HomeMy WebLinkAboutRevisions (2) r
OFFICE USE ONLY:
DATE FILED: �-t PERMIT# 1906-0012
REVISION FEE: 1 ". RECEIPT#
PLANNING& DEVELOPMENT SERVICES
BUILDING&CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
FORT PIERCE;FL 34982.5652 RECEIVE®
(772)462-1553
APPLICATION FOR BUILDING PERMIT REVISIONS JUN 19 2019
PROJECT INFORMATION ST.,Lucie County, permitting
LOCATION/SITE
ADDRESS:
607 Brack Road, Fort Pierce, FL, USA
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
Keeping the Modified Bitenum on the Low slope roof Product approval: FL1654
Peel N Stick, and Tamko Shingles on the 3/12 roof. Product Approval:Shingles-FL18355 Peel N Stick- FL16048
Also 4ft Off Ridge Vents for the shingle roof. Product Approval:Weather Vent 18-1212.10
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: CCC1331408 ST. LUCIE CO CERT. #:
BUSINESS NAME: PDKRoofing.lnc
QUALIFIERS NAME. Dee Keihn
ADDRESS: 1299 SW Biltmore Street
CITY: Port Saint Lucie STATE: Florida ZIP: 34983
PHONE (DAYTIME): (772)528-0113 FAX:
OWNER/BUILDER INFORMATION:
NAME: Lisa Bergeron
ADDRESS:607 Brack Road
CITY: Fort Pierce STATE: FL ZIP: 34952
PHONE(DAYTIME: (772)528-0113 FAX:
ARCHITECT/ENGINEER INFORMATION:
NAME:
ADDRESS:
CITY: STATE: ZIP:
PHONE (DAYTIME): FAX:
SLCCC: 9/23/09
Revised 06/30/17
r
RECEIVED
JUN 19 2019
MIAMI-DADE COUNTY
Fgl�pigpE sr. Lucie County, Permitt0 UCTCONTROLSECTION
i 11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NPA) www.miamidade.gov/economy
Southeastern Metals Manufacturing Company,Inc.
11801 Industry Drive
Jacksonville,FL 32218
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use.of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Weather Vent
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered atter a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, arid/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No. 13-0814.08 consists of pages I through 3.
The submitted documentation was reviewed by Freddy S'emino
FOR
pUg4CE NOA No.:18-1212.10
M 1 ECO CODE �;� Expiration Date: 04/15/24
® ®CCOUNTYApproval Date: 01/31/19
ft 9��J 1*1% Page 1 of 3
i
ROOMG A'SSEMBLY APPROVAL
Category: Roofing
Sub-Category: Ventilation
Material: Steel
NVlinimum Slope: 2:12
TRADE NAMES OF PRODUCTS-MANUFACTURED OR LABELED•LPD BY APPLICANT:
Manufactured by Teat Product
An._ a10 Specifications Deacrbtion
Weather vent Vent:4-%"�x 19"x 46" TAS 100 Galvanized metal roof vent
Deck Flange:2-V'x 52"
Thickness:0.0217 inch.
MANUFACTURING LOCATION
L Jacksonvffle,.FL
EVIDENCE SUB1VlITTEb
Tea_t Agency _Test IdentfHer Teat Name/Renort Date
PRI Asphalt Technologies,Inc. TAS 100 SEM-002-02-01 08/14/03
ICC-ES AC132 SEM-027-02-01 01/07/14
APPROVED APPLICATIONS:
Deck Type: wood
Deck Description: 15/3z"or greater plywood or wood plank
System Type A: Mechanical attachment of vent
Cutout: Mark a 3W'x 46"opening centered between layout lines and aligned minimum-6 inches from
the ridge. Set blade to thickness of sheathing and out opening. Brush away sawdust and debris.
Installation., Vents should be evenly spaced on the rear slope of the roof-
.
Center vent in opening and set it in a Mr thick of an approved ASTM D 4586 asphalt roofing
cemmrt. Secure vent to the roof deck with 1-%4"galvanized ring shank roofing nails spaced
approxi 8"o.c.and 1"from the outside edge ofthe flange. Use a minimum.of 18 nails per vent.
Seal all nails and vent flange with an approved ASTM D 4586 roofing cement. (See drawings
herein).
:Net Free Area: 99 square inches.
NOA No.:18-121M8
Faphstion Date. 04/15/24
Approval Date: 01/31/19.
Page 2 of 3
M
p
Iii MATIONS:
1. Refer to applicable budding code for requiredventilation.
2. Weather Vent shall comply with the manufacttnes cunIntpublished application instructions and the
requirements set forth in the applicable building code.
3. This acceptance is for installations
4. Weather Vent shall not be installed on roof mean heights greater than 33 feet.
S. All products listed herein shall have a quality assurance audit in accordance with the Florida.Buil ft
Code and Rule 61(324-3 of the Florida Administrative Code.
6. All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of
the manufacturer's name or logo,city,state,and following statement:'Miami-Dade County Product
ControlApproved'or the Miami Dade County Product Control Seal.as shown below:
iAPPROVEDI
DRAWINGS
W ROOF FLANGE
BMRNAL WND
BAFFLE
i • • ! • i !
