Loading...
HomeMy WebLinkAboutProduct Approval (3) J , Florida Building Code Online Page 1 of 2 BCIS Home ! Log In { User Registration ( Hot Topics I Submit Surcharge Stats&Facts ( Publications Contact Us ( BCIS Site Map ( Links , Search E Product Approval .USER:Public User D r �s-,-, • q 'Lu:tri�•�tr Product Aooroval Menu>Product or Aoolication Search>Aoolication List>Application Detail FL# FL10674-R13 Application Type Revision Code Version 2017 Application Status Approved Comments Archived u3 Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo,OH 43659 (740)404-7829 -greg.keeler@owenscorning.com Authorized Signature Greg Keeler greg.keeier@owenscorn i ng.torrr Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo,OH 43659 (419)376-8360 mel.sancrant@owenscornig.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer D Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert J.M. Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 05/16/2020 Validated By John W.Knezevich,PE 971 Validation Checklist-Hardcopy Received Certificate of Independence FL10674 R13 COI 2017 01 C01 Nieminen.odf Referenced Standard and Year(of Standard) Standard Year ASTM D316f 2016 ASTM D3462 2010 ASTM D7158 2011 Equivalence of Product Standards Certified By Sections from the Code https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5V%... 6/12/2019 Florida Building Code Online Page 2 of 2 Product Approval Method Method 1 Option D Date Submitted 10/10/2017 Date Vaiidated 10/11/2017 Date Pending FBC Approval 10/15/2017 Date Approved 12/12/2017 Surnmary of Products FL# Model,Number or Name Description 10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab,5-tab,laminated,starter and hip&ridge Shingles and Starters shingles Limits of Use Installation Instructions Approved for use in HVHZ:No FL10674 R13 II 2017 10 FINAL ER OC ASPHALT Approved for use outside HVHZ:Yes SHINGLES FL10674-R13.Ddf Impact Resistant:N/A Verified By: Robert J.M.Nieminen PE-59166 Design Pressure:N/A Created by Independent Third Party:Yes Other:Refer to ER,Section 5. Evaluation Reports FI-10674 R13 AE 2017 10 FINAL ER OC ASPHALT S! TM L_P F(:n574-R.13.n0f Created by Independent Third Party:Yes Back Yext Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Copyright 200772013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please click hem. Product Approval Accepts: iy -. EChiKF. -xt. Credo Card Safe https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5 V%... 6/12/2019 EXTERIOR RESEARCH&DESIGN,LLC. Certificate of Authorization#9503 a 1 353 CHRISTIAN STREET,UNIT#13 TRINITY!(ER® OXFORD,CT 06478 (203"}262-9245" EVALUATION REPORT Owens-Corning Evaluation"Report037940:02.12=R8 One Owens Corning Parkway FL10674-1113 Toledo,OH 43659 Date of Issuance:02/06/2012 (740)404-7829 revision S: 10/09/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6t' Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles WEkJN6: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1/R905.2.6.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced ^ua!ity Assurance documentation changes,c provisions-of the'Code that"relate to the product charge. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinitylERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinityl ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: 4►f- ltt�,r,�y Robert J.iVf.N(eminen P.E. The facsimile seal appearing was authorized by Robert Florida Registration No.59166,Florida DCA ANE1983 Nieminen,P.E.on 10/09/2017.This does not serve as an electronically signed document. CEf rrfFICAT10NnF-INDEPENDENCE. 1. Trinity lERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.docs not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. TRINITY ERD ROOFING SYSTEMS(VALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: .Asphalt Shingles Compliance Statement: Owens Corning Asphait Roof Shingles,as produced by Owens Corning,Piave demonstrated compliance with the following sections of the a Edition (2017) Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the ins"talla"tion Requirements and Limitations%Conditions of-Use set forth herein. 