HomeMy WebLinkAboutPermit Packet-Michael Monk-8839 Delphinium CtAll APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED
Date: 6/03/2019 Permit Number:
i
Planning and Development Services
Building and Cade Regulation Division
2300 Virginia Avenue, Fort Pierce FL 34982
Phone: (772) 462-1553 Fax: (772) 462-1578
PERMIT TYPE: Electrical
PROPOSED IMPROVEMENT LOCATION:
Address: 8839 Delphinium Court
Property Tax ID #: 3425-703-0327-000-0
Site Plan Name:
Project Name: Monk
Building Permit Application
Commercial Residential x
Lot No.12
Block No. 30
I DETAILED DESCRIPTION OF WORK: I
Supply adequate power for tankless water heater
CONSTRUCTION INFORMATION:
Additional work to be performed under this permit —check all that apply:
_Mechanical _ Gas Tank —Gas Piping T Shutters _ Windows/Doors
✓Electric _ Plumbing _ Sprinklers
Total Sq. Ft of Construction: _
Cost of Construction: $ 850.00
Generator Roof Pitch
Sq. Ft. of First Floor:
Utilities: —Sewer _Septic Building height:
OWNERAESSEE:
CONTRACTOR:
Name Michael Monk
Name: Brian Stott
Address:8399 Delphinium Court
Company:Stott Brothers Electric
City: Port St Lucie State: _
Zip Code: 34952 Fax:
Phone No.
Address:385 NE Glentry Avenue
City: Port St Lucie State: FL
Zip Code: 34983 Fax:
Phone No 772-408-4911
E-Mail:
Fill in fee simple Title Holder on next page if different
from the Owner listed above)
E-Mail stottbrotherselectric@gmall.com
State or County License ER1 3015522
If value of construction is $2500 or more, a RECORDED Notice or commencement is required.
If value of HVAC is $7,500 or more, a RECORDED Notice of Commencement is required.
SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION:
DESIGNER/ENGINEER: Not Applicable
MORTGAGE COMPANY: ^ Not Applicable
Name:
Name:
Address:
Address:
City: State:
City: State:
Zip: Phone
Zip: Phone:
FEE SIMPLE TITLE HOLDER: Not Applicable
BONDING COMPANY: Not Applicable
Name:
Name:
Address:
Address:
City:
City:
Zip: Phone:
Zip: Phone:
OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated.
I certify that no work or installation has commenced prior to the issuance of a permit.
St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure
which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such
structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply.
In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work
in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review: room additions,
accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING
TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND
POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT."
Signature of Owner/ Lessee/Contractor as Agent for Owner Signature o ontractor/License Holder
STATE OF FLO DA t STATE OF FLQRIDA
:�_
COUNTY OF COUNTY OF �A2�
The forgoing instrument was acknowledged] efore me The for oing instrument was acknowledged before me
1 day 20tq by
this �_ day of 20 by this of
Name of person making statement. Name of person making statement.
Personally Known OR Produced Identification ✓ Personally Known OR Produced Identification
Type of Identification Type of Identification
Produced Produced Ca
'Ica A
(Signature of Notary P - to Qf da } MELISSAPE (Signature of Notary Public- 5 e of orida }
# GG 24840 vyq ME S PERRY
ommtssion �iaY
Commission No. fct� 2"L0L403 $ealtxpkesOcto�er712022 Commission No Cx'ZLt pL4Q �' * t Misslon#GG24S4i10
NlsrF of �t�e Banded Tstiru 8 yd9et Nntery 600415 uy a Expires Odobsr 7, 2022
7r C
REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEATURTLE MANGROVE
COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW
IVED
E
R
PLETED
4e
Stott Brothers
ELECTRIC
Electrical Contractor.
Phone #: 77I_J,.__.— Fax
Project: Ohoirk Location:
Existing Service 1~eeder Size: Existing Panel Size: t k
Main Breaker Size: M10 Number of Breakers:
Existing Loads
15140 Sq. Ft- X3watts per sq-ft............................ �J� watts
Appliance cir. @1500 watts each .................... k 00 watts
Laundrycir_@1500wattseach ...................... 150V watts
lRange @8kw................................................. 96706' watts
Dishwasher and disposal @ 1500 watts each...... 3rcw watts
Microwave @ 2000 watts ............................. JC00 watts
Water- heater @ 4-5 kw----.---_----------------- -- _ watts
Tankless water heater .................................. J watts
_�—Dryer @ 5 kw ...... .--......................... .......... �COP watts
Refrigerator@ 1500 watts ...................... G50t watts
Bathroom 1 @ 1500 watts .......................... 1500 watts
Sprinkler Pump ..----•-------- ........................ watts
Other
Other
Other ---------__.-.
