Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Cade Online Page 1 of 3 ®R tom. BCIS Home { Log In User Registration j Hot Topics Submit Surcharge Stats&Facts i Publications Contact Us I BOSS Site Map Unks Search Two Product Approval USER:Public User Product Aooroval Menu>Product or Application Search>AmAjotion.List>Application Detail FL# FL9190-R7 Application Type Revision Code Version 2017 Application Status Approved Comments Archived 01 Product Manufacturer LP Building Products Address/Phone/Email 414 Union Street-Bank of America Plaza Suite 2000 Nashville,TN 37219 (352)425-7457 cw.macomber@lpcorp.com Authorized Signature CW Macomber cw.macomber@lpcorp.com Technical Representative CW Macomber Address/Phone/Email 5712 SW 40th Place Ocalo,FL 34474 (352)425-7457 cw.macomber@lpcorp.com Quality Assurance Representative CW Macomber Address/Phone/Emaif 5712 SW 40th Place Ocala,FL 34474 (352)425-7457 cw.macomber@lpcorp.com Category Panel Walls Subcategory Siding Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 0 Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Do Kim,P.E. the Evaluation Report Florida License PE-49497 Quality Assurance Entity APA-The Engineered Wood Association Quality Assurance Contract Expiration Date 12/31/2022 Validated By James L.Buckner,P.E.@ CBUCK Engineering .till Validation Checklist-Hardcopy Received Certificate of Independence FL9190 R7 COI LP Certlficatg of Independence.odf Referenced Standard and Year(of Standard) Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL9190 R7 Eguiv equivalency of standard form.odf Sections from the Code 1405 1604.3.1 1609.1 https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDquJPW%2b4Ut... 6/12/2019 Florida Building Code Online Page 2 of 3 1616.3.1 1626.1 2304.6 Product Approval Method Method 2 Option B Date Submitted 12/17/2018 Date Validated 12/17/2018 Date Pending FBC Approval 12/25/2018 Date Approved 02/19/2019 gurnmary of Products FL# Model,Number or Name Description 9190.1 LP SmartSide 38 Series Strand Vertical siding for board&batten applications. Substrate Vertical Siding Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL9190 R7 II Strand Substrate Siding Fastener Tables Approved for use outside HVHZ:Yes R7.odf Impact Resistant:No FL9190 R7 II TN 028 Vertical Siding 12-22-16-Strand.pdf Design Pressure:N/A Verified By:APA-The Engineered Wood Association Other:Refer to Evaluation Report.Product is not impact Created by Independent Third Party:Yes resistant.In HVHZ,must be used in conjunction with Evaluation Reports approved impact resistant product except for uninhabitable FI 9190 R7--AF_Fvahiatinn Renort of I.P Sidino 9190-R7. structures such as sheds. 20i7-pg Created by Independent Third Party:Yes 9190.2 LP SmartSide Cedar Shake Lap Architectural Collection Cedar Shake 76 Series Lap Siding Siding Limits of Use Installation Instructions Approved for use in HVHZ:Yes Approved for use outside HVHZ:Yes FL9190 R7 II LPZB0507-Cedar Shakes-Lao.pdF Impact Resistant:No Verified By:APA-The Engineered Wood Association Design Pressure:N/A Created by Independent Third Party:Yes Other:Refer to Evaluation Report.Product is not impact Evaluation Reports resistant.In HVHZ,must be used in conjunction with FL9190 R7 AE Evaluation Report of LP Siding 9190-117- approved impact resistant product except for uninhabitable 2017.pdf structures such as sheds. Created by Independent Third Party:Yes 9190.3 LP SmartSide Fiber Substrate Bold Architectural Collection Primed Bold Profile 120 Series Lap Profile Lap Siding Siding(D5,T4,D8,TS,Q4) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL9190 R7 II Fiber Substrate Siding Fastener Tables.pdf Approved for use outside HVHZ:Yes FI ai Vin, R7.11 I P7R(15Q4-Arfhitartiira_I(nIIPrYinn=Rnld Impact Resistant:No Profile-Lap.Pdf Design Pressure:N/A Verified By:APA-The Engineered Wood Association Other:Refer to Evaluation Report.Product is not impact Created by Independent Third Party:Yes resistant.In HVHZ,must be used in conjunction with Evaluation Reports approved impact resistant product except for uninhabitable FI-9190 R7 AE Evaluation Report of LP Siding 9190-R7- structures such as sheds. 2 17, df Created by Independent Third Party:Yes 9190.4 LP SmartSide Fiber Substrate Lap Foundations 76 Series Primed Lap Siding.Architectural and Panel Siding Collection 76 Series Primed Colonial and 120 Series Primed Self-aligning Lap Siding. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL9190 R7 II Fiber Substrate Siding Fastener Tables.pdf Approved for use outside HVHZ:Yes77 7:7 _ '_ r Impact Resistant:No Collection-Lap.odf Design Pressure:N/A FL9190 R7 II LPZBO511-Foundations and Architectural Other:Refer to Evaluation Report for Panel Siding over SIP Collection-Panel.pdf installation detail.Product is not impact resistant.In HVHZ, Verified By:APA-The Engineered Wood Association must be used in conjunction with approved impact resistant Created by Independent Third Party:Yes product except for uninhabitable structures such as sheds. Evaluation Reports FI aian R7 AF Pcnnrt of I P Siriinn Q7a(,-R7- 2017.pdf Created by Independent Third Party:Yes 9190.5 LP SmartSide Perfection Shingle Fiber substrate lap siding. