Loading...
HomeMy WebLinkAboutProduct Approval-Shingle Ply Roof systems Florida Building Code OnlineFile C film ' Page 1 of 2 ®W F-WF-D FOR E C OMPUANCEWk u ® + t t �w. I. BCIS Home Log In User Registration Hot Topics Submit Surc b,S$t�Facts Publications Contact Us BCIS Site Map Links Search *r rida (NJ" • t ra Product Approval aI I USER:Public User Product Approval Menu>Product or Application Search>Aoolication List>Application Detail WIN.1 1 '�, ,� !, FL# FL12772-R5 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Mule-Hide Products Co.,Inc. Address/Phone/Email 1195 Prince Hall Dr Beloit,WI 53511-5481 (608)365-3111 Ext 809 lindar@nemoetc.com Authorized Signature Timothy McFarland lindar@nemoetc.com Technical Representative Tim McFarland Address/Phone/Email 1195 Prince Hall Dr Suite A Beloit,WI 535115481 (608)365-3111 tim.mcfarland@mulehide.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Single Ply Roof Systems Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/14/2021 Validated By John W. Knezevich, PE Validation Checklist-Hardcopy Received Certificate of Independence FL12772 R5 COI 2017 01 COI Nieminen odf Referenced Standard and Year(of Standard) Standard Year ASTM D6878 2011 FM 4470 2012 FM 4474 2011 TAS 114 2011 Equivalence of Product Standards Certified By Sections from the Code https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQWtDgsmFBcODh9XI I cG2... 6/11/2019 F)o -\4-TR1N1-1Yj-ERD [' AT APM61i UCH MENT REQUIREMENTS FORWIN6'00tiO,.'RESI�T kil Table Deck Application Type Description Page la 1A Wood New,Reroof(Tear-Off),Recover C-1 Mechanically Attached Insulation,Bonded Roof Cover 4 1B Wood New,Reroof(Tear-Off),Recover D-1 Insulated,Mechanically Attached Roof Cover 4 1C Wood New,Reroof(Tear-Off),Recover D-3 Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 4 1D Wood New,Reroof(Tear-Off),Recover E-1 Non-Insulated,Mechanically Attached Roof Cover 5 1E Wood New,Reroof(Tear-Off),Recover E-2 Non-Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 5 1F Wood New Construction F Non-Insulated,Bonded Roof Cover 5 2A Steel or Structural Concrete New,Reroof(Tear-Off),Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 6-7 2B Steel or Structural Concrete New,Reroof(Tear-Off),Recover C-1 Mechanically Attached Insulation,Bonded Roof Cover 8-9 2B Steel New,Reroof(Tear-Off),Recover C-2 Mechanically Attached Insulation,Plate-Bonded Roof Cover 10-11 2D Steel or Structural Concrete New,Reroof(Tear-Off),Recover D-1 Insulated,Mechanically Attached Roof Cover 12-15 2E Steel or Structural Concrete New,Reroof(Tear-Off),Recover D-2 Insulated,Mechanically Attached Roof Cover(RUSS Strips) 16 3A Structural Concrete New,Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 17-18 3B Structural Concrete New,Reroof(Tear-Off),Recover C-2 Mechanically Attached Insulation,Plate-Bonded Roof Cover 18-19 3C Structural Concrete New,Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 19 4A LWIC New,Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 20 4A-1 LWIC over Steel New,Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 20 4A-2 LWC over Structural Concrete New,Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 21 5A Gypsum Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 22 6A Various Recover A-1 Bonded Insulation,Bonded Roof Cover 23 6B Steel Recover C-2 Mechanically Attached Insulation,Plate-Bonded Roof Cover 24 6C Steel Recover D-1 Insulated,Mechanically Attached Roof Cover 25 6D Steel or Structural Concrete Recover E Non-Insulated,Mechanically Attached Roof Cover 26 6E Various Recover F-2 New LWC over Existing Roof,Bonded Roof Cover 27 The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Unless otherwise noted,fasteners and stress plates for insulation attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements: > Wood Deck: Mule-Hide Drill Point Fastener or Mule-Hide HDP Fastener with Mule-Hide 3 in.Insulation Plate. Minimum Y.-inch steel penetration,engage the top flute of the steel deck > Steel Deck: Mule-Hide Drill Point Fastener or Mule-Hide HDP Fastener with Mule-Hide 3 in.Insulation Plate. Minimum%-inch steel penetration,engage the top flute of the steel deck. > Structural Concrete: Mule-Hide HDP Fastener or Mule-Hide Fluted Concrete Nail with Mule-Hide 3 in.Insulation Plate.Minimum 1-inch embedment. Fasteners installed with a pilot hole in accordance with the fastener manufacturer's published installation instructions. 3. Unless otherwise noted,insulation may be any one layer or combination of polyisocya nu rate,polystyrene,fiberboard,perlite and/or gypsum-based insulation board that meets the QA requirements of F.A.C.Rule 61G20-3 and is documented as meeting FBC 1505.1 and,for foam plastic,FBC Chapter 26,when installed with the roof cover. 4. Minimum 200 psi,minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type C-2(plate bonded roof cover)or Type D(mechanically attached membrane), whereby the membrane fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater type,thickness and strength to the steel and concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. Exterior Research and Design,LLC.d/b/a Trinity I ERD Evaluation Report M15060.06.09-R5 for FL12772-RS Certificate of Authorization#9503 6'"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 5:09/11/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide TPO-c Single Ply Roof Systems;(608)365-3111 Appendix 1,Page 1 of 27 F)o - TRINITY 1 ERD S. Preliminary insulation attachment for System Type D: Unless otherwise noted,refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29(January 2016). 6. Unless otherwise noted,insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application;the ribbons/beads shall expand as noted in the manufacturer's published instructions: ➢ Mule-Hide Helix°Low-Rise Adhesive(HELIX): Continuous%to 1-inch wide beads,12-inch o.c. ➢ ICP Adhesives CR-20: Continuous 2%to 3'/:-inch wide ribbons,12-inch o.c. ➢ OlyBond 500(OB-500): Continuous Y4 to 1-inch wide ribbons,12-inch o.c.using PaceCart or SpotShot application devices. ➢ Note: When multiple layers(s)of insulation and/or coverboard are installed in ribbon-applied adhesive,adhesive ribbons shall be staggered from layer-to-layer a distance of one-half the ribbon spacing. ➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 7. Unless otherwise noted,all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure(MDP)limitations. In no case shall these values be used to'increase'the MDP listings in the tables;rather if MDP listing below meets or exceeds that listed for a particular system in the tables,then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table: ➢ ICP Adhesives CR-20: MDP -117.5 psf (Min.1.0-inch thick) ➢ OlyBond 500(OB500): MDP -315.5 psf (Min.0.5-inch thick Poly ISO 1,H-Shield or ENRGY 3) ➢ OlyBond 500(08500): MPD -487.5 psf (Min.0.5-inch thick Poly ISO 2 or ACFoam II) 8. Bonded polyisocyanu rate insulation boards shall be maximum 4 x 4 ft. 9. For mechanically attached components or partially bonded insulation,the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD-1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 or Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(January 2016)for Zone 2/3 enhancements. 10. For assemblies with all components fully bonded in place,the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16,and no rational analysis is permitted. 11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 12. For existing substrates in a bonded recover or re-roof installation,the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive,and the existing roof system(for recover)shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction,as documented through field uplift testing in accordance with ANSI/SPRI IA-1,ASTM E907,FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13. For System Type D,steel deck applications,the roof membrane shall be run with its length perpendicular to the steel deck flutes. 14. For Structural Concrete Deck or Recover Applications using System Type C-2 (Plate Bonded Roof Cover) or Type D(Mechanically Attached Roof Cover),the insulation is optional. Alternatively, min.0.5-inch HP Recovery Board,Poly ISO 1-HD,H-Shield HD or SecurShield HD or min.0.25-inch to 0.625-inch Dens Deck,Dens Deck Prime,SECUROCK Gypsum-Fiber Roof Board or SECUROCK Glass-Mat Roof Board or min.3/8-inch Insulfoam R-Tech EPS or Fan-Fold may be used as a separator board,preliminarily attached prior to roof cover installation. The separator component shall be documented as meeting FBC 1505.1 and,for foam plastic, FBC Chapter 26,when installed with the roof cover in Recover applications. 15. Lightweight Insulating Concrete(LWC)shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced,refer to current LWC Product Approval for specific deck construction and limitations. For systems where specific LWC is not referenced,the minimum design mix shall be 300 psi. In all cases,the minimum top-coat thickness is 2-inches. For LWC over structural concrete,reference is made to FBC Section 1917.4.1,Point 1. Exterior Research and Design,U.C.d/b/a Trinity I ERD Evaluation Report M15060.06.09-R5 for FL32772-115 -Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 5:09/11/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide TPO-c Single Ply Roof Systems;(608)365-3111 Appendix 1,Page 2 of 27 __Q-TRINITY RD 16. For adhered membrane systems,side laps shall be minimum 2-inch wide sealed with min.1.5-inch heat weld. Unless otherwise noted,membrane adhesive application rates are as follows: Membrane „ .. Adhesive . Method Rate Mule-Hide TPC-c Mule-Hide TPO-c Bonding Adhesive(TPC-c BA) Contact(both sides) 60 ft'/gal Mule-Hide TPO-c Aqua Base 120 BA Contact(both sides) 120 ftZ/gal Mule-Hide TPO-c Fleece Back Aqua Base 120 BA Wet lay(substrate) 120 ft�/gal Mule-Hide TPO-c Fleece Back Mule-Hide Helix®Low-Rise-Adhesive(HELIX) Wet lay(substrate) FULL=continuous ribbons,maximum 4-inch o.c. 17. For membrane systems attached using TPO 30-inch Pressure-Sensitive RUSS,the underside of the membrane which comes in contact with the tape shall be primed with HP-250 Primer. The membrane shall be secured by placing the primed portion onto the tape portion of the TPO 10-inch Pressure-Sensitive RUSS and roll with a steel hand roller to ensure contact. 18. For bonded membrane systems,unless otherwise noted,reference to"Mule-Hide TPC-c"membrane below also includes"Mule-Hide TPO-c EXTRA". 