ROOF FLANGE NA MACBMa
! i
. ! i . i i • • •
END OF TSM ACCEPTANCE
NOA Noa04/12.10
E�imi3ou D� 04/15/24
Approval Bate: 01131/14
Page 3 d3
i
s
8/2312018 Florida Building Code Online
t:r e
a s
SCIS Home Log In User Registration Hot Topics i Submit Surcharge Stats&Facts i Publications Contact Us SCIS Site Map Links Search
Florida �P'
4'. 1 1` iProduct Approval RECEIVED 4
--` ' JUN 1 g 2019
Product Aooroval Merin>Product or Aooliotion Search>Aoollcatlon List>Appliption Detail
0m FL# FL16048-R6 ST. Lucie County, Permitting
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived /Pr%opy
Product Manufacturer Tri-Built Materials Group,LLC
Address/Phone/Email PO Box 70
Rutherford,N3 07070
(800)516-1485
david.ruiz@tribuiltmg.com
Authorized Signature David Ruiz
david.rulz@tribuiltmg.com
Technical Representative David Ruiz
Address/Phone/Email 250 Route 17 North
East Rutherford,N3 07073
(201)842-2449 5
david.ruiz@tribuiltmateriaisgroup.com
Quality Assurance Representative ,
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 07/18/2020
Validated By John W.Knezevich,PE
d Validation Checklist-Hardcopy Received
Certificate of Independence FL16048 116__COI 2017 01 COI Nieminen.pd
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2015
ASTM G155 I 2005
FM 4474 2011
FRSA/TRI April 2012(04-12) 2012
UL 1897 2012
Equivalence of Product Standards
Certified By
http://www.floridabuilding.org/prlpr�_app_dtl.aspx?param=wGEVXQwtDgtFPmdYiNDWrwipmtAnR8jvgFYHTk4FeCxcgVtRhfvMw%3d%3d 1/2
8123/2018 Florida Building Code Online
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 09/25/2017
Date Validated 10/01/2017
Date Pending FBC Approval 10/03/2017
Date Approved 12/12/2017
Summary of Products
FL# Model,Number or Name Description
16048.1 TRI-BUILT Roof Underlayments Self-adhering,modified bitumen roof underlayments
Limits of Use Installation Instructions
Approved for use In HVHZ:No FL16048 R6 II 2017 09 FINAL ER TRI-
Approved for use outside HVHZ:Yes BUILT UNDERLAYMENTS FL16048-R6.pdf
Impact Resistant.N/A Verified By: Robert Nleminen PE-59166
Design Pressure:+N/A/-150 Created by independent Third Party:Yes
Other:1.)The design pressure noted herein pertains to use of Evaluation Reports
foam-on tile systems overtop the self-adhering underlayment FL16048 R6 AE 2017 09 FINAL ER TRI-
for one particular application.See ER Section 5.6.4 for details. BUILT UNDERLAYMENTS FL16048-R6.Ddf
2.)Refer to ER Section 5 for other Limits of Use. Created by Independent Third Party:Yes
Back Noxi
Contact Us:t 2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida Is an AVEEO employer.Copyright 2007-2013 State of Florida.::Private Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address it they have one.The emalls
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,FS.,please click here.
Product Approval Accepts:
F59. Wq
® .0 a
Credit Card
Safe
http:/Iwww.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtFPmdYiNDWr% ipmtAnRBjvgFiYHTk4FLCxcgVtRhfvMwp/o3d%3d 212
t
EXTERIOR RESEARCH&DESIGN,LLC.
Certificate of Authorization#9503
TRIp �I�(E�® 353 CHRISTIAN STREET,UNIT#13
�V If OXFORD,CT 06478
(203)262-9245
EVALUATION REPORT
TRI-BUILT Materials Group,LLC Evaluation Report A42960.10.12-116
PO Box 70 FL16048-116
Rutherford,NJ 07070 Date of Issuance:10/25/2012
(800)516-1485 Revision 6: 09/25/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6u' Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: TRI-BUILT Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT:The 1 Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6. `
Prepared by: •\�qp�\Irr!�t^n,;
Robert J.M.Nieminen,P.E. �' s:; �;;ti;;�
. ,,�,•,�,..• The facsimile seal appearing was authotlted by Robert Nieminen,
Florida Registration No.59166,Florida DCA ANE1983 P.E.on 09/25/2017.This does not serve as an electronically signed
document.
CERTIFICATION OF INDEPENDENCE:
1. Trinity ERD does not have, nor does it intend to acquire or will it acquire, a financial Interest in any company manufacturing or
distributing products it evaluates.
2. Trinity)ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nleminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nleminen,P.E.does not have,nor will acquire,a financial interest In any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
t
S
�TRINrry'ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: TRI-BUILT Roof Underlayments, as produced by TRI-BUILT Materials Group, LLC, have
demonstrated compliance with the following sections of the 61h Edition(2017)Florida Building Code through testing
in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/
Conditions of Use set forth herein.