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL9190 R7 II Fiber Substrate Siding Fastener Tables.pdf Approved for use outside HVHZ:Yes FL3i i6 R7 Ii LF SS Peileciian SiuuGic - Impact Resistant:No 17 FINAL.odf Design Pressure:N/A Verified By:APA-The Engineered Wood Association https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquJPW%2b4Ut... 6/12/2019 Florida Building Code Online Page 3 of 3 Other:Refer to Evaluation Report.Product is not impact Created by Independent Third Party:Yes resistant.In HVHZ,must be used in conjunction with Evaluation Reports approved impact resistant product except for uninhabitable FL9190 R7 AE Evaluation Reoort of LP Siding 9190-R7- structures such as sheds. 2017.Ddf Created by Independent Third Party:Yes 9190.6 LP SmartSide Strand Substrate Lap Precision Series 38 and 76 Series Primed Lap Siding. and Panel Siding Precision 38,76,190 Series Primed Panel Siding including Silvertech&Smartfinish. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL919C1__R7_II_LPZB0512,-_Precisipn_Series-Panel.odf Approved for use outside HVHZ:Yes FL9i90 R7 1I LPZ60515-Precision Series-Lao.Ddr Impact Resistant:No FL9190 R7 II Strand Substrate Siding Fastener Tables Design Pressure:N/A R7.Ddf Other:Refer to Evaluation Report for Panel Siding over SIP Verified By:APA-The Engineered Wood Association installation detail.Product is not impact resistant.In HVHZ, Created by Independent Third Party:Yes must be used in conjunction with approved impact resistant Evaluation Reports product except for uninhabitable structures such as sheds. FL9190 R7 AE Evaluation Report of LP Siding 9190-117- 20�,,Duf Created by Independent Third Party:Yes Back Next Contact Us::2601 Blair Stone Road Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: . eGlircl: M ® Safe https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDquJPW%2b4Ut... 6/12/2019 e ■ G• SMARTSIOE" PRECISION 38,76 AND 190 SERIES PRIMED PANEL SIDING BUILDING pR000[T5 TRiM&SIDING INCLUDING SILVERTECH&SMARTFINISH 100 IN 01111116" • At the time of manufacture,siding meets or exceeds the per- Moisture control and water vapor control are critical elements formance standards set forth in ICC-ES-AC321 and has achieved of proper housing design.Check your local building codes for code recognition under ESR-1301,CCNC 11826,APA recognition application procedures for handling moisture and water vapor under PR-N124,and HUD recognition under HUD-MR-1318.For in your area. copies of E5R-1301,call LP£ustomer Support at 1-Sett-648-5893 or go online at http://www.ice-es.org/reports/pdf_files/ICC-ES/ When using wet blown cellulose insulation,the insulation ESR-1301.pdf or http://www.apawood.org. must not be in direct contact with the siding and it must be allowed to dry a minimum of 24 hours or longer if specified by • Precision Series panel siding with SILVERTECH or SMARTFINISH the insulation manufacturer. is specifically for sheds and other outdoor structures where the interior wall cavities will remain permanently exposed. As with all wood products,do not apply engineered wood siding to a structure having excessive moisture conditions such • Minimum 6 in,clearance must be maintained between siding as drying concrete,plaster or wet blown cellulose insulation.If and finish grade. such conditions exist,the building should be well ventilated to allow it to dry prior to the application of the siding. • Siding applied adjacent to porches,patios,walks,etc.must have a clearance of at least 1 in.mm above any surface. . Siding must not be applied to green or crooked structural framing members.Do not apply siding over rain-soaked or • Minimum 1 in.clearance at intersection with roof line buckled sheathing materials. • Apply siding in a manner that prevents moisture intrusion and • Gutters are recommended for control of roof water run off. watertruitdup. • Ail exposed wood substrate must be sealed in a manner that -- - '— prevents moisture intrusion and water buildup. • A properly installed breathable water-resistive barrier is required behind the siding.Consult your local building code for = LPA does not recommend LP SmartS dePanetfcrr usefntCF and det-ails- SIP assemblies.If used,LP will not warrant for Buckling and Shrinkage.However,balance of warranty does remain intact. • LP will assume no responsibility for water penetration. • DO NOT USE STAPLES • Precision Series panel siding with SILVERTECH or SMARTFINISH does not require a secondary water-resistant SIDING MUST NOT BE IN DIRECT CONTACT WITH MASONRY, barrier.Limited to sheds and other outdoor structures. CONCRETE,BRICK,STONE,STUCCO OR MORTAR. • Seal all gaps with a high-quality,non-hardening,paintable • Store off thepported,on a fiat surface,under a round well supported, sealant.Follow the sealant manufacturer's instructions for g roof or separate waterproof covering application. . Keep siding clean and dry.inspect prior to application. Use a high-quality exterior sealant meeting the ASTM C920, minimum Class 25 sealant. • Precision 38 and 76 Series panel siding must be installed on 1661n.fi.