19. Vapor barrier options for use over structural concrete deck followed by adhesive-applied insulation carry the following Maximum Design Pressure(MDP)limitations. The lesser of the MDP listings below vs.those in Table 3A applies. j:VAPOR BARRIER OPTIONS,,STRUCTURAL CONCRETE DECK,FOLLOWED BY ADHESIVE,!APPLIED INSULATION PERTABLE 3At . _ _... ,...... .. ..,... a.. .._, .. . ...., Option# Primer Type Vapor Barrier Application Insulation Adhesive MDP(psf) VB-1. Carlisle CAV-GRIP Primer F5-Air&Vapor Barrier or Carlisle VapAir Seal 725TR Self-adhering HELIX(RIBBON,12-inch o.c.) -97.5 VB-2. ASTM D41 Carlisle SureMB 90TG Base or SureMB 120 TG Poly Base Torch-applied HELIX(RIBBON,12-inch o.c.) -97.5 VB-3. ASTM D41 Carlisle SureMB 90 Base or SureMB 120 Poly Base Hot-asphalt HELIX(RIBBON,12-inch o.c.) -97.5 20. "MDP"=Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads. Exterior Research and Design,LLC.d/b/a Trinity( ERD Evaluation Report M15060.06.09-RS for FL12772-RS Certificate of Authorization#9503 6"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 5:09/11/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide TPO-c Single Ply Roof Systems;(608)365-3111 Appendix 1,Page 3 of 27 = =TRINITY ERD TA BLE.lA WOOD DECKS NEW.:CONSTRUCTION REROOF{Tear=Off)0,RECOVE0- SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION;BONDED3RO.OR COVER System Deck Base Insulation Layer Top Insulation Layer Roof Cover(Note 16) MDP No. (Note 1) Type Fasteners Attach (Psf) Min.19/32'plywood or (Optional)One or more layers, Min.1.5-inch Poly ISO 1,H-Shield,ACFoam II, 2 Mule-Hide TPO-c/TPO-c BA or Aqua W 1 wood plank any combination,loose laid Poly ISO 2 or ENRGY 3 Note 2 1 per 2 ft Base 120 BA 45.0* -TABLE 16 WOOD DECKS NEW CONSTRUCTION,REROOF(Tear'Off)or RECOVER. r SYSTEM TYPED 11INSULATED;MECHANICALLY ATTACHED ROOF COVER System Insulation Layer(Note 14) Roof Cover MDP No Roof Deck rane Fasteners Spacing (Psfl Min. -' c plywood or wood plank at max.24"spans One or more preliminarilMule-Hide Mule-Hide EHD 6-inch owithin 55-inch wide la W-2 attachy .c. . laps spaced 90.5-inched using 8d ring shank nails spaced 6"o.c.in the field layers,any Fasteners and 2.4 5 5 and#10 ring shank nails spaced 4"o.c.at the perimeter combination attached TPO-c Seam Plates O.C. Outside of lap sealed with 1.5-inch heat-weld Min.19/32-inch plywood or wood pan at max. s or more Mule-Hide EHD W-3 attached using 8d ring shank nails spaced 6"o.c.in the field layers,any preliminarily Mule-Hide Fasteners and 2.4 6-inch tsi within winch wide laps spaced -wee inch -67.5 and#10 ring shank nails spaced 4"o.c.at the perimeter combination attached TPO-c Seam Plates o.c. Outside of lap sealed with 1.5-inch heat weld 6-inch o.c.within 5-inch wide laps spaced 67-inch o.c. Min.23/32-inch OSB at max.24-inch spans attached using One or more Preliminarily Mule-Hide Mule-Hide EHD Outside of lap sealed with 1.5-inch heat-weld and 6- W-4 8d ring shank nails spaced 6"o.c.in the field and 8"o.c.at layers,any attached TPO-c Fasteners and 2.4 inch o.c.in one row centered between the laps. -67.5 intermediate supports combination Seam Plates Center row covered with 6-inch wide cover strip sealed with 1.5-inch heat weld at all edges TABLE 1C W OOD DECKS=NEW CONSTRUCTION,REROOF'(TeAR OF`j oR RECOVER SYSTEM TYPED=3 INSULATEDMECHANICALLYATTACHEDBASE'SHEET;',BONDEDROOFCOVER System Deck(Note 1) Insulation(Note 14) Base Sheet Roof Cover MDP No. Type Attach Base Sheet Fasteners Attach Membrane Adhesive (Psfl Min.19/32-inch plywood at One or more Atlas Summit Mule-Hide Drill Point 12-inch o.c.at the 4-inch laps and 12- Self- W-5 max.24-inch spans;#10 x 2- layers,any Loose-laid Synthetic Fastener and Mule-Hide 2" inch o.c.at three,equally spaced Mule-Hide SA-TPO -120.0 inch wood screws,6-inch o.c. combination Underlayment Seam Plate rows in the center of the sheet. adhered Exterior Research and Design,LLC.d/b/a Trinity) ERD Evaluation Report M15060.06.09-R5 for FL12772-RS Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 5:09/11/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide TPO-c Single Ply Roof Systems;(608)365-3111 Appendix 1,Page 4 of 27 F)o _ - ==T-RINITY- ]_ERD - TABLE 1D WOOD DECKS NEW:�CONSTRUCTIOfV REROOF(Tear-Off)or RECOVERi:. SYSTEM TYPE E Y: NON INSULATED,MECHAN,I,CALLYATTACHED ROOE.COVER Thermal Barrier Roof Cover System Roof Deck Fastener Lap Width Lap Spacing Seam Weld MDP No. Type Attach Membrane Fasteners (PSI (inch) (inch) (inch) (inch) Min.19/32-inch thick Mule-Hide FR Deck Panel A or C or (Optional)Any Mule-Hide EHD Barrier Technology Corp"Blazeguard A or C"at max.24-inch Mule-Hide W-6 spans attached using No.8 x 2'/:-inch long course thread approved Loose-laid TPO c Fasteners and 2.4 12 5 48 1.5 30.0 screws spaced 6"o.c. thermal barrier Seam Plates Min.19/32-inch thick Mule-Hide FR Deck Panel A or C or (Optional)Any Mule-Hide EHD Barrier Technology Corp"Blazeguard A or C"at max.24-inch Mule-Hide W 7 spans attached using No.8 x 2%:-inch long course thread approved Loose-laid TPO-c Fasteners and 2.4 6 5 72 1.5 52.5 screws spaced 6"o.c. thermal barrier Seam Plates Min.19/32-inch thick Mule-Hide FR Deck Panel A or C or (Optional)Any Mule-Hide EHD Barrier Technology Corp"Blazeguard A or C"at max.24-inch Mule-Hide W-8 spans attached using No.8 x 2'/:-inch long course thread approved Loose-laid TPO-c Fasteners and 2.4 6 5 48 1.5 -75.0 screws spaced 6"o.c. thermal barrier Seam Plates Min.19/32-inch plywood at max.24-inch Any inch spans attached Mule-Hide Mule-Hide EHD 48(over W-9 using 8d ring shank nails spaced 6-inch o.c. approved Loose-laid TPO-c Fasteners and 2.4 6 5.5 structural 1.5 -75.0 thermal barrier Seam Plates members) - _. ' TABLE+3E WO.OD DECKS NEW CONSTRUCTION,REROOF;(T EAR OFF)OR RECOVER �. SYSTEM`TYPE E-2 'NON=INSULAIED,'IVIECHIANICALLYATTAC HED BASE,SHEET, O'NOED ROOF COVER' System Deck(Note 1) Thermal Barrier Base Sheet Roof Cover MDP No. Type Attach Base Sheet Fasteners Attach Membrane Adhesive (Psf) Min.19/32-inch plywood at (Optional)Any Atlas Summit Mule-Hide Drill Point 12-inch o.c.at the 4-inch laps and 12-inch W-10 max.24-inch spans;#10 x 2- approved Loose-laid Synthetic Fastener and Mule-Hide o.c,at three,equally spaced rows in the Mule-Hide SA- Self- -120.0 inch wood screws,6-inch o.c. thermal barrier Underlayment 2"Seam Plate center of the sheet. TPO adhered TABLE 1F WOOD DECKS=NEW.CONSTRUCTION T. " SYSTEM TYPE F NON INSULATED,BONDED ROOF COVER System Roof Deck Roof Cover(Note 16) MDP No. Membrane Application (PSI Min.15/32-inch thick Mule-Hide FR Deck Panel A or C or Barrier Technology Corp"Blazeguard A or C"at W-li max.24-inch spans attached using No.8 x 2%-inch long course thread screws spaced 6"o.c. Mule-Hide TPO-c Aqua Base 120 BA 45.0 Min.19/32-inch thick Mule-Hide FR Deck Panel A or C or Barrier Technology Corp`Blazeguard A or C"at W 12 max.24-inch spans attached using No.8 x 2%-inch long course thread screws spaced 6"O.C. Mule-Hide TPO-c Aqua Base 120 BA 52.5 Exterior Research and Design,LLC.d/b/a Trinity I ERD Evaluation Report M15060.06.09-R5 for FL12772-RS Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 5:09/11/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide TPO-c Single Ply Roof Systems;(608)365-3111 Appendix 1,Page 5 of 27 lRIl�! ERD TABLE 2A 11 a iSTEEL or STRUCTURAL CONCRETEDECKS-NEW CONSTRLICTION,.REROOF,(Tear-Off);or RECOVER SYSTEMTYPE B: MECHANICALLY ATTACHED;BASE.-INSULATION'BONDED TOP`INS CATION B NDED , O 1116b COVER;.,. U System Deck Base Insulation Layer Top Insulation Layer MDP Roof Cover(Note 16) No. (Note 1) Type Fastener Attach Type Attach (Psf) MULE-HIDETPO=C APPLICATIONS: . . Min.22 ga.,type B,Grade 33 Min.1.5-inch Poly ISO 1,H- Min.1.0-inch base insulation and/or Mule-Hide SC-1 steel or min.2,500 psi Note 2 1 per 3.2 ft2 Min.0.25-inch Dens Deck Prime or HELIX /TPO-c BA or 120 B Shield -45.0* structural concrete ,Polyiso HP-H SECUROCK Gypsum-Fiber Roof Board Aqua Base 120 BA Min.22 ga.,type B,Grade 33 Min.2-inch PolyISO 1,H- Min.1.0-inch base insulation and/or SC-2 steel or min.2,500 psi Note 2 1 per 4.0 ft2 Min.0.25-inch Dens Deck Prime or HELIX Mule-Hide 120 B/TPO-c BA or -45.0* structural concrete Shield,Polyiso HP-H SECUROCK Gypsum-Fiber Roof Board Aqua Base 120 BA Min.22 ga.,type B,Grade 33 Min.0.5-inch Dens Deck orMin.1.5-inch ACFoam II,Poly ISO 2, Mule-Hide TPO-c/TPO-c BA or SC-3 steel or min.2,500 psi Dens Deck Prime Note 2 1 per 2.0 ft2 ENRGY 3,Poly ISO 1 or H-Shield followed OBSOO Aqua Base 120 BA -37.5* structural concrete by Min.0.25-inch Dens Deck Prime Min.22 ga.,type B,Grade 33 Min.2-inch Poly ISO 1.H- 2 Min 0.25-inch SECUROCK Gypsum-Fiber Mule-Hide TPO-c/TPO-c BA or SC-4 steel or min.2,500 psi Shield,H-Shield CG Note 2 1 per 4.0 ft Roof Board OBSOO Aqua Base 120 BA -37.5* structural concrete Min.22 ga.,type B,Grade 33 Min.1.5-inch ACFoam II,Poly Mule-Hide TPO-c/TPO-c BA or SC-5 steel or min.2,500 psi ISO 1,Poly ISO 2,H-Shield CG, Note 2 1 per 2.0 ft2 Additional layers of base insulation OB500 Aqua Base 120 BA -45.0* structural concrete ENRGY 3 Min.22 ga.,type B,Grade 33 Min.1.5-inch ACFoam Il,Poly SC-6 steel or min.2,500 psi ISO 1,Poly ISO 2,H-Shield CG, Note 2 1 per 2.0 ft2 Min.0.25-inch Dens Deck,Dens Deck OBSOO Mule-Hide /TPO-c BA or 120 B Prime -45.0* structural concrete ENRGY 3 Aqua Base 120 BA Min.22 ga.,type B,Grade 33 Min.0.5-inch Dens Deck or2 Min.1.5-inch ACFoam II,Poly ISO 2, Mule-Hide TPO-c/TPO-c BA or SC-7 steel or min.2,500 psi Dens Deck Prime Note 2 1 per 2.0 ft OB500 ENRGY 3,H-Shield or Poly ISO 1 Aqua Base 120 BA -45.0* structural concrete Min.22 ga.,type B,Grade 33 Min.2.0-inch ACFoam II,Poly SC-8 steel or min.2,500 psi ISO 1,Poly ISO 2,H-Shield CG, Note 2 1 per 4.0 ft2 Additional layers of base insulation 08500 Mule-Hide TPO-c/TPO-c BA or -45.0* structural concrete ENRGY 3 Aqua Base 120 BA Min.22 ga.,type B,Grade 33 Min.2.0-inch ACFoam II,Poly Min.0.25-inch Dens Deck,Dens Deck Mule-Hide TPO-c/TPO-c BA or SC-9 steel or min.2,500 psi ISO 1,Poly ISO 2,H-Shield CG, Note 2 1 per 4.0 ft2 OB500 -45.0* structural concrete ENRGY 3 Prime Aqua Base 120 BA - Min..