HomeMy WebLinkAboutProduct Approval Florida Building Cade Online Page 1 of 3
®R tom.
BCIS Home { Log In User Registration j Hot Topics Submit Surcharge Stats&Facts i Publications Contact Us I BOSS Site Map Unks Search
Two
Product Approval
USER:Public User
Product Aooroval Menu>Product or Application Search>AmAjotion.List>Application Detail
FL# FL9190-R7
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived 01
Product Manufacturer LP Building Products
Address/Phone/Email 414 Union Street-Bank of America Plaza
Suite 2000
Nashville,TN 37219
(352)425-7457
cw.macomber@lpcorp.com
Authorized Signature CW Macomber
cw.macomber@lpcorp.com
Technical Representative CW Macomber
Address/Phone/Email 5712 SW 40th Place
Ocalo,FL 34474
(352)425-7457
cw.macomber@lpcorp.com
Quality Assurance Representative CW Macomber
Address/Phone/Emaif 5712 SW 40th Place
Ocala,FL 34474
(352)425-7457
cw.macomber@lpcorp.com
Category Panel Walls
Subcategory Siding
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
0 Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Do Kim,P.E.
the Evaluation Report
Florida License PE-49497
Quality Assurance Entity APA-The Engineered Wood Association
Quality Assurance Contract Expiration Date 12/31/2022
Validated By James L.Buckner,P.E.@ CBUCK Engineering
.till Validation Checklist-Hardcopy Received
Certificate of Independence FL9190 R7 COI LP Certlficatg of Independence.odf
Referenced Standard and Year(of Standard)
Equivalence of Product Standards
Certified By Florida Licensed Professional Engineer or Architect
FL9190 R7 Eguiv equivalency of standard form.odf
Sections from the Code
1405
1604.3.1
1609.1
https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDquJPW%2b4Ut... 6/12/2019
Florida Building Code Online Page 2 of 3
1616.3.1
1626.1
2304.6
Product Approval Method Method 2 Option B
Date Submitted 12/17/2018
Date Validated 12/17/2018
Date Pending FBC Approval 12/25/2018
Date Approved 02/19/2019
gurnmary of Products
FL# Model,Number or Name Description
9190.1 LP SmartSide 38 Series Strand Vertical siding for board&batten applications.
Substrate Vertical Siding
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL9190 R7 II Strand Substrate Siding Fastener Tables
Approved for use outside HVHZ:Yes R7.odf
Impact Resistant:No FL9190 R7 II TN 028 Vertical Siding 12-22-16-Strand.pdf
Design Pressure:N/A Verified By:APA-The Engineered Wood Association
Other:Refer to Evaluation Report.Product is not impact Created by Independent Third Party:Yes
resistant.In HVHZ,must be used in conjunction with Evaluation Reports
approved impact resistant product except for uninhabitable FI 9190 R7--AF_Fvahiatinn Renort of I.P Sidino 9190-R7.
structures such as sheds. 20i7-pg
Created by Independent Third Party:Yes
9190.2 LP SmartSide Cedar Shake Lap Architectural Collection Cedar Shake 76 Series Lap Siding
Siding
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes
Approved for use outside HVHZ:Yes FL9190 R7 II LPZB0507-Cedar Shakes-Lao.pdF
Impact Resistant:No Verified By:APA-The Engineered Wood Association
Design Pressure:N/A Created by Independent Third Party:Yes
Other:Refer to Evaluation Report.Product is not impact Evaluation Reports
resistant.In HVHZ,must be used in conjunction with FL9190 R7 AE Evaluation Report of LP Siding 9190-117-
approved impact resistant product except for uninhabitable 2017.pdf
structures such as sheds. Created by Independent Third Party:Yes
9190.3 LP SmartSide Fiber Substrate Bold Architectural Collection Primed Bold Profile 120 Series Lap
Profile Lap Siding Siding(D5,T4,D8,TS,Q4)
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL9190 R7 II Fiber Substrate Siding Fastener Tables.pdf
Approved for use outside HVHZ:Yes FI ai Vin, R7.11 I P7R(15Q4-Arfhitartiira_I(nIIPrYinn=Rnld
Impact Resistant:No Profile-Lap.Pdf
Design Pressure:N/A Verified By:APA-The Engineered Wood Association
Other:Refer to Evaluation Report.Product is not impact Created by Independent Third Party:Yes
resistant.In HVHZ,must be used in conjunction with Evaluation Reports
approved impact resistant product except for uninhabitable FI-9190 R7 AE Evaluation Report of LP Siding 9190-R7-
structures such as sheds. 2 17, df
Created by Independent Third Party:Yes
9190.4 LP SmartSide Fiber Substrate Lap Foundations 76 Series Primed Lap Siding.Architectural
and Panel Siding Collection 76 Series Primed Colonial and 120 Series Primed
Self-aligning Lap Siding.
