Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Drawing
� 5 v�za-: t ,""W •�'- 7' 1. •;.�[;�� ,e+; t�•, k moi`--�' a Revies FILE f u.* DATE' � / rle . - Facility Survey Customer & Total Facility Information Select Event 02/11/2019 NOSV- Nilfisk- Fans revisit- 7337 COMMERCIAL CIR FORT PIERCE, FL 34951 - Shaun Spring, shaun.spring@nilfisk.com 3869652487 Opportunity Name: Nilfisk - Fans revisit Quotation Account: Nilfisk 733Tommercial Cir. FL Contact: Shaun Spring shaun.spring@nilfisk.com Site Visit FORT PIERCE FL NOSY Did you use the Facility No Layout Tool? If no, please explain why: Will use tool later Date of Site Visit 02/11/2019 Total Facility Sq Ft: 80000 Lease or Own Own Building Heated: No Building HVAC/Cooled: No Last Lighting Retrofit 1999 (Year): Current Lighting: Metal Halide Weekly Operating Hours: 50 Facility is military base, No church, school, residence or construction site: No Ass Packaging No Title: First Name: Shaun Last Name: Spring Did you meet with this No contact? Phone Number: 3869652487 Email: shaun.spring@nilfisk.com State: FL Country: us What office are you Us affiliated with? Type in the Name of the Fabrication;assembly Areas you Visited (separated by a semi- colon): Area One 1. Area Area Details Area Name: Fabrication Describe what the Area Crane not in use, fabrication area is mostly needing cooling in is being used for: punch and welding area. Length of Space (ft, 250 ENTER #s only): Width of Space (ft, 144 ENTER #s only): Area Sq Ft 36000 Peak Height: 27.5 Eave Height: 22 Deck Height: 26 Distance between 6 purlins/bar joist (ft, ENTER #s only): Column Spacing: 25 Area Picture: Click here to open the image Area Picture Notes: Fab area over crane (crane not in use)) Area Picture2: Click here to open the image Area Picture2 Notes: Top of crane beam 18' mounting height 25' Area Picture3: Click here to open the image Area Picture3 Notes: Mounting structure Area Picture4: Click here to open the image Area Picture4 Notes: 480y panel 1 option Area Picture5: Click here to open the image Area Picture5 Notes: Panel 2 option Area Picture6: Click here to open the image Area Picture6 Notes: Panel 2 Area Picture7: Click here to open the image Area Picture7 Notes: Panel 1 Lighting: No Fans: Yes Height to attachment 25 point: Mounting Structure Z-Purlin Mounting Location: Click he-- to open the image Mounting Location Crane will be moved no longer in use Notes: Additional Photo of Click here to open the image Mounting Location: Additional Photo notes: Fan Area Layout Picture Click here to open the image Fan Area Layout Notes Closer box with space 480y/277 Fan Quote Request (Qty) Fan Type, Size, 408y/277 3 phase Mount, Ext Tube, Input Power: 24' pfx 4' tube Fan Adders: Z-Purlin Kit Fan Installation Fan Install: Yes Level of Installation: Level 3 Lift needed: Yes Building Lift Accessible Yes Type of Lift Needed (ft up to 30' Scissor Lift are to the Mounting Structure): Controller to Fan: In Scope (Average 150' or less) Enter Electrical Panel details if you did not enter them in the Lighting section. Brand of panel: Series 2 general electric Voltage and Phase: 408y/277 3 Electrical Panel Photo Click here