2. STANDARDS: Section Pro a Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1,11909.2.6.1 Wind Resistance ASTM D3161 2(116 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011 3. REFERENCES: Enty Examination Reference Date UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263- 04/18/2006 UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012 UC LLC ITST9628) fhysicats&Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02/13/2014 UL LLC(TST9628) Physical Properties Classification letter 10/02/2015 Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation Exp.05/16/2020 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic and Supreme®are fiberglass reinforced,3-tab asphalt roof shingles. 4.1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles. 4.1.3 Devonshire'are fiberglass reinforced,5-tab asphalt roof shingles. 4.1.4 Duration®, TruDefinition® Duration®, Duration® Premium Cool, TruDefinition® Duration® Designer Color Collection, TruDefinition®Oakridge, Oakridge® and WeatherGuard® HP are fiberglass reinforced, laminated asphalt roof shingles. 4,2_ Hip&Ridge Shingles. 4.2.1 Berkshire® Hip & Ridge Shingles, High Ridge, WeatherGuard® HP Hip & Ridge Shingles, ProEdge Hip & Ridge Shingles and DuraRidgell Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. 4.3 Afcessory Sta aer'Strips: 4.3.1 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity.]ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this t:valbation Report,or previous versions thereof,is/was used fur pe,Emitting or design guidance illness retained Specifically fur that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design,U.C. Evaluation Report 037940.02.12-R8 Certificate of Authorization 89503 67H EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1113 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 2 of 8 TRINITY ERD 5.4 Wind Classification: 5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 ancl-8906.2.6.1 to ASTM(131.61,Class f and/or ASTM 07158,Efass H,indicating the shingles are acceptable for use in all wind zones up to Vasa = 150 mph (Vult = 194 mph). Refer to Section 6 for installation requirements to meet this wine}rating. 5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up to Vasd=150 mph(Vult=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C, as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 611320-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 611320-3,per FBC 1507.2.3,1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: ➢ Berkshire shingles require minimum five(5)nails per shingle. ➢ WeatherGuarde HP shingles require minimum six(6)nails per shingle. ='Devonshire TM-shirigles-require-minimum-six-(6)naifs-per-shingle. Q -Starter.Strip Shingle.and_Starter Strip.-Plus_require minimum-ive(5)_ iails.per.strip.. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be..in..accordance--with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required-. See-figures belowfor details.. 6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus: Felt underlayment Deck Felt Deck Self-adheredunderlayment ii,4_ WeatherLockp• Self adhered underlaymem WeatherLocka I- undedayment L. - _ Drip edge Drip; r y Drip edge Drip--• t edge Naos located Nails located z-3-trom gave Z"-r from eave Installfust. Self-sealing adhesive Self-sealing adhesive Instal first Starter Strip Plus positioned along eave Starter Strrp positioned along eave w th E removed shingle with 6"removed \ r a Starter Strip us Ploverhan s eaves and rakes 1/4-3/4' Starter Strip shingle overhangs eaves and rakes;�_/i' g. Exterior Research and Design,U.C. Evaluation Report 037940.02.12-R8 Certi/lcateojAuthorization#9503 6T"EDITION.(2017)FBC NON-HVHZEVALUATION, FL10674-1113 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 3 of 8 ®TRINITY ERD 6.2.6 Minimum Nailing—Classic®&Supreme: Normal Mansard or Area para Normal Mansard or Area para Wind Areas High Wind desvanes y Wind Areas High Wind desvenes y Area pare vientos normales Areas vientos fuertes Area para vientos normales Areas vientos fuertes r2' '' '� 1AL 1. -1- 2- iBi t2' 1' 11' 71' 121 '+ —121 ) 5"Exposure 5 5!8"'Exposure ExposiciBn Exposicidn 6.2.7 Minimum Nailing—Berkshire®: Sealatn strip Sealant strip La lira de sellada La tira de sellador qt' 9 Vt 8 Ili" Vz" 8 lie W., } r Standard Fastening Pattern 6-Nail Fastening Pattern Sealanfstrip La lira do sellador 1 1.. t 2" Asphalt roofitigsemenl cemento de techo de astafto Mansard or Steep-Slope