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL9190 R7 II Fiber Substrate Siding Fastener Tables.pdf
Approved for use outside HVHZ:Yes77 7:7
_ '_ r
Impact Resistant:No Collection-Lap.odf
Design Pressure:N/A FL9190 R7 II LPZBO511-Foundations and Architectural
Other:Refer to Evaluation Report for Panel Siding over SIP Collection-Panel.pdf
installation detail.Product is not impact resistant.In HVHZ, Verified By:APA-The Engineered Wood Association
must be used in conjunction with approved impact resistant Created by Independent Third Party:Yes
product except for uninhabitable structures such as sheds. Evaluation Reports
FI aian R7 AF Pcnnrt of I P Siriinn Q7a(,-R7-
2017.pdf
Created by Independent Third Party:Yes
9190.5 LP SmartSide Perfection Shingle Fiber substrate lap siding.
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL9190 R7 II Fiber Substrate Siding Fastener Tables.pdf
Approved for use outside HVHZ:Yes FL3i i6 R7 Ii LF SS Peileciian SiuuGic -
Impact Resistant:No 17 FINAL.odf
Design Pressure:N/A Verified By:APA-The Engineered Wood Association
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquJPW%2b4Ut... 6/12/2019
Florida Building Code Online Page 3 of 3
Other:Refer to Evaluation Report.Product is not impact Created by Independent Third Party:Yes
resistant.In HVHZ,must be used in conjunction with Evaluation Reports
approved impact resistant product except for uninhabitable FL9190 R7 AE Evaluation Reoort of LP Siding 9190-R7-
structures such as sheds. 2017.Ddf
Created by Independent Third Party:Yes
9190.6 LP SmartSide Strand Substrate Lap Precision Series 38 and 76 Series Primed Lap Siding.
and Panel Siding Precision 38,76,190 Series Primed Panel Siding including
Silvertech&Smartfinish.
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL919C1__R7_II_LPZB0512,-_Precisipn_Series-Panel.odf
Approved for use outside HVHZ:Yes FL9i90 R7 1I LPZ60515-Precision Series-Lao.Ddr
Impact Resistant:No FL9190 R7 II Strand Substrate Siding Fastener Tables
Design Pressure:N/A R7.Ddf
Other:Refer to Evaluation Report for Panel Siding over SIP Verified By:APA-The Engineered Wood Association
installation detail.Product is not impact resistant.In HVHZ, Created by Independent Third Party:Yes
must be used in conjunction with approved impact resistant Evaluation Reports
product except for uninhabitable structures such as sheds. FL9190 R7 AE Evaluation Report of LP Siding 9190-117-
20�,,Duf
Created by Independent Third Party:Yes
Back Next
Contact Us::2601 Blair Stone Road Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275
(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The
emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please
click here.