to open the image (Take a Step Back): Electrical Panel Photo Click her- to open the image (ID Tag): Electrical Panel Photo Click her- to open the image (Schedule): Electrical Panel Notes: Adders: 2. Area Area Details Area Name: Assembly Describe what the Area Assembly is being used for: Length of Space (ft, 360 ENTER #s only): Width of Space (ft, 142 ENTER #s only): Area Sq Ft 51120 Peak Height: 28 Eave Height: 21 Deck Height: 25 Distance between 6 purlins/bar joist (ft, ENTER #s only): Column Spacing: 25 Area Picture: Click here to open the image Area Picture Notes: Main space Area Picture2: Click here to open the image Area Picture2 Notes: Area Picture3: Click here to open the image Area Picture3 Notes: Level 2 install crane area Area Picture4 Notes: Area Picture5 Notes: Area Picture6 Notes: Area Picture7 Notes: Lig kiting: N o Fans: Yes Height to attachment 22.5 point: Mounting Structure I-Beam (10 Mounting Location: Click here to open the image Mounting Location I beam mount level 2 install power hanging is dedicated not Notes: used Additional Photo notes: Fan Area Layout Notes Fan Quote Request (Qty) Fan Type, Size, 24' pfx no tube I beam mount Mount, Ext Tube, Input Power: Level 2 install using existing non used power on dedicated circuit Fan Adders: Fan Installation Fan Install: No 3. Area Area Details Area Name: Small package are Describe what the Area Packing and shipping is being used for: Length of Space (ft, 150 ENTER #s only): Width of Space (ft, 30 ENTER #s only): Area Sq Ft 4500 Peak Height: Eave Height: Deck Height: Distance between purlins/bar joist (ft, ENTER #s only): Column Spacing: Area Picture: Click here to open the image Area Picture Notes: Pivot area Area Picture2 Notes: Area Picture3 Notes: Area Picture4 Notes: Area Pictures Notes: Area Picture6 Notes: Area Picture7 Notes: Lig hting: N o Fans: Yes Height to attachment 10 ft column air eye point: Mounting Structure I-Beam (7 Mounting Location: Click here to open the image Mounting Location 6 aireye column mounted Notes: Additional Photo notes: Fan Area Layout Notes Fan Quote Request (Qty) Fan Type, Size, 6 aireye 30" column mounted Mount, Ext Tube, Input Power: Fan Adders: Fan Installation Fan Install: No 4. Area Area Details Area Name: Assembly Describe what the Area Assembly area 2 fans is being used for: Length of Space (ft, 109 ENTER #s only): Width of Space (ft, 98 ENTER #s only): Area Sq Ft 10682 Peak Height: Eave Height: Deck Height: Distance between 6 purlins/bar joist (ft, ENTER #s only): Column Spacing: 25 Area Picture: Clicl< here to open the Image Area Picture Notes: Side view of assembly area Area Picture2 Notes: Area Picture3 Notes: Area Picture4 Notes: Area Pictures Notes: Area Picture6 Notes: Area Picture? Notes: Lig hting: N o Fans: Yes Height to attachment 25 point: Mounting Structure Z-Purlin Mounting Location: Click here to open the irnage Mounting Location Mounting 1 Notes: Additional Photo of Clid< here to open the image Mounting Location: Additional Photo notes: Mounting 2 Fan Area Layout Notes Fan Quote Request (Qty) Fan Type, Size, 2 18' pfx Mount, Ext Tube, Input Power: One over crane has 3' tube One not over crane 