New Loads
Poolpump .............. .....................•--•-------
Poollight .................... ---........ -.................
Heatpump -----------------------------------------------
Chlorine generator ......................................
Air blower ---------------------------------------------- -
-
watts
........._. watts
watts Subtotal y 2� Watts
watts
watts
watts
tivatts
watts
Boa#lit€-----------------------------------................. - q watts
Otherflt,t 141 f 95 ------------- _watts
Other ---------------- watts
Oilier ---------------- watts r�
Total Warms
First 10 kw @ 100%.----------------------------------- -------- 1 COOO watts
Remainder @ 40%---.... ----------------------------------------- --- I watts
A/C heat @ 100%............... .------------. sP' 1° watts
Total watts �J � Divided by 240 voltsdy-
Amps
Prepared leDate
TAb1&b1dg forms\Ne-wApp]icationslFormstElectrica7LaadCafcutations_doc 10/412007
Model
kW
Voltage: 240
Temp. Range 80°F-
1407
Max Amperage
Required Breaker
Wire Gauge
5ize
Weight
Water Connections
+ .r. €
64P NCO - 4�C4
ECO 8
ECO 11
ECO 18
ECO 24
ECO 27
ECO 36
8
13
18
24
27
36
✓
J
J
J
J
✓
✓
,/
J
J
J
✓
33
57
75
100
112.5
ISO
1x40AMP
lx60AMP
2x40AMP
3x40AMP
3x40AMP
4x4OAMP
1x8AWG
1x6AWG
2x8AWG
3x8AW0
3x8AWG
4x8AWG
11.5"x8"375
11.5'xB"375"
17"x14"x3J5"
17"x17'x3.75'
17"x17'x3.75'
17"x21"x3J5"
4.751bs
6.5 lbs
11.251bs
1375 lbs
1375 His
17.4lbs
1/2" CF
1/2" CIF
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
ECO 11 Electric Tankless
Water Heater
The ECO 11 is designed to heat up to 2
gallons per minute and is optimal for
weather of 67" F and above. It can be
used for multiple or single applications
depending on your climate. In warm
climates, the ECO 11 can handle two
sinks running simultaneously and one
shower, or two sinks simultaneously In
colder climates.
Compare with similar items
EGO 24 Electric Tankless
Water Heater
The ECO 24 has a slightly less heating
capacity than the ECO 27. In colder
climates as low as 37"F, the ECO 24 can
heat a shower and two sinks
simultaneously, and in warm climates,
three showers and two sinks.
EGO 27 Electric Tankless
Water Heater
The ECO 27 has a slightly more heating
capacity than the ECO Z4. In colder
climates as Low as 37"F, the ECG 27 can
heat 2 shower slmultaneousLy, and In
warm climates, it can heat up to tour
showers simultaneously.
ECO 36 Electric Tankless
Water Heater
The ECO 36 is the largest electric
tanklcss water h—ter produced by
ECOSmdrt. in colder climates as low as
377, the ECO 36 can heat a shower and
two sinks simuLtaneotisiy, and in warm
dimates, three showers and two -and -a -
half sinks.
0
Michelle Franklin, CFA -- Saint Lucie County Property Appraiser --All rights reserved.
Property Identification
Site Address:
Parcel ID:
Account #:
Map 1D:
Use Type:
Zoning:
City/County:
Ownership
Michael 7 Monk
Nicole P Monk
8399 Delphinium Ct
Port St Lucie, FL 34952
Legal Description
SAVANNA CLUB PLAT THREE BLK 30 LOT 12 (OR 3299-2907)
Current Values
rust/Market Value:
$89,800
Assessed Value:
$65,837
Exemptions:
$40,837
Taxable Value:
$25,000
Property taxes are subject to change upon
change of ownership.
• Past taxes are not a reliable projection of future taxes.
The sale of a property will prompt the removal of all
exemptions, assessment caps, and special classifications.
Taxes for this parcel: SIX Tax Collector's Office 0
Download TRIM for this parcel: Download PDF ❑
Date:
Book/Page:
Sale Code:
Deed:
Grantor:
Price:
Date:
Book/Page:
Sale Code:
Deed:
Grantor:
Price:
Date:
Book/Page:
Sale Code:
Deed:
s399 DELPHII41UM CT
3425-703-0327-000-0
129203
34/25S
0200
PUD
Saint Lucie County
Total Areas
Finished/Under Air (SF): 1,540
Gross Sketched Area (SF): 2,142
Land Size (acres): 0.12
Land Size (SF): 5,314
Sale History
May 26, 2011
3299 / 2907
0001
WD
Gruber (LF EST) Ann R
$95,000
Apr 1, 2009
3083/0545
0114
WD
GruberAnn R
$100
Feb 5,2001
1363 / 2515
XX01
QC