-22 ga.,type B,Grade 33 - Min.1.5-inch Poly ISO 1,H- 2 Min.0.25-inch SECUROCK Gypsum-Fiber Mule-Hide TPO-c/TPO-c BA or SC-10 steel or min.2,500 psi Shield,H-Shield CG Note 2 1 per 3.2 ftRoof Board OB500 Aqua Base 120 BA -45.0 structural concrete Min.22 ga.,type B,Grade 33 Min.2-inch Poly ISO 1,H- 2 Min 0.25-inch SECUROCK Gypsum-Fiber Mule-Hide TPO-c/TPO-c BA or SC-11 steel or min.2,500 psi Shield,H-Shield CG Note 2 1 per 2.67 ftRoof Board 08500 Aqua Base 120 BA -45.0* structural concrete Min.22 ga.,type B,Grade 33 Min.2-inch Poly I50 1,H- 2 Min 0.25-inch SECUROCK Gypsum-Fiber Mule-Hide TPO-c/TPO-c BA or SC-12 steel min. psi Shield,H-Shield CG Note 2 1 per 1.6 ft Roof Board OBSOO Aqua Base 120 BA 60.0 structural concretcret e MULE=HIDE TPOcC.FLEECE:BACKAPPLICAT10N5 Exterior Research and Design,LLC.d/b/a Trinity ERD Evaluation Report M15060.06.09-R5 for FL12772-R5 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 5:09/11/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide TPO-c Single Ply Roof Systems;(608)365-3111 Appendix 1,Page 6 of 27 F)o ERD JTRINITY TABLE IA:':STE c�SfkrURAL CONCRETEDECKSNEW C6�tf1n"6h,ktk6 Off)or RECOVER ' $YFEWTYOE 3' VECHANICALLY,�TTACHED BA INSULATION'RONDER.T' qFIN-S'U­LA­TIO. N;�- BONPEDR00F.00 VER,, ,-,- System Deck Base Insulation Layer Top Insulation Layer Roof Cover(Note 16) MDP No. (Note 1) Type Fastener Attach Type Attach (psf) Min.22 ga.,type B,Grade 33 Min.1.5-inch Poly ISO 1,H- Min.1.0-inch base insulation and/or Mule-Hide TPO-c Fleece Back/ SC-13 steel or min.2,500 psi Shield,Polyiso HP-H Note 2 1 per 3.2 ft2 Min.0.25-inch Dens Deck Prime or HELIX HELIX(FULL) -45.0* structural concrete SECUROCK Gypsum-Fiber Roof Board Min.22 ga.,type B,Grade 33 min.2-inch Poly ISO 1,H- ft2 Min.1.0-inch base insulation and/or Mule-Hide TPO I-c Fleece Back/ SC-14 steel or min.2,500 psi Shield,Polyiso HP-H Note 2 1 per 4.0 Min.0.25-inch Dens Deck Prime or HELIX HELIX(FULL) -45.0* structural concrete SECUROCK Gypsum-Fiber Roof Board Min.22 ga.,type B,Grade 33 min.2-inch Poly ISO 1,H- 2 Min 0.25-inch SECUROCK Gypsum-Fiber Mule-Hide TPO-c Fleece Back/ ft SC-15 steel or min.2,500 psi Shield,Polyiso HP-H Note 2 1 per 1.6 Roof Board HELIX HELIX(FULL) -60.0 structural concrete Exterior Research and Design,I.I.C.d/b/a Trinity I ERD Evaluation Report M15060.06.09-R5 for FL12772-RS Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 5:09/11/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide TPO-c Single Ply Roof Systems;(608)365-3111 Appendix 1,Page 7 of 27 = __ �f Rll ITY ERD TABLE 26 'STEEL or STRUCTURAL'CONCRETEEW :bECK IU S,NCONSTRUCTIO ,REROOF{Tear-Off)`'or RECOVER SYSTEM rTYPE C.I; MECHANICALLY ATTACHED.INSULATIOIV,BONDED ROOF COVER System Deck Top Insulation Layer MDP Base Insulation Layer Roof Cover(Note 16) No. (Note 1) Type Fasteners Attach (psf) MUIE=HIDETP.O=C`APPLICATIONS `' 7-7 -. Min.1.5"thick,one or more layers, Trufast SIP LD Mule-Hide TPO-c/TPO-c BA or Aqua SC-16 Min.22 ga.,type B,Grade 33 steel any combination,loose laid Min 7/16"APA or TECO rated OSB Fasteners 1 per 3.2 ft2 Base 120 BA 37.5* SC-17 Min.22 ga.,type B,Grade 33 steel or (Optional)One or more layers,any Min.1-inch Poly ISO 2,ACFoam II Note 2 1 per 1.6 ft2 Mule-Hide TPO-c/TPO-c BA or Aqua min.2,500 psi structural concrete combination,loose laid or ENRGY 3 Base 120 BA -37.5* Min.22 ga.,type B,Grade 33 steel or Min.1.5-inch thick,one or more SC-18 min.2,500 psi structural concrete layers,any combination,loose laid Min.0.5-inch H-Shield HD Note 2 1 per 2.67 ft2 Mule-Hide TPO-c/TPO-c BA 37.5* Min.22 ga.,type B,Grade 33 steel or Min.1.5-inch thick,one or more Min 0.25-inch SECUROCK Gypsum- Note 2 1 per 2.67 ft2 Mule-Hide TPO-c/TPO-c BA or Aqua 37.5* SC-19 min.2,500 psi structural concrete layers,an combination,loose laid Fiber Roof Board P Y Y Base 120 BA 2 ft2 SC-20 Min.22 ga.,type B,Grade 33 steel or Min.1.5-inch thick,one or more Min 0.50-inch SECUROCK Gypsum- Note 2 1 Mule-Hide TPO-c/TPO-c BA or Aqua per 3. min.2,500 psi structural concrete layers,any combination,loose laid Fiber Roof Board Base 120 BA 45.0* Min.22 ga.,type B,Grade 33 steel or Min.1.5-inch thick,one or more Min 0.625-inch SECUROCK Mule-Hide TPO-c/TPO-c BA or Aqua SC-21 min.2,500 psi structural concrete layers,an combination,loose laid Gypsum-Fiber Roof Board Note 2 1 per 4.0 ft2 45.0* P Y Y YP Base 120 BA Min.1.5"thick,one or more layers, Trufast SIP LD 1 Mule-Hide TPO-c/TPO-c BA or Aqua SC-22 Min.22 ga.,type B,Grade 33 steel any combination,loose laid Min 7/16"APA or TECO rated OSB Fasteners per 2.67 ft Base 120 BA 45.0* SC-23 Min.22 ga.,type B,Grade 33 steel or One or more layers,any combination, Min 7/16"APA or TECO rated OSB Note 2 1 per 3.6 ft2 Mule-Hide TPO-c/TPO-c BA or Aqua -45.0* min.2,500 psi structural concrete loose laid Base 120 BA SC-24 Min.22 ga.,type B,Grade 33 steel or (Optional)One or more layers,any Min.1-inch Poly ISO 1,H-Shield,H- Note 2 1 per 1.6 ft2 Mule-Hide TPO-c/TPO-c BA or Aqua 45.0* min.2,500 psi structural concrete combination,loose laid Shield CG Base 120 BA Min.22 ga.,type B,Grade 33 steel or (Optional)One or more layers,any Min.1.5-inch ACFoam II,Poly ISO Mule-Hide TPO-c/TPO-c BA or Aqua A SC-25 min.2,500 psi structural concrete combination,loose laid 2,H-Shield,Poly ISO 1,H-Shield Note 2 1 per 2.0 ft2 gale 120 BA q -45.0* CG,ENRGY 3 Min.22 a.,type B,Grade 33 steel or (Optional)One or more layers,an Min.2.0-inch ACFoam II,Poly ISO SC-26 g Yp ( p ) Y y 2,H-Shield,Poly ISO 1,H-Shield Note 2 1 per 4.0 ft2 Mule-Hide TPO-c/TPO-c BA or Aqua * min.2,500 psi structural concrete combination,loose laid P Base 120 BA 45.0 CG,ENRGY 3 Min.22 ga.,type B,Grade 33 steel or Min.1.5-inch thick,one or more SC 27 min.2,500 psi structural concrete layers,any combination,loose laid Min.0.5-inch H-Shield HD Note 2 1 per 2.0 ft2 Mule-Hide TPO-c/TPO-c BA -45.0* Min..22 ga.,type B,Grade 33 steel or Min.1.5"thick,one or more layers, 2 Mule-Hide TPO-c/Aqua Base 120 SC-28 min.2,500 psi structural concrete any combination,loose laid Min 7/16"APA or TECO rated OSB Note 2 1 per 1.9 ft BA 52.5 -- Min.22 ga.,type B,Grade 33 steel or Min.1.5-inch thick,one or more SC-29 min.2,500 psi structural concrete layers,any combination,loose laid Min 0.5-inch Dens Deck Prime Note 2 1 per 1.6 ft2 Mule-Hide TPO-c/TPO-c BA -60.0 Min.22 ga.,type B,Grade 33 steel or Min.1.5"thick,one or more layers, SC-30 min.2,500 psi structural concrete any combination,loose laid Min 7/16"APA or TECO rated OSB Note 2 1 per 1.9 ft2 Mule-Hide TPO-c/TPO-c BA -75.0 Min.22 ga.,type B,Grade 33 steel or (Optional)One or more layers,any Min 2.0-inch ACFoam Il,Poly ISO 1, SC-31 min.2,500 psi structural concrete combination,loose laid Poly ISO 2,H-Shield,H-Shield CG, Note 2 1 per 1.6 ft2 Mule-Hide TPO-c/TPO-c BA -75.0 ENRGY 3 Exterior Research and Design,I.I.C.d/b/a Trinity( ERD Evaluation Report M15060.06.09-R5 for FL12772-R5 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 5:09/11/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide TPO-c Single Ply Roof Systems;(608)365-3111 Appendix 1,Page 8 of 27 F)o -_-TRINITY TABLE . STEEL oirS"T'RU"CT'IJR' AL' ItCONSTRUCTION;' t 6*60jTear-Ofij�6r* R CON RETE DECKS NEW R SYSTEK',,TY -1: MECHANICALLY ATTACHED INSULATION,BCiND,ED:..ROOFCO3VER, System Deck Base Insulation Layer Top Insulation Layer Roof Cover(Note 16) MDP No. (Note 1) Type Fasteners Attach (psf) SC-32 Min.22 ga.,type B,Grade 33 steel or Min.1.5-inch thick,one or more Min 0.5-inch SECUROCK Gypsum- min.2,500 psi structural concrete layers,any combination,loose laid Fiber Roof Board SC-33 Min.22 ga.,type B,Grade 33 steel or Min.1.5-inch thick,one or more Min 7/16-inch APA or TECO rated Note 2 1 per 1 ft2 Mule-.Hide TPO-c TPO-c BA -97.5 min.2,500 psi structural concrete layers,any combination,loose laid OSB Min.20 ga.,type B,Grade 33 steel or (Optional)Min.1.5-inch thick,one or Min.0.625-inch SECUROCK SC-34 min.2,500 psi structural concrete more layers,any combination,loose Gypsum-Fiber Roof Board Note 2 1 per 1.33 ft2 Mule-Hide TPO-c TPO-c BA -112.5 laid SC-35 Min.18 ga.,type B,Grade 33 steel or Min.2-inch thick,one or more layers, Min.0.5-inch SECUROCK Gypsum- min.2,500 psi structural concrete any combination,loose laid Fiber Roof Board SC-36 Min.22 ga.,type B,Grade 33 steel or (Optional)One or more layers,any Min 2-inch H-Shield CG Note 2 1 ft2 min.2,500 psi structural concrete combination,loose laid per 1 Mule-Hide TPO-c TPO-c BA -120.0 MU_LE'=_H'JDE'SA40 AIPPLIcATIO'NS": Min.22 ga.,type B,Grade 33 steel or (Optional for Recover)Min.1.5-inch SC-37 min.2,500 psi structural concrete thick,one or more layers,any Min.2-inch Insulfoam SP Note 2 1 per 2.7 ft' Mule-Hide SA-TPO,self-adhered -30.0* combination,loose laid Min.22 ga.,type B,Grade 33 steel or (Optional for Recover)Min.1.5-inch SC-38 min.2,500 psi structural concrete thick,one or more layers,any Min.2-inch Insulfoam SP Note 2 1 per 2.0 ft2 Mule-Hide SA-TPO,self-adhered -45.0* combination,loose laid (Optional for Recover)Min.1.5-inch Min.0.25-inch Dens Deck Prime or SC-39 Min.22 ga.,type B,Grade 33 steel or thick,one or more layers,any SECUROCK Gypsum-Fiber Roof Note 2 1 per 2.0 ft2 Mule-Hide SA-TPO,self-adhered -45.0* combination,loose laid min.2,500 psi structural concrete Board or min 7/16-inch APA or TECO rated OSB Min.22 ga.,type B,Grade 33 steel or (Optional)Min.1.5-inch thick,one or Min.1.5-inch Poly ISO 1,H-Shield, SC-40 min.2,500 psi structural concrete more layers,any combination,loose Polyiso HP-H,SecurShield,H-Shield Note 2 1 per 2.0 ft2 Mule-Hide SA-TPO,self-adhered -45.0* laid CG Min.22 ga.,type B,Grade 33 steel or (Optional)Min.1.5-inch thick,one or Min.2.0-inch Poly ISO 1,H-Shield, SC-41 min.2,500 psi structural concrete more layers,any combination,loose Polyiso HP-H,SecurShield,H-Shield Note 2 1 per 1.6 ft2 Mule-Hide SA-TPO,self-adhered -60.0 laid CG Exterior Research and Design,I.I.C.d/b/a Trinity ERD Evaluation Report M15060.06.09-R5 for FL12772-R5 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 5:09/11/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide TPO-c Single Ply Roof Systems;(608)365-3111 Appendix 1,Page 9 of 27 F)o ER® N4 7- RINITY TeA6;0 ] orRECOVER ­ AilLi "NEW CONSTRUCTION;;, REROOF ff '21 SYSTEM E, -2-*VIECHANICALLYATTACHER�,INS INSULATION,PLATE BONDED OF'COVER System Deck Insulation Layer Attachment Roof Cover MDP No. (Note 1) Fasteners Density (Psf) Min.22 ga.,type B, Min.1-inch thick,one or more Mule-Hide EHD Fastener and I per 5.33 ft'(6 per 4 x 8 ft board) Mule-Hide TPO-c bonded to RhinoBond Plate-TPO or SC-42 Grade 33 steel layers,any combination.Note RhinoBond Plate-TPO or Per FM Loss Prevention Data Sheet 1-29; RhinoBond Treadsafe Plate-TPO with RHINOBOND tool -45.0 A. RhinoBond Treadsafe Plate-TPO Note B per manufacturer's instructions. Min.22 ga.,type