2'tube Z purloin install level 3 Fan Adders: Z-Purlin Kit Fan Installation Fan Install: Yes Level of Installation: Level 3 Lift needed: Yes Building Lift Accessible Yes Type of Lift Needed (ft up to 30' Scissor Lift are to the Mounting Structure): Controller to Fan: In Scope (Average 150' or less) Enter Electrical Panel details if you did not enter them in the Lighting section. Brand of panel: Ge Voltage and Phase: 408y/277 3 Electrical Panel Photo Click here to open the image (Take a Step Back): Electrical Panel Photo Clickhere to open the image (ID Tag): Electrical Panel Photo Click her` to open the image- (Schedule): mage(Schedule): Electrical Panel Photo Click here to open tide image (Close Up): Electrical Panel Notes: Open breakers 2 fans on same circuit and control Adders: Next Steps Request for Proposal Check if you need a Yes Request for Proposal RFP Status Open - Full Lighting Proposal (EngApp Required) RFP Comments: Full lights and fans Install Price Quote Request Do you need an install Yes price quote Check if you need an Yes install price quote Why is an install price Electrical Perm its,Opportunities over$100,000 quote needed? Explanation of install Bidding for for fan and light job price quote Engineered App Note: If you are creating a Request where Status = "Open - Full Lighting Proposal"then you MUST create an EngApp. If you know exactly what is required for the Lighting Proposal then place Request Status in "Ready for Full Lighting Proposal". Check if you need an Yes EngApp Type Fan Recommendation + Lights Inside Sales POC: corey.cleaver@bigassfans.com Corey Cleaver Notes from Submitter: Call Jon Mode with any questions Lighting Goal: Energy Savings Expedite Needed: Yes Reason for Expedite: Budgetary approved and Beach current lighting quote before signing Deadline: 02/13/2019 Competition Is this job competitive? Yes 1. Competition Competition present for: Lights Competitor Select: Other to LED Competitors Unit Price 395 (#s only): Competitors Install Price 0 (#s only): Competitor Strengths: LED $65,000 installed Competitor Not big ass fans lights, less warranty, lower quality Weaknesses: Other to LED Type: LED Competitor Spec'd: No (Votes: LED replacement one for one Site Visit Summary Potential purchasing 03/11/2019 date? Purchasing process? Need approval from corporate corporate has lots of locations and has already Approved improvement funding Who is driving the Corporate project? Presentation Schedule List Primary Contact for Cory Cleaver to submit proposal to Shawn for submission to Scheduling Presentation corporate & Attendees: Timeframe: PO Expected > than 90 days Explain: Next Steps: Assign yourself or Inside POC a task Do you need to assign a No task? 31- 77' HIGH VOLUME LOW SPEED FAN SCHEDULE 0 ELECTRICAL BL NEL SCHEDULE E-201 3 y p rnl oi ELECTRICAL ONE-LINE OIAGRAh1-BUILDING EAST ELECTRICAL ONE-LINE DIAGRAM-BUILDING_WEST g mmarow.. mvmaw.w.a a.wro�.,. anmc�o....ouc 5c I ELECTRICAL I ONE UNE DIAGRAMS E-202 NEIRAL NOTES TAG OF OESCFIPRON___. 