£,framing only.When install#ng on 24 in.D.C.framing, All openings must be properly sealed or flashed in a manner Precision Series 190 Series panel siding is required, that prevents moisture intrusion or buildup. Several examples that accomplish this are shown on the following pages. • In all installations over masonry or concrete walls,the wall shall be furred out and open at the top and bottom of the wall to allow for convective ventilation between framing spaced 16 in.O.C. The framing shall be of adequate thickness to accept 1-1/2 inches of nail penetration. A properly installed breathable water-resistant barrier is required between the siding and masonry or concrete walls. y� " Scant face width HORIZONTAL BELTLINE JOINTS Figure9 M For multi-story buildings,make provisions at horizontal joints for "setting"shrinkage of framing,especially when applying sidingR,x. directly to studs. = { Siding.(4 ft.x 8 ft.) " ._ w { 3/8 in.gap 1/8 in.gap r zi' Sloped flashing with 4 in.vertical leg SPACE JOINT 1/8 IN. BAND BOARD OVER t PANEL FILLER 1. 2 in.x 10 in. Refer to nailing instructions band board 1I8 m.gap 7 Filler Board �-- Siding(4 ft.x 8 ft.) LP panel sidings are accepted by the State of California as category 8140-Exteriorwall siding and sheathing for Wildland Urban Interface Figure 6 (WUI)applications. For WUI compliance,install LP panel sidings in accordance with Louisiana-Pacific's printed installation instructions with the addition of fire retardant seal(UL Listed fire caulk,nominal � . 1/4"bead)in the vertical joint and nailing pattern of 3"OC perimeter �A444.�'6:Q6 Na D"C'aa1�.a4af t.'C-' 6;,14-1 Jl�� nim nailing/8' 1 OC field nailing: Look for the California State Fire Marshal Office label on our siding. The Louisiana-Pacific Corporation("LP")LP SmartSide Siding(the OR "Products")limited warranty(the"Warranty")applies only to Sip plate structures on which the Products have been applied,finished and Sill plate maintained in accordance with the published application,finishing Extend j and maintenance instructions in effect at the time of application. sidinelow ( The failure to follow such application,finishing or maintenance Sill late {{(}( Flashing instructions will void the Warranty as to the portion of the Products P lil 7 -77 7,. r h: x� n affected by the variance(the"Affected Products"). Min.1/8 in.or tri LP assumes no liability for any loss or damage sustained by the flashing between siding and Masonr Affected Products and is expressly released by the purchaser or owner h _ y F masonry. foundation " from any such loss or liability. Any modification of the Warranty's application,finishing or Figure iA Figure its maintenance requirements is void and unenforceable unless approved in writing prior to application by the Siding General Manager or his designee and a member of the LP Legal Department. For a copy of the warranty or for installation and technical support,visit the LP SmartSide product support Web site at: Interior Finish Siding www.lpsmartside.com Code Approved Breathable or for additional support call 800-450-6106. t Water-Resistive Barrier i 3/8 in gap WARRANTY REMEDIES ARE NOT AVAILABLE IF Sloped flashing with REQUIREMENTS ARE NOT FOLLOWED. ----" 4 in.vertical leg Trim Cal.Prop 65 Warning:Use of this product may result in h` Nail fin exposure to wood dust,known to the State of California Space window)door per (do not damage) to cause canter. manufacturer's instruction Figure 8 SMARTS 1 D E TRIM 6 SIDING BUILDING PRODUCTS 02014 Louisiana-Pacific Corporation.All rights reserved.LP,SmartSide,SilverTech and SmartFinish are registered trademarks of Louisiana-Pacific Corporation.Printed in U.S.A. NOTE:Louisiana-Padfic Corporation periodically updates and revises its product Information. To verify that this version Is current,call 800-450-6106. LPZ80512 1114 alternate inside corner details Gap 3/16 in. Gap 3/16 in:and seal and seal } ! t1 caulk y �i 111 f 4f figure.20A Figure 30B Figure 10 Vapor Retarder -` if required by code bio II Breathable water-resistant barrier yam, 6 In i a . . �- .� <�'�, �i%tom^ i./j•a't • y y .y i . 1 JN� YY Yl {/jam-�T,317 1 �Vf � •,-i. I :Z: VLv -` �, '. .'T :••��rj'Y it y I ii�.�:,' t��•�^.r � e.; t •rte 6 in mm=mum ' S'•r �. i.i 9�• f f r VV.' ground clearance paint figure 10C bottom course detail panel joint Figure 10E Figure 100