B, Min.1-inch thick,one or more Mule-Hide EHD Fastener and 1 per 4 ft2(8 per 4 x 8 ft board) Mule-Hide TPO-c bonded to RhinoBond Plate-TPO or SC-43 Grade 33 steel layers,any combination. Note RhinoBond Plate-TPO or Per FM Loss Prevention Data Sheet 1-29; RhinoBond Treadsafe Plate-TPO with RHINOBOND tool -52.5 A. RhinoBond Treadsafe Plate-TPO Note B per manufacturer's instructions. Min.22 ga.,type B, Mule-Hide EHD Fastener and Mule-Hide TPO-c(minimum 60-mil)bonded to SC-44 Grade 40 steel;6 ft Min.1.5-inch thick,one or RhinoBond Plate-TPO or 1 per 4 ft2 RHINOBOND Insulation Plate(TPO)or RHINOBOND -52.5 spans;5/8"puddle more layers,any combination. RhinoBond Treadsafe Plate-TPO (2 x 2 ft grid pattern) TreadSafe Plate(TPO)with RHINOBOND tool per welds 6"o.c. manufacturer's instructions. Min.22 ga.,type B, Min.1-inch thick,one or more Mule-Hide EHD Fastener and 1 per 4 ft'(8 per 4 x 8 ft board) Mule-Hide TPO-c bonded to RhinoBond Plate-TPO or SC-45 Grade 80 steel layers,any combination. Note RhinoBond Plate-TPO or Per FM Loss Prevention Data Sheet 1-29; RhinoBond Treadsafe Plate-TPO with RHINOBOND tool -60.0 A. RhinoBond Treadsafe Plate-TPO Note B per manufacturer's instructions. Min.22 ga.,type B, Min.1.5-inch thick,one or Mule-Hide EHD Fastener and I per 2 It'(16 per 4 x 8 ft board) Mule-Hide TPO-c bonded to RhinoBond Plate-TPO or SC-46 Grade 33 steel more layers,any combination. RhinoBond Plate-TPO or Per FM Loss Prevention Data Sheet 1-29 RhinoBond Treadsafe Plate-TPO with RHINOBOND tool -97.5 Note C. RhinoBond Treadsafe Plate-TPO per manufacturer's instructions. Min.1.5-inch thick,one or Mule-Hide EHD Fastener and Mule-Hide TPO-c(minimum 60-mil)bonded to SC-47 Min.22 ga.,type B, more layers,any combination, RhinoBond Plate-TPO or 12-inch o.c.in rows 120-inch o.c. RhinoBond Plate-TPO or RhinoBond Treadsafe Plate- -30.0 Grade 80 steel prelim attach(Note 14) RhinoBond Treadsafe Plate-TPO TPO with RHINOBOND tool per manufacturer's instructions. Min.22 ga.,type B, Min.1.5-inch thick,one or Mule-Hide EHD Fastener and Mule-Hide TPO-c bonded to RhinoBond Plate-TPO or SC-48 Grade 80 steel more layers,any combination, RhinoBond Plate-TPO or 6-inch o.c.in rows 120-inch o.c. RhinoBond Treadsafe Plate-TPO with RHINOBOND tool -37.5 prelim attach(Note 14) RhinoBond Treadsafe Plate-TPO per manufacturer's instructions. Min.22 ga.,type B, Min.1.5-inch thick,one or Mule-Hide EHD Fastener and Mule-Hide TPO-c bonded to RhinoBond Plate-TPO or SC-49 Grade 80 steel more layers,any combination, RhinoBond Plate-TPO or 12-inch o.c.in rows 60-inch o.c. RhinoBond Treadsafe Plate-TPO with RHINOBOND tool -37.5 prelim attach(Note 14) RhinoBond Treadsafe Plate-TPO per manufacturer's instructions. Min.1.5-inch thick,one or Mule-Hide EHD Fastener and Mule-Hide TPO-c(minimum 60-mil)bonded to SC-50 Min.22 ga.,type B, more layers,any combination, RhinoBond Plate-TPO or 12-inch o.c.in rows 60-inch o.c. RhinoBond Plate-TPO or RhinoBond Treadsafe Plate- Grade 80 steel TPO with RHINOBOND tool per manufacturer's -45.0 prelim attach(Note 14) RhinoBond Treadsafe Plate-TPO instructions. Min.1.5-inch thick,one or Mule-Hide EHD Fastener and Mule-Hide TPO-c(minimum 60-mil)bonded to SC-51 Min.22 ga.,type B, more layers,any combination, RhinoBond Plate-TPO or 6-inch o.c.in rows 120-inch o.c. RhinoBond Plate-TPO or RhinoBond Treadsafe Plate- -52.5 Grade 80 steel prelim attach(Note 14) RhinoBond Treadsafe Plate-TPO TPO with RHINOBOND tool per manufacturer's instructions. Exterior Research and Design,LLC.d/b/a Trinity I ERD Evaluation Report M15060.06.09-R5 for FL12772-RS Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 5:09/11/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide TPO-c Single Ply Roof Systems;(608)365-3111 Appendix 1,Page 30 of 27 F)o - = -=TRINITY ERD TABLE:2C STE EL DECKS;=NEW CONSTRUCTIONjAEROOF.(Tear-Off)or RECOVER SYSTEM TYPE C 2 MECHANICALLY ATTACHED INSULATION,PLATE BONDED ROOF COVER System Deck Insulation Layer Attachment Roof Cover MDP No. (Note 1) Fasteners Density (psf) Min.22 ga.,type B, Min.1.5-inch thick,one or Mule-Hide EHD Fastener and Mule-Hide TPO-c bonded to RhinoBond Plate-TPO or SC-52 Grade 80 steel more layers,any combination, RhinoBond Plate-TPO or 6-inch o.c.in rows 60-inch o.c. RhinoBond Treadsafe Plate-TPO with RHINOBOND tool -67.5 prelim attach(Note 14) RhinoBond Treadsafe Plate-TPO per manufacturer's instructions. Notes: A. For these assemblies,the 8 ft insulation board length is placed perpendicular to the steel deck ribs. B. The plate/fastener combination offset 12 inch from adjacent rows. C. For these assemblies,the 8 ft insulation board length is placed perpendicular to the steel deck ribs and each row of insulation is staggered by 1 foot. Exterior Research and Design,I.I.C.d/b/a Trinity) ERD Evaluation Report M15060.06.09-R5 for FL12772-R5 Certificate of Authorization#f9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 5:09/11/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide TPO-c Single Ply Roof Systems;(608)365-3111 Appendix 1,Page 11 of 27 TC)o ABLE 2D: STEEL or,STRUCTURAL CONCRETE:DECKS-'NEW CONSTRUCTION;REROOF(Tear Off)or RECOVER SYSTEM TYPER71_-,!NS ULATED,MECHANICALLY ATTACHED ROOF COVER x Insulation Layer(Note 14) Roof Cover System MDP Roof Deck Fastener Spacing Lap Width Lap Spacing Seam Weld No. Type Attach Membrane Fasteners (psf) (inch) (inch) (inch) (inch) Min.22 ga.,type B,Grade Min.1.5-inch,one or Prelim. Mule-Hide TPO-c Mule-Hide EHD Fastener and Mule-Hide SC-53 80 steel more layers,any attach or TPO-c EXTRA 2.4"Seam Plate 18 5.5 66.5 1.5 -30.0 combination Min.22 ga.,type B,Grade Min.1.5-inch,one or Prelim. Mule-Hide TPO-c Mule-Hide EHD Fastener(steel only)or SC-54 33 steel or min.2,500 psi more layers,any HDP Fastener(concrete only)and Mule- 12 5.5 138.5 1.5 -30.0 structural concrete combination attach or TPO-c EXTRA Hide 2.4"Seam Plate Min.22 ga.,type B,Grade Min.1.5-inch,one or Prelim. Mule-Hide TPO-c Mule-Hide EHD Fastener(steel only)or SC-55 33 steel or min.2,500 psi more layers,any HDP Fastener(concrete only)and Mule- 12 5.5 91 1.5 -30.0 structural concrete combination attach or TPO-c EXTRA Hide 2.4"Seam Plate Min.22 ga.,type B,Grade Min.1-inch,one or 33 steel,6 ft span,5/8" more layers,any diameter puddle welds 6" combination(optional Prelim. Mule-Hide TPO-c Mule-Hide EHD Plus Fasteners and SC-56 o.c.,side laps secured 24" for recover)followed attach or TPO-c EXTRA Mule-Hide 2.4" PLUS Seam Plate 12 5.5 90.5 1.5 30.0 o.c.w/YV-14x1"long self- by 3/8-inch Insulfoam tapping hex-head screw R-Tech EPS or Fan-Fold Min.22 ga.,type B,Grade 33 steel,6 ft span,5/8" Mule-Hide TPO-c Min.1-inch,one or diameter puddle welds 6" Prelim. (min.nominal 60- Mule-Hide EHD Plus Fasteners and SC-57 o.c.,side laps secured 24" combination more layers,any Attach mil)or TPO-c Mule-Hide 2.4" PLUS Seam Plate 12 5.5 90.5 1.5 37.5 o.c.w/'/<"-14x1"long self- EXTRA tapping hex-head screw Min.22 ga.,type B,Grade Min.1.5-inch,one or Prelim. Mule-Hide TPO-c Mule-Hide EHD Fastener(steel only)or SC-58 80 steel or min.2,500 psi more layers,any HDP Fastener(concrete only)and Mule- 12 5.5 115 1.5 -37.5 structural concrete combination attach or TPO-c EXTRA Hide 2.4"Seam Plate Min.22 ga.,type B,Grade 40 steel;6 ft spans;5/8" Min.1-inch,one or prelim. Mule-Hide TPO-c Mule-Hide EHD Fastener(steel only)or SC-59 puddle welds 6"o.c.or more layers,any (min.60-mil)or HDP Fastener(concrete only)Fasteners 6. 5.5 138.5 1.5 -37.5 min.2,500 psi structural combination attach TPO-c EXTRA and Mule-Hide 2.4"Seam Plate concrete Min.22 ga.,type B,Grade 33 steel,6 ft span,5/8" Min.1-inch,one or diameter puddle welds 6" Prelim. Mule-Hide TPO-c Mule-Hide EHD Fastener and Mule-Hide SC-60 o.c.,side laps secured 24" more layers,any attach or TPO-c EXTRA 2.4"Seam Plate 6 5.5 138.5 1.5 45.0 o.c.w/Y4"-14x1"long self- combination tapping hex-head screw Exterior Research and Design,I.I.C.d/b/a Trinity) ERD Evaluation Report M15060.06.09-R5 for FL12772-R5 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 5:09/11/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide TPO-c Single Ply Roof Systems;(608)365-3111 Appendix 1,Page 12 of 27 F)o _ TRINITY- ERL1 ".TABLE'2D: STEEL or.STRUCTURAL CONC.RETE.DECKS-NEW CONSTRUCTION,;REROOF(Tear Off}or RECOVER 44 SYSTEM TYPED 1 :`,INSULATED,MECHANICALLY ATTACHED:ROOF:COVER Insulation Layer(Note 14) Roof Cover System MDP Roof Deck Fastener Spacing Lap Width Lap Spacing Seam Weld No. Type Attach Membrane Fasteners inch inch inch (inch) (psfl Mule-Hide EHD Plus Fasteners and Min.22 ga.,type B,Grade Min. inch,one or Prelim. Mule-Hide TPO-c Mule-Hide 2.4" PLUS Seam Plate(steel SC-61 80 steel min.2,500 psi more layers,any attach or TPO-c EXTRA only)or HDP Fastener and Mule-Hide 12 5.5 115 1.5 45.0 structurall concrete combination 2.4"Seam Plates Min.18 ga.,type B,Grade Min.1.5-inch,one or Prelim. Mule-Hide TPO-c Mule-Hide EHD Fasteners(steel only)or SC-62 33 steel or min.2,500 psi more layers,any attach or TPO-c EXTRA HDP Fastener(concrete only)and Mule- 12 5.5 115 1.5 -45.0 structural concrete combination Hide 2.4"Seam Plates Min.22 ga.,type B,Grade 33 steel,6 ft span,5/8" Mule-Hide TPO-c Min.1-inch,one or diameter puddle welds 6" Prelim. (min.nominal 60- Mule-Hide EHD Fastener and Mule-Hide SC-63 o.c.,side laps secured 24" combination more layers,any attach mil)or TPO-c 2.4"Seam Plate 6 5.5 114.5 1.5 45.0 o.c.w/'/<"-14x1"long self- EXTRA tapping hex-head screw Min.22 ga.,type B,Grade Min.1.5-inch,one or Prelim. Mule-Hide TPO-c Mule-Hide EHD Fastener(steel only)or SC-64 80 steel or min.2,500 psi more layers,any HDP Fastener(concrete only)and Mule- 12 5.5 114.5 1.5 -45.0 structural concrete combination attach or TPO-c EXTRA Hide 2.4"Seam Plate Mule-Hide EHD Plus Fasteners and Min.22 ga.,type B,Grade Min. inch,one or Prelim. Mule-Hide TPO-c Mule-Hide 2.4" PLUS Seam Plate(steel SC-65 t steel l min. to psi more layers,any attach or TPO-c EXTRA only)or HDP Fastener and Mule-Hide 12 5.5 91 1.5 45.0 structural concrete combination 2.4"Seam Plates Min.22 ga.,type B,Grade Min.1.5-inch,one or Prelim. Mule-Hide TPO-c Mule-Hide EHD Fastener(steel only)or SC-66 80 steel or min.2,500 psi more layers,any HDP Fastener(concrete only)and Mule- 12 5.5 91 1.5 -45.0 structural concrete combination attach or TPO-c EXTRA Hide 2.4"Seam Plate Min.22 ga.,type B,Grade 33 steel,6 ft span,5/8" Min.1-inch,one or diameter puddle welds 6" Prelim. Mule-Hide TPO-c Mule-Hide EHD Fastener