Product Evaluation Report
GULF COAST SUPPLY& MANUFACTURING, LLC. RECEIVED
JUN 13 1019
26 Ga. 5V Crimp Roof Panel over 15132"Plywood Permitting Department
5t. Lucie County
Florida Product Approval #11651.13 f
r>"
Florida Building Code 2017
Per Rule 61 G20-3 EVIEWED
Method: 1 —D CODE COMPLIANCE
Category: Roofing ST. LUCIE CSU
TY
Subcategory: Metal Roofing BOCC
Compliance Method: 61 G20-3.005(1)(d)
NON HVHZ
Product Manufacturer:
Gulf Coast Supply & Manufacturing, LLC.
14429 SW 2nd Place, Suite G30
11
Newberry, FL 32669 `��t�%F-L j f ,
N1E� S, k �.
OCEMSF•.'L
Engineer Evaluator: ,♦•-' No, 75518 ••:
Dan Kuhn, P.E. #75519
�1
Florida Evaluation ANE ID: 10743 .-o=
STATE OF '
A
�.
Validator: R! ?'•G���%
Locke Bowden, P.E. #49704
9450 Alysbury Place
Montgomery, AL 36117
Contents:
Evaluation Report Pages 1 - 5
FL#11651.13 R3•OCTOBER 5,2017
P s ® , ® s . t
�",Wa
FL [DA .'ROD.U. IUA-L G U If Cza,
OV5
SUPPLY $e MANUFACTURING
5VCRIMIP
}
FLORIDA • • , APPROVAL NO.
TM
Compliance Statement: The product as described in this report has demonstrated compliance with the
Florida Building Code 2017, Sections 1504.3.2.
Product Description: 5V Crimp Roof Panel, 26 Ga. Steel, 24" Coverage, through fastened
roof panel with fasteners in the panel flat over minimum 15/32" plywood decking.
Non Structural application.
Panel Material/Standards: Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to
Florida Building Code 2017 Section 1507.4.3.
Paint Finish Optional
Yield Strength: 80.0 ksi
Corrosion Resistance: Panel Material shall comply with Florida Building
Code 2017, Section 1507.4.3.
Panel Dimension(s): Thickness: 0.018" Minimum
Width: 24" Coverage
Rib Height: 3/a" Major Rib
Panel Fastener: #9-15x1.5" with sealing washing in the flat of the panel or approved equal,
1/4" minimum penetration through plywood.
Corrosion Resistance: Per Florida Building Code 2017, Section 1506.6, 1507.4.4
Substrate Description: Minimum 15/32" thick, APA Rated plywood over supports at maximum 24" O.C.
Design of plywood and plywood supports are outside the scope of this
evaluation. Must be designed in accordance w/Florida Building Code 2017.
Design Uplift Pressures: Table"A"
M Xitnum TotalUp(rf®esign Pressure 945sf � 1s3c10psfk•'
Fastener Pattern 12"-12" 9.5"-2"-9.5"
Fastene Pattern Spa, , cog" �- 6" �C+� ,1'6Q.C:
Design Pressure includes a Safety Factor=2.0.
I
FL#11651.13 R3•OCTOBER 5,2017
s ® ® ® s ® ® RTT
o
-Gr'APRR, Gulf
SUPPLY &e MANUFACTURING
5VCwKffi8' 1MP
26 GA. 5VCRIMP ROOF PANEL OVER 15/32" PLYWOOD
FLORIDA OD APPROVAL •
;r TM
Code Compliance: The product described herein has demonstrated compliance with the
Florida Building Code 2017, Sections 1504.3.2.
Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load
requirements of the Florida Building Code 2017, as relates to Rule 61 G20-3.
Performance Standards: The product described herein has demonstrated compliance with:
• UL 580-06-Test for Uplift Resistance of Roof Assemblies
• UL 1897-12- Uplift Test for Roof Covering Systems.
Reference Data: 1. UL 580-94/ 1897-98 Uplift Test
Force Engineering &Testing, Inc. (FBC Organization #TST-5328)
Report No. 117-0053T-05 & 117-0331T-08
2. Certificate of Independence
By Dan Kuhn, P.E. (FL#75519)@ Kuhn Engineering, LLC
(FBC Organization#ANE ID: 10743)
Test Standard Equivalence: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard.
2. The UL 1897-98 test standard is equivalent to the UL 1897-12 test
standard.
Quality Assurance Entity: The manufacturer has established compliance of roof panel products in
accordance with the Florida Building Code and Rule 61 G20-3.005(3)for
manufacturing under a quality assurance program audited by an approved quality
assurance entity.
Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2017, including
Section 1507.4.2 and in accordance with Manufacturers recommendations. For
slopes less than 3:12, lap sealant must be used in the panel side laps.
Installation: Install per Manufacturer's recommended details.
Underlayment: Shall comply with Florida Building Code 2017 section 1507.1.1.
Roof Panel Fire Classification: Fire classification is not part of this acceptance.
Shear Diaphragm: Shear Diaphragm values are outside the scope of this report.
FL#11651.13 R3•OCTOBER 5,2017
000
/Mv
D.U, Gulfc'Ta�f
SUPPLY ✓3< MANUFACTURING
5VCRIMP
t
26 GA. 5VCRIMP ROOF PANEL OVER 15/32" PLYWOOD
• , PRODUCT APPROVALO
Design Procedure: For roofs within the parameters listed on the load table,fastening pattern must
at a minimum meet those listed for the applicable wind zone. For all roofs outside
the parameters listed on the load table, design wind loads shall be determined
for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10
using allowable stress design.The maximum fastener spacing listed herein shall
not be exceeded.This evaluation report is not applicable in High Velocity
Hurricane Zone. Refer to current NOA or HVHZ evaluation report for use of this
product in High Velocity Hurricane Zone.
FL#11651.13 R3•OCTOBER 5,2017
PRODUCTEVALUATIQN. . • ® .
ENGINEERING,KUHN
7:7 -
i
Gulfc(Dayt
SUPPLY & MANUFACTURING
5VCRIMP
FLORIDA1 26 GA. 5VCRIMP ROOF PANEL OVER 15/32" PLYWOOD
PRODUCT APPROVAL NO.
TM
ENGINEER LOAD TABLE:26 Ga. 5VCrimp Roof Panel over 15/32"Plywood
Billdln s'.havinn aaoofIVlean,Hel ht `20 O,n'r-Roof 510 e2 >%12 X12 %12' °Gable�or HI' Roof;WlndSfr'�eetls120 hs4 'a{, ,
p ...7,r.' ,33'srk„9 Yt'_..�r,- ..�A, tF:$pf�'`S..it�t`� '�5, ''�r}`"'' .,' i°':t-°...�' `''✓ 'p '4' ". a' i'y°aY �`'i's�>r2�,znp _.
.khhai
�8Q;mph ��xposure:�C�sk�Categoryxll;Enclosed�8uildmg r�basedon�Ffonda Bulld►ng�Code24;17 � .�����s=��;' �,�{ s,���r �,� ,
120 130 140 150 160 170 180
WIIND FASTENER SUBSTRATE
SPEED (MIN.v4" (MIN.15/32 ) ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER
Penetration) SPACING SPACING SPACING SPACING SPACING SPACING SPACING
F .lS r y* l F _n 4 f;:.4 <a 1t:.,:'k !/� f .f7 ,; :.L r'rt i3 �yk;.,:h t��-."'vf .G ¢'i ,rl{£' ',.M , oi;y. 1,>7tlV.a„rdl �rn✓ :
ZONE'f #9-15x1 5 PI}IWOOd° "16�tTYPEz1 f;16",TYPE 1 15"TYPE,116plYPE41rt16"Trl(PE 1`x 16"�iTYPE116f 7` PE 1f
ZONE 2 #9-15x1.5" Plywood 16"TYPE 1 16"TYPE 1 16"TYPE 1 16"TYPE 1 16"TYPE 1 16"TYPE 1 16"TYPEy1
"30rkkr ; fjrh'- 'Y w+) .e,.,m`,�R5#0.�R�n`3 ,.2,)i•��3p�5 4ti '�R"PisAy>1:.
ZONE 3, #9-15X1 5" ``Plywootl� 76"TYPE1, X16"TYPE 1 "16"TYPE�1� 16"TYPE�1 �16TYPEu11�61YPE21$6TYPE,2
1.)PANEL DESCRIPTION:5V CRIMP, MIN.26 GA., GRADE 80,24"COVERAGE.
2.)PANEL FASTENER:#9-15X1.5" HWH WITH SEALING WASHER W/MIN. A" PENETRATION.
3.)MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE:-94.25 PSF@ 16" O.C. FASTENER SPACING TYPE 1 FASTENER PATTERN,-131.0
PSF @16" O.C. FASTENER SPACING TYPE 2 FASTENER PATTERN BASED ON TAS 125,UL 580/UL 1897 TESTING.
4.)PLYWOOD DECKING: MIN.15/32"THICK PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 2017.
5.)ROOF SLOPE:ON ROOF SLOPES LESS THAN 3:12, LAP SEALANT MUST BE USED IN PANEL SIDE LAPS.
6.)LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10(KD=0.85) MULTIPLIED BY 0.6 PER FLORIDA BUILDING
CODE 2017.
ZONE 2 HIP ROOF ZONE 3 `j Note:Dimension(a)is defined as 10%of the minimum width of the building or
40%of the mean height of the roof,whichever is smaller,however,(a)cannot be
--_ -_------- �' less than either 4%of the minimum width of the building or 3 feet.
RIDGE TYPE 1 FASTENER PATTERN
----------- `� (1) #9-15 x 1-1/2" HWH w/Sealing Washer
ZONE 1 1211 —1211
/------------------
-EAVE At Panel Lap
ZONE 2 CABLE ROOF
-J- ------------------
TYPE
------ ----- TYPE 2 FASTENER PATTERN
RIDGE ; (1) #9-15 x 1-1/2" HWH w/Sealing Washer
------ — ------------tea 2.1 9.5.1 9.5.1
-------- ------ I
ZONE 1 w`
I I
ZONE 3 EVE
FL#11651.13 R3•OCTOBER.5,2017