2.• STANDARDS:
Section Property Standard Year
1504.3.1 Wind Resistance FM 4474 2011
1504.3.1 Wind Uplift UL 1897 2012
1504.6 Accelerated Weathering ASTM G155 2005
1507.2.4/1507.1.1,1507.2.9.2 Physical Properties ASTM D1970 2015
1507.3.3 Physical Properties FRSA/TRI April 2012(04-12) 2012
3. REFERENCES:
Entitv Examination Reference Date
ERD(TST6049) Physical Properties S40540.02.13-1 02/19/2013
ERD(TST6049) Physical Properties 540540.11.13 11/19/2013
ERD(TST6049) Physical Properties 540540.03.14 03/26/2014
ERD(TST6049) Physical Properties 544870.04.14-2 04/02/2014
ERD(TST6049) Physical Properties 544870.04.14-3 04/02/2014
ERD(TST6049) Physical Properties 544870.04.14-1 04/10/2014
ERD(TST6049) Physical Properties 544870.04.14-4 04/10/2014
ERD(TST6049). Physical Properties S43530.02.14-1-R3 05/14/2014
ERD(TST6049) Physical Properties 543530.05.14 05/28/2014
ERD(TST6049) Physical Properties 540540.10.14 10/31/2014
ERD(TST6049) Physical Properties SC7645.02.15 02/13/2015
ERD(TST6049) Accelerated Weathering SC8520.04.15 05/27/2015
ERD(TST6049) Wind Resistance SC14045.05.17-Ri 06/07/2017
UL,I.I.C.(QUA9625) Quality Control Multiple-Listing R16814 12/10/2015
UL,LLC.(QUA9625) Quality Control Service Confirmation Exp.07/18/2020
4. PRODUCT DESCRIPTION:
4.1 Tri-Built Sand-R SA Shingle Underlayment Is a self-adhering, glass-mat reinforced, sand-surfaced, SBS
modified bitumen roof underlayment,with a 36-inch sheet width;meets ASTM D1970.
4.2 Tri-Built S/A HT TU Underlayment is a self-adhering, non-woven polyester fabric surfaced, SBS modified
bitumen roof underlayment;meets ASTM D1970 and FRSA/TRJ April 2012.
4.3 Tri-Built Smooth HT S/A Underlayment is a self-adhering, glass-mat reinforced, film-surfaced, SBS
modified bitumen roof underlayment;meets ASTM D1970.
.5. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
Exterior Research and Design,LLC Evaluation Report A42960.10.12-116
Certff7cate of AuthoA:atlon#9503 6T"EDITION(2917)FB6 NON-HVHZ EVALUATION FL16048•R6
TRI-BUILT Roof Underlayments,(800)516-1485 Revision 6;09/25/2017
Page 2 of 6
TRINrry!ERD
5.4 TRI-BUILT Roof Underlayments may be used with any prepared roof cover where the product is
specifically referenced within FBC approval documents. If not listed, a request may be made to the
Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the
prepared roof covering.
5.5 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIoNs
Underlayment Asphalt Nall-On Tile Foam-On Tile Metal wood Shakes Slate
Shingles &Shingles
Tri-Built Sand-R SA Shingle\
Underlayment rj_ Yes No No No Yes Yes
Tri-Built S/A HTTU Yes Yes Yes Yes Yes Yes
Underlayment See 5.5.1
Tri-Built Smooth HT S/A Yes No No Yes Yes Yes
Underlayment I i i
5.5.1 "Foam-On Tile"is limited to use of the following Approved tile adhesives/underlayment combinations.
TABLE IA:ALLOWABLE TILE ADHESIVE/UNDERLAYMENT COMBINATIONS)
Adhesive Florida Product Approval Underlayments
ICP Adhesives Polysetm AH-160 FL6332 Tri-Built S/A HTTU Underlayment
DowTileBond`" FL22525 Tri-Built S/A HTTU Underlayment
5.6 Allowable Substrates:
5.6.1 Direct-Bond to Deck:
Tri-Built Sand-11 SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
➢ Plywood;ASTM D41 primed plywood; OSB;ASTM D41 primed OSB;Southern Yellow Pine;ASTM D41
primed Southern Yellow Pine;ASTM D41 primed structural concrete.
While not required over plywood,OSB or Southern Yellow Pine substrates,TRI-BUILT Materials Group,LLC
recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Note-
TRI-BUILT Materials Group, LLC requires tongue-and-groove board decking be covered with plywood or
OSB prior to installation of the self-adhering underlayment.
5.6.2 Bond-to-Insulation:
Tri-Built Sand-IR SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
➢ Dens Deck Prime;SECU ROCK Gypsum-Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam-on tile systems (Tri-Built S/A HT TU Underlayment only), insulation attachment shall be
designed by a qualified design professional and installed based on testing of the insulation/underlayment
system in accordance with FM 4474,Appendix D orTAS 114,Appendix J.
j Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
Exterior Research and Design,I.I.C. Evaluation Report A42960.10.12-R6
Certificate ofAutharfzation#9S03 6m EDITION(2017)FBC NON-HVHZ EVALUATION F1.1604B-R6
TRI-BUILT Roof Underlayments;(800)516-1485 Revision 6:09/25/2017
Page 3 of 6
TRINI11( ERD
5.6.3 Bond to Mechanically Attached Base Layer:
Tri-Built Sand-11 SA Shingle Underlayment,Tri-Bulli S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
➢ ASTM D226,Type I or 11 felt.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam-on tile systems (Tri-Built S/A HT TU
Underlayment only),base layer shall be attached per minimum requirements of FRSA/TRI April 2012(04-
12).