and Mule-Hide SC-67 o.c.,side laps secured 24"% more layers,any attach or TPO-c EXTRA 2.4"Seam Plate 6 5.5 66.5 1.5 45.0 combination o.c.w/ "-14x1"long self- tapping hex-head screw Min.22 ga.,type B,Grade 33 steel,6 ft span,5/8" Mule-Hide TPO-c Min.1-inch,one or diameter puddle welds 6" Prelim. (min.nominal 60- Mule-Hide EHD Plus Fasteners and SC-68 o.c.,side laps secured 24" combination more layers,any attach mil)or TPO-c Mule-Hide 2.4" PLUS Seam Plate 6 5.5 114.5 1.5 52.5 o.c.w/'/<"-14x1"long self- EXTRA tapping hex-head screw Min.22 ga.,type B,Grade Min.1.5-inch,one or Prelim. Mule-Hide TPO-c SC-69 40 steel;6 ft spans;5/8' more layers,an min.60-mil or Mule-Hide EHD Fastener and Mule-Hide p y y attach ( ) 2.4"Seam Plate 6 5.5 114.5 1.5 -52.5 puddle welds 6"o.c. combination TPO-c EXTRA Exterior Research and Design,I.I.C.d/b/a Trinity I ERD Evaluation Report M15060.06.09-R5 for F1.12772-115Certificate of Authorization#19503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 5:09/11/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide TPO-c Single Ply Roof Systems;(608)365-3111 Appendix 1,Page 13 of 27 -- = -TRINITYIERD TABLE 2D STEEL qr STRUCTURAL CONCRETE DECKS-NEW.:CONSTRUCTION;REROOF,(Tear Off).or RECOVER SYSTEM,TYPE D 1 INSULATED,MECHANICALLY ATTACHED ROOF;COVER ,. ,._ ... Insulation Layer(Note 14) Roof Cover SyNtoem Roof Deck Fastener Spacing Lap Width Lap Spacing Seam Weld MDP Type Attach Membrane Fasteners (inch) (inch) (inch) (inch) (psf) Min.22 ga.,type B,Grade Min.1.5-inch,one or Prelim. Mule-Hide TPO-c Mule-Hide EHD Fastener(steel only)or SC-70 33 steel or min.2,500 psi more layers,any HDP Fastener(concrete only)and Mule- 6 5.5 138.5 1.5 -52.5 structural concrete combination attach or TPO-c EXTRA Hide 2.4"Seam Plate Min.22 ga.,type B,Grade Min.1.5-inch,one or Prelim. Mule-Hide TPO-c Mule-Hide EHD Fastener(steel only)or SC-71 33 steel or min.2,500 psi more layers,any HDP Fastener(concrete only)and Mule- 6 5.5 91 1.5 -52.5 structural concrete combination attach or TPO-c EXTRA Hide 2.4"Seam Plate Min.22 ga.,type B,Grade 33 steel,6 ft span,5/8" Min.1-inch,one or diameter puddle welds 6" Prelim. Mule-Hide TPO-c Mule-Hide EHD Fastener and Mule-Hide SC-72 o.c.,side laps secured 24" more layers,any attach or TPO-c EXTRA 2.4"Seam Plate 6 5.5 90.5 1.5 52.5 o.c.w/%"-14x1"long self- combination tapping hex-head screw Min.22 ga.,type B,Grade Min.1.5-inch,one or Prelim. Mule-Hide TPO-c Mule-Hide EHD Fastener(steel only)or SC-73 33 steel or min.2,500 psi more layers,any HDP Fastener(concrete only)and Mule- 12 5.5 42.5 1.5 -52.5 structural concrete combination attach or TPO-c EXTRA Hide 2.4"Seam Plate Min.22 ga.,type B,Grade Min.1-inch,one or 33 steel,6 ft span,5/8" more layers,any SC-74 diameter puddle welds 6" combination(optional Prelim. Mule-Hide TPO-c Mule-Hide EHD Fastener and Mule-Hide o.c.,side laps secured 24" for recover)followed attach or TPO-c EXTRA 2.4"Seam Plate 6 5.5 138.5 1.5 60.0 o.c.w/'/<"-14x1"long self- by 3/8-inch Insulfoam tapping hex-head screw R-Tech EPS or Fan-Fold Mule-Hide EHD Plus Fasteners and Min.22 ga.,type B,Grade Min. inch,one or Prelim. Mule-Hide TPO-c Mule-Hide 2.4" PLUS Seam Plate(steel SC-75 t steel l min.2,500 psi more layers,any attach or TPO-c EXTRA only)or HDP Fastener and Mule-Hide 6 5.5 138.5 1.5 60.0 structural concrete combination 2.4"Seam Plates Min.22 ga.,type B,Grade Min.1.5-inch,one or Prelim. Mule-Hide TPO-c Mule-Hide EHD Fastener(steel only)or SC-76 80 steel or min.2,500 psi more layers,any HDP Fastener(concrete only)and Mule- 6 5.5 138.5 1.5 -60.0 structural concrete combination attach or TPO c EXTRA Hide 2.4"Seam Plate Min.1.5-inch,one or - Min.22 ga.,type B,Grade more layers,any Loose Mule-Hide TPO-c Mule-Hide EHD Fastener(steel only)or SC-77 33 steel or min.2,500 psi combination followed laid or TPO-c EXTRA HDP Fastener(concrete only)and Mule- 6 5.5 91 1.5 -60.0 structural concrete by 3/8-inch Insulfoam Hide 2.4"Seam Plate R-Tech EPS Min.22 ga.,type B,Grade Min.1.5-inch,one or Prelim. Mule-Hide TPO-c Mule-Hide EHD Fastener(steel only)or SC-78 33 steel or min.2,500 psi more layers,any HDP Fastener(concrete only)and Mule- 12 5.5 54.5 1.5 -60.0 structural concrete combination attach or TPO-c EXTRA Hide 2.4"Seam Plate Exterior Research and Design,I.I.C.d/b/a Trinity) ERD Evaluation Report M15060.06.09-R5 for FL12772-RS Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 5:09/11/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide TPO-c Single Ply Roof Systems;(608)365-3111 Appendix 1,Page 14 of 27 -Q-TRINITYIERD TABLE 2D:'STEE4 or STRUCTURAL CONCRETE_DECKS.'—NEW CONSTRUCTION;REROOF(Tear Off).or RECOVER SYSTEM TYPED 1,:;INSULATE6,MECHANICALLY ATTACHED ROOF COVER �. . ... . Insulation Layer(Note 14) Roof Cover System Roof Deck Fastener Spacing Lap Width Lap Spacing Seam Weld MDP No. Type Attach Membrane Fasteners (psf) (inch) (inch) (inch) (inch) Min.22 ga.,type B,Grade Min.1.5-inch,one or Prelim. Mule-Hide TPO-c Mule-Hide EHD Fastener(steel only)or SC-79 33 steel or min.2,500 psi more layers,any HDP Fastener(concrete only)and Mule- 6 5.5 90.5 1.5 -67.5 structural concrete combination attach or TPO-c EXTRA Hide 2.4"Seam Plate Min.22 ga.,type B,Grade Min.1.5-inch,one or Prelim. Mule-Hide TPO-c Mule-Hide EHD Fastener(steel only)or SC-80 80 steel or min.2,500 psi more layers,any HDP Fastener(concrete only)and Mule- 9 5.5 54.5 1.5 -75.0 structural concrete combination attach or TPO-c EXTRA Hide 2.4"Seam Plate Min.22 ga.,type B,Grade Min.1.5-inch,one or Prelim. Mule-Hide TPO-c Mule-Hide EHD Fastener(steel only)or SC-81 33 steel or min.2,500 psi more layers,any HDP Fastener(concrete only)and Mule- 6 5.5 42.5 1.5 -82.5 structural concrete combination attach or TPO-c EXTRA Hide 2.4"Seam Plate Min.22 ga.,type B,Grade Min.1.5-inch,one or Prelim. Mule-Hide TPO-c Mule-Hide EHD Fastener(steel only)or SC-82 80 steel or min.2,500 psi more layers,any HDP Fastener(concrete only)and Mule- 6 5.5 54.5 1.5 -90.0 structural concrete combination attach or TPO-c EXTRA Hide 2.4"Seam Plate one or Min.22 ga.,type B,Grade Min.1.5-inch, Prelim. Mule-Hide TPO-c Mule-Hide EHD Fastener and Mule-Hide SC-83 80 steel more layers,any attach or TPO-c EXTRA 2.4"Seam Plate 6 5.5 42.5 1.5 -112.5 combination Exterior Research and Design,I.I.C.d/b/a Trinity I ERD Evaluation Report M15060.06.09-R5 for FL12772-R5 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 5:09/11/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide TPO-c Single Ply Roof Systems;(608)365-3111 Appendix 1,Page 15 of 27 F)o - _--_ _=TRINITY ERD TABLE 2E:'STEEL or STRl1C1 URAL CONCRETE DECKS NEW;CONSTRUC TION,'REROOF'(Tear,Off),or RECOVER . SYSTEM;TYPE D-2:`INSULATED,,MECHANICALLY ATTACHED ROOF:000ER.(RUS$Strips) System Deck Insulation Roof Cover MDP No. Type Attach Membrane Fasteners Attachment (PA Min.22 ga.,type B, Mule-Hide EHD Fastener(steel TPO 10-inch Pressure-Sensitive RUSS strips are applied over the insulation layers,any Grade 80 steel or miOne or more Mule-Hide n. Prelim. only)or HDP Fastener(concrete spaced 138-inch o.c. The plates are centered over each strip and fastened 6 SC-84 2,500 psi structural combination EXTRA attached EXTRA c or TPO-c only)and Mule-Hide 2.4"Seam inch o.c. Roof cover adhered to each strip by first priming with TPO Tape -30.0 concrete Plates Primer at the strip location,then rolling into place with a hand roller. Min.22 ga.,type B, Mule-Hide EHD Fastener(steel TPO 10-inch Pressure-Sensitive RUSS strips are applied over the insulation Grade 80 steel or miOne or more Mule-Hide n. Prelim. only)or HDP Fastener(concrete spaced 114-inch o.c. The plates are centered over each strip and fastened 6- SC-85 layers,any TPO-c or TPO-c -45.0 2,500 psi structural combination attached EXTRA only)and Mule-Hide 2.4"Seam inch o.c. Roof cover adhered to each strip by first priming with TPO Tape concrete Plates Primer at the strip location,then rolling into place with a hand roller. Min.22 ga.,type B, One or more Mule Hide Mule-Hide EHD Fastener(steel TPO 30-inch Pressure-Sensitive RUSS strips are applied over the insulation Grade 80 steel or min. Prelim. only)or HDP Fastener(concrete spaced 90-inch o.c. The plates are centered over each strip and fastened 6- SC-86 2,500 psi structural layersany attached TPO-c or TPO-c only)and Mule-Hide 2.4"Seam inch o.c. Roof cover adhered to each strip by first priming with TPO Tape -52.5 concrete combination EXTRA Plates Primer at the strip location,then rolling into place with a hand roller. Min.22 ga.,type B, Mule-Hide EHD Fastener(steel TPO 30-inch Pressure-Sensitive RUSS strips are applied over the insulation layers,any Grade 80 steel or miOne or more Mule-Hide n. Prelim. only)or HDP Fastener(concrete spaced 120-inch o.c. The plates are centered over each strip and fastened 6- SC-87 2,500 psi structural combination EXTRA attached EXTRA C or TPO-c only)and Mule-Hide 2.4"Seam inch o.c. Roof cover adhered to each strip by first priming with HP-250 60.0 concrete Plates Primer at the strip location,then rolling into place with a hand roller. Min.22 ga.,type B, Mule-Hide EHD Fastener(steel TPO 10 inch Pressure-Sensitive RUSS strips are applied over the insulation Grade 80 steel or min. One or more Prelim. Mule Hide only)or HDP Fastener(concrete spaced 60-inch o.c. The plates are centered over each strip and fastened 12- SC-88 layers,any TPO-c or TPO-c -60.0 2,500 psi structural combination attached EXTRA only)and Mule-Hide 2.4"Seam inch o.c. Roof cover adhered to each strip by first priming with HP-250 concrete Plates Primer at the strip location,then rolling into place with a hand roller. Exterior Research and Design,LLC.d/b/a Trinity I ERD Evaluation Report M15060.06.09-R5 for FL12772-RS Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 5:09/11/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide TPO-c Single Ply Roof Systems;(608)365-3111 Appendix 1,Page 16 of 27 F)o TR1NI 1 ERD TABLE,3A:_STRUCTURAL CONCRETE DECKS-NEW CC)NSTRU,CTION oe`REROONTEAR=OFF) SYSTEM TYPE A=1 BONDED INSULATI ON;BONDED ROOF,COVER;, REFER TO,NOTE19 FOR VAPOR BARRIER OPTIONS System Roof Deck Base Insulation Layer Top Insulation Layer Roof Cover(Note 16) MDP No. (Note 1) Type Attach Type Attach Membrane Application (pso MULE-HIDETP,0-Ci4PPLICATIONS + _ (Optional)Min.1.5-inch Poly ISO 1,H-Shield, structural concrete C-1. Min. upsi Polyiso HP-H,Poly ISO 2,ACFoam II,H-Shield HELIX Min.0.25-inch Dens Deck Prime HELIX Mule-Hide TPO-c Aqua Base 120 BA -127.5 structural CG,SecurShield Min.2,500 psi Min.1.5-inch Poly ISO 1,H-Shield,Polyiso HP-H, C 2. structural concrete Poly 150 2,ACFoam II,H-Shield CG,SecurShield HELIX (Optional)Additional layers of base insulation HELIX Mule-Hide TPO-c Aqua Base 120 BA 127.5 Min.2,500 psi (Optional)Min.1.5-inch Poly ISO 1,H-Shield, C-3. structural concrete Polyiso HP-H,Poly ISO 2,ACFoam 11,H-Shield HELIX Min.0.25-inch Dens Deck Prime HELIX Mule-Hide TPO-c TPO-c BA -195.0 CG,SecurShield Min.2,500 psi (Optional)Min.1.5-inch Poly ISO 1,H-Shield, Min.0.25-inch Dens Deck Prime or SECUROCK TPO-c BA or Aqua C-4. structural concrete Polyiso HP-H,Poly ISO 2,ACFoam II,H-Shield HELIX Gypsum-Fiber Roof Board HELIX Mule-Hide TPO-c Base 120 BA -195.0 CG,SecurShield Min.2,500 psi Min.1.5-inch Poly ISO 1,H-Shield,Polyiso HP-H, C-5. structural concrete Poly ISO 2,ACFoam Il,H-Shield CG,SecurShield HELIX (Optional)Additional layers of base insulation HELIX Mule-Hide TPO-c TPO-c BA 232.5 Min.2,500 psi Min.1.5-inch ACFoam 11,H-Shield,ENRGY 3 or C-6. structural concrete Poly ISO 1,Poly ISO 2 CR-20 (Optional)Additional layers of base insulation CR-20 Mule-Hide TPO-c Aqua Base 120 8A 127.5 Min.2,500 psi (Optional)Min.1.5-inch ACFoam 11,H-Shield, C-7. structural concrete ENRGY 3 or Poly ISO 1,Poly ISO 2 CR-20 Min.Y.