Product Approval Accepts:
. eGlircl: M
® Safe
https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDquJPW%2b4Ut... 6/12/2019
e ■
G•
SMARTSIOE" PRECISION 38,76 AND 190 SERIES
PRIMED PANEL SIDING
BUILDING pR000[T5 TRiM&SIDING INCLUDING SILVERTECH&SMARTFINISH
100 IN 01111116"
• At the time of manufacture,siding meets or exceeds the per- Moisture control and water vapor control are critical elements
formance standards set forth in ICC-ES-AC321 and has achieved of proper housing design.Check your local building codes for
code recognition under ESR-1301,CCNC 11826,APA recognition application procedures for handling moisture and water vapor
under PR-N124,and HUD recognition under HUD-MR-1318.For in your area.
copies of E5R-1301,call LP£ustomer Support at 1-Sett-648-5893
or go online at http://www.ice-es.org/reports/pdf_files/ICC-ES/ When using wet blown cellulose insulation,the insulation
ESR-1301.pdf or http://www.apawood.org. must not be in direct contact with the siding and it must be
allowed to dry a minimum of 24 hours or longer if specified by
• Precision Series panel siding with SILVERTECH or SMARTFINISH the insulation manufacturer.
is specifically for sheds and other outdoor structures where the
interior wall cavities will remain permanently exposed. As with all wood products,do not apply engineered wood
siding to a structure having excessive moisture conditions such
• Minimum 6 in,clearance must be maintained between siding as drying concrete,plaster or wet blown cellulose insulation.If
and finish grade. such conditions exist,the building should be well ventilated to
allow it to dry prior to the application of the siding.
• Siding applied adjacent to porches,patios,walks,etc.must have
a clearance of at least 1 in.mm above any surface.
. Siding must not be applied to green or crooked structural
framing members.Do not apply siding over rain-soaked or
• Minimum 1 in.clearance at intersection with roof line buckled sheathing materials.
• Apply siding in a manner that prevents moisture intrusion and • Gutters are recommended for control of roof water run off.
watertruitdup.
• Ail exposed wood substrate must be sealed in a manner that -- - '—
prevents moisture intrusion and water buildup. • A properly installed breathable water-resistive barrier is
required behind the siding.Consult your local building code for
= LPA does not recommend LP SmartS dePanetfcrr usefntCF and det-ails-
SIP assemblies.If used,LP will not warrant for Buckling and
Shrinkage.However,balance of warranty does remain intact. • LP will assume no responsibility for water penetration.
• DO NOT USE STAPLES • Precision Series panel siding with SILVERTECH or
SMARTFINISH does not require a secondary water-resistant
SIDING MUST NOT BE IN DIRECT CONTACT WITH MASONRY, barrier.Limited to sheds and other outdoor structures.
CONCRETE,BRICK,STONE,STUCCO OR MORTAR.
• Seal all gaps with a high-quality,non-hardening,paintable
• Store off thepported,on a fiat surface,under a round well supported, sealant.Follow the sealant manufacturer's instructions for
g
roof or separate waterproof covering application.
. Keep siding clean and dry.inspect prior to application. Use a high-quality exterior sealant meeting the ASTM C920,
minimum Class 25 sealant.
• Precision 38 and 76 Series panel siding must be installed on
1661n.fi.£,framing only.When install#ng on 24 in.D.C.framing, All openings must be properly sealed or flashed in a manner
Precision Series 190 Series panel siding is required, that prevents moisture intrusion or buildup. Several examples
that accomplish this are shown on the following pages.
• In all installations over masonry or concrete walls,the wall shall
be furred out and open at the top and bottom of the wall to allow
for convective ventilation between framing spaced 16 in.O.C. The
framing shall be of adequate thickness to accept 1-1/2 inches of nail
penetration. A properly installed breathable water-resistant barrier
is required between the siding and masonry or concrete walls.
y�
" Scant face width
HORIZONTAL BELTLINE JOINTS Figure9 M
For multi-story buildings,make provisions at horizontal joints for
"setting"shrinkage of framing,especially when applying sidingR,x.
directly to studs. = {
Siding.(4 ft.x 8 ft.) " ._ w
{ 3/8 in.gap 1/8 in.gap
r zi' Sloped flashing with
4 in.vertical leg SPACE JOINT 1/8 IN.
