FL# FL1654 R22 S �00 �EP�g�M PO
Application Type Revislon
Code Version 2017 ��v1E' j
Application Status Approved Pp'lc NS N0 INSP i•
Comments SZ��
Archived ❑
Product Manufacturer POLYGLASS USA
Address/Phone/Emall 1111 W.Newport Center Drive
Deerfield Beach,FL 33442
(954)233-1330 Ext 242
malpert@polyglass.com
Authorized Signature Maury Alpert
tnalpert@polyglase.com
Technical Representative Maury Alpert
Address/Phone/Emall 1111 W.Newport Center Drive
Deerfield Beach,FL 33442
(912)429-8610
MAlpert@polyglass.com
Quality Assurance Representative Ariel Lender
Address/Phone/Email 1111 W.Newport Center Drive
Deerfield Beach,FL 33442
(954)233-1230
ALender(apolyg lass.com
Category Roofing
Subcategory Modified Bitumen Roof System
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
❑ Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59156
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 09/13/2021
Validated By John W.Knezevich,PE
Q Validation Checklist-Hardcopy Received
Certificate of Independence FLIG54 R22 COI 2017 01 COI_!�ier^i•^•s.^.^df
Referenced Standard and Year(of Standard) Standard Year
ASTM D6162 2008
ASTM D6163 2008
ASTM D6164 2011
ASTM D6222 2011
ASTM D6509 2009
FM 4470 2012
FM 4474 2011
UL 1897 2012
Equivalence of Product Standards
s Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 09/14/2017
Date Validated 09/15/2017
Date Pending FBC Approval 09/22/2017
Date Approved 12/12/2017
Date Revised 10/06/2018
Summary of Products
FL# Model,Number or Name Description
1654.1 Polyglass SBS and APP Modified SBS and APP modified bitumen roof systems
Bitumen Roof Systems
Limits of Use Installation Instructions
Approved for use In HVHZ.•No FL1654 R22 fI 2017 09 FINAL Al ER POLYGLASS MODBIT FL1654-
Approved for use outside HVHZ:Yes R22.odf
Impact Resistant:N/A Verified By:Robert Nleminen PE-59166
Design Pressure:+N/A/-622.5 Created by Independent Third Party:Yes
Other:1.)The design pressure in this application Evaluation Reports
relates to one particular assembly over concrete Fl 1654 R22 AE 2017 09 FINAL ER POLYGLASS MODBIT FLI654-
deck.Refer to the ER Appendix for other systems R22,odf
and deck types.2.)Refer to ER,Section 5 for other Created by Independent Third Party:Yes
Limits of Use.
FR FNZR
eomact U4::2601 otairgtone Road,Tallahassee Fl.32399 Phone:950487-1024
The State of Florida Is an An/EEO employer.002y0Rht 2007-2013 State of Flonda.::Ptivacy statement::A�mmity Statement r:Re nd men
Under Florida law,emml addresses=Public records.rrYou do not want your a-mail address released in response to a pubdo-tecsrds rMuest,do not send electronic
mail to this entity.instead,contact the office by phone or by traditlonel mail.If you have any questions,please contact 050.487.1395.*Pursuant to Section 455.275(1),
Florida statutes,effective octaber 1.2012,1Ic nsees licensed under cnapter 455,F.S.must provide the Department with an email address It thdy have ane.The emads
provided may be used for official communication with the licensee.However emaa addresses are public record.It you do not wish to supply a pemmnal address,please
provide the Department with an email address which can be made available to the public.To determine it you are a licensee under chapter 455,F.S.,please dick here.
Product Approval Accepts
®®® °COK
Credit Card
Safe
L�
TRINITY'ERD
_..
.." TABLEaF2:WOOD.DECKS NEVi(CONSTRUCTION;A�ROOF(TEs�ROFF�OR RECOVER '?„
SiYSTEMTYPEE:NON-INISUTATEDjMECHANICALLY'ATTACHEDBA$E'SHEET(StR &.P
&SIATFS);BONDEDROOFCOVER'
System Base Sheet Roof Cover(Note 15) MDP
No. Deck(Note 1) Type Fasten Attach Base Ply Cap (psf)
'ScLF-ADHEPJNG BA E-PLY:. - - .