5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems,where
the underlayment forms part of the load-path. The following wind uplift limitations apply to direct-deck
underlayment systems that are not addressed in FRSA/TRI April 2012(04-12)and are.used in foam-on tile
applications. Maximum Design Pressure is the result of testing for wind load resistance based on
allowable wind loads, and reflects the ultimate passing pressure divided by 2(the 2 to 1 margin of safety
per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012(04-12),Appendix A,Table 1A or
FBC 1609 for determination of design wind pressures.
#1 Maximum Design Pressure=-45.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: (Optional)ASTM D41 or RESISTO EXTERIOR PRIMER
Underlayment: Tri-BuiltS/A HT TU Underlayment,self-adhered.
#2 Maximum Design Pressure=-67.S psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: Soprema Elastocol 600c
Underlayment: Tri-Built S/A HT TU Underlayment,self-adhered.
#3 Maximum Design Pressure=-150.0 psf:
Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project
requirements to satisfaction of Authority Having Jurisdiction.
Deck Preparation:Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit
adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp
splinters and wood projections shall be removed/sanded.
Primer: (Optional)RESISTO EXTERIOR PRIMER
Underlayment: Tri-Built S/A HT TU Underlayment, self-adhered, shall be thoroughly roll using hand
roller and/or weighted roller to ensure there are no voids, and ensure there are no
.voids/bridging at side and end-laps.
#4 Maximum Design Pressure=-60.0 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Soprema Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1)
and tin caps(FBC 1517.5.2)spaced 6-inch o.c.at the 4-inch laps and 6-inch o.c.in three,
equally spaced rows in the center of the sheet.
Underlayment: Tri-Built S/A HT TU Underlayment,self-adhered.
Exterior Research and Design,LLC. Evaluation Report A42960.10.12-R6
CertifrcateofAuthori:ation#9503 6T"EDITION(2017)FBCNON-HVHZEVAWATION FL16048-R6
TRI-BUILT Roof Underlayments,(800)516-1485 Revision 6:09/25/2017
Page 4 of 6
UTRINRYIERD
5.6.4.1 For mechanically attached Base Sheet,the maximum design pressure for the selected assembly shall meet
or exceed that required under FRSA/TRI April 2012(0412),Appendix A,Table 3.A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1
design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an
attachment density designed by a qualified design professional to resist the elevated pressure criteria.
Commonly used methods are ANSI/SPRI WD11 FM Loss Prevention Data Sheet 1-29 and Roofing
Application Standard RAS 117. Assemblies marked with an asterisk* caFry the limitations set forth in
Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(January 2016)for,Zone 2/3 enhancements.
5.7 Exposure Limitations:
Tri-Built Sand-R SA Shingle Underlayment or Tri-Built Smooth HT S/A'Underlayment shall not be left
exposed for longer than 30-days after Installation
Tri-Built S/A HT TU Underlayment shall not be left exposed for longer than 180=days after installation.
5.8 Tile Slinpaee_Limitations(TAS 103 per FRSA/TRI April 2012(04-121):
When loading roof tiles on the underlayment in direct-deck tile assemblies,the maximum roof slope shall
be as follows. These slope limitations can only be exceeded by using battens during loading of the roof
tiles.
TABLE 2: TILE SLIPPAGE LIMITATIONS FOR D1RECr-DECit TILE-INSTALLATIONS
Underlayment Tile Profile Staging Method Maximum
Slope
Flat Max.10-tile stack 6:12
Lugged Max.W-tile stack 5:12
Max.10-tile stack(bottom 2-tile stack
shall be inverted,followed by 8 tiles high 6:12
on slope,as shown below)
Tri-Built S/A HT TU 1-
Underlayment
Lugged
Exterior Research and Deslgn,LLC. Evaluation Report A42960.10.12-R6
Certificate of Authnd:otion#9503 6TM EDITION(20171 FBC NON-HVHZ EVAWATION FL16048-RO
TRI-BUILT Roof Underlayments;(800)516-1485 Revision 6:09/25/2017
Page 5 of 6
a
r
TRINITY►ERD
6. INSTALLATION:
6.1 TRI-BUILT Roof Underlayments'shall be installed in accordance with TRI-BUILT Materials Group,-LLC
published installation requirements subjectto the Limitations set forth'in Section 5 herein and the '
specifics noted:below.
6.2 Re-fasten any loose decking panels;-and check for protruding nail heads: 'Sweep the substrate thoroughly-
to.remove any dust and debris,prior to application,and prime the substrate(if applicable).
6.3 Tri-Built Sand-R SA'Shinele UnderlayMent.Tri-Built S/A HT TU Underlavmerit or Tri-Built Smooth HT S/A
•Underlavment•
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlaymerit in FBC Table
1507.1.1 for the type of prepared roof covering to be installed..