-inch Dens Deck or Dens Deck Prime CR-20 Mule-Hide TPO-c Aqua Base 120 BA 127.5 Min.2,500 psi Min.1.5-inch ACFoam 11,H-Shield,ENRGY 3 or C 8. structural concrete Poly ISO 1,Poly ISO 2 CR-20 (Optional)Additional layers of base insulation CR-20 Mule-Hide TPO-c TPO-c BA 232.5 Min.2,500 psi (Optional)Min.1.5-inch ACFoam II,H-Shield, C 9' structural concrete ENRGY 3 or Poly ISO 1,Poly ISO 2 CR-20 Min./<-inch Dens Deck or Dens Deck Prime CR-20 Mule-Hide TPO-c TPO-c BA 232.5 Min.2,500 psi Min.0.25-inch SECUROCK Gypsum-Fiber Roof C 10. structural concrete Min.1.5-inch Poly ISO 1,H-Shield,H-Shield CG OB500 Board OB500 Mule-Hide TPO-c TPO-c BA 120.0 Min.2,500 psi Min.1.5-inch ACFoam II,H-Shield,ENRGY 3 or C-11. structural concrete Poly ISO 1,Poly ISO 2 OB500 (Optional)Additional layers of base insulation 08500 Mule-Hide TPO-c Aqua Base 120 BA 127.5 — Min-2,500 psi_ (Optional)Min.1.5-inch ACFoam 11,H-Shield, C 12. structural concrete ENRGY 3 or Poly ISO 1,Poly ISO 2 OB500 Min.Y.-inch Dens Deck or Dens Deck Prime OB500 Mule-Hide TPO-c Aqua Base 120 BA 127.5- - Min.2,500 psi Min.1.5-inch ACFoam 11,H-Shield,ENRGY 3 or C-13. structural concrete Poly ISO 1,Poly ISO 2 OB500 (Optional)Additional layers of base insulation OB500 Mule-Hide TPO-c TPO-c BA 150.0 Min.2,500 psi (Optional)Min.1.5-inch ACFoam 11,H-Shield, C 14. structural concrete ENRGY 3 or Poly ISO 1,Poly ISO 2 OB500 Min.Y4-inch Dens Deck or Dens Deck Prime OB500 Mule-Hide TPO-c TPO-c BA 150.0 Min.2,500 psi Min.0.25-inch SECUROCK Gypsum-Fiber Roof TPO-c BA or Aqua C-15. structural concrete Min.2-inch Poly ISO 1,H-Shield,H-Shield CG OB500 Board OB500 Mule-Hide TPO c Base 120 BA 247.5 MULE-HIDETPO-C FLEECE BACKAPPLICATIONS ' Exterior Research and Design,LLC.d/b/a Trinity ERD Evaluation Report M15060.06.09-R5 for FL12772-RS Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 5:09/11/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide TPO-c Single Ply Roof Systems;(608)365-3111 Appendix 1,Page 17 of 27 C)o \,J---f RINI ERD TABLE 3A:,STRUCTURA1LCONCRETE.DECKS-NEW CONSTRUCTION IiIi;REROOF.(TEae OFF) SYS tEIVI - ON,BONDED ROOF;COVER A,1 BONDED INSULATI REFER TO NOTE'A9 FOR,APOR BA RRIER OPbION3 .' t System Roof Deck Base Insulation Layer Top Insulation Layer Roof Cover(Note 16) MDP No. (Note 1) Type Attach Type Attach Membrane Application (pso C-16. Min.2,500 psi Min.1.5-inch Poly ISO 1,H-Shield,Polyiso HP-H, HELIX Min.0.5-inch Poly ISO 1-HD,H-Shield HD, HELIX Mule-Hide TPO-c HELIX(FULL) -165.0 structural concrete Poly ISO 2,ACFoam II,H-Shield CG,SecurShield SecurShield HD Plus Fleece Back Min.0.25-inch Dens Deck Prime,DEXcell FA Glass C-17. Min. ural psi Min.1O inch Poly ISO 1,H-Shield,Polyiso MeldHP-HHELIX Mat Roof Board,SECUROCK Gypsum-Fiber Roof HELIX Mule-Hide TPO-c HELIX(FULL) -195.0 structural concrete Poly I50 2,ACFoam II,H-Shield CG,SecurShield Fleece Back Board or min.7/16-inch DEXcell Cement Roof Board C-18. Min.2,500 psi Min.1.5-inch Poly ISO 1,H-Shield,Polyiso HP-H, HELIX (Optional)Additional layers of base insulation HELIX Mule-Hide TPO-C HELIX(FULL) -322.5 structural concrete Poly ISO 2,ACFoam II,H-Shield CG,SecurShield Fleece Back 'MULE=HIDESA?TPOAOPUI 'TIONS. C-19. Min.2,500 psi (Optional)One or more layers,min.1-inch HELIX,4- Min.2-inch Insulfoam SP HELIX,4- Mule-Hide SA- structural concrete Insulfoam I,II,IX,VIII,XIV or XV inch o.c. inch o.c. TPO Self-adhered 315.0 '. ,TABLE 36 STRUCTURAL.CONCRETE DECKS NEW CONSTRUCTION,REROOF•(Tear=Off)or.RECOVER SYSTEM.TYPE C 2,MECHANICALLY ATTACHED INSULATION,PLATE BONDED,ROOF COVER System Deck Attachment MDP Insulation Layer Roof Cover No. (Note 1) Fasteners Density (psf) 1 per 5.33 ft'Min.2,500 Min.1-inch thick,one or more Mule-Hide DHP Fastener and RhinoBond Plate (6 parts per 4 x 8 ft board) Mule-Hide TPO-c bonded to RhinoBond Plate-TPO or C-20. psi structural layers,an combination. -TPO or RhinoBond Treadsafe Plate-TPO per manufacturer's Treadsafe Plate i ns. with RHINOBOND tool 45.0 concrete y y Per FM Loss Prevention Data per manufacturer's instructions. Sheet 1-29;Note A 1per 4ft2 Min.2,500 Min.1-inch thick,one or more Mule-Hide DHP Fastener and RhinoBond Plate (8 parts per 4 x 8 ft board) Mule-Hide TPO-c bonded to RhinoBond Plate-TPO or C-21. psi structural layers,an combination. -TPO or RhinoBond Treadsafe Plate-TPO per manufacturer's Treadsafe Plate i ns. with RHINOBOND tool 60.0 concrete y y Per FM Loss Prevention Data per manufacturer's instructions. Sheet 1-29;Note A 1 per 2 ft2 Min.2,500 Min.1.5-inch thick,one or more Mule-Hide DHP Fastener and RhinoBond Plate (16 parts per 4 x 8 ft board) Mule-Hide TPO-c bonded to RhinoBond Plate-TPO or C-22. psi structural layers,an combination. Note B. -TPO or RhinoBond Treadsafe Plate-TPO per manufacturer's Treadsafe Plate i ns. with RHINOBOND tool 97.5 concrete y y Per FM Lass Prevention Data per manufacturer's instructions. Sheet 1-29 Min.2,500 Min.1.5-inch thick,one or more Mule-Hide DHP Fastener and RhinoBond Plate Mule-Hide TPO-c(minimum 60-mil)bonded to RhinoBond C-23. psi structural layers,any combination,prelim TPO or RhinoBond Treadsafe Plate-TPO 12-inch o.c.in rows 120-inch o.c. Plate-TPO or RhinoBond Treadsafe Plate-TPO with -30.0 concrete attach(Note 14) RHINOBOND tool per manufacturer's instructions. Min.2,500 Min.1.5-inch thick,one or more Mule-Hide DHP Fastener and RhinoBond Plate Mule-Hide TPO-c bonded to RhinoBond Plate-TPO or C-24, psi structural layers,any combination,prelim -TPO or RhinoBond Treadsafe Plate-TPO 6-inch o.c.in rows 120-inch o.c. RhinoBond Treadsafe Plate-TPO with RHINOBOND tool -37.5 concrete attach(Note 14) per manufacturer's instructions. Exterior Research and Design,I.I.C.d/b/a Trinity( ERD Evaluation Report M15060.06.09-R5 for FL12772-RS Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 5:09/11/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide TPO-c Single Ply Roof Systems;(608)365-3111 Appendix 1,Page 18 of 27 ERD - TRINI - _ TABLE 36 STRUCTURAL CONCRETE°DECKS.-.NEW CONSTRUCTION,REROOF(Tear-Off)or;RECOVER -SYS TEM,TYpE C 2. .MECHANICALLXATTACHED INSULATION,PLATE BONDED.ROOF COVER System DeckAttachment MDP Insulation Layer Roof Cover No. (Note 1) Fasteners Density (psf) Min.2,500 Min.1.5-inch thick,one or more Mule-Hide DHP Fastener and RhinoBond Plate Mule-Hide TPO-c bonded to RhinoBond Plate-TPO or C-25. psi structural layers,any combination,prelim -TPO or RhinoBond Treadsafe Plate-TPO 12-inch o.c.in rows 60-inch o.c. RhinoBond Treadsafe Plate-TPO with RHINOBOND tool -37.5 concrete attach(Note 14) per manufacturer's instructions. Min.2,500 Min.1.5-inch thick,one or more Mule-Hide DHP Fastener and RhinoBond Plate Mule-Hide TPO-c(minimum 60-mil)bonded to RhinoBond C-26. psi structural layers,any combination,prelim -TPO or RhinoBond Treadsafe Plate-TPO 12-inch o.c.in rows 60-inch o.c. Plate-TPO or RhinoBond Treadsafe Plate-TPO with -45.0 concrete attach(Note 14) RHINOBOND tool per manufacturer's instructions. Min.2,500 Min.1.5-inch thick,one or more Mule-Hide DHP Fastener and RhinoBond Plate Mule-Hide TPO-c(minimum 60-mil)bonded to RhinoBond C-27. psi structural layers,any combination,prelim -TPO or RhinoBond Treadsafe Plate-TPO 6-inch o.c.in rows 120-inch o.c. Plate-TPO or RhinoBond Treadsafe Plate-TPO with -52.5 concrete attach(Note 14) RHINOBOND tool per manufacturer's instructions. Min.2,500 Min.1.5-inch thick,one or more Mule-Hide DHP Fastener and RhinoBond Plate Mule-Hide TPO-c bonded to RhinoBond Plate-TPO or C-28. psi structural layers,any combination,prelim TPO or RhinoBond Treadsafe Plate-TPO 6-inch o.c.in rows 60-inch o.c. RhinoBond Treadsafe Plate-TPO with RHINOBOND tool 67.5 concrete attach(Note 14) per manufacturer's instructions. Notes: A. The plate/fastener combination offset 12 inch from adjacent rows. B. For these assemblies each row of insulation is staggered by 1 foot. TABLE 3C ,STRUCTURAL CONCRETE DE NEW-CONSTRUCTION oR:REROOF(TeAR-OFF) _ SYST TED,BONDED ROOF COVER EIVI TYPE F NON=INSULA System Deck Primer Roof Cover No. Type Attach MDP(psf) C-29. Structural concrete None Mule-HideSA-TPO Self-adhered -425.0 Exterior Research and Design,LLC.d/b/a Trinity I ERD Evaluation Report M15060.06.09-R5 for F1.32772-115 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 5:09/11/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide TPO-c Single Ply Roof Systems;(608)365-3111 Appendix 1,Page 19 of 27 -- - -T INI 1 ER® TABLE 4A:,LIGHTWEIGHT CONCRETE'DECKS=.NEIN CONSTRUCTION or-REROOF(Tear=Off) SYSTEM`TYPE A=1A BONDEDINSULATION;BONDED ROOF COVER System Base Insulation Layer Coverboard MDP Deck(Note 1) Lightweight Concrete(Note 15) Roof Cover.