W-136 Min.19/32- Elastobase,Elastobase P Dekfast Hex(aka,Dekfast PLT-H-2-7/8)with Dekfast 414 12-Inch o.c.in 4-Inch lap and 12-Inch o.c.in two SBS-SA,APP-SA SBS-
SBS-SA TA APP TA -52.5•
s
Inch plywood (poly-fllmtop) arTrufazequally t3"MetellnsulationPlatewithTrufastHD (2), q y paced,staggered center rows
W-137 Min.19/32- Elastobase,Elastobase P Dekfast Hex(aka,Dekfast PLT-H-2-7/8)with Dekfast 4114 12-Inch o.c.in 4-Inch lap and 12-Inch o.c.In two Polyflex SA Base APP TA -525•
Inch plywood (poly-film top) orTrufast 3"Metal Insulation Plate with Trufast HD (2),equally spaced,staggered center rows
W-138 Min.19/32- Elastobase,Elastobase P OMG Flat Bottom Plates(square)with Roofgrip 412 12-Inch o e.in 4-inch lap and 12-Inch o.c.in two SBS-SA SBS-SA,APP-SA,SBS- .60.0•
Itch plywood (poly-film top) (2),equally spaced,staggered center rows TA,APP TA
W-139 Mie.19/32- Elastobase,Elastobase P Fo
MG Flat Bottom Plates(square)with Roofgrip 412 124nch o.c.In 4-Inch lap and 12-Inch o.c.in two Poigflex SA Base APP TA -60.0'
Itch plywood (poly-film top) (2),equally spaced,staggered center rows
:.:`:: '' -•': TABLEiG:v6dil)DECNS�NEVIICONSTRUCTIONoxREf(QOF.'(T ia-QFF):;
77
V..
SYSTEM TYPE F:NON=INSUI ATED.BONDiD
AOOF,C9 ER '
System Dedc(Note 1) Primer Roof Cover(Note 151 MDP(psf)
No. JolntTreatment Base Ply Ply Cap Ply
W-140
" Min.15/32- None None SBS-SA (optional)SBS-SA,SBS- SBS-SA,APP-SA,SRS- _ 90.0
Inch'.plywood TA,APP TA TA,APP-TA
W-141 Min.15/32- (Optlonaq PG200. None PolyflexSA Base (Optional)APP-TA APP TA -90.0
Inch plywood
W-142 Min.15/32- PG100 None SBS-SA (Optional)SBS-SA,SBS- SBS-SA,APP-SA,SBS- 975
inch plywood TA,APP TA TA,APP TA
Min- o Plywood joints are covered with 4-inch wide strips of ElastoflexSAV Plus,rolled Into Elastoflex SAV Base or (Optional)SBS-SA,SBS- SBS-SA,APP-SA,SBS- -97.5
W-143 inch plywood (Optional)PG100 place to create continuous bond. ElastoflexSA V FR Base TA,APP TA TA,APP TA
W-144 Min.15/32- WB-3000 None SBS-SA (Optional) SBS-SA,APP-SA,SBS- -105.0
Inch plywood I TA,APP-TA
Min.15/32- Plywood joints are covered with 4-Inch wide strips of Elastoflex SA V Plus,rolled into Elastoflex SAV Plus or (Optional)SBS-SA,SBS- SBS-SA,APP-SA,SBS- -135.0
W-145 inch plywood (Optional)PG100 place to create continuous bond. Elastoflex SAV Plus FR TA,APP TA TA,APP TA
W-146 Min.15/32 (Optional)PG300 Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Pius,rolled Into Polyflex SA Base (Optional)APP TA APP TA -135.0
inch plywood place to create continuous bond.
