party: Yes Evaluation Reports FL11968_R4_AE_EASTERN METAL SUPPLY, INC._DRAWING
17-098_ PRODUCT OF EVALUATION REPORT.PDF Created by Independent Third Party: Yes
4/4/2019 Florida Building Code Online
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqsxYIeb4opODf7EcLX1ecJx4yFEEl8fMCsutu1tDWU4Tg%3d%3d 3/3
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts: