HomeMy WebLinkAboutProduct Approval-Underlayment 512012018 Miami-Dade County
go ("P
Miami-Dade County Building
Product Control Search Results
perf6ittling.Depart"""t
QUERY PARAMETERSSt.LUTcounty
File Classification: Unknown I Unselected
Applicant: lntendrap,!nc.
Category: None
Subcategory: None
Material: None
Impact Rate: None
Maximum Design Pressure(+): 0.00
Maximum Design Pressure(.): 0.00
NOA APPLICANT CATEGORY SURCATEG09Y MATERIAL DESCRIPMON IMPACT MDP+ MOP- CLASSLUBSC E"IRES
18-0814.09 i
0 Lnlenaraojnr (pS- Roofing Undedayments Polypropylene Titanium-UDL Unselected 0 0 High velocity August
.......... r.oductcontrallhoalI8081409.ndf Les I Ulf detail app.asp? 30,Titanium- I Unknown hurricane zone 82023
ago alias=102012) UDL 50,
RhinoRoof
f
U20,and
Titanium
UDL25
Synthetic
Undertayments;
Recs
For a detailed description on the File Status,click the NOA File Status Key-1/buff din c-result key gp_p&s_p)
Page Last Edited:Wed Jan 25,2017 10:40:27 AM
FOR
MIAW=*E OR DE COMPLIANCPE
ST. LUCIE COU
y
www.miamidade.gov/building/pc-result app.aSP?RdNOA;:&ClassificaUon--0%2CUnknownt%2FtUnselertedo/o2Cl&AdVancedSearch=Go&applicanUis... 1/1
t
i
E
i
MIAMI-RADE COUNTY
MIAMI-
PRODUCT CONTROL SECTION
11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)31525-99
NOTICE OF ACCEPTANCE (NOA) www.mlamidade.Qoe/economv
Interwrap,Inc.
32923 Mission Way
Mission,BC,Canada V2V-6E4
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submittedbas been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid-after the expiration date stated below_ The Miami Dade County Product Control
Section (In Miami Dade;County) and/or the AHJ (in areas other than.Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to
revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or
material fails to meet therequirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Titanium®UDL-30,Titanium'UDI.-50,RhinoRoof U10,RhinoRoof U20,Titanium UDL25
z
Synthetic Underlayments
LABELING:Each unit,shall bear a permanent label with the manufacturer's name or logo,city,state and following
statement: "Miami-DadelCounty Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
F
INSPECTION:A copy' of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No. 14-0603.18 and consists of pages i through 4.
The submitted documentation was reviewed by Alex Tigera.
l
m
NOA No.:184814.09
MIAMMA (1 1 cnr
ul 2. j Expiration Date: 08/08/23
} ! Approval Date: 08/30/18
Page I of 4
C
i
ROOFING COMPONENT APPROVAL
Category: Rdofing
Sub-Category: Underlayment
Material: Polypropylene
SCOPE:
This acceptance is for,Titauiume UDI-30,Titanium'UD1-50,.....RhinoRoof U20,Titanium UDL25,and
Synthetic Underlayments as described in this Notice of Acceptance,for use with approved prepared roof assemblies
where ASTM D226 Typelunderlayment is specified and installed with prescribed approved fasteners and fastener
densities.Designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the
Florida Building Code
PRODUCT DESCRIPTION:
Test Product
Product Dimensions Specification Description
Titanium UDL-30 48"x 250'rolls ASTM D226 Woven synthetic polymer underlayment with two
Type I&II sides coated with UV protected and slip resistant
Manufacturing
Location #1 polymer stabilized polypropylene on both sides.
Titanium®UDL-50 48"x 250'rolls ASTM D226 Woven synthetic polymer underlayment with two
Manufacturing Type I&Il sides coated with UV protected and slip resistant
Location#I polymer stabilized polypropylene on both sides.
I
j RhinoRoof U20 42"x 286'rolls ASTM D226 Woven synthetic polymer underlayment with two
Manufacturing Type I and II sides coated with W protected and slip resistant_
Location #1 polymer stabilized polypropylene on both sides.
Titanium UDL25 i 48"x 250'rolls ASTM D226 Woven synthetic polymer underlayment with two
Manufacturing e Type I and II sides coated with UV protected and slip resistant
Location #1 polymer stabilized polypropylene on both sides.
RhinoRoof U10 42"x 286'rolls ASTM D226 Woven synthetic polymer underlayment with two
Manufacturing i Type I&II sides coated with LTV protected and slip resistant
Location #1 polymer stabilized polypropylene on both sides.
1
&MANUFACTURING LOCATIONS:
I. ML2
I �
�fHfAMI DADS COUNTY ( NOA No.:18-0814.09
JAPPROYMP Expiration Date: 08/08123
! Approval Date: 08130118
Page 2 of 4
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Revort Date
Intertek Testing Services #3031783 TAS 104 02/19/03
I 3119607COQ-003B ICC ES AC48 02/20/08
3124826-01 ASTM E108 02/19/08
3124826MID-007 ASTM E108 02/25/08
311801000Q-003 ASTM D226 02/20/08
3130639COQ-002A ASTM D226 02/20/08
3146738COQ-003A ASTM D226 06/20/11
3146738COQ-003B ASTM D 1876/TAS 117 03/28/08
101465036COQ-001 ASTM D1970 06/27/14
100539395COQ-006 ASTM D226 06/02/14
101863861COQ-OOIA ASTM D226 10/28/14
i 101823107COQ-011 ASTM D226 12/09/14
Trinity ERD I15010.05.10 ASTM D4798/D226 05/14/10
I
138010.08.11 ASTM D226 08/11/11
135520.08.11 ASTM D2523/D1781 08/17/11
INSTALLATION SPECIFICATIONS:
Titanium@ UD1-30, Titanium" UDIr50, RhinoRoof U10, RhinoRoof U20, and Titanium UDL25 Synthetic
Underlayments
1, Titanium®UDL`30,Titanium'UDL-50,RhinoRoof U10,RhinoRoof U20,and Titanium UDL25 Synthetic
Underlayments shall be installed in strict compliance with applicable Building Code.