6.3.2 Non-Tile applications: v
Whilepriming,is optional,.TRI-BUILT Materials Group,LLC recommends priming the deck if the final roof
cover is not slated for installation within 24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of mernbrane and peel back the first 3
ft of release film.
Adhere the exposed partto..the substrate and unroll the remaining membrane as far as possible.
Once the.entire length.of membrane is in place, peel-off the release film.diagonally while holding the
membrane tight. Firmly roll,broom or hand�press the membrane into place to achieve a bond.
Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-
inches and staggered not less than 2-ft from vertical seams imthe course below,sealed in accordance with
TRI-BUILT,Materials Group,LLCrequirements.
When-installing at slopes-above-8:12, TRI-BUILT Materials Group, LLCrrecommends back-nailing in the
overlap area at the top of the sheet at 124nch o.c.
'For Valleys and Ridges: Cut�6nderlayment into 4 to 6 foot lengths.Pe
eFthe release paper and center sheet
over valley orridge. Drape and press sheet into place, working from the center of the.valley or ridge in
each direction.-For•valleys,apply the sheet starting at the lowest point'and.work upward.
6.3.3 - Tile Applications(Tri-Built S/A.HT TU Underlayment onW.
Reference is made to FRSAJTRI April 2012 (04-12) Installation Manual and Table 1 herein, using the
instructions noted above as a guideline.
'For foam-on tile applications,reference is made to Section 5.6.4 herein for wind resistance limitations that
fall.outside the scope of FRSA/TRI April 2012(0412).
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment: See Tattle 2'herein, and TRI-BUILT Materials Group, LLC published requirements,for tile
staging.
7. BUILDING PERMIT REQUIREMENTS: t°
As required by the Building Official orAuthorlty Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS: P
Gulfport,MS
9. QUALITY ASSURANCE ENTITY:
UL,LLC=QUA9625;(314)578-3406;k.chancellor@us.ul.com
-END OF EVALUATION REPORT-
Exterior Research and Design,LLC.. Evaluation Report A42960.10.12-R6
Cerrif Bate of Authori:atlon#9902 &EDITION 12017)FK 14ON-HVHZ EVALVAT fill FL16048 R6
7111-BUILT,Roof Underiayihents;,(800)516.1485 Revision 6:09/25/2017
Page 6 of 6
ftl ali
® Professional Regulafiow��jl
BCIS Home Log In I User Registration Hot Topics Submit Surcharge Stats&Facts l Publications I Contact Us I BCIS Site Map I Links I Search
a
1 " Product Approval
1 USER:Public User
dbpr t�!
.-I-Mlld
Product Approval Menu>Product or Application Search>Application List>Application Detail
• • FL# KL18355 R4
• Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived O
Product Manufacturer TAMKO Building Products, Inc.
Address/Phone/Email PO Box 1404
Joplin, MO 64802
(417) 624-6644 Ext 2305
kerri—eden@tamko.com
Authorized Signature Kerri Eden
kerri_eden@tamko.com
Technical Representative Kerri Eden
Address/Phone/Email PO Box 1404
Joplin, MO 64802
(417) 624-6644 Ext 2305
kerri_eden@tamko.com 0 C
n z
Quality Assurance Representative
N+ M
cc *—tI
Address/Phone/EmailG
NO 17
3 co I
Category Roofing T
Subcategory Asphalt Shingles to
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional
Engineer
Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed the Zachary R. Priest
Evaluation Report
Florida License PE-74021
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/18/2021
Validated By Locke Bowden P.E.
D✓ Validation Checklist- Hardcopy Received
Certificate of Independence FL18355 R4 COI TBP15001.4 2017 FBC Eval Report Shingles final.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D 3161 2016
ASTM D 3462 2010
ASTMD D 7158 2011
TAS 100 1995
Equivalence of Product Standards
Certified By Approved Testing Lab
FL18355 R4 Equiv UL letter for standards for FBC 2017.pdf
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 09/25/2017
Date Validated 09/27/2017
Date Pending FBC Approval 10/08/2017
Date Approved 12/12/2017
Summary of Products
.FL# Model, Number or Name Description
(18355.11 ;Glass-Seal, Elite Glass-Seal, Heritagel STM D 3462 asphalt shingles_and h_ip_and ridge shingles;
'Heritage Premium, Heritage Woodgate,)
(Heritage Vintage, Hip and Ridge,anJ
!Vintage Hip and Ridge Shingles
(Limits of Use Installation Instructions)
Approved for use in HVHZ:Ye_s;)` 'FL18355 R4 II TBP15001.4 2017 FBC Eval Report Shingles finaLpdfl
(Approved for use outside HVHZ: Yes (Verified By: Zachary R. Priest PE-74021
(Impact Resistant: N/A SCreated_by Independent Third Party. Yes
jDesign Pressure: N/A _ (Evaluation ReportsE��
(Other: See evaluation report for limits of use. (FL18355 R4 AE TBP15001.4 2017 FBC EvaI-Report Shingles final.pdf)
(Created by IndependeThird Party Yes!
— ---
nt -
Back Next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.:: Privacy tatement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,
contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees
licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email
addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a
licensee under Chapter 455,F.S.,please click here-.