(Note 16) No. Type Attach Type Attach (psf) Structural Min.200 psi,Min.2-inch thick, Min.1-inch Poly ISO 1 or CR-20 (Optional)Additional layers base LWC-1 concrete Elastizell Range II LWIC H-Shield insulation CR-20 Mule-HideTPO-c/TPO-c BA 180.0 LWC-2 Structural Min.200 psi,Min.2-inch thick, Min.1-inch Poly ISO 1 or CR-20 (Optional)Additional layers base CR-20 Mule-Hide TPO-c/TPO-c BA -222.5 concrete Celcore MF Cellular Concrete H-Shield insulation LWC-3 Structural Min.200 psi,Min.2-inch thick, Min.1-inch Poly ISO 1 or CR-20 (Optional)Additional layers base CR-20 Mule-Hide TPO-c/TPO-c BA -240.0 concrete Mearlcrete H-Shield insulation Structural Min.250 psi,Min.2-inch thick, Min.1-inch Poly ISO 1 or OB500 (Optional)Additional layers base LWC-4 concrete Elastizell Range II LWIC H-Shield insulation OB500 Mule-Hide TPO-c/TPO-c BA 225.0 TABLE 4B 1: LIGHTWEIGHT.,;:CONC,RETE OVER`STEEL;DECK=NEW CONSTRUCTION OR:RE ROOF"{TEAR OFF) "' SYSTEMTYPE F:'NON INSULATED,BONDED:ROOF COVER Lightweight Concrete(Note 15) Roof Cover(Note 16) System Deck(Note 1) Surface Supplemental Attachment MDP No. Type Type Attach (psf) Treatment Fasteners Density Min.22 ga.,Type B,Grade 33 steel Min.36 pcf wet cast density,min.200 psi,min.2- LWC-5 at max.6 ft spans attached 6-inch inch thick Celcore MF Cellular Concrete(cast with None None N/A Mule-Hide TPO-c BA or Aqua TPO-c Base 120 BA -60.0 O.C. or without min.1"EPS holey board). Note A. Min.22 ga.,Type B,Grade 33 steel Min.38 pcf wet cast density,min.200 psi,min. 1.625-inch thick Celcore MF Cellular Concrete Mule-Hide LWC-6 at max.4 ft spans attached 6-inch followed by min.1-inch EPS holey board with min. Celcore PVA None N/A TPO-c TPO c BA 67.5 O.C. 2.0-inch thick topcoat. Note A. Min.36 pcf wet cast density,min.200 psi,min.2- Min.22 ga.,Type B,Grade 33 steel Mule-Hide HDP Fastener Z Mule-Hide TPO-c BA or Aqua -67.5 LWC-7 at max.6 ft spans 6-inch o.c. inch thick Celcore MF Cellular Concrete(cast with None with 3"Insulation Plate 1 per 9 ft TPO-c Base 120 BA Note B or without min.1"EPS holey board). Note A. Min.36 pcf wet cast density,min.200 psi,min.2- Min.22 ga.,Type B,Grade 33 steel Mule-Hide HDP Fastener z Mule-Hide TPO-c BA or Aqua -120.0 LWC-8 at max.6 ft spans 6-inch"o.c. inch thick Celcore MF Cellular Concrete(cast with None with 3"Insulation Plate 1 per 1 ft TPO-c Base 120 BA Note B -- - or without min.1"EPS holey board). Note A. Note A.) If the type of LWC to be used on the project is unknown,as in a re-roof(tear-off)condition,compressive strength and fastener withdrawal resistance testing shall be conducted. Compressive strength testing shall be in accordance with ASTM C495(for new pour)or ASTM C109(for existing)and shall yield a minimum 200 psi result. Field withdrawal resistance testing in accordance with TAS 105 or ANSI/SPRI FX-1 and shall yield an average withdrawal performance not less than 55 Ibf with a Trufast FM-90 Base Sheet Fastener. If question exists as to the adhesion to the LWC surface,field testing in accordance with ASTM E907 or FM Loss Prevention Data Sheet 1-29 is recommended.All testing shall be performed by an accredited testing agency acceptable to the Authority Having Jurisdiction. Note B.)Linear interpolation between supplemental attachment at 1 per 9 ftp for-67.5 psf and 1 per 1 ftz for-120.0 psf is permissible. Such interpolation shall be performed by a qualified design professional to the satisfaction of the Authority Having Jurisdiction. Exterior Research and Design,LLC.d/b/a Trinity( ERD Evaluation Report M15060.06.09-R5 for FL12772-RS Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 5:09/11/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide TPO-c Single Ply Roof Systems;(608)365-3111 Appendix 1,Page 20 of 27 F)o _ = I�11` ERS - TAkE`46 2`.LIGHTWEIGHT CONCRETEOVER STRUCTURAL CONCRETE=.NEW CONSTRUCTION TED, ROOF COVER ,SYSTEM TYPE F:;NOfJ INSULA BONDED System Deck(Note 1) Lightweight Concrete(Note 15) Roof Cover(Note 16) MDP No. Membrane Application (Pso LWC-9 Min.2,500 psi structural Min.250 psi,Min.2"thick,Elastizell Range II LWIC Mule-Hide TPO-c Aqua Base 120 BA -67.5 concrete Min.2,500 psi structural LWC-10 concrete Min.250 psi,Min.2"thick,Elastizell Range II LWIC(EPS board optional) Mule-Hide TPO-c TPO-c BA 240.0 LWC-11 Min.2,500 psi structural Min.300 psi,Min.2"thick,Elastizell Range II LWIC(no EPS board) Mule-Hide TPO-c TPO-c BA -495.0 concrete LWC-12 Min.2,500 psi structural Min.300 psi,Min.2"thick,Celcore Cellular Concrete Mule-Hide TPO-c Aqua Base 120 BA -82.5 concrete LWC-13 Min.2,500 psi structural Min.300 psi,Min.2"thick,Celcore Cellular Concrete Mule-Hide TPO-c TPO-c BA -135.0 concrete Min.2,500 psi structural Min.36 pcf wet cast density,min.200 psi,min.2-inch thick Celcore MF Cellular Concrete(cast with LWC-14 concrete or without min.1"EPS holey board). Note A. Mule-Hide TPO-c Aqua Base 120 BA 217.5 Min.2,500 psi structural Min.36 pcf wet cast density,min.200 psi,min.2-inch thick Celcore MF Cellular Concrete(cast with LWC-15 concrete or without min.1"EPS holey board). Note A. Mule-Hide TPO-c TPO-c BA -480.0 Note A.) If the type of LWC to be used on the project is unknown,as in a re-roof(tear-off)condition,compressive strength and fastener withdrawal resistance testing shall be conducted. Compressive strength testing shall be in accordance with ASTM C495(for new pour)or ASTM C109(for existing)and shall yield a minimum 200 psi result. Field withdrawal resistance testing in accordance with TAS 105 or ANSI/SPRI FX-1 and shall yield an average withdrawal performance not less than 55 Of with a Trufast FM-90 Base Sheet Fastener. If question exists as to the adhesion to the LWC surface,field testing in accordance with ASTM E907 or FM Loss Prevention Data Sheet 1-29 is recommended.All testing shall be performed by an accredited testing agency acceptable to the Authority Having Jurisdiction. Exterior Research and Trinity Design,LLC.d/b/a g ( ERD Evaluation Report M15060.06.09-RS for FL12772-R p 5 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 5:09/11/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide TPO-c Single Ply Roof Systems;(608)365-3111 Appendix 1,Page 21 of 27 F)o - TRI I +ERD TA BLE'SA GYPSUM DECKS REROOF'(Tear Off).`. �. . SYSTEMTYPE A=1 BONDED.INSULATION;BONDED ROOF;•COVER:. System Base Insulation Layer Top Insulation Layer Roof Cover(Note 16) MDP No. Deck(Notes 1&12) Type Attach Type Attach Type Application (Psf) G-1. Existing sound gypsum or Min.1.5-inch ACFoam II,H-Shield,ENRGY 3 or Poly ISO 1, CR-20 (Optional)Additional layers CR-20 Mule-Hide TPO-c Aqua Base 120 BA -127.5 gypsum plank Poly ISO 2 of base insulation G-2. Existing sound gypsum or (Optional)Min.1.5-inch ACFoam II,H-Shield,ENRGY 3 or CR-20 Min.Y.-inch Dens Deck or CR-20 Mule-Hide TPO-c Aqua Base 120 BA -127.5 gypsum plank Poly ISO 1,Poly 150 2 Dens Deck Prime G-3. Existing sound gypsum or Min.1.5-inch ACFoam II,H-Shield,ENRGY 3 or Poly ISO 1, CR-20 (Optional)Additional layers CR-20 Mule-Hide TPO-c TPO-c BA -232.5 gypsum plank Poly ISO 2 of base insulation G-4. Existing sound gypsum or (Optional)Min.1.5-inch ACFoam II,H-Shield,ENRGY 3 or CR-20 Min.Y4-inch Dens Deck or CR-20 Mule-Hide TPO-c TPO-c BA -232.5 gypsum plank Poly ISO 1,Poly ISO 2 Dens Deck Prime Exterior Research and Design,I.I.C.d/b/a Trinity I ERD Evaluation Report M15060.06.09-R5 for FL12772-RS Certificate of Authorization#9503 6'"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 5:09/11/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide TPO-c Single Ply Roof Systems;(608)365-3111 Appendix 1,Page 22 of 27 F)o TRlI ITY I-ERD - - TABLE 6A:'RECOVER APPLICATIONS 'SYSTE M�TYPE,:*!:.BON,DED,INSULATIO„N,BONDED ROOE:,COVER System Substrate Base Insulation Layer Top Insulation Layer Roof Cover(Note 16) MDP No. (Notes 1&12) Type Attach Type Attach Type Application (psfl Existing asphaltic BUR or Min.1.5-inch ACFoam II,H-Shield,ENRGY 3 or Poly CR-20 (Optional)Additional layers of base CR-20 Mule-Hide R-1 mineral surface cap sheet ISO 1,Poly ISO 2 insulation TPO-c Aqua Base 120 BA 127.5 Min.%-inch Dens Deck or Dens Deck R 2 Existing asphaltic BUR (Optional)Min. inch ACFoam II,H-Shield, CR-20 Prime or SECUROCK Gypsum-Fiber CR-20 Mule-Hide Aqua Base 120 BA -127.5 Roof Board mineral surface cap sheet ISO ENRGY 3 or Poly ISO 1,Poly ISO 2 TPO-c Existing asphaltic BUR or Min.1.5-inch ACFoam II,H-Shield,ENRGY 3 or Poly CR-20 (Optional)Additional layers of base CR-20 Mule-Hide R 3 mineral surface cap sheet ISO 1,Poly ISO 2 insulation TPO c TPO-c BA 232.5 Existingasphaltic BUR or Min.%-inch Dens Deck or Dens Deck R-4 p (Optional)Min. IS inch ACFoam II,H-Shield, CR-20 Prime or SECUROCK Gypsum-Fiber CR-20 TPO-c Mule-Hide TPO-c BA -232.5 mineral surface cap sheet ENRGY 3 or Poly ISO 1,Poly ISO 2 Roof Board TPO-c Existing asphaltic BUR or Min.1.5-inch ACFoam II,H-Shield,ENRGY 3 or Poly OB500 (Optional)Additional layers of base Mule-Hide TPO-c BA or Aqua Base R-5 mineral surface cap sheet ISO 1,Poly ISO 2 insulation OB500 TPO-c 120 BA 120.0 Y.-inch Dens Deck, Existing asphaltic BUR or (Optional)Min.1.5-inch ACFoam II,H-Shield, Min. Dens Deck Mule-Hide TPO-c BA or Aqua Base R-6 mineral surface cap sheet ENRGY 3 or Poly ISO 1,Poly ISO 2 OB500 Prime or SECUROCK Gypsum-Fiber OB500 TPO-c 120 BA -120.0 Roof Board Exterior Research and Design,I.I.C.d/b/a Trinity) ERD Evaluation Report M15060.06.09-R5 for FL12772-RS Certificate of Authorization#9503 6T”EDITION(2017)FBC NON-HVHZ EVALUATION Revision 5:09/11/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide TPO-c Single Ply Roof Systems;(608)365-3111 Appendix 1,Page 23 of 27 )o --- -=TRINITY( ESD -- T - ABLE 66 STEEL RECOVER -< ;.SYSTEM;TYPE G2 PLATE-BONDED ROOF,COVER;,,. All areas whereahe ezistin mefdL anels•do nofi la lush"om'the underl'in urin shall h'dve,a0.25=inch didmeter ilof hole re7dr�lled into the` ane! noc•#o:dnvm the Purlin;Fasten"er.into the `urhn ..:` 8-..