•P'o k FL# FL21388-R2 F3 rn
Application Type Revision C G
Code Version 2017
m
Application Status Approved o y
�3
Comments
Archived
Product Manufacturer Dynamic Metals
Address/Phohe/Email 3201 SE Dominica Terace
Stuart,FL 34997
(772)872-8030
juan@dynamicmetal.net
Authorized Signature Lara]esus
juan@dynamicmetal.net
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Scott Wolters
the Evaluation Report
Florida License PE-62354
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration Date 12/06/2026
Validated By Lucas A.Turner,P.E.,MBA
4 Validation Checklist-Hardcopy Received
Certificate of Independence FL21388 R2 COI Dvn COI.odf
Referenced Standard and Year(of Standard) Standard Year
UL580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 06/20/2018
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgve007nSKOaGDhTy... 6/11/2019
Florida Building Code Online Page 2 of 3
Date Validated 06/20/2018
Date Pending FBC Approval 06/27/2018
Date Approved 08/15/2018
Summary of Products
/ F Model,Number or Name Description
21388.1 1"Nailstrip-24 Ga Steel Galvalume 1"Nailstrip,24 Ga Steel Galvalume non-structural roof panel
Limits of a Installation Instructions
AP
,Ptov for use in HVHZ:No FL21388 R2 II 213881D.Ddf
pro d for use outside HVHZ:Yes Verified By: Scott Wolters 62354
Impact Resistant:N/A Created by Independent Third Party: Yes
design Pressure:+N/A/-206 Evaluation Reports
Other:Fasteners at 6"OC and 6"from ends. FL21388 R2 AE 213881E.Ddf
Created by Independent Third Party:Yes
21388.2 1-1/2"Nailstrip-.032 Aluminum 1-1/2"Nailstrip, .032 Aluminum non-structural roof panel
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL21388 R2 II 213882D.Ddf
Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure: +N/A/-168.5 Evaluation Reports
Other:Fasteners 6"OC and 6"from ends FL2.1388 R2 AE 213882E.Ddf
Created by Independent Third Party:Yes
21388.3 1 1/2"Nailstrip-24 Ga Steel 1-1/2"Nailstrip,24 Ga Steel non-structural roof panel
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL21388 R2 II 213883D.odf
Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354
Impact Resistant:N/A Created by Independent Third Party: Yes
Design Pressure:+N/A/-153.5 Evaluation Reports
Other:Fasteners 6"OC and 6"from ends FL21388 R2 AE 213883E.Ddf
Created by Independent Third Party:Yes
21388.4 1 3/4"Snaplock .032 Aluminum 1-3/4"Snaplock .032Aluminum non-structural roof panel
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL21388 R2 II 213884D.Ddf
Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354
Impact Resistant:N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-191 Evaluation Reports
Other:Field Installation Uplift DP: clips at 16"OC and FL21388 R2 AE 213884E.Ddf
4"from ends equals 146 psf(includes FS=2);Corner Created by Independent Third Party:Yes
Installation Uplift DP: clips at 8"OC and 4"from ends equals
191 psf(includes FS=2)
21388.5 1-3/4"Snaplock-24 Ga Steel 1-3/4"Snaplock,24 Ga Steel non-structural roof panel
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL21388 R2 II 213885D.Ddf
Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354
Impact Resistant:N/A Created by Independent Third Party: Yes
Design Pressure: +N?A/-243 Evaluation Reports
Other:Field Installation Uplift DP: Clips at 16"OC,equals FL21388 R2 AE 213885E.odf
-176 psf(includes FS=2);Corner Installation Uplift DP: Clips Created by Independent Third Party: Yes
at 8"OC,equals 243.5 psf(includes FS=2)
21388.6 5V Crimp-.032 Aluminum 5V Crimp,.032 Aluminum non-structural roof panel
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL21388 R2 II 213886D.Ddf
Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:+N/A/-183 Evaluation Reports
Other:Fasteners at 12"OC and 6"from ends. FL21388 R2 AE 213886E.Ddf
Created by Independent Third Party:Yes
Back Next
Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Coovriaht 2007-2013 State of Florida.::Pnvacv Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to Section 455.275
(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The
emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please
click here.
Product Approval Accepts:
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgve007nSKOaGDhTy... 6/11/2019
- --WOLTERS ENGINEERING
ENGINEERING, DRAFTING,CONSULTING
15211 971"Road N
West Palm Beach,FL 334'12
Ph/Fx: (561)225-1982
PRODUCT EVALUATION
PRODUCT: DYNAMIC 1" NAILSTRIP 24 GAUGE STEEL ROOF PANEL (FLPA#21388.1)
MANUFACTURER: DYNAMIC METALS, LLC
340 PIKE ROAD
WEST PALM BEACH, FL 33411
To all concerned,
The Dynamic 1" Nailstrip 24 Ga. Steel Roof Panel, manufactured by Dynamic Metals LLC, is a non-
structural galvalume coated steel roof panel (50 ksi min) that meets the requirements of Section 1507.4.3 of the 6th
Edition (2017) Florida Building Code. The panel has been tested per UL580-06 by Intertek-ATI, with results shown
in test report G1195.06-450-44.
Technical Documentation-.-
1.
ocumentation:1. Drawing "NSS16" dated 6/1818 signed and sealed b Scott Wolters PE.
9 Y
2. Test Reports listed above by Architectural Testing, Inc. signed and sealed by Charles Anderson, PE.
3. Supplemental Calculations to support"NSS16"drawing, signed and sealed by Scott Wolters, PE.
I have reviewed this submittal per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005
'I
(4). Based on the limitations listed below and those provided in the documents above this product meets all the,
( ) p �
requirements of the 6th Edition (2017) Florida Building Code generally, and chapter 15 specifically, for use outside
of the HVHZ.
Limitations: This panel is approved for use outside of the HVHZ.
Overall Limitations: Maximum Panel Width: 16" (nominal)
Fastener spacing across panels: 16" O.C. (at nailstrip)
(Panels overlap with male/female snap fit)
Maximum Design Pressure: 206 psf.
Max. Fastener Spacing: 6" from ends, 6" max. O.C.
Min. Panel Fastener: #10-9x1" PancliP MTW fastener
5PFCIP OHNIG IN Ii,I IAC1, FE515T�i�11"CUp1"AIN`dV�l,LS, 5(OpEFpOi`iTS, & 1NIN701rJ5
Underlayment: 1 layer of 30 lb. organic felt paper with 4"overlaps
(or)
Any underlayment with a valid FLPA or Miami-Dade NOA
Fire Barrier: 1 layer of VersaShield with 4"overlaps
(or)
Any fire barrier with a valid FLPA or Miami-Dade NOA
Minimum Substrate: !/2' (15132"min)4-ply CDX Plywood, nailed to 2x rafters spaced 24"max.
O.C. with 8d ring-shank nails spaced 4" O.C.
Other Limitations: Roof slope must meet requirements of FBC Section 1507.4.2.
Fire classification is not a part of this evaluation.
Shear diaphragm values are not a part of this evaluation.
Design of substrate is by others and is not a part of this evaluation.
If you have any questions or need more information concerning this approval please contact me.
Thank you,
FL PE# 62354
JUN 19 7016
\iAL
CWTAINWP0,5, 5fOffTPON1_5, & W11\vOWc'