Exterior Research and Design,I.I.C.d/b/o Trinity I ERI Evaluation Report P9290.02.08-R20 for FL1654R22
Certificate of Authorization 49503 6'"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 20:09/12/2017
Prepared b�:Robert Nieminen,PE-59166 Polyglass Modified Bitumen Root Systems;(570)380-1230 Appendix 1,Page 21 of 58
,%,I TRINITY I ERD
APOENDIX 15AT rACHMENi REQUIREMENTS FOR WIND UPLIFT RESISTANCE-
Table Deck Application Type Description Page
1A Wood New or Reroof(Tear-Off) A-1 Bonded insulation,Bonded Roof Cover 5
SB-1 Wood New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 5-9
18-2 Wood New Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 10.11
1C Wood New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 11
ID Wood New Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 12.13
1E Wood New,Reroof(Tear-Off►or Recover D Prelim.Attached Insulation,Mech.Attached Base Sheet,Bonded Roof Cover 14-15
IF-1 Wood New or Reroof(Tear-Off) E- Non-Insulated,Mech.Attached Base Sheet(nails),Bonded Roof Cover 16-18
IF-2 Wood New Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base_Sheet(screws&plates),Bonded Roof Cover 19-21
1G Wood New or Reroof(Tear-Off) F Non-Insulated Bonded Roof Cover 21
2A Steel or Structural concrete New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 22.24
2B Steel or Structural concrete New,Reroof(Tear-DM or Recover C Mech.Attached Insulation,Bonded Roof Cover 25-28
2C Steel or Structural concrete New,Reroof(Tear-Off)or Recover D Prelim.Attached Insulation,Mech.Attached Base Sheet,Bonded Roof Cover 29-31
3A Structural concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 32-40
38 Structural concrete New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 40
4A LWIC New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 41.42
4B LWIC New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 43
4C LWIC New or Reroof(Tear-Off) E Non4n5ulated,Mech.Attached Base Sheet,Bonded Roof Cover 44-46
SA CWF New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 47
SB CWF New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 48
5C CWF New,Reroof(Tear-Off)or Recover B Meeh.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 49
SO CWF New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 49
SE CWF New,Reroof(Tear-Of)or Recover E Non-insulated,Mech,Attached Base Sheet,Bonded Roof Cover 49
6A Gypsum Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 50-52
6B Gypsum Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 52
6C Gypsum Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 53
6D Gypsum Reroof(Tear-Off)or Recover E Non-insulated,Mech.Attached Base Sheet,Bonded Roof Cover 53
7A Various Recover A-1 Bonded Insulation,Bonded Roof Cover 54-58
78 Various Recover F Non-Insulated,Bonded Base Sheet,Bonded Roof Cover 58
The following notes apply to the systems outlined herein:
1. The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation.
2. Insulation/base sheet fasteners shall be of sufficient length for the following deck engagement:
D Wood: Minimum 0.75-Inch penetration.
D Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck.
D Structural concrete: Minimum i-Inch embedment Into pilot hole In accordance with fastener manufacturer's published installation instructions.
3. Unless otherwise noted,insulation may be any one layer or combination of polylsocyanurate,polystyrene,wood fiberboard,perlite,gypsum-based roof board or mineral-wool roof board that meets the QA
requirements of F.A.C.Rule 61620-3 and is documented as meeting FBC 1505.1 and,for foam plastic,FBC Chapter 26,when installed with the roof cover.
Exterior Research and Design,U.C.d/b/a Trinity I ERD Evaluation Report P9290.02.08-R20 for FL2654-R22
Certificate of Authorization 49503 61"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 20:09/12/2017
Prepared ba:Robert Nleminen,PE-59166 Polyglass Modified Bitumen Roof Systems,(570)384-1230 Appendix 1,Page 1 of 58
TRINITY ERD
15. Unless otherwise noted,refer to the following references for bonded base,ply or cap sheet applications.
:. TA9lE1.P.OLYGIASSFIOOP OVERZ.
Reference Laver I Material Application
BP-AA Base Ply One or more plies Polyglass G2 Base,FBC Approved ASTM D4601,Type 11 Hot Asphalt at 20.40
(Base and Ply sheets,Asphalt- Ply One or more piles Polyglass Ply IV,Polyglass Ply VI,FBC Approved ASTM D2178,Type IV or VI lbs/square
Applied) Note: Asphalt-opplied sheets or insulation shall not be applied to of• Im surfaced membranes.