Product Approval Accepts:
s � eCheck
Credit Card
Safe
Certificate of Authorization No.29824
A-M-M-0 G E E K 17520 Edinburgh Dr
Tampa, FL 33647
TECHNICAL SERVICES, LLC (813)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE,6T"EDITION(2017)
Manufacturer: TAMKO BUILDING PRODUCTS Issued September 25, 2097
220 West 0 Street
Joplin, MO 64801
(417)624-6644
Manufacturing Plants: Joplin, MO
Phillipsburg, KS
Frederick, MD
Dallas,TX
Tuscaloosa,AL
Quality Assurance: UL LLC(QUA9625)
SCOPE
Category: Roofing
Subcategory: Asphalt Shingles
Code Sections: 1504.1.1, 1507.2.5, 1507.2.7.1, 1523.6.5.1
Properties: Physical properties,Wind Resistance,Wind Driven Rain
REFERENCES
iniL Report No. Standard Year
PRI Construction Materials Technologies(TST5878) TAP-043-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-051-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-054-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-114-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-117-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-130-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-131-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-165-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-280-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-303-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-307-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-314-02-01 Rev 2 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-315-02-01 ASTM D 6381 2008(2013)e1
PRI Construction Materials Technologies(TST5878) TAP-317-02-01 TAS 100 1995
UL LLC(TST9628) 02NK9607 ASTM D 3161 2016
UL LLC(TST9628) 04NK24366 ASTM D 3462 2010A
UL LLC(TST9628) 06NK28006 ASTM D 6381 2008(2013)e1
UL 2390
ASTM D 7158 2011
UL LLC(TST9628) 06NK03898 ASTM D 3161 2016
ASTM D 3462 2010A
UL LLC(TST9628) 08CA59132 ASTM D 3161 2016
UL LLC(TST9628) 09NK07896 ASTM D 3161 2016
ASTM D 3462 2010A
UL LLC(TST9628) 1 OCA50498 ASTM D 3462 2010A
UL LLC(TST9628) 1 OCA64882 ASTM D 3161 2016
UL LLC(TST9628) 1INK14014 ASTM D 3161 2016
ASTM D 3462 2010A
UL LLC(TST9628) 12CA24551 ASTM D 3161 2016
UL LLC(TST9628) 4786110543 ASTM D 6381 2008(2013)e1
UL LLC(TST9628) 4787043752 ASTM D 3161 2016
UL LLC(TST9628) 4787148748 ASTM D 7158 2011
ASTM D 3161 2016
ASTM D 3462 2010A
CREEK Technical Services LLC(ANE11669) TBP15001.3 Calculations 2017
TBP15001.4 FL18355-R4 Page 1 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES,LLC
PRODUCT DESCRIPTION
Elite Glass-Seal® 12-1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab
(Frederick,Joplin& asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with
Tuscaloosa) ceramic granules complying with ASTM D 3462.
Glass-Seal 12-1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab
(Frederick& asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with
Tuscaloosa) ceramic granules complying with ASTM D 3462.
Glass-Seal 12-1/4"x 36", ASTM D 7158, Class H self-sealing, 3-tab asphalt shingle with fiberglass
(Joplin) mat coated on both sides with asphalt and surfaced with ceramic granules complying
with ASTM D 3462. Shingles shall be used in the non-HVHZ only.
Heritage® 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas,Frederick, reinforced, laminated architectural asphalt shingle surfaced with mineral granules
Joplin,Phillipsburg& complying with ASTM D 3462.
Tuscaloosa)
Heritage®Premium 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas,Frederick, reinforced, laminated architectural asphalt shingle surfaced with mineral granules
Phillipsburg& complying with ASTM D 3462.
Tuscaloosa)
Heritage®Premium 12" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced,
(Frederick) laminated architectural asphalt shingle surfaced with mineral granules complying with
ASTM D 3462.
Heritage®Vintage® 17-1/2"x 40",ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced,
(Phillipsburg) laminated architectural asphalt shingle surfaced with mineral granules complying with
ASTM D 3462.
Heritage@Woodgate 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas&Frederick) reinforced, laminated architectural asphalt shingle surfaced with mineral granules
complying with ASTM D 3462.
Heritage®Woodgate 12° x 36-3/8", ASTM D 3161, Class F fiberglass reinforced, laminated architectural
(Frederick) asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Shingles
shall be used in the non-HVHZ only.
Hip and Ridge Shingles 12-1/4" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt
(Frederick&Joplin) shingle surfaced with mineral granules complying with ASTM D 3462.
Vintage®Hip and Ridge 12" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt shingle
(Phillipsburg) surfaced with mineral granules complying with ASTM D 3462.
TBP15001.4 FL18355-R4 Page 2 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES,LLC
INSTALLATION
Elite Glass-Seal® Basic Wind Speed(Vuic): Max. 194 mph
(Frederick, Joplin& Basic Wind Speed(Vasd): Max. 150 mph
Tuscaloosa) Deck(HVHZ): In accordance with FBC requirements;
& Solidly sheathed min. 19/32 in. plywood or wood plank for
Glass-Seal new construction; Min. 15/32 in. plywood existing
(Frederick, Joplin(Non- construction.
