HomeMy WebLinkAboutUntitledWind Load Calculation a f k
` dr fu7
r puac ;
SCC131150472
Property Information Building Infonnation j
Owner: TIMOTHY&LACEY BUXTON w Wind Zone: 170 MPH,
Address: 470 WOODCREST DR ; Exposure Category: C
FORT PIERCE,FL 34945 Minimum Building Dimension: 52 ft.
Mean Roof Height: 12 ft.
Risk Category: II
Design Pressure Calculations i
Opening Location Device Device —i Device Max Positive M -Negative
Number Zone i Width(in) Height(m)� Elevation(ft) Pressure(psfJ ]� Pressure(ps fl
1 Int 37 80 7 36.0 -39.2
__... ...............
-
2 Int 52 61 7 35.9 -39.1
.. .-------— ..___....._.. — ....... ........ —..-... .. ...... _— ....... .......... -- _ -._...
3 Int 52 61 7 35.9 -39.1
--............- - -......-
4 Int 52 61 7 35.9 -39.1
--.. -..---1-1-1-1-1-1--1 ........ ------- -- ......... . -- - _—._.-- -- ---._ .......................-I..----.,---,.-. _..-
5 Int 36 37 7 37.8 -41.0
--- ---............-- ---------..-.........-- -............................. ----....._........
...-..--
6 It 52 61 7 35.9 -39.1
— —. _ I
......
7 End 52 61 7 35.9 -46.7
— --.........................- - - - —.-.-.........._..... _._..........._....... ....._......
--- _ _._.-.-.
8 End 25 11 7 37.8 -50.6
-- - ....... . . .... ........ ...---- ............................... ...... .....----
. ..........
9 End 25 48 7 37.8 -50.6I
1.0 Int 72 1.1 ......... ................ ...... ........ -----._ 37.3 _
11 Int 36 48 -40.6----�
- ....._. -..--- ---- --- ----- ...... ----- ........ .IL -- ---- - - ----a
12 Int 36 48 7 37.3 -40.6 j
ff IN
RECEIVC-b
JUN 0 4 2019
ST. Lucie County, Permitting
Prepared in accordance ivith:ASCE 7-10,Chapter 30.Blind Loads-Components and Cladding.6th Edition(2017)Florida Building Code.
Page 1 of 1
® i ® ® � • ®.® ® •. .
lll lig I loll lip
A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET
Definition of Corner Zone-10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft.
PRODUCT APPROVAL REQUIRED OPENING MAXIMU MULTIPLE
OPENING (Location) IS THIS A PRODUCT ROUGH ARE
GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW
LOCATION Corner Zone WINDOW ACCEPTANCE OPENING SHUTTERS
NUMBER or Interior OR DOOR TYPE NUMBER + PSF TESTED MULLION
( ) (-)PSF (+)PSF (-)PSF SIZE DIMENSIONS REQ Y/N/NA REQ YIN
1 Int Door Solid FL15210.1 75 75 36.0 . -39.2 31.5" 37x80 No No
2 Int Window 7/e"Lmni1G FL15780.8 55, 65 35.9 -39.1 54x76.5 52x61. No No
3 Int window 7/8"Lami IG FL15780.8 55 65 35.9 -39.1 54 X 76.5 52x61 No No
4 Int Window 7/8"I.amiIG FL15780.8 55 65 35.9 -39.1 54x76.5 52x61. No No
5 Int window 7/8"Lauri IG FL15780.8 55 65 37.8 -41.0 54 X 76.5 36x37 No No
6 Int Window 778"LainiIG FL15780.8 55 65 35.9 -39.1 54x'6.5 52x61. No No
7 End Window 7;8"L.ami IG FL15780.8 55 65 35.9 -46.7 54 X 76.5 52x61 No No
8 End Window VLamiIG FL13010.4 55 55 37.8 -50.6 48X72 25x11 YES No
9 End Window 716"Lauri IG FL15780.8 55 65 37.8 -50.6 54 X 76.5 25x48 YES 'No
10 Int Window 1"LamiIG FL13010.4 55 55 37.3 -40.6 48X72 72xII YES No
11. Int window 7/8"LamiIG FL15780.8 55 65 37.3 -40.6 54X76.5 36x48 YES No
12 Int Window ' 7/8"UiiniIG FL15780.8 55 65 37.3 -40.6 54x76.5 36x48 YES No
JUN 04 2019
County, Permittin