Base Ply One ply Elastobase(sand/sand),Elastoflex V,Elastoflex 56,Elastoflex S6 Type 11,Poly lass HT Base 650 PG 35(I at 1.5-2.0
SBS-CA1 Cap Ply Elastoflex VG,Elastoflex VG FR,Elastoflex S6,Elastoflex S6 Type 11,Elastoflex S6 G,Elastoflex S6 G FR,Elastoshleld TS-P,Elastoshield gal/square
TS-G FR,Pol fresko G SBS(sand-backed),Polyfresko G SOS FR(sand-backed
Base Ply One ply Elastobase(sand/sand),Elastoflex V,Elastoflex S6,Elastoflex S6 Type 11 Polyplus 35 at 1.5-2.0
SBS-CA2 Gap Ply Elastoflex VG,Elastoflex VG FR,Elastoflex S6,Elastoflex S6 Type 11,Elastoflex S6 G,Elastoflex S6 G FR,Elastoshleld TS-G,Elastoshleld gal/square
TS-G FR,Pol fresko G SBS (sand-backed),Po[Vfresko G SBS FR(sand-backed)
Base Ply or Ply One or more plies Elastobase(sand/sand or poly/sand),Elastobase P(sand/sand or poly/sand),Elastoflex V,Elastoflex 56,Elastoflex
56 Type Il,Polyglass HT Base 650
SBS-AA Hot Asphalt at 20.40
(SBS,Asphalt-Appped) Cap Ply Elastoflex V,Elastoflex VG,Elastoflex VG FR,Elastoflex S6,Elastoflex S6 Type II,Elastoflex S6 G,Elastoflex S6 G FR,Elastoshleld TS-G, lbs/square
Elastoshleld TS-G FR,Polyfresko G SBS(sand-backed),Pol resko G SBS FR(sand-backed)
Note: Asphalts lied sheets or Insulation shall nut be app"to poly-film surfaced membranes.
One or more plies Elastobase(sand/poly),Elastobase(poly/poly),Elastoflex V,Elastoflex S6,Elastoflex 56 Type 11,Polyglass HT Base
SBS-TA Base Ply or Ply 650
(SBS,Torch-Applied) Elastoflex V,Elastoflex VG,Elastoflex VG FR,Elastoflex 56,Elastoflex S6 Type 11,Elastoflex S6 G,Elastoflex S6 G FR,Elastoshield TS-G, Torch-Applied
Cap Ply Elastoshleld TS-6 FR,Polyfresko G SBS(poly-flim backed),Polyfresko G SBS FR(poly-film backed)
Base Ply One or more plies Elastoflex SA V Base,Elastoflex SA V fR Base,Flastoflex SA V Plus,Elastoflex SA V Plus FR
SBS-SA Cap Ply Elastoflex SAP Elastoflex SA P FR,Poi reflect Self-Adhering
(SBS,Self-Adhering) Note: Unless otherwise noted,permissible membirane substrates for SBS-SA are limited to the SOS-SA Base Ply options herein,
Elastobase(of/sand)or Elastobase(poly/sty).
APP-CAi Cap Ply PolyflexG FR PG350 at 13-2.0
gal/square
APP-TA Base Ply or Ply One or more plies Polyglass APP Base,Polyflex,Po(bond- Torch-Applied
(APP,Torch-Applied) Cap Ply Polyflex,Polyflex G,Polyflex G FR,Pol bond,Polybond G,Polyfresko G,PolVfresko G FR
APP-SA Cap Ply Polyflex SA P,Polyflex SA P FR,.PoI resko G SA;Poi kool
(APP,Self-Adhering) Note: Unless otherwise noted,permissible membrane substrates forAPP-SA are 1/mhed to theSBSSA Base Ply options herein, Self-Adhering-
Elastobase(poly/sand)or Elastobase(polylpotyl.
16. Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect on the system wind load performance. Refer to current Roofing Materials Directory for fire ratings
associated with coating usage.
P PG200 Tion Shared Roof Coating;
P PG300 Fibered Roof Coating;
D PG600 Non-Fibered Aluminum Roof Coating;
D PG650FIberedAluminum Roof Coating;
P P67oo High Quality Elastomeric Roof Coating or KM Acryl 25;
Y P67000S(QuickSet)High Quality Elastomeric Roof Coating or KM Acryl 25-QS(forgranule-surfaced APP or SBS only);
➢ PG800 Asphalt Emulsion Roof Coating;
P Polyplus 60 Premium Non•Rbered Aluminum Roof Coating:
P Polyplus 65 Premium Fibered Aluminum Roof Coating;
P Polybrite 70 Premium Grade Elastomeric Roof Coating or KM Acryl 35;
P Polybrite 7GQS(Quick Set)Premium Grade Elastomeric Roof Coating or KM Acryl 15-QS(forgranule-surfaced APP or SBS only);
0P Polybrite 90 High SolidsSillcone Roof Coating or Polybrite 95 Silicone Roof Coating.
Exterlor•Research and Design,U.C.d/b/a Trinity IERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization#9503 6'n EDITION(2017)FBC NON-HVHZ EVALUATION Revision 20:09/12/2017
Prepared tis Robert Nieminen,PE-59166 Polyglass Modified Bitumen Roof Systems,(570)384-1230 Appendix 1,Page 3 of 58