BAND BOARD OVER t
PANEL FILLER 1. 2 in.x 10 in. Refer to nailing instructions
band board 1I8 m.gap
7 Filler Board
�-- Siding(4 ft.x 8 ft.)
LP panel sidings are accepted by the State of California as category
8140-Exteriorwall siding and sheathing for Wildland Urban Interface
Figure 6 (WUI)applications. For WUI compliance,install LP panel sidings in
accordance with Louisiana-Pacific's printed installation instructions
with the addition of fire retardant seal(UL Listed fire caulk,nominal
� . 1/4"bead)in the vertical joint and nailing pattern of 3"OC perimeter
�A444.�'6:Q6 Na D"C'aa1�.a4af t.'C-' 6;,14-1 Jl�� nim
nailing/8'
1
OC field nailing: Look for the California State Fire Marshal
Office label on our siding.
The Louisiana-Pacific Corporation("LP")LP SmartSide Siding(the
OR "Products")limited warranty(the"Warranty")applies only to
Sip plate structures on which the Products have been applied,finished and
Sill plate maintained in accordance with the published application,finishing
Extend j and maintenance instructions in effect at the time of application.
sidinelow ( The failure to follow such application,finishing or maintenance
Sill late {{(}( Flashing instructions will void the Warranty as to the portion of the Products
P lil 7 -77 7,. r h:
x� n
affected by the variance(the"Affected Products").
Min.1/8 in.or
tri LP assumes no liability for any loss or damage sustained by the
flashing between
siding and Masonr
Affected Products and is expressly released by the purchaser or owner
h _ y F
masonry. foundation " from any such loss or liability.
Any modification of the Warranty's application,finishing or
Figure iA Figure its maintenance requirements is void and unenforceable unless approved
in writing prior to application by the Siding General Manager or his
designee and a member of the LP Legal Department.
For a copy of the warranty or for installation and technical support,visit the
LP SmartSide product support Web site at:
Interior Finish Siding www.lpsmartside.com
Code Approved Breathable or for additional support call 800-450-6106.
t Water-Resistive Barrier
i 3/8 in gap WARRANTY REMEDIES ARE NOT AVAILABLE IF
Sloped flashing with REQUIREMENTS ARE NOT FOLLOWED.
----" 4 in.vertical leg
Trim Cal.Prop 65 Warning:Use of this product may result in
h`
Nail fin exposure to wood dust,known to the State of California
Space window)door per (do not damage) to cause canter.
manufacturer's instruction
Figure 8 SMARTS 1 D E
TRIM 6 SIDING
BUILDING PRODUCTS
02014 Louisiana-Pacific Corporation.All rights reserved.LP,SmartSide,SilverTech and SmartFinish
are registered trademarks of Louisiana-Pacific Corporation.Printed in U.S.A.
NOTE:Louisiana-Padfic Corporation periodically updates and revises its product Information.
To verify that this version Is current,call 800-450-6106.
LPZ80512 1114
alternate inside corner details
Gap 3/16 in.
Gap 3/16 in:and seal and seal
} ! t1 caulk y �i
111 f
4f
figure.20A Figure 30B
Figure 10
Vapor Retarder
-` if required
by code
bio II Breathable
water-resistant
barrier
yam,
6 In
i a . .
�- .� <�'�, �i%tom^ i./j•a't
• y y .y
i . 1
JN� YY Yl
{/jam-�T,317 1 �Vf � •,-i. I
:Z:
VLv
-` �, '. .'T :••��rj'Y it y I ii�.�:,'
t��•�^.r � e.; t •rte 6 in mm=mum '
S'•r �. i.i 9�• f f r VV.'
ground clearance
paint
figure 10C
bottom course detail panel joint
Figure 10E Figure 100