HVHZ)&Tuscaloosa) Deck(Non-HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min.7/16 in. OSB existing construction.
Underlayment: In accordance with FBC requirements.
Min.slope: 2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installation(HVHZ): Installed with 5-1/8 inch exposure in accordance with RAS
115 and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installation (Non-HVHZ): Installed with 5-1/8-inch exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either"4 Nail
Pattern"or"6 Nail Pattern"detailed below.
NAILS
Nailing - ----------------------------------------------------- ------- 6-718"
Alm -----------------.-------------- ----------------------------7---------------------
-1/8"
Butt Edge
Figure 1. Elite Glass-Seal&Glass-Seal
4 Nail Pattern (Non-HVHZ only)
NAILS
Nailing --- -------------
.--------------------- ----------------------- -------- ---- 6-7/811
-----------------
Area - - _ — - -------------------- ......--...............--
Bust Edge
Figure 2. Elite Glass-Seal&Glass-Seal
6 Nail Pattern
TBP15001.4 FL18355-R4 Page 3 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
GREEK TANIKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES,LLC
Heritage® Basic Wind Speed(V„it): Max:194 mph
(Dallas, Frederick,Joplin, Basic Wind Speed(Vasd): Max. 150 mph
Phillipsburg&Tuscaloosa) Deck(HVHZ): In accordance with FBC requirements;
& Solidly sheathed min. 19/32 in. plywood or wood plank for
Heritage®Premium new construction; Min. 15/32 in. plywood existing
(Dallas, Frederick construction.
Phillipsburg&Tuscaloosa) .Deck(Non-HVHZ): In accordance with.FBC requirements;
& Solidly sheathed min. 15/32 in. plywood or wood plank for
Heritage®Woodgate new construction; Min.7/16 in.OSB existing construction.
(Dallas&Frederick) Underlayment: In accordance with FBC requirements.
Min.slope: 2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installation(HVHZ): Installed with 5-5/8 in. exposure in accordance with RAS
115 and manufacturer's published installation instructions.
Shingles shall be attached using T Nail Pattern" detailed
below.
Installation (Non-HVHZ): Installed with 5-5/8 in. exposure in accordance with FBC
requirements and manufacturer's- published installation
instructions. Shingles shall be.attached using either"4 Nail
Pattern"or T Nail Pattern"detailed below.
FASTENERS NAIL ZON E
COMMON
BOND
6-118" EXPOSURES-6/8"
12-112" 12-318" - 12-112"--►I �--1"
Figure I Heritage®, Heritage®Premium,and Heritage®Woodgate(Dallas)
4 Nail Pattern.(non-HVHZ only)
FASTENERS NAIL ZONE
/COMMON
BOND
7-1 0
6-118" EXPOSURE 5-518"
1=--►I h-1-112"�-7-112"-�i-7-?118"-�1-7-1 f2"�-7-112"-►I h--1"
Figure 4. Heritage®&HeritageO Premium
6 Nail Pattern
TBP15001.4 FL18355-R4 Page 4 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not
specifically addressed herein.
r
GREEK TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES,LLC
NAIL ZONE/
ASTENERS COMMON 80ND
111111
.6-118" EXF03URE,5;518"•
'1:"' ` �,7-112=�-7-1/2'�►�-7�78'�►��7=1/27_-112 .IF-1",
Figure 5. Heritage®Woodgate
6 Nail Pattern
►I1°i1i< '1'2- /2°--%i i�--12-11i0c ir;14-
® Common,Bond
FASTENERS
A. i
�m t
U-1 1
_ 39-3/8"
Figure 6. Heritage®, Heritage®Premium, &Heritage®Woodgate
Alternate 6 Nail Pattern
PAINT"
LINE: _.
-
,-NAILGE ZONE':
18"
fi 1EDO.`Fr
r GOMM,
EXP:O'SURE:
AGGEPT�tiBLE . .:
' FASTENER LOCATION,
DO NOT:`:FAST
EN`,
ALONG EDGE''
_ = G.OMM:ON BONDc
.,.:--;PR FERRED
_FASTENER.0
:�LO,CATION
Figure 7. Heritage®(Tuscaloosa)
Expanded Nail Zone
Nail patterns from Figures 3,4,and 6 may be placed in the nail zone as described above
TBP15001.4 FL18355-R4 Page 5 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
r `
CREAK TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL,SERVICES,LLC
Heritage®Premium Basic Wind Speed(V„it): Max. 194 mph
(Frederick) Basic Wind Speed(Vasd): Max. 150 mph
Deck(HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
Deck(Non-HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min.7/16 in.OSB existing construction.
Underlayment: In accordance with FBC_requirements.
Min.slope: 2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12. .
Installation(HVHZ): Installed with 5 in. exposure in accordance with RAS 115
and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either°4 Nail
Pattern"or"6 Nail Pattern"detailed below.