2. TitaniumQD UDL-30,Titanium®UDL-50,RhinoRoof U10,RhinoRoof U20,and Titanium UDL25 Synthetic
Underlayments shall be installed with a minimum flinch head lap in a shingle layer fashion.
3. Titanium®UDI.-30,Titanium®UDL-50,RhinoRoof U10,RhinoRoof U20,and Titanium UDL25 Synthetic
Underlayments shall be fastened with Miami Dade approved corrosion resistant tin-caps and 12 gauge 1 '/a"
annular ring-shank nails,spaced 6"o.c.at all laps and three staggered rows fastened 12"o.c.in the field of the
roll.
4. TitaniumO UDL-30,Titanium®UDL-50,RhinoRoof U10,RhinoRoof U20,and Titanium UDL25 Synthetic
Underlaymentsmay be used with Asphaltic shingles,Wood shakes and shingles,Non-structural metal roofing,
and quarry slate.Titanium@ UDL-30,Titan iumg UDL-50,RhinoRoof U10,RhinoRoof U20,and Titanium
UDL25 Synthetic Underlayments shall not be used as roof file underlayments.
5. For Roof Tile applications;may be used as an anchor sheet in roof file applications when used in combination
with a top membrane layer,consisting of a Miami Dade approved TAS 103 self-adhering underlayment.(See
current NOA listing of approved TAS 103 self-adhering underlayment for installationguidelines and
limitations of use)_
6. For fire classification of specific roof assemblies using Titanium®UDL-30, Titanium@ UDL-50,RhinoRoof
U10, RhinoRoof U20, and Titanium UDL25 Synthetic Underlayments refer to a current Approved Roofing
Materials Directory for fire ratings of this product-
I
i
i '
NOA No.:18-0814.09
�� Q
Ln�
tADE CQtltdTY �
• • ���t Expiration Date: 08/08/23
Approval Date: 08/30/18
Page 3 of 4
BUILDING PERMIT REQUIREMENTS:
Application for b Olding permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly
evaluate the installation of this material.
LIMITATIONS:
1. Fire classification is.not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code.
3. Titanium® UDLi,3O, Titanium@ UDL-50, RhinoRoof U10, RhinoRoof U20, and Titanium UDL25 Synthetic
Underlayments shall be applied to a smooth,clean and dry surface with deck free of irregularities.All nails in
the deck shall be carefully checked for protruding heads. Re-fasten any loose decking panels. Sweep the deck
thoroughly to remove any dust and debris prior to application.
4. Titanium@ UDL730, Titanium® UDL-50, RhinoRoof U10, RhinoRoof U20,and Titanium UDL25 Synthetic
Underlayments shall not be hot mopped,refer to manufacturer's published literature for product compatibility.
5. Titanium® UDLL30 Titanium@ UDL-50,RhinoRoof U10, RhinoRoof U20, and Titanium UDL25 Synthetic
Underlayments shall not be applied over an existing roof membrane as a recover system.
6. Titanium® UDL-130, TitaniumQ UDL-50, RhinoRoof U10, RhinoRoof U20, and Titanium UDL25 Synthetic
Underlayments shall not be left exposed as a temporary roof for longer than 30 days of application.
7. TitaniumID UDL60, Titaniuru@ UDL-50, RhinoRoof U10, RhinoRoof U20, and Titanium UDL25 Synthetic
Underlayments are components used in roof system assemblies. Roof system assemblies are approved under a
specific Notice of Acceptance. Refer to Prepared Roofing system Product Control Notice of Acceptance for
listed approval of this product with specific prepared roofing products.
8. Titanium4D UDL-30, Titanium@ UDL-50,RhinoRoof U10,RhinoRoof U20, and Titanium UDL25 Synthetic
Underlayments may be used with any approved roof covering Notice of Acceptance listing Titanium®UDI,
30,Titanium®UDL-50,RhinoRoof U10,RhinoRoof U20,and Titanium UDL25 Synthetic Underlayments as
a component part of an assembly in the Notice of Acceptance. If Titanium®UDL-30, Titanium®UDL-50,
RhinoRoof U10,!RhinoRoof U20,and Titanium UDL25 Synthetic Underlayments are not listed,a request may
be made to the Authority Having Jurisdiction(AID) or the Miami-Dade County Product Control Department
for approval provided that appropriate documentation is provided to detail compatibility of the products,wind
uplift resistance,1 and fire testing results.
9. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo
and the follow*mg statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County
-Product Control Seal as shown below.
MIAMI•DADE CO
�Lma&*alus
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61G20,'3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
MIAMaDADE NOA No.;18-0814.09
JAPPROVED Expiration Date: 08/08/23
Approval Date: 08/30/18
Page 4 of 4