Tastening-Pattern Exterior Research and Design,U.C. Evaluation Report 037940.02.12-R8 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 4 of 8. TIN ITY{ER 6.2.8 Minimum Nailing—Devonshire TM: 7t^ i?n i $u I 8n I 8n I 7" Naas -- - `• craves _ Nails 5.5/8"exposure } Sealant location Exposici6n.do 5.5/8 puig. ' Uhicaci6n del sellador �.t• Ten 1"Spots of Asphalt Roof Cement Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern 6.2.9 Minimum Nailing — Duration®, TruDefinition® Duration, Durations Premium Cool & TruDefinition is Duration Designer Color Collection: 4-Nail Fastening Pattern 6-Nag Fastening Pattern SureN3*91aStening area width SmeNaiM fastening yea wielh Nall,lypidal Nan Typical 1" 12 12 1" Ti 1Y" 12" 1 —r bila"6318" 6115"6318" J _ Standard Fastening Pattern 6-Nail Fastening Pattern Fastening for Slopes Greater Than 2112 sur.uoiN!Teitoningareawidth Na14 Typical t 12 E,r 61/6"6•SR^ 0 Four 1–Spots of Asphatl Rwfing cement Mansard or Steep Slope Fastening Pattern Exterior Research and Design,-U.C. Evaluation Report 037940.02.12-RS Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1113 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 5 of 8 `��I TRINITY`ER® 6.2.1 Minimum Nailing-TruDefinition®Oakridge®,Oakridge®: 4 Nail Pattern 6 Nail Pattern hquema con4 clavos Esquema con 6 clavos 12- 5 516"-ExposureMalls5 5/8"Exposure Nails Fxposicioade66/Sp+d9• Clavas Exposidtinde55/8pulg. 55/8"Exposure Claws 6W"Exposwe Fxposid6n de 66/8 pu4 Exposieiorr de 56/8 pulg. Standard Fastening Pattern 6-Nail Fastening Pattern Fastening for Stopes Greater Than 21:12 Sm 140)fastening ere-M-th Nall 7gPloal -I--- —I 1. nrll8'5.51r. _ Faun 1'Spore olAsphaR Ro-flog Cement Mansard or Steep Slope Fastening Pattern 6.2.1 Minimum Nailing—WeatherGuard®HP: 1■ '� t QI *SiVANIft de View Imo— 2' 7 =>I :i�:• Fmht�71�w1 Mdl Lie. CJwI��o J'alifr�Apdfl� Exterior Research and Design,-LLC. Evaluation Report 037940.02.12-R8 Certifcate of Authorization#9503 61H EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-1113 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 6 of 8 TRINITY!ER® 6.3 Hip&Ridge Shingles: 6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, WeatherGuard• HP Hip and Ridge Shingles tinct t'roEdge#till & Ridge Shingles shall comply with the Owens Corning current published instructions, using four (4) nails per shingle. Installation of DuraRidge` Hip & Ridge Shingles shall comply with the Owens Corning current published-instructions, using two (:21 nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand-sealing for wind warranties. 6.3:2 Fasteners shall be in accordance with the manufacturer's published-requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge: Fig.1 Fig.2 E. Preualim1VUntl \ Oireabrr � A � iapVlew SIUCVf6v \ Nall--------�, -Nall Nails 4 Z Topa.mina,etl r ,. a' Piece Wit_-y cJl 6.3.4 Minimum Nailing—WeatherGuard®HP Hip and Ridge: F.i Fig.C Hip&Ridge Shingle Fastening. 9'A 4 4 ng Top Vlew. f--Direclb Dovan Wind Nails �\ A ?. 2" ,1.. N, A ,; i i • I I + r Expown: B, .Exposure �\ \ Exterior Research and Design,LLC. Evaluation Report 037940.02.12-Rg Certificate ofAutharization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1113 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 7 of 8 TRINITY:ERD 6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles: Prevailing Standard Wind Direction Fastening Sealant Strip Pattern G"Exposure !' �-1 14- ~I.1 I� 12' I Sealant Fasten 711: 7 II zu 6"Exposure Cover Exposed Fasteners with ` Roof Cement 6.3.6 Minimum Nailing.—DuraRidgelm Hip.&Ridge Shingles:. Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. Prevailing wind Diroc6an We en plan Direction dornimncodivont II- We en plan I'Iy Dirocatmdel"viento prodorninuue s cies 21r � Ol_Cl15 Cormn�,Sup ila Clos tCClait . .�.'z ai -i---�--I.. �I ' I rrE�paew V.�2 7: WELWG: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 150-7.2.7.1 f R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements.: 10. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625;(631)546-2458;Kanchi.Agrawala-Dokania@ul.com - END OF EVALUATION REPORT- Exterior Research and Design,U.C. Evaluation Report 037940.02.12-118 Certificate of Authorization 119503 6M EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 8 of 8