1.E FAN55AHALLBEI TLMT LENG Y.INALL UNTTN 6RAC CMPOTH NAECgSiR En PRIIO .1 FAN SCHF_DUL� 1. VERIFY EI(TENGIOF S St LE AT LEAND17AFF. GBRaC1ETn1TH MIWUFACNRER PRIOR IOORDERINO. I I, —1 1 ]C PON .LXS.O 4. FANSSHALLNOTSEMOUNTEDN(THINM MMESTHEFANDIAMETEROFE)D TORRE111RN.VRIKMA ,ANDSYALLNOTDEINDIREUUNEOFDISCHARGEOFHJACEOUIPMENr. 'I BIGASS I: EAF01 J 18'PONERFOILX0.0 EXTENSION WEBS 4'OR LONGER SHALLNITH BE INSTALLED GUY IMRES PER THE MIWUFACNREITS INSTALLATION REOUIR(:MENTS.(EXCLUDING HAIKU) '. I BAFBS fi SP.NREYE 6.5. FANS SHALL BEAT THE SAME LEVEL OR HIGHER THAN RADIANTHEATERS AND OUTSIDE THE MINIMUM CLEARANCE TO CCMBLlST1ELES. it FANS lei' T. FANS SHALL BE ATLEASTT AND ONEJALF TIMES THE DBIMETER OF THE LARGESTFAN AWAY FROM NEIGHBORING FANS. O :f B' m m TOP OF CRANE BEAN. 05—8• 11• D-O y . THE CRANE IS GOING 24'X3.0—4'drop e ; C MAX C r TO BE TAKEN DOWN PER H l7 O CUSTOMER (CRANE IS NRT GN yI�' tube _ __-- -- _-- -- _ -- --..-----Level 2 install—do .. LAYDUT7 -- not include ir, -� < calculations ] m Q 3 tube o 0 0 '143 B' 9-6' - � _ I � •z• ' I p 8 C 18'X3.0-3'drop .---. 21 JJJ222 246 4 35B'-B' RIDGE CRANE`' '_6'_ B46 FABRICATION tube ASSEMBLY SECTION A SECTION 1 SELTICN L N z °- - — --- --- p it i; BC --------------------- "W --------------------- AM ,I 358'-8" BRIDGE CRANE---- `_- - - - - ASSEMBLY DETAIL VIEW OF 30" AIREYES a ------------------ I -I I ------------------- ----------------- o j Ij � f] it IU`l I A S � �d o a9a 0 9 i I I I I _ � I rnBAS-NILFISK .�,,.,,.... jo 1 pF ? A Pn en+191 /,• � F � O,O PHJJCCf—191118 i 8 ELECTRICAL GENERAL NOTES: .c�.,a nn..n ��, a '_ •-. - ;i Q ELECTRICAL KEYED NOTES: a � — db i I i I ENLARGED ELECTRICAL I FLOOR PLAN 01 EN FI GEOELECTRICALFLOORPLAN-BUILDING WEST E-102 3 i' g ELECTRICAL GENERAL NOTES: D ELECTRICAL KEYED NOTES: 6- �wsravmiuwcIX mwrara I = �u �-� ENLARGED ELECTRICALUFLOOR PN y 0.l ENLARGED ELECTRICAL FLOOR PLAN-BUILDING EAST E-103 VVeeyyyy a[Gds.d`Sd32�aa"2Y;�''nwV4�B��',jYAR3Ae^4'y`d§n^A43y�O�A��Fj6GAQPed�d&g�oRdw�4w•4ycR"PBeo�a2t"�i•diSSGF�o$iA`siii3273itltl: n 55 E SS D £ D �s�,.,��� � � �� �"°sg��'�•j'E�Y; dd d�g�•���g4��Rg� ���1 HIP N pp T o yea Y �� a q Q �` q � cg °° I � � • ro • • D Iad EAg g 4548 o 0 5 � ,��.({ m o a 0 o • m l ` ( 15w z $g 66gg gg g 1111 II ggltl IEI'"' D g D 11H It I 353 g g a Rw � f 3 Y4Yii 4 wr o it r. m II I Fz,.i° i i 1�Yn..d4 g z Iii�,Y����� Fe j3� ������ � � � 3 �l ii it i�� � '4 �l Fe7 ��'6$Y ��il t �:q ji iI!,, g$ � 7SYi. Y Jit�q§§ R4sY ;Y i # 11 a F �j q �mKm Tqf, BAS-NILFISK 4 •"''•"" d..a.t. 'nssGO,/xEwcNlrnwne •i,•.,u. e OSn$ Fi.wERce.RJiBst ,...+ww,a � F ��� E ov Ywhcr—Iwlun i Property Card Page 3 of 3 Number Issue Date Description Amount Pee C52338 Mar 1,1990 Commercial New $1,387,462 $1,387,462 Construction C52957 Jun 19,1990 Sprinkler System $29,000 $29,000 C92-06407 Nov 20, 1992 Additions to $810,600 $810,600 existing construction C97-020501 Mar 4,1997 Alterations/Remodeling $2,400 $2,400 Notice:This does not necessarily represent all the permits for this property. Click the following link to check for additional permit data in Saint Lucie County All information is believed to be correct at this time,but is subject to change and is provided without any warranty. ©Copyright 2019 Saint Lucie County Property Appraiser.All rights reserved. https://www.pasle.org/RECard/ 6/12/2019