--.,P a. . .. Yf �._..Y 9P. _ . p p P p. 9._. Bpd System Substrate Insulation Layer Attachment Roof Cover/Adhesive MDP(psf) No. (Note 1) Fasteners(Note 11) Spacing Existing standing seam or lap seam metal One or more layers,any Mule-Hide Purlin Fastener and Mule-Hide TPO-c(minimum 60-mil)bonded to R-7 roof covers having min.16 gauge(0.0598 combination, RhinoBond Plate-TPO are fastened 12-inch o.c.along purlins RhinoBond Plate-TPO with RHINOBOND tool -30.0 inch),50 ksi or min.12 gauge(0.105 in.),36 preliminarily fastened through to purlinsper manufacturer's instructions. ksi steel purlins spaced max.120-inch o.c. Existing standing seam or lap seam metal One or more layers,any Mule-Hide Purlin Fastener and Mule-Hide TPO-c bonded to RhinoBond Plate- roof covers having min.16 gauge(0.0598 R-8 combination, RHINOBOND Insulation Plate(TPO) 6-inch o.c.along purlins TPO with RHINOBOND tool per manufacturer's -37.5 inch),50 ksi or min.12 gauge(0.105 in.),36 preliminarily fastened are fastened through to purlins instructions. ksi steel purlins spaced max.120-inch o.c. Existing standing seam or lap seam metal One or more layers,any Mule-Hide Purlin Fastener and Mule-Hide TPO-c bonded to RhinoBond Plate- roof covers having min.16 gauge(0.0598 R-9 combination, RHINOBOND Insulation Plate(TPO) 12-inch o.c.along purlins TPO with RHINOBOND tool per manufacturers -37.5 inch),50 ksi or min.12 gauge(0.105 in.),36 preliminarily fastened are fastened through to purlins instructions. ksi steel purlins spaced max.60-inch o.c. Existing standing seam or lap seam metal One or more layers,any Mule-Hide Purlin Fastener and Mule-Hide TPO-c(minimum 60-mil)bonded to roof covers having min.16 gauge(0.0598 R-10 combination, RHINOBOND Insulation Plate(TPO) 12-inch o.c.along purlins RhinoBond Plate-TPO with RHINOBOND tool -45.0 inch),50 ksi or min.12 gauge(0.105 in.),36 preliminarily fastened are fastened through purlins ksi steel purlins spaced max.60-inch o.c. p y g to p per manufacturers instructions. Existing standing seam or lap seam metal One or more layers,any Mule-Hide Purlin Fastener and Mule-Hide TPO-c(minimum 60-mil)bonded to roof covers having min.16 gauge(0.0598 R-11 combination, RHINOBOND Insulation Plate(TPO) 6-inch o.c.along purlins RhinoBond Plate-TPO with RHINOBOND tool -52.5 inch),50 ksi or min.12 gauge(0.105 in.),36 preliminarily fastened are fastened through purlins ksi steel purlins spaced max.120-inch o.c. p y g to p per manufacturers instructions. Existing standing seam or lap seam metal One or more layers,any Mule-Hide Purlin Fastener and Mule-Hide TPO-c bonded to RhinoBond Plate- roof covers having min.16 gauge(0.0598 R-12 combination, RHINOBOND Insulation Plate(TPO) 6-inch o.c.along purlins TPO with RHINOBOND tool per manufacturers -67.5 inch),50 ksi or min.12 gauge(0.105 in.),36 preliminarily fastened are fastened through to purlins instructions. ksi steel purlins spaced max.60-inch o.c. Exterior Research and Design,LLC.d/b/a Trinity I ERD Evaluation Report M15060.06.09-R5 for FL12772-R5 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 5:09/11/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide TPO-c Single Ply Roof Systems;(608)365-3111 Appendix 1,Page 24 of 27 F)o -""4TRINITY ERD ! BL STEEL T VER SYSTEM -1:,INSULAT�p,,MECHANICALLYATTAPHED.,�p(, TYPED Z' t grne 76sh�bh 0�6 un er yin _p rivin A '�-4 6�E t&1 p6neWd6ho laij g,pur ir�,M hav&a,0; 4rich dldniet& ilothb�ejorO-#�YlOd.Jn "the'pane�'Priorjq4 ;the iri.'Fbft4�ifer into,the: ur inj t �5 System Deck(Note 1) insulation Roof Cover MDP No. Type Attach Membrane Fasteners(Note 11) Attachment (pso Existing standing seam or lap seam metal roof covers One or more layers, Prelim. Mule-Hide TPO-c Mule-Hide Purlin Fastener 12-inch o.c.within 5.5-inch wide laps spaced R-13 having min.16 ga.(0.0598-inch)to max.3/16-inch any combination attach or TPO-c EXTRA and 2.4 Seam Plate max.138.5-inch o.c.to engage steel purlin. -30.0 thick steel purlins spaced max.138.5-inch o.c. Laps sealed with 1.5-inch heat weld. Existing standing seam or lap seam metal roof covers One or more layers, Prelim. Mule-Hide TPO-c Mule-Hide Purlin Fastener 12-inch o.c.within n 5.5-inch wide laps spaced R-14 having min.16 ga.(0.0598-inch)to max.3/16-inch any combination attach or TPO-c EXTRA and 2.4 Seam Plate max.115-inch o.c.to engage steel purlin. Laps -45.0 thick steel purlins spaced max.115-inch o.c. sealed with 1.5-inch heat weld. Existing standing seam or lap seam metal roof covers One or more layers, Prelim. Mule-Hide TPO-c Mule-Hide Purlin Fastener 12-inch o.c.within 5.5-inch wide laps spaced R-15 having min.16 ga.(0.0598-inch)to max.3/16-inch any combination attach or TPO-c EXTRA and 2.4 Seam Plate max.54.5-inch o.c.to engage steel purlin. Laps -60.0 thick steel purlins spaced max.54.5-inch o.c. sealed with 1.5-inch heat weld. Existing standing seam or lap seam metal roof covers One or more layers, Prelim. Mule-Hide TPO-c Mule-Hide Purlin Fastener 6-inch o.c.within 5.5-inch wide laps spaced R-16 having min.16 ga.(0.0598-inch)to max.3/16-inch any combination attach or TPO-c EXTRA and 2.4 Seam Plate max.138.5-inch o.c.to engage steel purlin. -60.0 thick steel purlins spaced max.138.5-inch o.c. Laps sealed with 1.5-inch heat weld. Existing standing seam or lap seam metal roof covers One or more layers, Prelim. Mule-Hide TPO-c Mule-Hide Purlin Fastener 6-inch o.c.within 5.5-inch wide laps spaced R-17 having min.16 ga.(0.0598-inch)to max.3/16-inch any combination attach or TPO-c EXTRA and 2.4 Seam Plate max.90.5-inch o.c.to engage steel purlin. Laps -67.5 thick steel purlins spaced max.90.5-inch o.c. sealed with 1.5-inch heat weld. Existing standing seam or lap seam metal roof covers One or more layers, Prelim. Mule-Hide TPO-c Mule-Hide Purlin Fastener 9-inch o.c.within 5.5-inch wide laps spaced R-18 having min.16 ga.(0.0598-inch)to max.3/16-inch any combination attach or TPO-c EXTRA and 2.4 Seam Plate max.114.5-inch o.c.to engage steel purlin. -75.0 thick steel purlins spaced max.114.5-inch o.c. Laps sealed with 1.5-inch heat weld. Existing standing seam or lap seam metal roof covers One or more layers, Prelim. Mule-Hide TPO-c Mule-Hide Purlin Fastener 6-inch o.c.within 5.5-inch wide laps spaced R-19 having min.16 ga.(0.0598-inch)to max.3/16-inch any combination attach or TPO-c EXTRA and 2.4 Seam Plate max.42.5-inch o.c.to engage steel purlin. Laps -82.5 thick steel purlins spaced max.42.5-inch o.c. I sealed with 1.5-inch heat weld. Existing standing seam or lap seam metal roof covers One or more layers, Prelim. Mule-Hide TPO-c Mule-Hide Purlin Fastener 6-inch o.c.within 5.5-inch wide laps spaced R-20 having min.16 ga.(0.0598-inch)to max.3/16-inch any combination attach or TPO-c EXTRA and 2.4 Seam Plate max.114.5-inch o.c.to engage steel purlin. -90.0 thick steel purlins spaced max.114.5-inch o.c. Laps sealed with 1.5-inch heat weld. Exterior Research and Design,LLC.d/b/a Trinity I ERD Evaluation Report M15060.06.09-R5 for FL12772-RS Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 5:09/11/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide TPO-c Single Ply Roof Systems;(608)365-3111 Appendix 1,Page 25 of 27 F)o - --_- -TRIM I-ERD- tA BLE 6D :RECO.VER APPLICATIONS ,. SYSTEM TYPE,E-1 NON.INSULATED;MECHANICALLYATiACHED ROOF DOVER.;'' U... . System Deck Roof Cover No. (Note 1) Membrane Fasteners(Note 31) Fastener Spacing Lap Width Lap Spacing Seam Weld MDP(psf) (inch) (inch) (inch) (inch) R-21 Existingsteel deck Mule-Hide TPO-c Mule-Hide EHD Fastener and Mule-Hide 2.4"Seam Plates installed Fleece Back,60-mil through to engage existing deck (Field W/D>695lbf) 12 5 139 1.5 30.0 R-22 Existing steel deck, Mule-Hide TPO-c Mule-Hide EHD Fastener and Mule-Hide 2.4"Seam Plates installed min.Grade 80 Fleece Back through to engage existing deck(Field W/D>6951bfJ 12 5.5 139 1.5 30.0 Mule-Hide TPO-c Mule-Hide EHD Plus Fasteners and Mule-Hide 2.4" PLUS Seam Plate R-23 Existing steel deck Fleece Back,60-mil installed through to engage existing deck (Field W/D>434lbf) 6 5 139 1.5 37.5 R-24 Existing steel deck, Mule-Hide TPO-c Mule-Hide EHD Fastener and Mule-Hide 2.4"Seam Plates installed min.Grade 80 Fleece Back through to engage existing deck(Field WIDL434lbfJ 6 5.5 139 1.5 37.5 Mule-Hide TPO-c Mule-Hide EHD Plus Fasteners and Mule-Hide 2.4" PLUS Seam Plate R-25 Existing steel deck Fleece Back,60-mil installed through to engage existing deck (Field W/D>719lbf) 12 5 115 1.5 -37.5 Existing steel deck, Mule-Hide TPO-c Mule-Hide EHD Plus Fasteners and Mule-Hide 2.4" PLUS Seam Plate R-26 min.Grade 80 Fleece Back installed through to engage existing deck(Field W/D>719lbf) 12 5.5 115 1.5 37.5 Existing steel deck, Mule-Hide TPO-c Mule-Hide EHD Fastener and Mule-Hide 2.4"Seam Plates installed R 27 min.Grade 80 Fleece Back through to engage existing deck(Field W/D2:455 lbf) 6 5.5 91 1.5 60.0 R-28 Existing steel deck, Mule-Hide TPO-c Mule-Hide EHD Plus Fasteners and Mule-Hide 2.4" PLUS Seam Plate 12 5 91 1.5 -60.0 min.Grade 80 Fleece Back,60-mil installed through to engage existing deck(Field W/D>910lbf) R-29 Existing structural Mule-Hide TPO-c Mule-Hide HDP Fastener and Mule-Hide 2.4"Seam Plates installed concrete Fleece Back through to engage existing deck(Field W/D>695lbf) 12 5.5 139 1.5 30.0 R-30 Existing structural Mule-Hide TPO-c Mule-Hide HDP Fastener and Mule-Hide 2.4"Seam Plates installed concrete Fleece Back through to engage existing deck Plates(Field W/D>434lbf) 6 5.5 139 1.5 37.5 R-31 Existing structural Mule-Hide TPO-c Mule-Hide HDP Fastener and Mule-Hide 2.4"Seam Plates installed concrete Fleece Back through to engage existing deck(Field W/D>7191bfJ 12 5.5 115 1.5 37.5 R-32 Existing structural Mule-Hide TPO-c Mule-Hide HDP Fastener and Mule-Hide 2.4"Seam Plates installed concrete Fleece Back through to engage existing deck(Field W/D>455lbf) 6 5.5 91 1,5 60.0 R-33 Existing structural Mule-Hide TPO-c Mule-Hide HDP Fastener and Mule-Hide 2.4"Seam Plates installed concrete Fleece Back,60-mil through to engage existing deck (Field W/D>9101bf) 12 5 91 1.5 -60.0 Exterior Research and Design,LLC.d/b/a Trinity I ERD Evaluation Report M15060.06.09-R5 for FL12772-R5 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 5:09/11/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide TPO-c Single Ply Roof Systems;(608)365-3111 Appendix 1,Page 26 of 27 TRINITY ER® ABLE 6E:,RECOVER APPLICATIONS -SYSTEM TYPE F 2 NEW TWEIGHTCONCRETk,OVEFtEXITISliNis BONDED ROOF.0VE R:�;',�_ 0 System Substrate(Notes 1&12) Roof Cover(Note 16) Lig MDP No. Deck Existing Roof Lightweight Concrete(Note 15) Type Attach (Psf) R-34 Structural Existing asphalt BUR or smooth-or granule-surface Min.250 psi,Min.2-inch thick,Elastizell Range 11 LWIC Mule-Hide TPO-c Aqua Base 120 BA -67.5 concrete SBS modified bitumen (EPS board optional) R-35 Structural Existing asphalt BUR or granule-surface SBS modified Min.250 psi,Min.2-inch thick,Elastizell Range 11 LWIC Mule-Hide TPO-c TPO-c BA -302.5 concrete bitumen (EPS board optional) R-36 Structural Existing asphalt BUR or smooth-surface SBS modified Min.250 psi,Min.2-inch thick,Elastizell Range 11 LWIC Mule-Hide TPO-c TPO-c BA -342.0 concrete bitumen (EPS board optional) Exterior Research and Design,U.C.d/b/a Trinity I ERD Evaluation Report M15060.06.09-R5 for FL12772-RS Certificate of Authorization#9503 6'"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 5:09/11/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide TPO-c Single Ply Roof Systems;(608)365-3111 Appendix 1,Page 27 of 27