NAIL ZONE/
FASTENERS COMMON BOND
551/2" EXPOSURE 511
1"--►I �— 11"--►�^ 12" ,►�-1111
Figure 8. Heritage®Premium(Frederick)
4 Nail Pattern (non-HVHZ only)
NAIL ZONE/
FASTENERS COMMON BOND
51/2" EXPOSURE 5"
1 n� ��1�n � �"�n �1/2n � I♦,1 n
Figure 9. Heritage®Premium (Frederick)
6 Nail Pattern
TBP15001.4 FL18355-R4 Page 6 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREAK TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES,LLC
Heritage®Woodgate Basic Wind Speed(Vit): Max. 194 mph
(Frederick) Basic Wind Speed(Vasa): Max. 150 mph
Deck(Non-HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min.7/16 in. OSB existing construction.
Underlayment: In accordance with FBC requirements.
Min.slope: 2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either"4 Nail
Pattern"or"6 Nail Pattern"detailed below.
NAIL ZONE/
FASTENERS X; COMMON BOND
5-1/2" EXPOSURE Y
I
d
1r",4 11 r' - -'12-318"
Figure 10: Heritage®Woodgate(Frederick)
4 Nail Pattern (non-HVHZ only)
NAIL ZON V
COMMON BOND
FASTENERS
5.112" EXPOSURE 5"
Figure 11. Heritage®Woodgate(Frederick)
6 Nail Pattern
TBP15001.4 FL18355-R4 Page 7 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not
specifically addressed herein.
r
CREEK TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES,LLC
Heritage®Vintage® Basic Wind Speed(V„it): Max. 194 mph
(Phillipsburg) Basic Wind Speed(V,sd): Max. 150 mph
Deck(HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
Deck(Non-HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min.7/16 in.OSB existing construction.
Underlayment: In accordance with FBC requirements.
Min. slope: 2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installation(HVHZ): Installed with 5 in. exposure in accordance with RAS 115
and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either"5 Nail
Pattern"or"6 Nail Pattern"detailed below.
4W
ugmnt Exposure
Notch
6„ Fasteners Nail
or'
e
- - - - - - - - - - - i - - - -
s^
Exposure
}
IAC 47M' 9-VS—�-9-tM'
Figure 12. Heritage®Vintage®
5 Nail Pattern (non-HVHZ only)
ap=m
rl
otch
MtMt
FasmmR NON
- - - 011C
f2`
r
Bgosum
} 7,Yr- 7-,'ilY'
Figure 13. Heritage®Vintage°
6 Nail Pattern
TBP15001.4 FI-18355-R4 Page 8 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not
specifically addressed herein.
GREEK TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICEs,LLC
Hip&Ridge Basic Wind Speed(Vuic): Max. 194 mph
(Frederick&Joplin) Basic Wind Speed(Vasd): Max. 150 mph
Deck(HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
Deck(Non-HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min.7/16 in. OSB existing construction.
Underlayment: In accordance with FBC requirements.
Min.slope: 2:12 and in accordance with FBC requirements.
Installation: Installed with 5-1/8 inch exposure in accordance with the
FBC and manufacturer's published installation instructions.
The direction of the exposed end shall be away from the
prevailing wind.
Direction of prevailing wind
Start h5-1/8" exposure
ere—
i II
Start
Figure 1 here 5-1/8"exposure
log
Fastener C� Fastener
Figure 2 1'4 Figure 3
„
Figure 14. Hip &Ridge(Frederick&Joplin)
TBP15001.4 FL18355-R4 Page 9 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES,LLC
Vintage®Hip&Ridge Basic Wind Speed(Vui,): Max. 194 mph
(Phillipsburg) Basic Wind Speed(V,,d): Max. 150 mph
Deck(HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
Deck(Non-HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min.7/16 in. OSB existing construction.
Underlayment: In accordance with FBC requirements.
Min.slope: 2:12 and in accordance with FBC requirements.
Installation: Installed with 5 inch exposure in accordance with the FBC
and manufacturer's published installation instructions. The
direction of the exposed end shall be away from the
prevailing wind.
Direction of prevailing wind
hret 5 �" exposure
111
Start
here 511 exposure
Figure 1
' 1"
Fastener - Fastener
�5-1/2" -1/211
Figure
Figure 2 1 4 Figure 3
Figure 15. Vintage®Hip&Ridge(Phillipsburg)
TBP15001.4 FL18355-R4 Page 10 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
a
GREEK TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES,LLC
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads
established for components and cladding and in accordance with FBC requirements.
3) The mean roof height shall be restricted to a maximum 33 ft in the HVHZ.
4) Classification to ASTM D 7158 applies to exposure B&C with a building mean roof height of 60-ft or less.
5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion and corrected prior to underlayment application.
6) Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the
deck.
7) Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer's
published application instructions. Where discrepancies exist between these sources, the more restrictive
and code compliant detail shall prevail.
8) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code,6t'Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer.
00111111111111,
R.
,,,�G�PFtY
_._....w2017.09.25
No 74021 11 :31 :41
� 1 = �MW.MLrdry0.RwC
-04'00'
:33'. STATE O F :1JJ
��T••.'°� O P•.-4;t- Zachary R. Priest, P.E.
0
,�'�i,S�O►�g1.� Florida`,` O gani ation No.Ion No. 1
ANE11669
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E.does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
TBP15001.4 FL18355-R4 Page 11 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.